Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1 2 3 4 5 6

REVISIONS ULTIMATE BASE REACTIONS PILE


REV. DESCRIPTION DATE APPROVED
Part No. Pole Type Axial - P Shear - V Torque - T Moment - M Depth
A Drawing created 12.01.21 AS (kN) (kN) (kNm) (kNm) (m)
B Update drawing 10.02.21 AS
MFP-049 M2B - 7.2m 3 7 3 34 2.5
C Update drawing 26.03.21 AS
A A
WIND SPEED DATA NOTE:
Banners to be removed prior
900.0 Wind Region C
to Cyclonic Conditions.
Terrain Category TC3

VL - LUMINAIRE
We-ef RFL530
(By others)

OPTIONAL
Fabric Banner Kit
B (0.9 x 2.0m) B
Mast
MAST - Ø215
Material: Extruded Aluminium 130.0
Finish: Anodised Clear

3408.0
7200.0 - Overall Height

ELECTRICAL
6000.0 - VL Height

710.0
B B EQUIPMENT HATCH

170.0
SECTION B-B
SCALE 1 : 5

C SPLIT CLADDING ELECTRICAL C


CLADDING - Ø250
Equipment Hatches EQUIPMENT HATCH

600.0
Material: Extruded Aluminium 380.0 - PCD
Finish: Anodised Clear A A
Low Level
GPO Box Low Level
2258.0

GPO

493.0
1000.0

STEEL CORE
Material: Mild Steel 350 FGL
Finish: HD Galvanised Equipment
FGL
Plate

Slots suit to STEEL CORE


FRONT VIEW SIDE VIEW
M24 HD Bolts SCALE 1 : 20
SECTION A-A
D SCALE 1 : 10 D

PROJECT DATE SHEET MATERIAL


573 - Tondoon Botanical Gardens 12.01.21 A3 N/A
DWG TITLE DRAWN CHECKED FINISH

TOLERANCE
MFP sys t ems 7.2m Pole GA
DWG No. PART No.
A.SMITH J.McLEOD
REVISION SCALE
N/A
WEIGHT
x.x ± 1.0 multi function pole 7.2m Pole MFP-049 C 1:40 280.8 kg
x.xx ± 0.5
www.mfpsystems.com.au Ph: +61 2 8593 6092 C Copyright 2012
1 2 3 4 5 6

You might also like