HW_2_Ali
A.2.9
Known: Pwork = 125 bar; Pmax = 200 Bar; Accumulator powerpack = 90%
Period (s) Required flow rate (l/s) Flowrate provided by pump Volume in & out
accumulator (l)
0-5 0,75 0,25 OUT (0,5)(5) =2,5
5 - 10 0 0,25 IN (0,25)(5) = 1,25
10 - 15 0,5 0,25 OUT (0,25)(5) = 1,25
15 - 25 0 0,25 IN (0,25)(10) = 2,5
25 - 30 0,25 0,25 IN (0)(5) = 0
Flow rate (l/s)
0,7
0,6
0
0 5 10 15 20 25 30 35 Time (s)
2,5
Oil stored in accumulatyor (l)
1,5
0,5
0
0 5 10 15 20 25 30 35
Time (s)
From this graphic we know that maximum fluid volume to be stored in accumulator is 2,5 l#
Assuming that V1, V2, V3 is fluid volume at these levels of pressure respectively,
V3 – V2 = 2,5 l