Test Conducted: As Per the Request Of The Applicant. For Further Details Please Refer to Enclosed Page(S)
Authorized By
For Its Labtest Bangladesh Ltd. [Testing
Footwear]
Mominul Islam
Head Of Analytical Laboratory, Softlines
Rating
SL NO Test Name
Part-1
1 Total Heavy Metals Content P
2 Heavy Metals Migration P
3 Formamide Content F
4 Acetophenone Azine Content P
5 Phthalates Content P
*Chromium (Cr) = launch migration of total Cr & CrVI content Tests if Cr > 100 ppm
*Nickel (Ni) = Additional test + USA Warning, please refer to "Materials" sheet (HM migration if Ni>45ppm, Ni release if Ni>50ppm
(metal only)
*Tin (Sn) = Additional test, please refer to "Materials" sheet (Organotins if Sn>0,1ppm or 10ppm Tin migration if Organotin FAIL
for other material)
*Arsenic (As) = USA Warning, please refer to "Materials" sheet (HM migration if As>10ppm)
*Lead (Pb) = USA Warning, please refer to "Materials" sheet (HM migration if Pb>60ppm)
*Cobalt (Co) = Additional test, please refer to "Materials" sheet (Co release if Co>50ppm, Metal only)
Result(mg/kg) Requirement
Elements
Part-(1) Other Baby
Arsenic (As) ˂0.1 1.0 ppm 0.2 ppm
Cadmium (Cd) ˂0.05 0.1 ppm 0.1 ppm
Cobalt (Co) ˂0.5 4.0 ppm 1.0 ppm
Barium (Ba) ˂100.0 1000 ppm 1000 ppm
Copper (Cu) ˂5.0 50.0 ppm 25.0 ppm
Chromium (Cr) ˂0.5 2.0 ppm 1.0 ppm
Chromium VI (Cr- VI) ˂0.2 0.2 ppm* 0.2 ppm*
Mercury (Hg) ˂0.02 0.02 ppm 0.02 ppm
Nickel (Ni) ˂0.1 1.0 ppm 1.0 ppm
Lead (Pb) ˂0.1 1.0 ppm 0.2 ppm
Antimony (Sb) ˂3.0 30.0 ppm 30.0 ppm
Tin (Sn)* * ˂0.1 No requirement** No requirement**
Result (mg/kg)
Substance CAS Part-(1) Requirements
By solvent extraction and followed by Gas Chromatography - Mass Spectrometric (GC-MS) analysis
Requirements
Result (mg/kg))
Substance CAS
Part (1)
* Di(2-Ethylhexyl) Phthalate (DEHP) = USA Warning, please refer to "Materials" sheet (>500 ppm)
* Dibutyl Phthalate (DBP) = USA Warning, please refer to "Materials" sheet (>500 ppm)
* Di-Iso-Nonylphthalate (DINP) = USA Warning, please refer to "Materials" sheet (>500 ppm)
Sample Picture
This Report Is Made Solely On The Basis Of Your Instructions And/Or Information And Materials Supplied By You. It Is Not Intended To Be A Recommendation For
Any Particular Course Of Action. Intertek Does Not Accept A Duty Of Care Or Any Other Responsibility To Any Person Other Than The Client In Respect Of This
Report And Only Accepts Liability To The Client Insofar As Is Expressly Contained In The Terms And Conditions Governing Intertek's Provision Of Services To You.
Intertek Makes No Warranties Or Representations Either Express Or Implied With Respect To This Report Save As Provided For In Those Terms And Conditions. We
Have Aimed To Conduct The Review On A Diligent And Careful Basis And We Do Not Accept Any Liability To You For Any Loss Arising Out Of Or In Connection With
This Report, In Contract, Tort, By Statute Or Otherwise, Except In The Event Of Our Gross Negligence Or Wilful Misconduct.