DALINO COMMERCIAL BUILDING - STRUCTURAL PLAN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

30 BAR. DIA. 40 30 BAR. DIA.

CONSTRUCTION NOTES
CONSTRUCTION NOTES ARE SUPPLEMENTAL TO AND FORM PART OF THE PLANS,
DRAWINGS & SPECIFICATIONS. WHERE DETAILS OR REQUIREMENTS ARE NOT
C. CONCRETE SLABS F. CONCRETE COLUMNS & PEDESTALS I. CONCRETE SLAB OPENINGS
1. ALL SLAB REINFORCEMENT SHALL BE 20mm CLEAR MINIMUM FROM BOTTOM AND FROM

D/3
COVERED BY THE PLANS OR SPECIFICATIONS, THESE GENERAL CONSTRUCTION 1. FOR ALL TIED COLUMNS AND PEDESTALS, PROVIDE EXTRA 4 SETS OF TIES AT 100 mm O.C. 1. OTHERWISE SPECIFIED, OPENINGS ON SUSPENDED SLABS SHALL HAVE ADDITIONAL
NOTES SHALL BE USED INSOFAR AS THEY ARE APPLICABLE TO SATISFY REQUIRE- TOP OF SLAB. FOR COLUMN REINFORCEMENTS JUST ABOVE THE FLOOR, JUST BELOW THE GIRDER AND REINFORCEMENT AS SHOWN BELOW:

D/3
MENTS OF GOOD CONSTRUCTION PRACTICE. IN CASE OF QUESTIONS ARISING FROM

D
2. UNLESS OTHERWISE DETAILED, IN CONTINUOUS SLABS HAVING SAME REINFORCEMENT AT CONSTRUCTION JOINTS.
THE INTERPRETATION OF OR CONFLICT WITH OTHER DOCUMENTS, THE ATTENTION RUNNING IN ONE DIRECTION, REINFORCING BARS SHALL BE BENT UP, EXTENDED, OR CUT

D/3
OF THE OWNER/ENGINEERS MUST BE CALLED IN WRITING. 2. COLUMN AND PEDESTAL TIES SHALL BE PROTECTED BY A COVERING OF CONCRETE CAST
AS FOLLOWS: 12mmØ x 1.00 m LONG DIAGONAL BAR
MONOLITHICALLY WITH THE CORE WITH MINIMUM THICKNESS OF 38 mm AND NOT LESS THAN
@ MID-DEPTH OF SLAB AT ALL CORNERS
A. GENERAL 1-1/3 TIMES MAXIMUM SIZE OF COARSE AGGREGATE.
MAIN REINFORCEMENTS WHERE JOINT IS AT POINT OF
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS TO BE CONTINUOUS STRESS, PROVIDE SHEAR RODS
OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET G. BEAMS AND GIRDERS (TOP & BOT. BARS) BEAM WITH ENGINEERS APPROVAL
SPECIAL CONDITIONS.
LONGITUDINAL TRIMMER BAR
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL 1. TYPICAL BAR BENDING AND CUTTING DETAILS FOR BEAMS AND GIRDERS SHALL BE AS SHOWN 25
(TOP & BOTTOM)
STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED IN FIGURE BELOW:
FOR ENGINEER'S APPROVAL BEFORE FABRICATION.

t/3 t/3
t/3
3/4 EMBEDMENT LENGTH
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN. LENGTH IN TABLE 'A' TRANSVERSE TRIMMER BAR
CHECK WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE
SEE TABLE 'A' (TOP & BOTTOM)
SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE. INDICATED DIMENSIONS SHALL FOR LENGTH
GOVERN AND DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION OF EMBEDMENT (ALL AROUND) 10mmØ x 1m LONG @ 300 O.C.
PURPOSES. OPENING NOTE:
3. IF SLABS ARE REINFORCED BOTHWAYS, BARS ALONG THE SHORTER SPAN SHALL BE PLACED MAIN REINFORCEMENTS
OMIT TRIMMER BARS WHERE
4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE BELOW THOSE ALONG THE LONG SPAN AT THE CENTER AND OVER AT THE SUPPORTS. FOR TO BE CONTINUOUS
OPENING IS FRAMED BY BEAM.
SHORINGS AND BRACING TO THE STRUCTURE FOR ALL LOADS THAT MAYBE THE REINFORCING BARS NEAR THE SUPPORTS, THE SPACING OF THE BARS AT THE COLUMN
IMPOSED DURING CONSTRUCTION. STRIPS SHALL BE APPROXIMATELY ONE AND A HALF (1-1/2) THAT IN THE MIDDLE STRIPS BUT SEE TABLE 'B' WHEN COUNTED FOR SLAB
FOR LENGTH COMPRESSION EXTEND
5. IN REFERENCE TO OTHER DRAWINGS, SEE ARCHITECTURAL DRAWINGS FOR IN NO CASE GREATER THAN TWO AND A HALF (2-1/2) TIMES THE SLAB THICKNESS NOR 450mm. OF EMBEDMENT 20xDIA. BEYOND OPPOSITE
DEPRESSIONS IN FLOOR SLABS, OPENINGS IN WALLS AND SLABS, INTERIOR 4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN TENSION FACE OF SUPPORT
IN TWO WAY SLABS, EXTEND TYPICAL SLAB AND BEAM
BARS UP TO BEAM SUPPORT
PARTITIONS, LOCATION OF DRAINS, ETC. AND SHALL NOT BE LESS THAN 0.0025xBT, AND AS FOLLOWS: EXTERIOR COLUMN INTERIOR COLUMN EXTERIOR GIRDER CONSTRUCTION JOINT DETAIL
SUPPORT SUPPORT SUPPORT
6. IN CASE OF DISCREPANCIES AS TO THE LAYOUT DIMENSIONS AND ELEVATIONS SEE TABLE 'B' FOR
BETWEEN THE STRUCTURAL PLANS AND OTHER DRAWINGS. THE CONTRACTOR SCHEDULE OF MINIMUM SLAB REINFORCEMENT LENGTH OF LAPPED SPLICE
SHALL NOTIFY BOTH THE STRUCTURAL ENGINEERS AND THE OWNER'S REPRESENT- 2. SPLICES SHALL BE SECURELY WIRED TOGETHER AND SHALL LAP OR EXTEND IN
ATIVE OR SITE ENGINER IN WRITING BEFORE PROCEEDING WITH AFFECTED WORK.
THICKNESS MINIMUM TEMPERATURE BARS ACCORDANCE WITH TABLE-A OR B.
100 mm
J. EMBEDDED PIPES IN CONCRETE 40 BAR DIA 40 BAR DIA
B. CONCRETE AND REINFORCEMENT 10mmØ @ 275mm O.C. EACH WAY
TABLE - A

DEPRESSION
112.5 mm 10mmØ @ 238mm O.C. EACH WAY 1. ALL EMBEDDED PIPES FOR UTILITIES, ETC. SHALL BE MAXIMUM 100mm DIAMETER SINGLE

D=FOR BEAM

VERIFY
TENSION BARS EMBEDMENT LENGTH & LAP SPLICES (IN CENTIMETERS)

t=FOR SLAB
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST BUILDING RIGID GALVANIZED IRON PIPE UNLESS OTHERWISE SPECIFIED OR APPROVED IN WRITING
CODE OF AMERICAN CONCRETE INSTITUTE (ACI-318) FOR REINFORCED CONCRETE 125 mm 10mmØ @ 212mm O.C. EACH WAY
fc'= 20.7 MPa (3000 psi) fc' = 17.2 MPa (2500 psi) BY THE STRUCTURAL ENGINEER.
& STRUCTURAL STEEL WORK SHALL CONFORM WITH THE LATEST EDITION OF THE 137.5 mm BAR SIZES
10mmØ @ 188mm O.C. EACH WAY (mm) 2. SUCH PIPES WHEN SO EMBEDDED SHALL NOT TAKE UP MORE THAN FOUR (4) PERCENT
A.I.S.C. SPECIFICATIONS IN SO FAR AS THEY DO NOT CONFLICT WITH THE REQUIRE- EMBEDMENT LAPPED EMBEDMENT LAPPED OF THE GROSS AREA OF THE CONCRETE MEMBER.
150 mm 10mmØ @ 175mm O.C. EACH WAY
MENTS OF THE NATIONAL STRUCTURAL CODE FOR BUILDINGS AND LOCAL CODES. 30 30 30 30
Ø10 3. TYPICAL DETAIL OF PIPE SLEEVES THROUGH CONCRETE IS SHOWN AS FOLLOWS:
5. UNLESS OTHERWISE NOTED IN THE PLANS, ALL BEDDED SLABS SHALL BE REINFORCED WITH Ø12 30 36 30 30
2. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE
10mmØ REBAR AT 250 mm O.C. EACH WAYAT CENTER OF SLAB, AND CONSTRUCTION JOINTS
END OF TWENTY EIGHT (28) DAYS WITH CORRESPONDING MAXIMUM SIZE FOR SAME SHALL NOT BE MORE THAN 8 METERS APART. Ø16 36 45 30 43
AGGREGATE AND SLUMPS AS FOLLOWS: STIRRUPS 2t=FOR SLAB
6. PROVIDE EXTRA REINFORCEMENTS FOR CORNER SLAB (TWO ADJACENT DISCONTINUOUS Ø20 36 55 39 61
EDGES AS SHOWN BELOW). D=FOR BEAM
LOCATION 28 DAYS STRENGTH MAX. AGGREGATE SIZE MAX. SLUMP Ø22 52.5 62.5 57.5 65
HORIZONTAL DIAGONAL 40 BAR DIA.
Ø25 56 95 62 105
FOUNDATION & 3000 psi (20.7 MPa) 5 in. (130 mm) (MIN)
1 in. (25 mm) Ø28
RETAINING WALLS 71 121 77 131
5-10mmØ BOTTOM BARS SP. @ 200mm O.C.
Ø32 93 158 101 172
TYPICAL DETAIL FOR BEAM

a
COLUMNS & BEAMS 3/4 in. (19 mm) 5 in. (130 mm)
3000 psi (20.7 MPa)
ON GROUND Ø36 151 179 128 218 OR SLAB CHANGE SOFFIT
SUSPENDED BEAMS 3000 psi (20.7 MPa) 3/4 in. (19 mm) 5 in. (130 mm)

SUSPENDED SLABS 3000 psi (20.7 MPa) 3/8 in. (10 mm) 5 in. (130 mm) TABLE - B
5-10mmØ TOP BARS SP. @ 200mm O.C. COMPRESSION BARS EMBEDMENT LENGTH & LAP SPLICES (IN CM)
CURBS AND SLAB 12mm THK. EXPANSION JOINT
2500 psi (17.2 MPa) 1 in. (25 mm) 4 in. (100 mm) 7. ON SLABS ON GRADE: VERTICAL STIRRUPS WITH MASTIC FILLER
ON GRADE BAR SIZES fc'= 20.7 MPa (3000 psi) fc' = 17.2 MPa (2500 psi)
a. ALL SLABS ON GRADE SHALL BE DESIGNED WITH A MINIMUM WATER CEMENT RATIO OF SLEEVE
3/8 in. (10 mm) 5 in. (130 mm) (mm)
MOULDINGS 3000 psi (20.7 MPa) OF 0.42. ANY DECREASE IN WORKABILITY SHALL BE COMPENSATED USING A PLASTICIZER. EMBEDMENT LAPPED EMBEDMENT LAPPED b
b. ALL SLOPES SHALL BE POURED INTEGRAL WITH SLAB OVERLAYS & TOPPING SHALL NOT Ø10 20 30 20 30 MAIN REINFORCEMENT

(DOWEL)
3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615. USE GRADE40 FOR Ø16mm BE ALLOWED UNLESS APPROVED OR SPECIFIED BY ENGINEER.
20 30 21 34

400
& SMALLER, GRADE 60 FOR REBARS Ø20mm & BIGGER. Ø12
c. CONTINUOUS WET CURING OF CONCRETE BY PONDING SHALL BE DONE FOR AT LEAST
ALL BARS 12mmØ AND BIGGER SHALL BE DEFORMED. BARS SMALLER THAN 12mmØ

t OR 1/4D
14 DAYS UNLESS OTHERWISE SPECIFIED. 23 32.5 26 42.5 1-Ø16mm VERT. BARS

t
MAY BE PLAIN BARS. Ø16
4. BARS OF REINFORCED CONCRETE EXPOSED TO THE WEATHER SHALL PREFERABLE BE Ø20 28 37.5 31 50 CHB WALL
PROTECTED AT LEAST 38mm AND IN NO CASE LESS THAN 25mm CONCRETE COVER. THIS D. FOUNDATION AND FOOTINGS Ø22 25 45 27.5 57.5 FOR SIZE AND SPACING

D
PROVISION MAY BE WAIVED WHEN ADEQUATE WATERPROOFING IS PROVIDED BUT SHALL 1. FOOTINGS WERE DESIGNED FOR A SOIL BEARING CAPACITY OF 2000 psf FOR AN EMBEDMENT OF HOR. & VERT. BARS
IN NO CASE BE LESS THAN 20mm. Ø25 37 51 41 67.5 SEE CONSTRUCTION NOTES
OF 2 METERS & 1470 psf FOR AN EMBEDMENT OF 1.5 METERS OR LESS.
Ø28 42 57.5 77 75
5. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE 2. FOOTINGS SHALL REST ON NATURAL SOIL 1.50 METERS BELOW GRADE LINE, UNLESS
DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS OTHERWISE INDICATED BY THE ENGINEER. NO PART OF THE FOUNDATION SHALL REST Ø32 46 64 52 85 CORNER WALL
SLEEVES FOR UTILITY
OTHERWISE SHOWN OR NOTED. ON FILL UNLESS REPLACED WITH 1.0 m DEEP WELL-COMPACTED CRUSHED ROCK FILL.. PIPES MAX. 1/3D
Ø36 51 72 - -
COMPACTION OF ALL SUBGRADE SHALL BE AT 95% OF MDD BASED ON ASTM D698.
6. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS. 12mm THK. EXPANSION JOINT
3. IF BEAM REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FROM THE BAR TO THE
3. THE CONTRACTOR SHALL NOTIFY IN WRITING THE ENGINEER AFTER FOOTING PROVIDE 3-Ø10 EXTRA STIRR. WITH MASTIC FILLER
FARTHER FACE OF THE WALL SHALL NOT BE LESS THAN 25mm. EMDEDMENT LENGTH SHALL EACH SIDE OF SLEEVES.
SUSPENDED SLABS 3/4 in. (19mm) EXCAVATION HAS BEEN COMPLETED AND PRIOR TO CONCRETING TO CONFIRM
BE AS SHOWN IN TABLE-A & TABLE-B ACCORDINGLY.
1 1/2 in. (38mm) THE DESIGN SOIL BEARING CAPACITY AND IF ACTUAL SOIL PROPERTY APPEARS
SLAB ON GRADE WEAKER THAN ASSUMED. 4. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mm DIAMETER BAR
WALLS ABOVE GRADE 1 in. (25mm)
4. THE CONTRACTOR SHALL HAVE THE RESPONSIBILITY TO DEVISE & IMPLEMENT SEPARATORS SPACED ABOUT 90 cm ON CENTER. IN NO CASE SHALL THERE BE LESS THAN

(DOWEL)
BEAM STIRRUPS AND COLUMN TIES 1 1/2 in. (38mm) EXCAVATION PROCEDURES THAT WILL ENSURE SAFETY OF LIFE & PROPERTY. TWO (2) SEPARATORS BETWEEN LAYERS OF BARS.

400
WHERE CONCRETE IS EXPOSED TO EARTH CONTRACTOR SHALL ENSURE THAT ALL EXISTING STRUCTURES ARE PROPERLY AND REINFORCING BAR FOR SLEEVES
2 in. (50mm) 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS SHALL BE 18.75mm CLEAR FOR 1-Ø16mm VERT. BARS
BUT POURED AGAINST FORMS ADEQUATELY SUPPORTED AGAINST SETTLEMENT OR MOVEMENT DURING CONSTRUCTION.
JOISTS & 37.50mm CLEAR FOR BEAMS AND GIRDERS.
5. MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE 75 mm CLEAR OPENING REINFORCING BARS
WHERE CONCRETE IS DEPOSITED HORIZONTAL STIRRUP
3 in (75mm) FOR CONCRETE DEPOSITED AGAINST THE GROUND AND 50 mm CLEAR IF DEPOSITED 6. GENERALLY NO SPLICE SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES DIAMETER
DIRECTLY AGAINST EARTH DIAGONAL VERTICAL
AGAINST A FORMWORK. OCCUR. SPLICES WHERE SO PERMITTED SHALL BE AS INDICATED IN TABLES A & B. WELDED SPLICES FOR SIZE AND SPACING
SHALL DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. Ø= < 100 2 - Ø12 2 - Ø12 - - OF HOR. & VERT. BARS
8. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY 6. FILL AND SUBGRADE UNDER SLABS AND FOOTINGS SHALL BE COMPACTED TO A MINIMUM SEE CONSTRUCTION NOTES
POSITIONED AND SECURED IN PLACE PRIOR TO PLACING OF CONCRETE. 95% OF MDD (MAXIMUM DRY DENSITY) BASED ON ASTM D698. NO MORE THAN 50% OF THE BARS AT ANY ONE SECTION SHALL BE ALLOWED TO BE SPLICED THEREIN. < 2 - Ø12 2 - Ø12 2 - Ø12 Ø12 - @50
150 < Ø = 150
CHB WALL
9. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, H. LINTEL BEAMS IN CHB WALLS < 200
150 < Ø = 2 - Ø16 2 - Ø16 2 - Ø16 Ø12 - @50
TOOLS, EQUIPMENTS AND MECHANICAL BASES THAT ARE REQUIRED BY THE
ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. E. MASONRY AND CONCRETE BLOCKS 1. REINFORCEMENTS FOR CONCRETE LINTEL BEAMS FOR OPENINGS (DOORS & WINDOWS) SHALL BE 200< Ø <
= 250 2 - Ø20 2 - Ø16 2 - Ø16 Ø12 - @50 INTERSECTION WALL
1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT AS FOLLOWS:
10. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN (7)
NOT TO EXCEED 80 PCF. DOWEL BARS TO MATCH
CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP, LINTEL IN BLOCK WALLS (PER 100mm THICKNESS)
FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. FOR LOAD BEARING TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE CHB HOR. BARS
STRENGTH OF 6.90 MPa SHALL BE DEVELOPED. CLEAR SPAN 'L' TOTAL LENGTH MIN. fc' HEIGHT OF REINFORCEMENT
12mm THK. EXPANSION JOINT
11. STRIPPING OF FORMS AND SHORES SHALL BE DONE AFTER A MINIMUM AMOUNT OF (m) (L + 0.40 , m) MPa LINTEL (cm)
2. PROVIDE 1-Ø10mm VERTICAL BAR AT CORNERS, INTERSECTIONS, END OF BOTTOM TOP K. STRUCTURAL STEEL WITH MASTIC FILLER

LOCATION TIME WALLS AND EACH SIDE OF OPENINGS. 1.20 1.80 13.80 20 1-10mmØ 1-10mmØ
1. ALL STRUCTURAL STEEL TO BE USED FOR FABRICATION AND ERECTION SHALL
3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200 mm) ON EACH SIDE OF 1.50 1.90 13.80 20 1-10mmØ 1-10mmØ COMPLY WITH ALL THE PERTINENT PROVISIONS OF AISC.
FOUNDATION 24 HRS.
MASONRY WALL OPENING. 1.80 2.20 13.80 20 1-10mmØ 1-10mmØ
SUSPENDED SLABS EXCEPT WHEN 2. ALL STRUCTURAL STEEL SHAPES & PLATES SHALL CONFORM TO STD. REQUIREMENTS
8 DAYS 4. MASONRY WALL REINFORCEMENTS SHALL BE AS FOLLOWS, UNLESS NOTED: 2.10 2.50 17.20 20 1-16mmØ 1-10mmØ
ADDITIONAL LOADS ARE IMPOSED OF AISC FOR ASTM A36 STEEL. MIN. YIELD STRENGTH = 248 MPa OR 36000 psi.
WALL THICKNESS VERTICAL REINFORCEMENT HORIZONTAL REINFORCEMENT 2.40 2.80 17.20 20 1-16mmØ 1-10mmØ 3. ALL COLD FORMED STEEL SHAPES SHALL CONFORM TO STD. REQUIREMENTS
WALLS 18 HRS. R.C. COLUMN OR WALL
2.70 3.10 17.20 20 1-20mmØ 1-10mmØ OF AISC FOR JIS G3141 SPCC. MIN. YIELD STRENGTH = 227 MPa OR 33000 psi.
8" (200 mm) Ø12 @ 400 mm Ø10 @ 600 mm (3 LAYERS) INTERSECTING R.C. COLUMN OR WALL
BEAMS 14 DAYS 3.00 3.40 17.20 30 1-16mmØ 1-10mmØ 4. ALL PIPES & TUBES SHALL CONFORM TO STD. REQUIREMENTS OF ASTM A53.
6" (150 mm) Ø10 @ 600 mm Ø10 @ 600 mm (3 LAYERS)
COLUMNS 3 DAYS 3.30 3.70 17.20 30 1-16mmØ 1-10mmØ MIN. YIELD STRENGTH = 248 MPa OR 36000 psi.
4" (100 mm) Ø10 @ 600 mm Ø10 @ 600 mm (3 LAYERS) 1-Ø16mm VERT. BARS
12. ON LAP SPLICE AND HOOKS: 3.60 4.00 17.20 30 1-16mmØ 1-10mmØ 5. ALL SHOP AND FIELD WELDS SHALL CONFORM WITH AWS STRUCTURAL WELD CODE D1-1.
5. REINFORCING BARS SHALL BE LAPPED WITH A MINIMUM OF 30 BAR DIAMETERS NOTE : USE 10mmØ STIRRUPS SPACED @ 200mm O.C. USE E60XX ELECTRODE. WELDING SHALL BE PERFORMED BY QUALIFIED WELDERS.
a. ALL BARS FOR BEAMS AND COLUMNS SHALL BE LAPPED WITH A MIN. LENGTH
OF 30 x BAR DIAMETER. WHERE SPLICED DOWELS FROM CONCRETE FOOTINGS OR SLABS SHALL EXTEND INTO 'L' 6. ALL BOLTS, NUTS AND WASHERS SHALL BE HIGH-STRENGTH & CONFORM TO A307
'L'
b. ALL BARS FOR SUSPENDED SLABS SHALLE BE SPLICED WITH A MIN. LENGTH THE BLOCK WALL AT A MINIMUM OF 30 BAR DIAMETERS. REBARS TO BE TIED PROPERLY OR A325 UNLESS OTHERWISE INDICATED. ANCHOR BOLTS SHALL LIKEWISE BE OF
WITH G.I. WIRES. 0.20 0.20 0.20 0.20
OF 40 x BAR DIAMETER. EQUAL STRENGTH AS A325 BOLT OF THE SAME SIZE .
c. NO MORE THAN 50% OF THE BARS SHALL BE SPLICED WITHIN THE REQUIRED 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FOR SIZE AND SPACING
LAP LENGTH. FILLED WITH CONCRETE GROUT (REFER TO SPECIFICATIONS ). OF HOR. & VERT. BARS
d. 90° HOOKS WITH 12 x BAR DIAMETER EXTENSION (SPECIFICALLY FOR BEAMS) 7. WELD HORIZONTAL BARS FOR CHB WALL TO STEEL COLUMNS WHERE APPLICABLE. SEE CONSTRUCTION NOTES
SHALL BE ANCHORED INTO THE FAR FACE OF THE COLUMN.
10mmØ BAR AROUND WINDOW OPENING OR END WALL
13. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION,
DOOR OPENING
REHANDLING OR FLOWING. ADEQUATE VIBRATION OR APPROVED EQUAL METHOD 12mmØ BARS ON SIDES OPENING WINDOW OPENING (TYP.) TYPICAL MASONRY WALL
SHALL BE DONE DURING DEPOSITION OF CONCRETE. OF DOOR OPENING
14. SAMPLING FOR COMPRESSIVE STRENGTH TESTS SHALL BE MADE IN ACCORDANCE
CONNECTION DETAILS

CONTRACTOR ENGINEER PROJECT TITLE PROJECT OWNER DESIGNED BY: DENISE SHEET CONTENT DATE
CAD BY: DALINO
PROPOSED TWO STOREY GENERAL NOTES
CHECKED BY: SHEET NO.
COMMERCIAL BUILDING
APPROVED BY:
REGISTRATION No.: P.T.R. No.: LOCATION ADDRESS DATE: REVISIONS REMARKS S-1
TIN No.: ISSUED ON / AT :
A B B' b B" C D E
23170

5793 5793 5793 5793

1500 1500 1500 3650

C1/F1 WF-1 C1/F1 WF-1 C1/F1 WF-1 C1/F1 C1/F1


01
+0.35m +0.35m +0.35m

2000
ELEV ELEV ELEV

1800
WF-1

WF-1

WF-1

WF-1

WF-1

WF-1

WF-1
FROM FROM FROM

2878
NGL NGL NGL
01'
C1/F1 WF-1 C1/F1 WF-1 C1/F1 WF-1 C1/F1
+0.40m ELEV +0.40m ELEV +0.40m ELEV +000 ELEV

5755
02 FROM NGL FROM NGL FROM NGL FROM NGL

WF-1
WF-1

WF-1

WF-1
02'
C1/F1 C1/F1 C1/F1 C1/F1 C1/F1
03
WF-1 WF-1 WF-1

1 FOUNDATION PLAN
S-2 SCALE 1:125

A B C D E
23170

5793 5793 5793 5793

B-1 B-1 B-1 B-1


01
2878

B-2

B-1 B-1 B-1 CB-1


5755

B-3
02
2878

B-2

B-1 B-1 B-1 B-1


04

2 SECOND FLOOR FRAMING PLAN


S-2 SCALE 1:125

CONTRACTOR ENGINEER PROJECT TITLE PROJECT OWNER DESIGNED BY: DENISE SHEET CONTENT DATE
CAD BY: DALINO
PROPOSED TWO STOREY FOUNDATION PLAN
CHECKED BY: SEC. FLOOR FRAMING PLAN SHEET NO.
COMMERCIAL BUILDING
APPROVED BY:
REGISTRATION No.: P.T.R. No.: LOCATION ADDRESS DATE: REVISIONS REMARKS S-2
TIN No.: ISSUED ON / AT :
1500
A B C D E 300 VERT. BARS WITH
23170
10mm Ø TIES,
5793 5793 5793 5793
4 of 16mm Ø deformed
reinforcing steel bars
4 of 12mm Ø deformed
reinforcing steel bars

1500

300
RB-1 RB-1 RB-1
01
RB-2
2878

10 of 16mm Ø rebars
5755

02
placed bothways
PLAN
C1/F1
RB-2
2878

800
03
RB-1 RB-1 RB-1
2 COLUMN FOOTING DETAIL
S-3 SCALE 1:40

300
ROOF BEAM

1 ROOF BEAM FRAMING PLAN


S-3 SCALE 1:125 SEE ROOF
BEAM
4.00m 3.00m SCHEDULE

3000
4 of 16mm Ø deformed
1.33m 1.33m 1.00m 1.00m reinforcing steel bars
4 of 12mm Ø deformed
reinforcing steel bars

4" CHB above ground with


10mmØ horizontal rebars
spaced every 3 layers and
10mmØ vertical rebars spaced 150

350
0.70m 0.30m 0.30m 0.70m 0.45m 0.30m 0.30m 0.45m
at 0.80m o.c. BEAM

Raised Ground Line


BEAM
BEAM ELEVATION
0.40m

SCHEDULE

3000
Natural Ground Line 4 of 16mm Ø deformed
reinforcing steel bars
0.25m 0.25m 0.20m 0.20m
4 of 12mm Ø deformed
reinforcing steel bars
0.15

2 of 10mmØ continuous rebars with 0.35m 0.35m 0.30m 0.30m

100
200
10mmØ Ties spaced @ 0.30m o.c.
±0.05m Gravel Course END SPAN MID SPAN
compacted END SPAN MID SPAN VERT. BARS WITH

±1000
WF-1 BEAM SECTION ROOF BEAM SECTION 10mm Ø TIES,
5@ 50mm , 5@100mm,
5@150mm, REST
0.20 @200mm O.C

4 BEAM DETAILS 10 of 16mm Ø rebars


placed bothways

300
3 WALL FOOTING DETAIL S-3 SCALE 1:30
5 COLUMN DETAIL
S-3 SCALE 1:40 SCALE 1:75 ±0.10mm Gravel course
S-3
SECTION
CONTRACTOR ENGINEER PROJECT TITLE PROJECT OWNER DESIGNED BY: DENISE SHEET CONTENT DATE
CAD BY: DALINO ROOF FRAMING PLAN
PROPOSED TWO STOREY FOOTING DETAIL
CHECKED BY: BEAM DETAIL SHEET NO.
COMMERCIAL BUILDING
APPROVED BY: COLUMN DETAIL
REGISTRATION No.: P.T.R. No.: LOCATION ADDRESS DATE: REVISIONS REMARKS S-3
TIN No.: ISSUED ON / AT :
4.00m

Ø 10MM STRAIGHT TOP


1.33m

AND BOTTOM BARS 12 Ø @ 125mm O.C.


@ 300 MM B.W
12 Ø @ 150mm O.C.
BOTTOM BARS TOP BARS

12 Ø @ 125mm O.C. 10 Ø @ 200mm O.C. STAIR BEAM


TOP BARS
10 Ø NOSING
12 Ø @ 250mm O.C.
TOP BARS

1.20m
12 Ø @ 125mm O.C.
0.10 2 of 10mmØ Top & Bottom TOP BARS
Bars with C-Ties 10mmØ
12Ø @ 150mm O.C. TEMP. BARS
spaced at every 0.20m
0.15

12Ø @ 250mm O.C. TEMP. BARS


150 mm thk.
10Ø @ 250mm O.C. TEMP. BARS
STAIR BEAM
BENT BARS @ L/3
FROM SUPPORT

3.50m

1.10m
NOTE: PROVIDE LINTEL BEAM ON ALL DOOR AND
WINDOW HEADERS AROUND PERIMETER WALLS. 10Ø @ 200mm O.C.
TOP & BOTTOM BARS
10Ø @ 200mm O.C.
LINTEL BEAM TOP & BOTTOM BARS

SUPPORT MIDSPAN
TIES:
200 200
10mm Ø Def. Bars spaced every 0.20m 2-16mmØ
3-16mmØ

1.20m
12 mm Ø @ 125mm O.C.

300

300
1 LINTEL BEAM PLAN 150 mm

800
2-16mmØ 10 mm Ø @ 200mm O.C.
3-16mmØ
S-4 SCALE 1:16

200
10mm Ø BENT BARS @ L/3
10mm Ø TOP AND BOTTOM BARS
STIRRUP: 10mmØ - 1050, 60100 REST @ 200mm O.C.
SPACED @ 300mm B.W.

4.00m STAIR BEAM


1.33m 1.34m 1.33m
600

120mm. THK. SLAB 4 STAIR DETAIL 10mmØ @ 300mm O.C.


4-12mm Ø CONTINOUS BARS

S-4 SCALE 1:50

L/4 L/4
MIDSPAN/COLUMN STRIP
TOP BARS LONG DIRECTION
2 SLAB DETAIL
S-4 SCALE 1:50

SLAB SCHEDULE
STEEL DECK
L/6 BOTTOM BARS SHORT DIR. LONG DIRECTION SHORT DIRECTION
THICKNESS BAR
DESCRIPTION SUPPORT MIDSPAN SUPPORT MIDSPAN REMARKS
(mm) DIAMETER
LONG DIRECTION BOT. BARS TOP BARS BOT. BARS TOP BARS BOT. BARS TOP BARS BOT. BARS TOP BARS
S-1 100 10mmØ 300 O.C. 300 O.C. 150 O.C. 150 O.C. ONE-WAY SLAB
MIDSPAN/COLUMN STRIP
S-2 100 10mmØ 150 O.C. 300 O.C. 150 O.C. 150 O.C. TWO-WAY SLAB
L/4 L/4 TOP BARS LONG DIRECTION
NOTE: A.) USE STEEL DECK

SHORT DIR.
B.) USE GRADE 33 REBARS
C.) USE 3000 PSI CONCRETE
STEEL DECK D.) FOR ADJACENT SIDES OF SLAB USE THE CLOSER SPACING
LONG DIR.
SCHEDULE OF BEAM
BOTTOM BARS SHORT DIR.

SHORT DIRECTION END SPAN MID SPAN

11 10
3 SLAB SECTION DETAIL 5793

2878 2 10
S-4 SCALE 1:50
5755 1 10

10
CB 1 5793 1
10
5793 6
2878 2 10

CONTRACTOR ENGINEER PROJECT TITLE PROJECT OWNER DESIGNED BY: DENISE SHEET CONTENT DATE
CAD BY: DALINO LINTEL BEAM PLAN
PROPOSED TWO STOREY SLAB DETAIL
CHECKED BY: SLAB SECTION DETAIL SHEET NO.
COMMERCIAL BUILDING
APPROVED BY: STAIR DETAIL
REGISTRATION No.: P.T.R. No.: LOCATION ADDRESS DATE: REVISIONS REMARKS S-4
TIN No.: ISSUED ON / AT :