FORMAT NO: QA-FR-04

REVISION NO: 0

DATE: 21-06-2017

MATERIAL TEST CERTIFICATE AS PER EN -10204 / 2004 / TYPE 3.1


PROJECT TC NO.: ASPL/1096/ T-027 DATE :- 05/10/2023

CUSTOMER NAME

PO. NO.

PRODUCT :- AUSTENITIC STAINLESS STEEL SEAMLESS PIPES

SPECIFICATION :- ASTM A312/A312M-22 TP 304L

Hydro Test Pressure


Length In Qty. Qty.
Sr. No. Heat No. Size Pressure Results Holding End Finish
Mtrs In Nos. In Mtrs
(PSI) Time

1 ASPL23146 O.D.10.30 MM X 1.73 MM W.THK. 5.0 - 7.0 561 3506.35 2500 Satisfactory 5 - 10 SEC. PE

2 ASPL23159 O.D.13.70 MM X 2.24 MM W.THK. 5.0 - 7.0 410 2575.48 2500 Satisfactory 5 - 10 SEC. PE

3 ASPL23170 O.D.13.70 MM X 1.65 MM W.THK. 5.0 - 7.0 425 2678.61 2500 Satisfactory 5 - 10 SEC. PE

CHEMICAL COMPOSITION %

C% Si % Mn % P% S% Ni % Cr %
Sr. No. Heat No.
0.035 1.00 2.00 0.045 0.030 8.00 Min. 18.00 Min.
Max. Max. Max. Max. Max. 13.00 Max. 20.00 Max.

1 ASPL23146 0.021 0.42 1.24 0.021 0.007 8.32 18.71

2 ASPL23159 0.023 0.35 1.18 0.023 0.008 8.54 18.61

3 ASPL23170 0.019 0.37 1.05 0.026 0.008 8.46 18.55

MECHANICAL TEST
Yeild Strength Elongation % Hardness
Tensile Strength (Mpa.) Flattening
Sr. No. Heat No. (Mpa.) GL = 50mm HRB Macro Test Flange Test Flaring Test
485 Min. Test
170 Min. 35 Min. 95 Max.

Confirming
1 ASPL23146 603.41 256.34 47.22 76, 78, 80 Satisfactory NA NA
Seamless

Confirming
2 ASPL23159 596.75 237.19 52.17 72, 74, 74 Satisfactory NA NA
Seamless

611.23 252.40 Confirming


3 ASPL23170 50.85 70, 72, 74 Satisfactory NA NA
Seamless

HEAT TREATMENTS :- SOLUTION ANNEALED AT 1040° C TO 1080° C TEMPERATURE & RAPIDLY WATER QUENCHED.

REMARK:-
1. 100% Visual Checked - Found Satisfactory.
2. 100% Dimensions as per ASME B36.19M - Found Satisfactory.
3. 100% PMI Checked - Found Satisfactory.
4. 100% Pickling & Passivation Carried out - Found Satisfactory.
5. Corrosion Test - Satisfactory.
6. This is to Certify That above Pipes also Meet The Genernal Requirement of Specification ASTM A - 999
7. Material free from mercury and radioactive contamination.

INSPECTORS / CLIENT'S SIGN INSPECTION AUTHORITY MANAGER - QUALITY CONTROL


The Material was Manufactured, Tested & Inspected in accordance with Specification & P.O Requirements.
Office & Works
Office : 7 , Bhanshali House , 1 st Floor , 9 Th Khetwadi Line , Mumbai - 400 004 / Tel - 022 23862124 / 022 6636 2233 / 022 23879241
Works : F - 1/6 - 1 /8 M I D C Tarapur ,Boisar (W ) , Dist - Palghar -401506 / Tel - 02525 273289 / 279063