Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PT.

EUDONIA NASIONAL
INDONESIA SALT SPRAY TEST REPORT

1. Description

Name Part SCREW WH 2X8 Plan Test 96 H


Part Code JV40220-00008 Plating Spect WHITE Cr3+
Customer PT. MABERTECH INTERINDO Time In 03/03/2023 11.00
Date
Standart JIS Z-2371 / HES D 2003-05 Time Out 07/03/2023 11.00

2. Test Condition

Item Standard Actual


o
1. Test Chamber Temp. 33.0˚C - 37.0 C 35,1 oC
2. Air Saturator Temp. 45.0˚C - 49.0oC 46,2 oC
3. Spraying Quantity 1.5 ± 0.5 ml/H 1,6 ml/H
4. Mist pressure 1.0 ± 0.5 kgf /cm2 1,4 kgf /cm2
5. Sodium Chloride 5% ± 0,5 % 5%
6. pH 6.5 - 7.2 7
Illustration / Drawing

SST Process Before Test After Test

3. Test Result

VISUAL CHECKING
NO
24 48 72 96 120 144 168 192 216 240
3 - - - - - - - -

Remarks Note :
: No White Rust Visual check after SST 96 Hours
X : Red Rust - No White Rust
: White Rust - No Red Rust

Approved Checked Inspected


Overall / Jugment

PASSED
Loca P Sumamat Kusnanto
F - QC - 15