tr E384 -22

TABLE X3.2 Precision statistics for an lnterlaboratory Study of the Vickers Microi ndentation Hardness Test for Ferrous Specimens in
Diagonal Units (µm)
Specimen Test Force Average Standard Repeatability Reproducibility Repeatability Reproducibility
(gf) Diagonal Deviation Standard Standard Limit (µm) Limit (µm)
(µm) ( µ m) Deviation Deviation
( µ m) ( µ m)
d sx s, SR R
A 25 1 3.89 0.75 0.30 0.80 0.85 2.24
50 1 9.81 0.61 0.34 0.68 0.95 1 .91
1 00 28. 1 0 0.57 0.45 0.70 1 .26 1 .96
300 49. 1 9 0.75 0.72 0.99 2.02 2.77
500 63.65 0.81 0.88 3. 1 6 2.47 1 .1 3
1 000 90.48 0.98 1 .31 1 .53 3.66 4.28
B 25 9.35 0.40 0.25 0.46 0.69 1 .28
50 1 3.06 0.37 0.23 0.42 0.63 1 .1 8
1 00 1 8.51 0.39 0.39 0.52 1 .09 1 .47
300 32. 1 1 0.43 0.30 0.50 0.84 1 .41
500 41 .68 0.51 0.36 0.60 1 .00 1 .69
1 000 59.21 0.55 0.52 0.72 1 .46 2.03
c 25 1 0.81 0.53 0.19 0.56 0.54 1 .56
50 1 5. 1 3 0.42 0.20 0.46 0.57 1 .29
1 00 21 .34 0.40 0.22 0.45 0.62 1 .25
300 36.85 0.38 0.21 0.43 0.59 1 .20
500 47.68 0.55 0.24 0.59 0.67 1 .64
1 000 67.60 0.58 0.33 0.65 0.93 1 .83
D 1 00 24.50 0.43 0.29 0.50 0.82 1 .40
300 42.52 0.41 0.28 0.48 0.80 1 .35
500 55.02 0.50 0.25 0.55 0.70 1 .54
1 000 78. 1 4 0.70 0.34 0.77 0.97 2.15
E 1 00 1 5.61 0.40 0.18 0.43 0.52 1 .20
300 27.25 0.41 0.25 0.46 0.70 1 .30
500 35.26 0.43 0.20 0.46 0.55 1 .30
1 000 50.06 0.41 0.24 0.46 0.67 1 .29
T 300 23.94 0.47 0.17 0.49 0.49 1 .38
500 31 .00 0.51 0.21 0.55 0.59 1 .53
1 000 44. 1 2 0.50 0.25 0.55 0.69 1 .53

22
Copyright by ASTM lnt'I (all rights reserved); Wed Nov 09 07:44:14 GMT 2022
Downloaded/printed by
Shanghai Jiaotong University (Shanghai Jiaotong University) pursuant to License Agreement. No further reproductions authorized.