Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Ref.

To: Tech Offer Technical Office


Date: 8/26/2019,7:11 PM EL SEWEDY CABLES

Technical Offer For Cables Generally to IEC 60227


General Information:
‐Short Description: CU/PVC/PVC
‐Voltage: 300/500 V
‐Conductor: Flexible Plain Copper Conductor according to IEC 60228 Class 5
‐Insulation / Tempreature: PVC Insulation / 70°C
‐Sheathing Material / Temp. / Color: PVC Sheathing Flame Retardant IEC 60332‐1 / 70°C / Gray

Cable Marking: = EL SEWEDY CABLES = No. of cores x size mm2 CU/PVC/PVC 300/500 V Manufacturing Year Meter Marking
Printing Type: Ink Jet (Printing)

Core Identification:
‐2 Cores: Red, Black
‐3 Cores: Red, Yellow, Blue
‐4 Cores: Red, Yellow, Blue, Black
‐5 Cores: Red, Yellow, Blue, Black, G/Y
‐> 5 Cores: Black Coloured Cores With White Numbers
‐Polypropylene binder tape(s) and/or fillers may be used when necessary according to manufacturing process

Packing:
‐Cable shall be supplied in lengths as indicated in technical schedule on non returnable wooden reels up to the manufacturer.
‐Both ends of the cable shall be sealed to prevent the ingress of moisture during transportation and storage.
‐Each reel shall be marked with type, size and length of Cable, and weight.
‐This information shall be written on metallic tag nailed properly to the flange.
‐Cutting lengths is 500 m ± 5% on each reel for 19 cores cables and above, and 1000 m ± 5% for other cables.
‐Metering on cable outer sheath will be started from "X" to "X+999" m for 1000m cutting lengths and to "X+499" m for 500m cutting lengths

Cable Properties:
‐Outer sheath will be flame retardant according IEC 60332 Part 1

Tests:
‐Routine tests generally to IEC 60227 are performed on the cables and test certificate will be supplied on request.
‐Electrical Resistance of the conductors shall be tested on IEC 60228.
‐Voltage Test: No breakdown of The insulation shall be occured, The applied Voltage and duration will be according to IEC 60227

Specifications:
Approx. Outer Approx. Cable Min. Bending Max. Conductor Conductor AC
No. of Size
Diam. Weight Raduis DC Resistance Resistance at Max.
Cores (mm2) (mm) (Kg/Km) (mm) at 20 °C (Ω/Km) Operating Temp.
and 50Hz (Ω/Km)
2 1 6.5 61 52 19.5 23.33
2 1.5 7.5 83 60 13.3 15.91
2 2 8.5 109 68 9.89 11.83
2 3 9.6 143 77 6.61 7.91
2 4 10.6 181 85 4.95 5.92
2 10 14.2 356 114 1.91 2.29
2 16 16.3 498 130 1.21 1.45
3 2 9.3 139 74 9.89 11.83
3 3 10.2 179 82 6.61 7.91
3 4 11.3 226 90 4.95 5.92
3 10 15.6 471 125 1.91 2.29
4 2 10.2 169 82 9.89 11.83
4 4 12.8 292 102 4.95 5.92
4 6 14.1 387 113 3.3 3.95
4 10 17.1 591 137 1.91 2.29
4 16 19.4 828 155 1.21 1.45

‐The above data is approximate and subjected to manufacturing tolerance.

Prepared By:
Ahmed Mohamed Abd El Gaber SC‐TC‐FR‐03
Design Section Head Page 1 of 1