06-28e_Sigma Control Firmware update

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

QEM-Sect.

: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 1 of 8

Category : Functional description Assembly instruction


Part modification/exchange Assembly notes
Trouble shooting

Main group Sub-Group


: Rotary Screw General Refrigeration dryers
Reciprocating Components Desiccant dryers
Mobilair : Electrics Breathing air
Omega Maintenance Plate-type heat exchangers
Air Treatment Competitors Fail-safe heat exchangers
Heat recovery : Controllers Straight-pipe heat exchangers
Air tools Filters
Accessories

Search terms: Technical Information, Software, Controllers

Sigma Control Firmware Update

Only the firmware for Sigma Control is updated with this software. The new version includes further
developments and fault analysis optimisation.

The menu structure and all software functions specific to the compressor remain unaffected. All
settings and operating parameters are taken over.

The update automatically detects the firmware installed on the controller and selects the new version
appropriately. If a software version is installed for which no update is intended, this is also detected and
the update is aborted.

• The KAESER update program can update 7.7000.0 und 7.7001.0 Sigma Control
controllers.

• Do NOT use this software for the new hardware versions [7.7000.1 und 7.7001.1].

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 2 of 8

Attention: This program is protected by the German Copyright Act and international contract
regulations. Unauthorised duplication or unauthorised sale or distribution of these programs or any
part thereof is punishable by law. Such violations will be prosecuted under both penal and civil law
codes and may result in heavy penalties and claims for damages.

The software will be distributed through the “KAESER Marketing Infotheque” (KMI) or per
download. Downloaded programs are packed as zip files. These have to be unpacked with a
standard Zip program (e.g. WinZip).

What is needed?

• Notebook with Windows 95/98/2000, NT or XP.


Please refer to the technical information TI 08-38 for more details. Compatibility with
Windows Vista has not yet been examined.
Note: WINDOWS ME is not supported.

• A null modem cable (material number 7.5746.1) with a COM1 or COM2 interface
plug for the notebook and a 9-pole SUB-D plug for Sigma Control
DTE DTE
Handshake
1 4
Data
2 3
Data
3 2
Handshake
4 1
Ground
5 5

6 6
Handshake
7 8
Handshake
8 7

• If no serial RS232 interface is available on the notebook/PC then a PCMCIA adapter


is needed.
The adapter is available from KAESER under material number 7.7772.0

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 3 of 8

How is the update installed on the PC?


The software is automatically included on all Kaeser notebooks under the address
D:\Docs\SC_Update.
Otherwise the software can be demanded and will be provided via download as a zip-file. These
have to be unpacked with a standard ZIP program (e.g. WinZip), available in the Internet as
freeware.

How long does the update take?

– approx. 15 minutes
The compressor cannot be operated during this period.

Procedure:

1. Find out where to switch off the power supply to Sigma Control. It is simplest on European
compressors to use the equipment circuit breaker Q0 in the control cabinet.

2. Press the EMERGENCY STOP button.

3. Connect the notebook to Sigma Control via the RS232 interface.

4. Start the “Update_SCFirmware_V2” program from the desktop or the folder in which the
software was installed. Close all other programs before starting.

Make sure that the notebook/PC does not switch to standby during the update.

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 4 of 8

5. Confirm with OK.

6. Select the interface

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 5 of 8

7. Log files
The progression of each update is written to a log file. The log files have the filename
“KAESER SigmaControl FW Updater“. If several updates are carried out without deleting
the old log files, they are automatically numbered. The current file is not given a number.
The software automatically opens a folder for the log files, if required. If this is not needed,
another path can be selected. We recommend that the log file is permanently saved to a
suitable folder should technical advice be needed later.

8. When all the settings are completed, start the update.

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 6 of 8

9. Switch the control voltage in the compressor off and on again. This is necessary to
establish data flow synchronisation between the PC and Sigma Control.

10. The software automatically detects which firmware is installed in Sigma Control. If a version
is installed in the controller for which no update is intended, this is automatically detected
and the update is aborted.

11. If the detection check is successful, the existing firmware is automatically replaced by the
current version. The successful update is confirmed by the message below.

12. Disconnect the communication cable and unlatch the EMERGENCY STOP pushbutton.
Start the compressor again afterwards.

13. Check the new firmware version on the display during a reboot.

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 7 of 8

14. Procedure at a fault:


• Check the cable connections
• Start the update again

Send the log file to service support per email with any queries. In addition, information on
the operating system, the null modem cable (manufacture, pin connections) and the PC
used is required.

15. Data maintenance in SAP


Enter the new firmware version in the Equipment Classification for Sigma Control. Please
maintain these data correspondingly or pass on the data to your responsible Kaeser
subsidiary.

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006
QEM-Sect.: R:\Service
Technical Information Support\Technik\TechInfo\01
-Technische
No. 06-28e Info\Englisch\06-28e_Sigma
Control Firmware
update_Entwurf 12-2008.doc
Page 8 of 8

Create an additional service message. Save the log file in message plain text using CTRL
C and CTRL V.

Created (name/department) Approved Release Date


Dreilich/Bathe/Service Support Dr. Preuße 11. Dez. 2008
ServSupp-Preuße/QEM/F-190710-1-Technical Information/ 14. Feb. 2006