02. PID - Main & Reheat Steam 1-3
02. PID - Main & Reheat Steam 1-3
REFERENCE DRAWINGS
DRAWING NUMBER DRAWING TITLE
NOTES :
1. THIS P&I DIAGRAM IS FOR UNIT 1
THE P&I DIAGRAM FOR UNIT 2 IS BASICALLY THE SAME AS THAT FOR UNIT 1
WITH PLANT CODE KEY =2.
≥ 60°
PIC TI PI TICA++/+/-/-- TP
- - - - 12LBA10CT401
AA301 AA302
AA303 AA304
AA305 AA306
AA307 AA308
AA309 AA310
3 3
S C C S
FROM SUPERHEATER OUTLET 12LBA10 WITHIN 3M TO TBN MAIN STOP VALVE
BR001 BA1
IKCP0-HA-BLRM-21-511 (N-3) IKCP0-YYG-STGP-21-001 (A-1)
DN 350 350 x 300 REFERENCE DRAWINGS
≥ 10M 1. P&I DIAGRAMS
AA601
- SYMBOL & LEGEND (1/3) : IKCPL-YYG-M-21-001
- SYMBOL & LEGEND (2/3) : IKCPL-YYG-M-21-002
I STCS
- SYMBOL & LEGEND (3/3) : IKCPL-YYG-M-21-003
DN 65
12LBA10
BR411 BA1
AA602
TO SAMPLING AND ANALYSIS TA+/- MOV
4 12QUB20 - 4
SYSTEM (2/2) 12LBA10AA211
BR601 BA1 IN TO START-UP FLASH TANK
IKCP0-QUL-I-21-001 (H-3)
DN 25 M SILENCER
LO 3 REFERENCE DOCUMENTS
IKCPL-LCM-M-21-001 (A-2) 1. PIPING MATERIAL CLASSIFICATION : IKCPL-YYG-P-02-001
12LBA11
BR001 BA1
DN 300
AA411 WARMING LINE
2. TECHNICAL SPECIFICATION FOR INSULATION : IKCPL-YYG-P-02-002
3. INSTRUMENT SET POINT & ALARM LIST : IKCP1-CKN-I-08-002
4. SYSTEM DESCRIPTION
TI
- I - MAIN AND REHEAT STEAM SYSTEM : IKCPL-LBA-M-03-001
5 5
MOV
TIT 12LBA10AA201
12LBA10CT106
IN
M 12LBA10 TO START-UP FLASH TANK
LO BR401 BA1
IKCPL-LCM-M-21-001 (A-4)
TIT AA403 DN 50
12LBA11CT101
DN200
6 TIA- 6
AA401
-
BA1 HB4
12QJB31 FROM N2 FILLING CONNECTION
BR001 HB4
DN25
IKCPL-QJB-M-21-001 (N-9)
AA012 AA011 DN 25 R CIVIL
CONTRACTOR DOCUMENT REVIEW
AA402
FI E
- I V
MECH
LOG DATE : I ELECT
E
IN COMM NO. : W I&C
PDIA + FIT PIA- - TI A APPROVED SUPPORT
- 12LAE20CF102 - -
7 B APPROVED AS NOTE D CONTRACTOR 7
C I
NOT APPROVED RECORD
PDIT FIT PIT PI TIT S
12LAE20CP151 12LAE20CF101 12LAE20CP101 12LAE20CP501 12LAE20CT101 * PCV
I INFORMATION T
R
WORKING DOCUMENT
12LBA11AA101
TURBINE TRIP
APPROVAL DOES NOT RELIEVE
AA301 AA311
AA302 AA312
AA305 AA315
AA306 AA316
AA307 AA317
AA308 AA318
AA303 AA313
AA304 AA314
APPROVED BY I
CONTRACTOR FROM RESPONSIBILITY
* TCV
I I
FOR ERROR OR DEVIATIONS FROM
CONTRACT REQUIREMENTS
( ) B
U
12LAE20AA101 T
BY: DATE :
FROM BFP INTERSTAGE 12LAE20 12MAN21
I
AT001 LOG DATE : O
BR001 DB2 FC LO BR001 BA1
IKCPL-LAB-M-21-001 (N-8) N
LO DN 100 FC DN 50
OUT COMM NO. :
8
STRAIGHT MIN. 18D STRAIGHT MIN. 3.5D FC AA001 8
AA401 AA402
AA001 3
FE XV
12LAE20CF001 12LAE20AA251
3 23.AUG.'19 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'18) S.W.YOON S.W.YOON J.W.SON
3 2 19.JUL.'18 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON JAN.03.'18) S.W.YOON S.W.YOON J.W.SON
12MAN20
BR001 DA2
DN 500
1 03.NOV.'17 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'17) S.W.YOON S.W.YOON J.W.SON
STRAIGHT MIN. 5M
TIA++/--
- REV. DATE DESCRIPTION DRWN CHKD APPD
9 9
OWNER:
PT PLN (PERSERO)
Jl. Trunojoyo Blok M I/135, Kebayoran Baru Jakarta 12610
Phone: +62-21-7261875, 7261122, 7262234, Fax : +62-21-7221330
PIA+ TIC e-mail: webmaster@pln.co.id
- - Contract Agreement No. : 1594.PJ/DAN.02.01/DIR/2016
DA2
AA301 AA311
AA302 AA312
PROJECT:
KALSELTENG 2 CFSPP(2x100MW)
12MAN20 TO COLD REHEAT STEAM LINE
BR002 EB1
IKCPL-LBA-M-21-002 (N-3) CONTRACTOR:
DN 500 CONSORTIUM OF
PT TRUBA JAYA ENGINEERING - HYUNDAI ENGINEERING CO., LTD. - ITOCHU CORPORATION
11 11
HP BYPASS SYSTEM
CHECKED BY
23.AUG.'19
DATE
P&I DIAGRAM
S.W.YOON 23.AUG.'19 MAIN AND REHEAT STEAM SYSTEM
APPROVED BY DATE (1/3)
12 J.W.SON 23.AUG.'19 12
CLASSIFICATION NO. SCALE JOB NO. DRAWING NUMBER REV.
- - IKCPL-LBA-M-21-001 3
A B C D E F G H I J K L M N O P Q A2 (420X594mm)
A B C D E F G H I J K L M N O P Q
REFERENCE DRAWINGS
DRAWING NUMBER DRAWING TITLE
1 1
NOTES :
1. THIS P&I DIAGRAM IS FOR UNIT 1
THE P&I DIAGRAM FOR UNIT 2 IS BASICALLY THE SAME AS THAT FOR UNIT 1
WITH PLANT CODE KEY =2.
AA307 AA308
AA305 AA306
AA303 AA304
AA301 AA302
FOR DRY
12LBC10AA251
** AIR INLET
S C DN25 C S
TO REHEATER INLET 12LBC10 12LBC10 FROM HP TURBINE EXHUST
BR002 EB1
3 BR001 EA2
IKCP0-HA-BLRM-21-511 (N-9) IKCP0-YYG-STGP-21-001 (E-1)
600 x 450 DN 600 DN 600 600 x 450
5 FC 5
C
EB1 EA2
TA+/-
I
S
-
TI
-
TI TA+/- FROM MCV, OLV SPINDLE
DN300
- - LEAKAGE LINE
MOV DN25
TIT
IN
12LBC10AA221
12LBC10CT105
IKCP0-YYG-STGP-21-001 (C-8)
M I
TO CONDENSER FLASH TANK 12LBC10
TIT
DN300
LOBR421 EB1 MOV
6 IKCPL-LCA-M-21-001 (J-8) 12LBC10CT106 6
DN300
DN 50 12LBC10AA211
BS AA423 IN
M
12LBC10 TO CONDENSER FLASH TANK
BR411 EB1 LO
IKCPL-LCA-M-21-001 (J-8)
DN 50 AA413 BS R CIVIL
AA421
W
AA412
A APPROVED SUPPORT
7 B APPROVED AS NOTE 7
DN25
D CONTRACTOR
I
TO HP FWH NO.6 12LBQ20 AA311 AA312
C NOT APPROVED RECORD
AA411
S
BR001 EB1 I INFORMATION T WORKING DOCUMENT
IKCPL-LBQ-M-21-001 (H-3)
DN 150 AA314 AA313 APPROVAL DOES NOT RELIEVE APPROVED BY
R
LSHH LA ++ I
12LBC10CL201 - I CONTRACTOR FROM RESPONSIBILITY
FOR ERROR OR DEVIATIONS FROM ( ) B
CONTRACT REQUIREMENTS U
LA + LSH T
BY: DATE :
- 12LBC10CL202 I
AA315 AA316 O
LOG DATE :
N
OUT COMM NO. :
8 AA318 AA317 XV 8
12LBC10AA252
12LBC10 TO CONDENSER FLASH TANK
LO
BR401 EA2
IKCPL-LCA-M-21-001 (J-9) 3 23.AUG.'19 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'18) S.W.YOON S.W.YOON J.W.SON
AA403 BS DN 50
FO 2 19.JUL.'18 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON JAN.03.'18) S.W.YOON S.W.YOON J.W.SON
1 03.NOV.'17 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'17) S.W.YOON S.W.YOON J.W.SON
KALSELTENG 2 CFSPP(2x100MW)
CONTRACTOR:
CONSORTIUM OF
PT TRUBA JAYA ENGINEERING - HYUNDAI ENGINEERING CO., LTD. - ITOCHU CORPORATION
11 11
CHECKED BY
23.AUG.'19
DATE
P&I DIAGRAM
S.W.YOON 23.AUG.'19 MAIN AND REHEAT STEAM SYSTEM
APPROVED BY DATE (2/3)
12 J.W.SON 23.AUG.'19 12
CLASSIFICATION NO. SCALE JOB NO. DRAWING NUMBER REV.
- - IKCPL-LBA-M-21-002 3
A B C D E F G H I J K L M N O P Q A2 (420X594mm)
A B C D E F G H I J K L M N O P Q
REFERENCE DRAWINGS
DRAWING NUMBER DRAWING TITLE
NOTES :
1. THIS P&I DIAGRAM IS FOR UNIT 1
THE P&I DIAGRAM FOR UNIT 2 IS BASICALLY THE SAME AS THAT FOR UNIT 1
WITH PLANT CODE KEY =2.
≥ 60°
PP PIT PIT TP TIT TIT PIT PP TIT TIT TP TP 3. IT IS RECOMMANDED TO CLOSE TO CONDENSER INLET.
12LBB10CP401 12LBB10CP101 12LBB10CP102 12LBB10CT401 12LBB10CT101 12LBB10CT102 12LBB10CP103 12LBB10CP402 12LBB10CT103 12LBB10CT104 12LBB10CT402 12LBB10CT403
AA301 AA302
AA303 AA304
AA305 AA306
AA307 AA308
AA309 AA310
3 3
S C
FROM REHEATER OUTLET 12LBB10 TO REHEAT STOP VALVE
BR001 DA1
IKCP0-HA-BLRM-21-511 (N-6) IKCP0-YYG-STGP-21-001 (A-1)
DN 500
500 x 450 WITHIN 3M
REFERENCE DRAWINGS
C S
AA601
1. P&I DIAGRAMS
TIC TA+/- - SYMBOL & LEGEND (1/3) : IKCPL-YYG-M-21-001
DN300
- -
- SYMBOL & LEGEND (2/3) : IKCPL-YYG-M-21-002
AA602
- SYMBOL & LEGEND (3/3) : IKCPL-YYG-M-21-003
4 I 4
TIT MOV
12LBB10CT106 12LBB10AA201
TO SAMPLING AND ANALYSIS IN
12QUB21 M 12LBB10
BR001 DA1
12LBB11
DN 500
SYSTEM (2/2) TO START-UP FLASH TANK
BR601 DA1 LO BR401 DA1
IKCP0-QUL-I-21-001 (K-6)
DN 25 DN 50
IKCPL-LCM-M-21-001 (A-4) REFERENCE DOCUMENTS
AA403
1. PIPING MATERIAL CLASSIFICATION : IKCPL-YYG-P-02-001
2. TECHNICAL SPECIFICATION FOR INSULATION : IKCPL-YYG-P-02-002
3. INSTRUMENT SET POINT & ALARM LIST : IKCP1-CKN-I-08-002
AA401
DA1 HB4 12QJB33 4. SYSTEM DESCRIPTION
FROM N2 FILLING CONNECTION
5 BR001 HB4 - MAIN AND REHEAT STEAM SYSTEM : IKCPL-LBA-M-03-001 5
DN25
IKCPL-QJB-M-21-001 (N-3)
AA012 AA011 DN 25
AA402
TIT TIA-
12LBB11CT101 -
FROM CONDENSER
6 TEMPERATURE 6
I IKCPL-LCA-M-21-001 (G-2)
R CIVIL
CONTRACTOR DOCUMENT REVIEW
FIC E MECH
- * XV LOG DATE :
V
I ELECT
12LBB11AA251
PIC IN COMM NO. :
E
I&C
W
PDIA + FIT PICA- - TIC -
A APPROVED SUPPORT
- 12LCE50CF102 - -
7 * PCV B APPROVED AS NOTE D CONTRACTOR 7
12LBB11AA101 I
FC
TURBINE TRIP
C NOT APPROVED RECORD
PDIT FIT PIT PI TIT PIT I INFORMATION
S
WORKING DOCUMENT
T
12LCE50CP151 12LCE50CF101 12LCE50CP101 12LCE50CP501 12LCE50CT101 12LCE50CP102
I
AA303
R
AA304
AA305
AA306
AA302
AA307
AA308
AA309
AA001 N
FE * TCV OUT COMM NO. :
8 12LCE50AA101 8
12LCE50CF001
ENTHALPY CONTROL
3 3 23.AUG.'19 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'18) S.W.YOON S.W.YOON J.W.SON
BR001 GA1
12MAP20
DN 800
2 19.JUL.'18 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON JAN.03.'18) S.W.YOON S.W.YOON J.W.SON
MIN. 3.1M TO CONDENSER INLET
1 03.NOV.'17 ISSUED FOR CONSTRUCTION (APPROVED BY OWNER ON SEP.12.'17) S.W.YOON S.W.YOON J.W.SON
PT PLN (PERSERO)
PIC TIA++ Jl. Trunojoyo Blok M I/135, Kebayoran Baru Jakarta 12610
- - Phone: +62-21-7261875, 7261122, 7262234, Fax : +62-21-7221330
e-mail: webmaster@pln.co.id
Contract Agreement No. : 1594.PJ/DAN.02.01/DIR/2016
PIT PIT TIT TIT
12MAP20CP101 12MAP20CP102 12MAP20CT101 12MAP20CT102 PT. PLN (PERSERO) PUSAT ENJINIRING KETENAGALISTRIKAN
NOTE 3
AA301
AA302
10 10
TO CONDENSER
PLN DWG NO.
1 0 1 1 8 B - 0 0 - M - 5 2 - L BA - 0 0 3 - 0 1 - 3
IKCPL-LCA-M-21-001 (J-3) PROJECT:
KALSELTENG 2 CFSPP(2x100MW)
CONTRACTOR:
CONSORTIUM OF
PT TRUBA JAYA ENGINEERING - HYUNDAI ENGINEERING CO., LTD. - ITOCHU CORPORATION
11 LP BYPASS SYSTEM 11
CHECKED BY
23.AUG.'19
DATE
P&I DIAGRAM
S.W.YOON 23.AUG.'19 MAIN AND REHEAT STEAM SYSTEM
APPROVED BY DATE (3/3)
12 J.W.SON 23.AUG.'19 12
CLASSIFICATION NO. SCALE JOB NO. DRAWING NUMBER REV.
- - IKCPL-LBA-M-21-003 3
A B C D E F G H I J K L M N O P Q A2 (420X594mm)