SITUATION: Isolated cases have shown that the top o-ring does not have
enough pre-load. In such cases the PVG 32 pressure adjusting
valve can experience change of pressure setting.
Note; No case of leaking has yet surfaced.
SOLUTION: Recommendation from the manufacturer is to replace the o-rings in all new
Danfoss PVG32 Relief Valves on the valve bank when servicing a failure.
Existing o-ring, NBR 70º shore 1.5 mm thickness x 7.5 mm inside diameter, is
to be replaced with o-ring WA107905, NBR 90º shore 1.5 mm thickness x 7.5
mm inside diameter.
To change o-ring, take out retaining circlip (size 11mm for bores). Wind out
the hexagon socket pressure set screw with an Allen key and replace the
o-ring.
CAMPAIGN: (PIP) Details PC0403
O-rings to be changed as they fail.
Allowable labour is 3 hours maximum and claims are to be submitted within 30 days of the
completion of the repair. This claim is to be accompanied by a campaign registration form,
(attached).
Campaign/PIP # PC 0403
Carrier Hours:
Repair Date:
Claim #
Dealer #
Dealer Name:
Completed By:
Comments