Schneider ACB
Schneider ACB
Schneider ACB
Circuit Breakers
Class 0613
Catalog
0613CT0001
R12/19
www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and
furnished for informational use only. No part of this guide may be reproduced or
transmitted in any form or by any means (electronic, mechanical, photocopying,
recording, or otherwise), for any purpose, without the prior written permission of
Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as
is" basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Class 0613
Table of Contents
MasterPact™ Circuit Breakers .................................................................9
Introduction ................................................................................................9
Codes and Standards .................................................................................9
Features and Benefits ...............................................................................10
MasterPact NW Circuit Breaker Design ......................................................14
MasterPact NW Cradle Design ..................................................................15
MasterPact NW with ArcBlock™ Technology ..............................................16
MasterPact NT Circuit Breaker and Cradle Design ......................................17
Ratings ....................................................................................................18
Correction Factors ....................................................................................25
Shipping Weights .....................................................................................25
Energy Management ................................................................................27
Energy Management Using the Enerlin'X System........................................27
Measure.............................................................................................27
Connect .............................................................................................28
Save ..................................................................................................28
Enerlin'X Communication System Components ..........................................29
MasterPact Circuit Breakers with MicroLogic Trip Units..........................29
Displays...................................................................................................30
Power Meter Functions .............................................................................31
Display Function.......................................................................................31
Measurement Function .............................................................................32
Instantaneous RMS Measurements......................................................32
Maximum / Minimum Ammeter.............................................................32
Energy Metering .................................................................................32
Demand and Maximum Demand Values ...............................................32
Power Quality .....................................................................................32
Histories ..................................................................................................34
Maintenance Indicators .............................................................................34
Contact Wear .....................................................................................34
Circuit Breaker Load Profile .................................................................35
Management of Installed Devices ..............................................................35
FDM121 Display.......................................................................................36
Display of MicroLogic Trip Unit Measurements and Alarms ....................36
Status Indications and Remote Control .................................................37
Main Characteristics ...........................................................................38
Mounting ............................................................................................38
Connection.........................................................................................38
Navigation ..........................................................................................39
Screens .............................................................................................39
Communication Components and FDM121 Connections .......................40
FDM128 Display.......................................................................................40
Display of MicroLogic Trip Unit Measurements and Trips .......................40
Status Indications ...............................................................................41
Remote Control ..................................................................................41
Main Characteristics ...........................................................................41
Mounting ............................................................................................41
Connection.........................................................................................42
0613CT0001 3
Class 0613
Navigation ..........................................................................................42
Screens .............................................................................................42
Communication Components and FDM128 Connections .......................43
MicroLogic™ Electronic Trip Systems ...................................................46
Overview of MicroLogic Trip Systems.........................................................46
Thermal Imaging.................................................................................46
Power Supply Information .........................................................................47
Ammeter (A) Trip Unit Without 24 Vdc Power Supply at F1 and
F2......................................................................................................47
Ammeter (A) Trip Unit With 24 Vdc Power Supply at F1 and F2 ..............47
Power (P) and Harmonic (H) Trip Unit Without 24 Vdc Power Supply
at F1 and F2 .......................................................................................48
Power (P) and Harmonic (H) Trip Unit With 24 Vdc Power Supply at
F1 and F2...........................................................................................48
MicroLogic Trip Units—Overview ...............................................................49
True RMS Current Sensing..................................................................49
MicroLogic 2.0, 3.0 and 5.0 Basic Trip Units................................................51
Protection Settings..............................................................................51
MicroLogic 2.0A, 3.0A, 5.0A and 6.0A Trip Units with Ammeter ....................53
Protection Settings..............................................................................53
Ammeter Measurements .....................................................................54
Communication Network .....................................................................54
MicroLogic 5.0P and 6.0P Trip Units with Power Metering............................56
Protection Settings..............................................................................56
Configuring Alarms and Other Protection Functions...............................57
Maintenance Record ...........................................................................57
Load Shedding and Reconnection Parameters......................................58
Indication Option via Programmable Contacts .......................................58
Trip and Alarm Histories ......................................................................60
Metering.............................................................................................60
Communication Network .....................................................................61
Event Log...........................................................................................61
MicroLogic 5.0H and 6.0H Trip Units with Harmonic Metering ......................62
Metering.............................................................................................62
Waveform Capture..............................................................................63
Customized Alarm Programming..........................................................63
Event Logs .........................................................................................63
Additional Technical Characteristics for Type P and Type H Trip
Units ..................................................................................................64
MicroLogic Trip Unit Functions...................................................................64
Long-Time Trip Functions ....................................................................64
Short-Time Trip Functions ...................................................................65
Instantaneous Trip Function.................................................................65
Ground-Fault Trip Functions ................................................................65
Enerlin'X Communication Wiring System ....................................................66
Wiring System ULP .............................................................................66
Four Functional Levels ........................................................................67
Modbus Principle ................................................................................68
Ethernet Principle ...............................................................................68
COM Option in Masterpact Circuit Breakers................................................69
IFE Ethernet Interface ...............................................................................71
4 0613CT0001
Class 0613
0613CT0001 5
Class 0613
6 0613CT0001
Class 0613
0613CT0001 7
MasterPact™ Circuit Breakers Class 0613
H A 10
N X 08 U im p 12kV
U i1000V
V)
Ue (
690
/1s
50kA
z
50/60H
A
2 N BM
947- 2 N E AS
IEC EI U
EN 60947- BS C
VD E
U TE
800–3200 A MasterPact NW
Drawout Circuit Breaker 4000–6300 A MasterPact NW Drawout
Circuit Breaker
IEC Extreme
Low-Voltage Power Insulated Case IEC Rated Circuit
Atmospheric
Circuit Breaker Circuit Breaker Breaker
Conditions
IEC 68-2-1: Dry cold
ANSI C37.13 at –55°C
ANSI C37.16 IEC 68-2-2: Dry heat
UL 489 (UL Listed)
ANSI C37.17 at +85°C
NEMA AB1 IEC 60947-2
ANSI C37.50 IEC 68-2-30: Damp
CSA C22.2 No. 5 IEC 60947-3
UL 1066 (cULus heat (temp. +55°C, rel.
NMX J-266-ANCE
Listed) humidity 95%)
NEMA SG3 IEC 68-2-52 Level 2:
Salt mist
NOTE: Throughout this document, the phrase “ANSI® Certified” means the
product meets the requirements of UL 1066 and ANSI C37. When “UL®
Listed” appears, the product meets the requirements of UL 489.
0613CT0001 9
Class 0613 MasterPact™ Circuit Breakers
The 800–2000 A ANSI Low Voltage Power Circuit Breakers type L1F and
Insulated Case Circuit Breaker type LF are tested to show the arc flash hazard risk
category as referenced by NFPA® 70E.
Circuit breakers should be applied according to guidelines detailed in the National
Electrical Code® (NEC®) and other local wiring codes.
MasterPact circuit breakers are available in Square D™ or Schneider Electric™
brands.
UL File Numbers:
• MasterPact NW: E161835 Vol. 2 Sec. 1
• MasterPact NT: E161835 Vol. 2 Sec. 2
10 0613CT0001
MasterPact™ Circuit Breakers Class 0613
In addition, after fault tripping or opening the circuit breaker intentionally (using the
manual or electrical controls and with the closing coil continuously energized) the
circuit breaker cannot be closed until the power supply to the closing coil is
discontinued and then reactivated.
NOTE: When the automatic reset after fault trip (RAR) option is installed, the
automatic control system must take into account the information supplied by
the circuit breaker before issuing a new closing order or before blocking the
circuit breaker in the open position. The information is on the type of fault, e.g.
overload, short-circuit or ground fault.
Disconnection Through the Front Door: The racking handle and racking
mechanism are accessible through the front door cutout. Disconnecting the circuit
breaker is possible without opening the door and exposing live parts.
Door Escutcheon
Closing and Opening Push Buttons
Test Position
Connected Position
0613CT0001 11
Class 0613 MasterPact™ Circuit Breakers
Good Worn
Contacts Contacts
12 0613CT0001
MasterPact™ Circuit Breakers Class 0613
Ambient Temperature:
MasterPact circuit breakers can operate under the following temperature
conditions:
• The electrical and mechanical characteristics are stipulated for an ambient
temperature between -13°F (25°C) and 158°F (70°C).
• Mechanical closing of the circuit breaker (by pushbutton) is possible down to
-31°F (-35°C) and at an altitude up to +13,000 ft. (3900 m).
MasterPact circuit breakers have been tested for operation in industrial
atmospheres. It is recommended that the equipment be cooled or heated to the
proper operating temperature and kept free of excessive vibration and dust.
Operation at temperatures above 104°F (40°C) may require derating or
overbussing the circuit breaker. See the appropriate instruction bulletin and
Temperature Correction Factors, page 25 of this catalog for additional information.
Storage Temperature
Circuit breakers with trip units without LCD displays may be stored in the original
packaging at temperatures between -40°F (-40°C) and 185°F (85°C).
For circuit breakers with trip units with LCD displays, this range is -13°F (-25°C) to
185°F (85°C).
Altitude:
MasterPact circuit breakers are suitable for use at altitudes of 13,000 ft. (3900 m)
and below. See Altitude Correction Factors per ANSI C37.20.1 par. 7.1.4.1 (Table
10), page 25 for altitude correction factors.
Vibration:
MasterPact circuit breakers meet IEC 60068-2-6 Standards for vibration.
• 2 to 13.2 Hz and amplitude 0.039 in. (1 mm)
• 13.2 to 100 Hz constant acceleration 0.024 oz. (0.7 g)
Humidity:
MasterPact circuit breakers have been tested to the following:
• IEC68-2-30—damp heat (temperature +55°C and relative humidity of 95%)
• IEC 68-2-52 level 2—salt mist
The materials used in MasterPact NT and NW circuit breakers will not support the
growth of fungus and mold.
0613CT0001 13
Class 0613 MasterPact™ Circuit Breakers
V Trip Unit
W Accessory Cover
Y Faceplate
Z Charged/Discharged Indicator
AA Open/Close Indicator Y
AB Push-to-Reset on Fault Trip Z
AB
Electrical Close Push Button AA
AC (BPFE)
AD Padlock Attachment
AE Key Interlock
14 0613CT0001
MasterPact™ Circuit Breakers Class 0613
B Padlock Provision
C Key Interlock
F Rejection Feature N
H Lifting Tab
L
Q
I Cradle Back Mold
K
R
Position Indicating Contact
J
Terminal Block J S
Overcurrent Trip Switch Terminal
K
Block I
M Tool Shield
Position Indicating Contact
N
Terminal Block H
Accessory Control Terminal
O
Block G
D
T Shutter
X Position Indicator
0613CT0001 15
Class 0613 MasterPact™ Circuit Breakers
A Terminal Cover
G Position Indicator
B
H Racking Handle Storage Space
Racking Handle
16 0613CT0001
MasterPact™ Circuit Breakers Class 0613
D
E
F
G
H
L
M
A
K
NT Cradle
N
J
O
I P
B Lifting Handle
C Terminal Cover
D Padlock Provision
E Position Indicator
Racking Handle Insertion
F Opening L
M
G Stop Release Button
L Accessory Cover
N :Push-to-close” Button
O “Push-to-open” Button
P Faceplate
0613CT0001 17
Class 0613 MasterPact™ Circuit Breakers
Ratings
Table 1 - Ratings for ANSI C37 Certified MasterPact NW Circuit Breakers 800–2000 A
Built In Instantaneous
Override —3 —3 —3 190 805 55 — — 190 80 55
(Peak kA ±10%)
Close and
Latch
Ratings Vac 50/60 Hz 90 150 90 90 55 50 150 90 90 55 50
(Peak kA)
Closing Time 70 ms
Table 2 - Ratings for ANSI C37 Certified MasterPact NW Circuit Breakers 3200–6000 A
Close and
Latch
Ratings Vac 50/60 Hz 150 90 90 90 170 170 90
(Peak kA)
1. Interrupting ratings (kAIR) at 50 Hz: 200 kA (254 Vac), 150 kA (508 Vac), 100 kA (635 Vac).
2. The interrupting ratings L1 and L1F are available only in 3P, drawout construction.
3. 55 kA for 800 A circuit breaker frame with 100 A or 250 A sensor.
4. 4000 A standard width circuit breaker is not available in L1 interrupting rating code or drawout construction.
5. ArcBlok circuit breakers are available only to 5000 A.
18 0613CT0001
MasterPact™ Circuit Breakers Class 0613
Table 2 - Ratings for ANSI C37 Certified MasterPact NW Circuit Breakers 3200–6000 A (Continued)
Closing Time
2000–4000 A
Sensor Rating 1600–4000 A 2500–5000 A
3000–6000 A
Endurance Mechanical 10,000 5000 5000
Rating (C/O
Cycles)
(with no
mainte- Electrical 1000 1000 1000
nance)
254 Vac 65 65 65 65 85 85
Breaking Capacity with External
Relay (kA), 50/60 Hz 508 Vac 65 65 65 65 85 85
635 Vac 65 65 65 65 85 85
Short-Time Withstand Current (kA) Vac
50/60 Hz, 0.5 s 65 65 65 65 85 85
254 Vac 100 200 100 200 100 200 100 200 100 200 100 200
Breaking Capacity
with External Relay 508 Vac 100 200 100 200 100 200 100 200 100 200 100 200
(kA), 50/60 Hz
635 Vac 85 130 85 130 85 130 85 130 85 130 85 130
Short-Time Withstand Current (kA)
50/60 Hz, 1.5 s 85 30 85 30 85 30 85 100 85 100 85 100
240 Vac 50/60 Hz 65 100 200 200 100 200 100 200
Interrupting
Current (kAIR) 480 Vac 50/60 Hz 65 100 150 150 100 150 100 150
600 Vac 50/60 Hz 50 85 100 100 85 100 85 100
Short-Time
Withstand Current Vac 50/60 Hz, 0.5 s 429 659 30910 22 65 65 85 100
(kA)
6. 4000 A standard width circuit breaker is not available in L1 interrupting rating code or drawout construction.
7. ArcBlok circuit breakers are available only to 5000 A.
8. 4000 A standard width automatic switch is not available in HC withstand rating code or drawout construction.
9. 24 kA for 800 A circuit breaker frame with 100 A or 250 A sensor.
10. 65 kA for 2000 A.
11. 55 kA for 800 A circuit breaker frame with 100 A or 250 A sensor.
12. 150 kA for 200 A sensor.
0613CT0001 19
Class 0613 MasterPact™ Circuit Breakers
Closing Time 70 ms
2000–4000 A /
Sensor Rating 100–250 A / 400–800 A / 600–1200 A / 800– 1200–2500 A /
2500–5000 A /
1600 A / 1000–2000 A 1600–3000 A
3000–6000 A
Endurance Rating Mechanical 12,50014 12,50014 12,50014 12,50014 10,000 10,000 5000 5000
(C/O Cycles) (with
no maintenance) Electrical 280014 280014 280014 280014 1000 1000 1000 1000
Frame Rating 800 A 1200 A 1600 A 2000 A 2500 A 3000 A 4000 A 5000 A 6000 A
Withstand
Rating Code HF HB HF HB HF HB HF HB HF HB HF HB HF HB HF HB HF HB
Table 7 - Ratings for IEC 60947-2 Rated MasterPact NW Circuit Breakers 800–2000 A
220/415
42 65 100 150 — 42 65 100 150 150 —
Vac
Ultimate 440 Vac 42 65 100 150 — 42 65 100 150 150 —
Breaking
Icu
Capacity (kA) 525 Vac 42 65 85 130 — 42 65 85 130 130 —
50/60 Hz
690 Vac 42 65 85 100 — 42 65 85 100 100 —
1150 Vac — — — — 50 — — — — — 50
Service
Breaking Ics %Icu 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100%
Capacity
Vac 50/60
Short-Time Hz, 1 s 42 65 85 30 50 42 65 85 65 30 50
Withstand Icw
Current (kA) Vac 50/60
Hz, 3 s 22 36 50 30 50 22 36 75 65 30 50
20 0613CT0001
MasterPact™ Circuit Breakers Class 0613
Table 7 - Ratings for IEC 60947-2 Rated MasterPact NW Circuit Breakers 800–2000 A (Continued)
Mechani-
12.5 10
cal
Endurance Rating
(with no maint.) C/O Electrical
10 10 10 3 — 8 8 8 3 3 —
Cycles x 1000 440 V
Electrical
— — — — 0.5 — — — — — 0.5
1150 V
Table 8 - Ratings for IEC 60947-2 Rated MasterPact NW Circuit Breakers 2500–6300 A
Service Breaking
Capacity Ics %Icu 100% 100% 100% 100% 100% 100%
Break Time ms 25 25
Closing Time ms < 70 < 80
Mechanical 10 5
Endurance Rating
(with no maint.) Electrical 440 V 5 5 1.25 — 1.5 1.5
C/O Cycles x 1000
Electrical 1150 V — — — 0.5 — —
4000B/
Frame Rating 800/1000/1250/1600 A 2000 A 2500/3200/4000 A 5000/6300
A
Withstand Rating Code17 NA HA HF HA10 HA HF HA10 HA HF HA10 HA
220/415 Vac,
88 105 187 — 105 187 — 121 189 — 187
50/60 Hz
Rated
Making 440 Vac,
Current Icm 88 105 187 — 105 187 — 121 189 — 187
50/60 Hz
(Peak kA)
500/690 Vac,
88 105 187 — 105 187 — 121 189 — 187
50/60 Hz
17. NA, HA, and HA10 are non-automatic switches; HF is an automatic switch.
0613CT0001 21
Class 0613 MasterPact™ Circuit Breakers
4000B/
Frame Rating 800/1000/1250/1600 A 2000 A 2500/3200/4000 A 5000/6300
A
1150 Vac,
— — — 105 — — 105 121 — 105 —
50/60 Hz
Short-
Time
Vac 50/60
Withstand Icw 42 50 85 50 50 85 50 50 85 50 85
Hz, 1 s
Current
(kA)
Ultimate
Breaking
Capacity
Maximum
(with Icu 42 50 85 50 50 85 50 50 85 50 85
Delay 350 ms
external
protection
relay) (kA)
254 Vac 60 Hz 42
Interrupting Current (kAIR) 508 Vac 60 Hz 42
635 Vac 60 Hz N/A
Short-Time Withstand Current (kA) ac 60 Hz, 0.5 s 42
25 to 30 ms
Breaking Time
(with no intentional time delay)
Mechanical 12,500
Endurance Rating (C/O Cycles) (with no maintenance)
Electrical 2800
240 Vac,
50 65 100 200 200 50 65 100 200 200 50 65 100 200
60 Hz
Interrupting 480 Vac,
Current (kAIR) 50 50 65 100 100 50 50 65 100 100 50 50 65 100
60 Hz
600 Vac,
35 50 N/A N/A N/A 35 50 N/A N/A N/A 35 50 N/A N/A
60 Hz
18. Fixed-mounted only. 1600 A UL489 drawout circuit breakers are not available.
22 0613CT0001
MasterPact™ Circuit Breakers Class 0613
Short-Time
Withstand Vac 60 Hz,
Current Rating 35 35 10 10 10 35 35 10 10 10 35 35 10 10
0.5 s
(kA)
Close and
Latch Ratings Vac 60 Hz 55 55 22 22 22 55 55 22 22 22 55 55 22 22
(Peak kA)
19. Fixed-mounted only. 1600 A UL489 drawout circuit breakers are not available.
20. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
0613CT0001 23
Class 0613 MasterPact™ Circuit Breakers
Service Breaking
Capacity (kA) Ics %Icu 100% 100% 100% 100% 100%
Short-Time
Withstand Current Icw Vac 50/60 Hz, 1 s 42 42 10 x In21 42 36
(kA)
Break Time ms 25 25 9 25 25
Closing Time ms 50 50 50 50 50
24 0613CT0001
MasterPact™ Circuit Breakers Class 0613
Correction Factors
Table 16 - Temperature Correction Factors
Table 17 - Altitude Correction Factors per ANSI C37.20.1 par. 7.1.4.1 (Table 10)
Shipping Weights
Table 18 - Shipping Weights for UL Listed/ANSI Certified MasterPact NW Circuit Breakers
0613CT0001 25
Class 0613 MasterPact™ Circuit Breakers
Table 19 - Shipping Weights for IEC 60947-2 Rated MasterPact NW Circuit Breakers
Table 21 - Shipping Weights for IEC 60947-2 Rated MasterPact NT Circuit Breakers
26 0613CT0001
Energy Management Class 0613
Energy Management
Energy Management Using the Enerlin'X System
Use the Enerlin’X communication system to connect a building to real savings in
three steps:
A. Measure
• Embedded and stand-alone metering and control
B. Connect
• Integrated communication interfaces
• Ready to connect to energy management platforms
C. Save
• Data-driven energy efficiency actions
• Real-time monitoring and control
• Access to energy and site information through on-line services
CLOUD
Measure
Use the Enerlin’X communication system to connect a building to real savings in
three steps:
A. Measure
• Embedded and stand-alone metering and control
B. Connect
• Integrated communication interfaces
• Ready to connect to energy management platforms
C. Save
• Data-driven energy efficiency actions
0613CT0001 27
Class 0613 Energy Management
CLOUD
Connect
Enerlin’X communication systems use reliable, simple-to-install-and-use displays,
and Ethernet and Modbus interfaces.
Information is safely transmitted through the most efficient networks:
• Modbus SL inside switchboards, between components,
• Ethernet, on cable or WiFi, inside the building and connecting switchboards
and computers,
• Ethernet or GPRS, for access to on-line services by Schneider Electric.
Energy experts, no matter where they are located, can now provide advise based
on the updated data of the building.
Save
On-Site Real-Time Monitoring and Control
28 0613CT0001
Energy Management Class 0613
The FDM128 touch screen provides real-time value checking and control, directly
on the front panel of the main switchboard.
On a PC display with common browser:
• shows monitoring web pages hosted into the local Ethernet interface,
• alarm events generate automatic email notifications,
• allows control (open, close, reset…) of various equipment.
The data is displayed graphically or recorded into files for optimizing the use of
energy in the building.
As an example, the data can help validate the change of temperature settings,
time scheduling in a Building Management System or other automated devices.
CLOUD
0613CT0001 29
Class 0613 Energy Management
Displays
FDM121
• One-to-one front display module
Power Meter
• See FDM121 Display, page 36 for more information.
FDM128
• One-to-eight front display module
• See FDM128 Display, page 40 for more information.
Communication
• MasterPact circuit breakers in a communication network
• IO application module
• IFE: Ethernet interface module
Operating • IFM: Modbus interface module
Assistance
Functions
Communication
See Indication Option via Programmable Contacts, page 58 for more information.
30 0613CT0001
Energy Management Class 0613
Display Function
FDM121 Display Unit (One to One)
FDM121 Display FDM121 Display FDM121 Display: FDM121 Display: FDM121 Display:
Navigation Current Voltage Power Consumption
I PQS
Main Menu V 4/7 E
I1 310 A I2 315 A
Quick view P 64 kW
402 V % 100 120 Ep 14397 kWh
U1
Metering Q 38 kVar
% % Eq 8325 kVarh
398 V % 100 120
Control I3 302 A IN 23 A U2 S 51 kVA
Es 13035 kVAh
Alarms 401 V % 100 120
U3
Services % %
OK ESC ESC
ESC ESC ESC
FDM128 Display FDM128 Display FDM128 Display: FDM128 Display: FDM128 Display:
Navigation Current Voltage Power Consumption
For all FDM, in addition to the information displayed on the MicroLogic trip unit
LCD, the FDM screen shows demand, power quality, and maximum/minimum
ammeter values along with histories and maintenance indicators.
0613CT0001 31
Class 0613 Energy Management
Measurement Function
Instantaneous RMS Measurements
The MicroLogic trip unit continuously displays the RMS value of the highest
Measurement current of the three phases and neutral (Imax). The navigation buttons can be
Function used to scroll through the main measurements.
In the event of a fault trip, the trip cause is displayed.
The MicroLogic A trip unit measures phase, neutral, and ground fault currents.
MicroLogic P/H trip units offer voltage, power, power factor, frequency, and cos φ
in addition to the measurements provided by MicroLogic A trip units.
Energy Metering
The MicroLogic P/H trip units also measures the energy consumed since the last
reset of the meter. The active energy meter can be reset using the MicroLogic trip
unit keypad, the FDM display unit, or the communication system.
Power Quality
The MicroLogic H trip unit calculates power quality indicators taking into account
the presence of harmonics up to the fifteenth harmonic, including the total
harmonic distortion (THD) of current and voltage.
32 0613CT0001
Energy Management Class 0613
Display
MicroLogic A/P/H Integrated Power Meter Functions Type
MicroLogic FDM
LCD Display
Measurements
Instantaneous rms measurements
Average of phase-to-phase
Vavg = (VAB + VBC + VCA) / 3 P/H — X
voltages
Voltages (V)
Average of phase-to-neutral
Vavg = (VAN + VBN + VCN) / 3 P/H — X
voltages
P, total P/H X X
Active (kW)
P, per phase P/H X X
Q, total P/H X X
Reactive (kVAR)
Q, per phase P/H X X
S, total P/H X X
Power Apparent (kVA)
S, per phase P/H X X
0613CT0001 33
Class 0613 Energy Management
Table 22 - MicroLogic A/P/H Trip Units Integrated Power Meter Functions (Continued)
Display
MicroLogic A/P/H Integrated Power Meter Functions Type
MicroLogic FDM
LCD Display
Power Quality
Histories
• Trip indications in clear text in a number of user-selectable languages
• Time-stamping: date and time of trip.
Maintenance Indicators
MicroLogic trip units have indicators for, among other items, the number of
operating cycles, contact wear P/H, load profile and operating times (operating
hours counter) of the MasterPact circuit breaker.
It is possible to assign an alarm to the operating cycle counter to plan
maintenance.
The various indicators can be used together with the trip histories to analyze the
level of stresses to which device has been subjected.
Contact Wear
Each time a MasterPact circuit breaker opens, the MicroLogic P/H trip unit
measures the interrupted current and increments the contact-wear indicator as a
function of the interrupted current, according to test results stored in memory.
Breaking under normal load conditions results in a very slight increment. The
indicator value may be read on the FDM display.
It provides an estimation of contact wear calculated on the basis of the cumulative
forces affecting the circuit breaker. When the indicator reaches 100%, it is advised
to visually inspect the contacts per the instructions in the circuit breaker user
guide.
34 0613CT0001
Energy Management Class 0613
Display
MicroLogic A/P/H Operating Assistance Functions Type
FDM
MicroLogic LCD
Display
Operating Assistance
Trip History
Maintenance Indicators
Mechanical cycles Assignable to an alarm A/P/H — X
0613CT0001 35
Class 0613 Energy Management
FDM121 Display
MicroLogic trip unit measurement capabilities come into full play with the FDM121
display. It connects to the COM option (BCM ULP) with a circuit breaker ULP cord
and displays the MicroLogic trip unit information. The result is a true integrated
unit combining a circuit breaker and a power meter. Additional operating
assistance functions can also be displayed.
An FDM121 display unit can be connected to ULP communication devices using a
prefabricated cord to display all measurements, alarms, histories and event
tables, maintenance indicators, and management of installed devices on a screen.
The FMD121 display unit requires a 24 Vdc power supply.
The FDM121 is a display that can be integrated with the PowerPact H/J/L/P/R or
MasterPact NT circuit breaker systems. It uses the sensors and processing
capacity of the MicroLogic trip unit. It is easy to use and requires no special
software or settings. It is immediately operational when connected to the circuit
breaker by a ULP cord.
It also provides monitoring and control with the use of the IO application module,
the motor mechanism module, or the circuit breaker communication module (BCM
ULP).
The FDM121 has a large display, but requires very little depth. The anti-glare
graphic screen is backlit for very easy reading even under poor ambient lighting
and at sharp angles.
36 0613CT0001
Energy Management Class 0613
When the circuit breaker is equipped with the Breaker Communications Module
(BCM ULP), the FDM121 display can also be used to view circuit breaker status
conditions:
• O/F: ON/OFF
• SD: trip indication
• SDE: fault-trip indication (overload, short-circuit, or ground fault).
When the circuit breaker system is equipped with the IO application module, the
FDM121 can monitor and control:
• cradle management
• circuit breaker operation
• light and load control
• custom applications.
When the circuit breaker is equipped with the COM option (BCM ULP) (including
connection to shunt close [XF] and shunt trip [MX1] communication voltage
releases), the FDM121 display can also be used to control (open/close) the circuit
breaker.
Two operating mode are available:
• local mode: open/close commands are enabled from the FDM121 while
disabled from the communication network;
• remote mode: open/close commands are disabled from the FDM121 while
enabled from the communication network.
0613CT0001 37
Class 0613 Energy Management
Main Characteristics
• A 3.78 x 3.78 x 1.18 in. (96 x 96 x 30 mm) screen requiring 0.39 in. (10 mm)
behind the door (or 0.79 in. [20 mm] when the 24 V power supply connector is
used).
• White backlighting.
• Wide viewing angle: vertical ±60°, horizontal ±30°.
• High resolution: excellent reading of graphic symbols.
• Alarm LED: flashing orange for alarm pick-up, steady orange after operator
reset if the alarm condition persists.
• Operating temperature range: +14°F (-10°C) to +131°F (+55°C).
• CE / UL / CSA marking.
• 24 Vdc power supply, with tolerances 24 V -20% (19.2 V) to 24 V +10%
(26.4 V).
When the FDM121 is connected to the communication network, the 24 Vdc can be
supplied by the communication system wiring system. Consumption is 40 mA.
Mounting
The FDM121 is easily installed in a switchboard.
• Standard door cut-out is 3.6 x 3.6 in. (92 x 92 mm).
• Attached using clips.
To avoid a cut-out in the door, an accessory is available for surface mounting by
drilling only two 0.87 in. (22 mm) diameter holes.
Connection
The FDM121 is equipped with a 24 Vdc terminal block:
• A plug-in type terminal block with two wire inputs per point for easy daisy-
chaining.
• A power supply range of 24 Vdc -20% (19.2 V) to 24 Vdc +10% (26.4 V).
A 24 Vdc type auxiliary power supply must be connected to a single point on
the ULP system. The FDM121 display has a two-point screw connector on
the rear panel of the module for this purpose. The ULP module to which the
auxiliary power supply is connected distributes the supply via the ULP cable
to all the ULP modules connected to the system and therefore also to
MicroLogic trip unit. See Communication Components and FDM121
Connections, page 40 later in this section.
• Two RJ45 jacks.
The MicroLogic trip unit connects to the internal communication terminal block on
the MasterPact circuit breaker with the circuit breaker ULP cord. Connection to
one of the RJ45 connectors on the FDM121 automatically establishes
communication between the MicroLogic trip unit and the FDM121 and supplies
power to the MicroLogic trip unit measurement functions.
When the second connector is not used, it must be fitted with a line terminator.
38 0613CT0001
Energy Management Class 0613
Navigation
Five buttons are used for intuitive and fast navigation.
The “Context” button may be used to select the type of display (digital, bargraph,
analogue).
The user can select the display language (Chinese, English, French, German,
Italian, Portuguese, Spanish, etc.).
I1 310 A
I
I2 315 A
1 Escape
% % 2 Down
I3 302 A IN 23 A
3 OK
% %
ESC
4 Up
5 Context
6 Alarm LED
1 2 3 4 5 6
Product Metering:
Identification Submenu Metering: Meter Services
Screens
Main Menu
When powered up, the FDM121 screen automatically displays the ON/OFF status
of the device.
When not in use, the screen is not backlit. Backlighting can be activated by
pressing one of the buttons. It goes off after three minutes.
0613CT0001 39
Class 0613 Energy Management
Modbus-SL Ethernet
External power supply External power supply
24 Vdc
- +
A 24 Vdc
- +
B
D0 = A’ / Rx-, A / Tx-
D1 = B’ / Rx+, B / Tx+
24VDC
ETH1 ETH2
IFM D IFE D
OR
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
LV434195 LV434196 LV434197 Customer Terminal Block Customer Terminal Block
FDM128 Display
The MicroLogic trip unit measurement capabilities are fully utilized with the
FDM128 display. The FDM128 display connects to Ethernet communication using
the RJ45 port and displays MicroLogic trip unit information. The result is an
integrated unit combining a circuit breaker with a power meter. Additional
operating assistance functions can also be displayed.
The FDM128 display unit can be connected to a MicroLogic COM option (BCM
ULP through an IFE). It uses the sensors and processing capacity of the
MicroLogic trip unit and requires no special software or settings. The FDM128 is a
large display, but requires very little depth. The anti-glare graphic screen is backlit
for easy reading even under poor ambient lighting and at sharp angles.
The FDM128 display is designed to manage up to eight devices (PowerPact H/J/
L/P/R or MasterPact NW/NT circuit breakers).
40 0613CT0001
Energy Management Class 0613
Status Indications
When the circuit breaker is equipped with the COM option (BCM ULP) (including
its set of sensors) the FDM128 display can also be used to view circuit breaker
status conditions:
• O/F: ON/OFF
• SDE: Fault-trip indication (overload, short-circuit, ground fault)
• PF: ready to close
• CH: charged (spring loaded)
• CE, CD, CT cradle management with IO application module
Remote Control
When the circuit breaker is equipped with the COM option (BCM ULP) (including
connection to shunt close [XF] and shunt trip [MX1] communication voltage
releases), the FDM128 display can also be used to operate (open/close) the
circuit breaker.
Two operating mode are available:
• Local mode: open/close commands are enabled from the FDM128 while
disabled from the communication network.
• Remote mode: open/close commands are disabled from the FDM128 while
enabled from the communication network.
Main Characteristics
• 4.54 x 3.40 in. (115.2 x 86.4 mm) with 5.7 in. (145 mm) QVGA display 320 x
240 pixels.
• Color TFT LCD, with LED backlight.
• Wide viewing angle: vertical ±80°, horizontal ±70°.
• High resolution: excellent reading of graphic symbols.
• Operating temperature range: +14°F (-10°C) to +131°F (+55°C).
• CE / UL / CSA marking.
• 24 Vdc power supply, -10%/+20% (limit 20.4 - 28.8 Vdc).
• Consumption 6.8 W.
Mounting
The FDM128 is easily installed in a switchboard.
• Standard door hole Ø 0.87 in. (22 mm).
• The FDM128 degree of protection is IP65 at the touch screen cover. IP54 is
maintained after installation by using the supplied gasket.
0613CT0001 41
Class 0613 Energy Management
Connection
The FDM128 is equipped with:
• a 24 Vdc terminal block:
power supply range of 24 Vdc (limit 20.4 - 28.8 Vdc).
The FDM128 display unit has a 2-point screw connector on the rear panel of
the module for this purpose.
• One RJ45 Ethernet jacks.
The MicroLogic trip unit connects to the internal communication terminal block on
the MasterPact circuit breakers through the circuit breaker ULP cord and Ethernet
connection through the IFE.
Navigation
• A touch screen is used for intuitive and fast navigation.
• The user can select the display language (Chinese, English, French, German,
Italian, Portuguese, Spanish, etc.).
Maintenance
Close command xxx Control
Es 13 815 kVAh Maintenance
80 to 89%
Maintenance 90 to 100%
Screens
Main Menu
42 0613CT0001
Energy Management Class 0613
B
4.3 ft 9.8 ft
(1.3 m) (3 m)
0.98 ft
(0.35 m) DD
A FDM128
B Ethernet Network
C Circuit Breaker ULP Cord
D UFE
E ULP Termination
0613CT0001 43
Class 0613 Energy Management
ULP
ULP
PowerPact
Internet
(cloud)
Energy
Server with
Modbus Ethernet
A Com’X 200 Ethernet 6 2 —
Master Cable
Gateway®
Function
Ethernet
LCD Color
B FDM128 — Ethernet — — —
Touch
Screen
LCD Display
C FDM121 for Circuit ULP — — — —
Breaker
44 0613CT0001
Energy Management Class 0613
D
Ethernet
Interface for
IFE Interface ULP Ethernet — — —
Circuit
Breakers
Modbus
Interface for Modbus
E IFM ULP — — —
Circuit Slave
Breakers
Input/Output
Application
F IO Module for ULP ULP 6 1 1
Circuit
Breakers
0613CT0001 45
Class 0613 MicroLogic™ Electronic Trip Systems
Basic Trip
2 3 5 —
Unit
A Trip Unit 2.0A 3.0A 5.0A 6.0A
All MasterPact circuit breakers are equipped with the MicroLogic trip system to
protect power circuits and loads. MicroLogic trip systems use a set of current
transformers (called CTs or sensors) to sense current, a trip unit to evaluate the
current, and a tripping solenoid to trip the circuit breaker. Adjustable rotary
switches on the trip unit allow the user to set the proper overcurrent or equipment
ground-fault current protection required in the electrical system. If current exceeds
a set value for longer than its set time delay, the trip system opens the circuit
breaker. Alarms may be programmed for remote indications. Measurements of
current, voltage, frequency, power, and power quality optimize continuity of
service and energy management. MicroLogic trip units can be changed on-site.
Integration of protection functions in the Application Specific Integrated Circuit
(ASIC) electronic component used in all MicroLogic trip units guarantees a high
degree of reliability and immunity to conducted or radiated disturbances. On
MicroLogic P and H trip units, advanced functions are managed by an
independent microprocessor.
MasterPact circuit breakers are shipped with the long-time pickup switch set at 1.0
and all other trip unit adjustments set at their lowest settings. Actual settings
required for a specific application must be determined by a qualified consultant or
plant engineer. A coordination study is recommended to provide coordination
between all circuit breakers in the distribution system.
Thermal Imaging
The thermal imaging function protects the cables or bus bars from overheating in
case of low amplitude repetitive faults. Such overheating can be due to repetitive
motor starting, fluctuating load, intermittent ground faults, or subsequent closing
after a fault.
Traditional electronic protection does not protect against repetitive faults because
the duration of each overload above the pickup setting is too short to achieve
effective tripping. Nevertheless, each overload involves a temperature rise in the
installation, the cumulative effect of which could lead to overheating of the system.
The thermal imaging function remembers and integrates the thermal heating
caused by each pickup setting overrun. Before tripping, the integrated heating
value will reduce the associated time delay and, therefore, the reaction of the trip
unit will be closer to the real heating of the power network system.
After tripping, the function will also reduce the time delay when closing the circuit
breaker on an overload.
46 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
1600–6300 A 500 A
0613CT0001 47
Class 0613 MicroLogic™ Electronic Trip Systems
Power (P) and Harmonic (H) Trip Unit Without 24 Vdc Power Supply at F1 and F2
The P and H trip units were designed to be used with the external 24 Vdc power
supply. The large LCD display requires too much current to be powered by current
flow through the circuit breaker. The P and H trip units do have a voltage power
supply which will power the trip unit with 100 Vac or more between two phases or
phase to neutral. The standard configuration for the voltage probes inside the
circuit breaker is at the bottom connections. If the circuit breaker was open in a top
fed application, there would be no voltage at the bottom of the circuit breaker and
the trip unit would not be powered.
• Provides fault protection for LSIG functions.
• Provides LED trip indication (powered by an onboard battery).
NOTE: Ground-fault push-to-trip button works for testing ground fault if the trip
unit is powered by the voltage power supply. The ground-fault push-to-trip is
also functional if a hand-held test kit or full-function test kit is powering the trip
unit.
Power (P) and Harmonic (H) Trip Unit With 24 Vdc Power Supply at F1 and F2
• Provides all of the above.
• LCD display and backlight are functional.
• Ground-fault push-to-trip button works for testing ground fault.
• All metering, monitoring, and history logs are functional.
• Communications from trip unit to M2C and M6C programmable contact
modules are powered by a 24 Vdc supply at F1 and F2. M6C also requires a
24 Vdc external power supply.
• Modbus communications—also requires a separate 24 Vdc power supply for
the circuit breaker communications module.
NOTE: Ground-fault push-to-trip button will also be functional if hand-held test
kit or full-function test kit is powering the trip unit.
48 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
MicroLogic 3.0 and 5.0 MicroLogic 3.0A, 5.0A MicroLogic 5.0P and MicroLogic 5.0H and
Basic Trip Units and 6.0A Trip Units 6.0P Trip Units 6.0H Trip Units
0613CT0001 49
Class 0613 MicroLogic™ Electronic Trip Systems
UL Listed X X X X X X X X X
Thermal Imaging X X X X X X X X X X X
Digital Ammeter X X X X X X X X
Zone-Selective Interlocking32 X X X X X X X
Communications O O O O X X X X
LCD Dot Matrix Display X X X X
Neutral Protection30 X X X X
Contact Wear Indication X X X X
Incremental Fine Tuning of
Settings X X X X
Waveform Capture X X
50 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Protection Settings
Protection thresholds and delays are set using the rotary switches.
A full-range of long-time settings are available via the field-installable adjustable
rating plugs.
• Overload protection
— True RMS long-time protection
— Thermal imaging: active thermal imaging before and after tripping
• Short-circuit protection
— Short-time RMS
— Selection of I2t type (ON or OFF) for short-time delay
• Instantaneous protection
• Neutral protection on four-pole circuit breakers
3
2 4 Instantaneous pickup
6 Test connector
0613CT0001 51
Class 0613 MicroLogic™ Electronic Trip Systems
52 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
MicroLogic 2.0A, 3.0A, 5.0A and 6.0A Trip Units with Ammeter
MicroLogic A trip units protect power circuits and provide current measurements,
overload protection, and short-circuit protection. In addition, the 6.0A trip units
also provide ground-fault protection for equipment.
Protection Settings
Protection thresholds and delays are set using the rotary switches. The selected
values are momentarily displayed in amperes and in seconds. A full-range of long-
time settings are available via the field-installable rating plug.
• Overload protection (true RMS long-time protection)
• Thermal imaging (active thermal imaging before and after tripping)
• Short-circuit protection
— Short-time RMS
— I2t ON or OFF for short-time delay
• Instantaneous protection
• Ground-fault protection for equipment
— Residual ground-fault protection for equipment
— Source ground-return ground-fault protection for equipment
— Modified differential ground-fault protection (MDGF) for equipment
• Neutral protection on four-pole circuit breakers
• ZSI: Zone-selective interlocking
— A ZSI terminal block may be used to interconnect a number of trip units to
provide total discrimination for short-time and equipment ground-fault
protection, without delay for tripping
— Not available for 3.0 A trip unit
— Not available for 2.0 A trip unit if installed as upstream device
2 3 Digital display
10 Instantaneous pickup
11 Electronic push-to-trip
6
8 7 12 Ground-fault pickup and tripping delay
13 Test connector
9 10
11
12
13
0613CT0001 53
Class 0613 MicroLogic™ Electronic Trip Systems
Ammeter Measurements
MicroLogic A trip units measure the true RMS value of currents. They provide
continuous current measurement from 0.2 to 20 x In with an accuracy of 1.5%
(including sensors). No auxiliary source is needed where I > 0.2 x In. The optional
external power supply (24 Vdc) makes it possible to display currents where I < 0.2
x In and to store values of the interrupted current. A digital LCD screen
continuously displays the most heavily loaded phase (Imax) or displays the Ia, Ib,
Ic, Ig, and (on four-pole circuit breakers only) In stored current and setting values
by successively pressing the navigation button.
Communication Network
Four wire Modbus, RTU, RS485 or two wire Modbus, TRU, RS485 plus ULP. See
Additional Wiring Information for MasterPact NW NT Circuit Breakers, page 120.
In conjunction with an optional communication network, the trip unit transmits the
following parameters:
• Setting values.
• All ammeter measurements.
• Tripping causes.
NOTE: Current-based protection functions require no auxiliary power source.
When an external power supply is added, the value of the interrupted current
is stored by the trip unit. The reset button resets alarms and stored interrupted
current indications.
t
Ir
tr
Ii
0 I
Current Setting 2.0A: 0.4 0.5 0.6 0.7 0.8 0.9 0.95 0.98 1
(A) Tripping 3.0A: 0.4 0.45 0.5 0.6 0.63 0.7 0.8 0.9 1
Ir = ln x...
Between 1.05
and 1.20 x Ir Other ranges are available by changing rating plug
Long-Time
tr at 1.5 x Ir 12.5 25 50 100 200 300 400 500 600
Protection Time Delay (s)
Accuracy: 0 to – tr at 6 x Ir 0.5 1 2 4 8 12 16 20 24
20%
tr at 7.2 x Ir 0.34 0.69 1.38 2.7 5.5 8.3 11 13.8 16.6
Thermal Imaging 20 minutes before or after tripping
Current Setting
Short-Time (A) Accuracy: Isd = Ir x... 2.0A: 1.5 2 2.5 3 4 5 6 8 10
Protection ±10% No delay
Current Setting
Instantaneous
(A) Accuracy: Ii = In x... 3.0A: 1.5 2 3 4 5 6 8 10 12
Protection
±10%
54 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Current Setting IEC: 0.4 0.5 0.6 0.7 0.8 0.9 0.95 0.98 1
(A) Tripping UL/ANSI: 0.4 0.45 0.5 0.6 0.63 0.7 0.8 0.9 1
Ir = ln x...
Between 1.05
and 1.20 x Ir Other ranges are available by changing rating plug
Long-Time
tr at 1.5 x Ir 12.5 25 50 100 200 300 400 500 600
Protection Time Delay (s)
Accuracy: 0 to – tr at 6 x Ir 0.5 1 2 4 8 12 16 20 24
20%
tr at 7.2 x Ir 0.34 0.69 1.38 2.7 5.5 8.3 11 13.8 16.6
Thermal Imaging 20 minutes before or after tripping
Current Setting
(A) Accuracy: lsd = Ir x... 1.5 2 2.5 3 4 5 6 8 10
±10%
Ig = ln x... A B C D E F G H J
Ground-Fault Pickup (A) ln ≤ 400 A 0.3 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Accuracy: ±10%
400 A < ln ≤ 1200 A 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
ln > 1200 A 500 640 720 800 880 960 1040 1120 1200
I2t OFF 0 0.1 0.2 0.3 0.4
Settings
I2t ON 0.1 0.2 0.3 0.4
Time Delay
(s) at 1 x In Minimum Trip Time (ms) 20 80 140 230 350
tg
Maximum Trip Time (ms) 80 140 200 320 500
0613CT0001 55
Class 0613 MicroLogic™ Electronic Trip Systems
4 Measurement display
5 Maintenance indicators
6 Protection settings
7 Navigation buttons
12 Instantaneous pickup
14 Electronic push-to-trip
16 Test connector
56 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Maintenance Record
The maintenance record can be consulted using the full-function test kit or
remotely via the communication network. It can be used as an aid in
troubleshooting and to assist scheduling for device maintenance operations.
Recorded indications include:
• Highest current measured
• Operation counter (both cumulative total and total since last reset)
• Number of test kit connections
• Number of trips in operating mode
• Contact wear (MasterPact NW only)
0613CT0001 57
Class 0613 MicroLogic™ Electronic Trip Systems
Current Ir = ln x... IEC: 0.4 0.5 0.6 0.7 0.8 0.9 0.95 0.98 1
Setting (A) UL/
Tripping Ir = ln x... 0.4 0.45 0.5 0.6 0.63 0.7 0.8 0.9 1
ANSI:
Between 1.05
and 1.20 x Ir Other ranges are available by changing rating plug
Current
Setting (A)
lsd = Ir x... 1.5 2 2.5 3 4 5 6 8 10
Accuracy:
±10%
I2t
0 0.1 0.2 0.3 0.4
Settings OFF
Current
Instantaneous Setting (A)
Ii = In x... 2 3 4 6 8 10 12 15 off
Protection Accuracy:
±10%
58 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Ig = ln x... A B C D E F G H J
Maximum trip
time (ms) 80 140 200 320 500
Table 32 - Settings for Alarms for Other Protection Functions for MicroLogic 5.0P and 6.0P Trip Units
Voltage Minimum Voltage Vmin 100 to 725 V (phase total) 0.25 to 0.5 s
Table 33 - Load-Shedding Settings for Current and Power Metering for MicroLogic 5.0P and 6.0P Trip
Units
Pick-Up Drop-Out
Current I 0.5 to 1.0 x Ir per phase 20% to 80% x tr 0.3 to 1.0 x Ir per phase 10 to 600 s
0613CT0001 59
Class 0613 MicroLogic™ Electronic Trip Systems
Trip History
Trip Trip
• Type of fault
history 05 / 20 / 00
• Date and time of fault 10:23:42 am
Ii Ii 7200 A
• Interrupted current 05 / 20 / 00
Ia = 7800 A
• Contact wear Ii Ib = 7800 A
04 / 28 / 00 Ic = 7800 A
Vmin In = 7800 A
04 / 28 / 00
Alarm History
Alarm Trip
• Type of alarm
history 05 / 20 / 00
• Date and time of the alarm Al 996A
Al
• Values measured at the time of 05 / 20 / 00
the alarm Al
04 / 28 / 00
Al
02 / 28 / 00
Metering
The MicroLogic P trip unit calculates in real time all electrical values V, A, W, VAR,
VA, Wh, VARh, VAh, Hz, power factor, and crest factor. The MicroLogic P trip unit
also calculates demand current and demand power over an adjustable time
period.
60 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
VIMBALANCE % VRMS
Demand Metering: The demand is calculated over a fixed or sliding time window
that can be programmed from five to sixty minutes. Depending on the contract
signed with the power supplier, specific programming makes it possible to avoid or
minimize the cost of overrunning the subscribed power. Maximum demand values
are systematically stored and time stamped.
Communication Network
Four wire Modbus, RTU, RS485—The communication network may be used to:
• Remotely read parameters for the protection functions.
• Transmit all the measurements and calculated values.
• Signal the causes of tripping and alarms.
• Consult the history files and the maintenance indicator record.
In addition, an event log of the last 100 events and a maintenance record, which is
stored in the trip unit memory but not available locally, may be accessed via the
communication network.
The Modbus communication system is compatible with Powerlogic™ System
Manager™ (SMS) software.
Event Log
The event log may be accessed by a remote computer via the communication
network. All events are time stamped and include:
• Trips
• Beginning and end of alarms
• Modifications to settings and parameters
• Loss of time
• Overrun of wear indicators
• Test kit connections
• Counter resets
• System faults (thermal self-protection, major fault and minor fault alarms)
0613CT0001 61
Class 0613 MicroLogic™ Electronic Trip Systems
MicroLogic 6.0H
Trip Unit
Metering
The MicroLogic H trip unit offers all the measurements carried out by the
MicroLogic P trip unit, with the addition of phase-by-phase measurements of
power and energy as well as calculation of:
• Current and voltage total harmonic distortion (THD, thd).
• Current, voltage and power fundamentals (50/60 Hz).
• Harmonic components (amplitude and phase) up to the 31st current and
voltage harmonic.
Real-Time Metering: The value displayed on the screen is refreshed every
second. The table below shows what is measured in real-time metering.
VIMBALANCE % VRMS
62 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
50/60 Hz
Fundamentals V, I, P, Q, and S
component
Power
Quality THD % V/I
Indicators
Amplitude to
V and I harmonics 1, 2, 3, 4...50
phase
Demand Metering: Similar to the MicroLogic P trip unit, demand values are
calculated over a fixed or sliding time window that can be set from five to 60
minutes.
Waveform Capture
MicroLogic H trip units can capture and store current and voltage waveforms using
digital sampling techniques similar to those used in oscilloscopes. Using the
information available in the captured waveform, it is possible to determine the
level of harmonics as well as the direction and amplitude of the flow of harmonic
power.
Users of MicroLogic H trip units can record manually via the keypad the following
waveforms:
• The four currents: Ia, Ib, Ic, and IN
• The three phase-to-phase voltages: Vab, Vbc, and Vca
Waveforms may be displayed on the graphic screen of MicroLogic H trip units or
communicated over a networked system. The recording takes place over one
cycle with a measurement range of 0 to 1.5 IN for current and 0 to 690 volts for
voltage. The resolution is sixty-four points per cycle.
Event Logs
Each event is recorded with:
• The date, time, and name of the event.
• The event characteristics.
0613CT0001 63
Class 0613 MicroLogic™ Electronic Trip Systems
long time
Long-Time
Delay
The long-time delay switch sets the length of time that the circuit breaker will carry
a sustained overload before tripping. Delay bands are labeled in seconds of
Ir tr alarm
.8 (s) 4
8
.7 .9 12
.6 .95 2 16
.5 .98 1 20
24
overcurrent at six times the ampere rating. For maximum coordination, there are
.4 1 .5
x In
short time
@ 6 Ir
instantaneous
Alarm
Isd
3
4
5
tsd
(s) .4 .4 .3
Ii
6 8 10 Indicator
2.5
2
1.5
x Ir
10
6
8
.3
.2
on
.1
I2t
0
.2
.1
off
4
3
2
x In
12
15
off
eight delay bands. Long-time delay is an “inverse time” characteristic in that the
Ig
C
D
setting
E
F
G
tg
(s)
.3
delay
.4 .4 .3
.2
test
delay time decreases as the current increases.
B H .2 .1
A J .1 0
on I2t off
ground fault
The trip unit includes an alarm indicator that will be lit continuously when the
current is above 100% of the pickup setting.
64 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
The ground-fault delay switch sets the length of time the circuit breaker will carry
.7 .9 12
.6
.5
.95 2
.98 1
16
20
Ground-
.4
x In
1 .5 24
@ 6 Ir Fault
Isd
2.5
3
short time
4
5
tsd
(s)
.3
.4 .4 .3
.2
Ii
instantaneous
6 8 10
Pickup ground-fault current which exceeds the ground-fault pickup level before tripping.
6 4 12
2
1.5
x Ir
10
8 .2
on
.1
I2 t
0
.1
off
3
2
x In
15
off Ground- The delay (based on the sensor plug amperage (In) can be adjusted to four
setting delay Fault
positions of I2t ramp operation (I2t ON) or five positions of fixed time delays (I2t
test
Ig tg
C
D
E
F
G
(s)
.3
.4 .4 .3
.2
Delay
.2 .1
OFF). I2t ON delay is an “inverse time” characteristic in that the delay time
B H
A J .1 0
on I2t off
ground fault
0613CT0001 65
Class 0613 MicroLogic™ Electronic Trip Systems
H
H
H
I I
K K K
A FDM128 display for 8 LV devices G PowerPact H-, J-, or L-frame circuit breaker
B IFE Ethernet interface for LV circuit breaker and gateway H ULP line terminator
66 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Spring charged X A P H
Ready to close X A P H
Fault-trip SDE X A P H
Controls
MX1 shunt trip X A P H
XF shunt close X A P H
Measurements
Instantaneous measurement information — A P H
Averaged measurement information — — H
Power quality — — — H
P: MicroLogic trip unit
“Power” Operating Assistance
0613CT0001 67
Class 0613 MicroLogic™ Electronic Trip Systems
Modbus Principle
The Modbus RS 485 (RTU protocol) system is an open bus on which
communicating Modbus devices (MasterPact NW with Modbus COM, Power
Meter PM700, PM800, PowerPact P/Rframe, etc.) are installed. All types of PLCs
and microcomputers may be connected to the bus.
Addresses
The Modbus communication parameters (address, baud rate, parity) are entered
using the keypad on the MicroLogic A, P, or H trip unit. For a switch, it is
necessary to use the Electrical Asset Manager or RSU (Remote Setting Utility)
MicroLogic utility.
Number of Devices
The maximum number of devices that may be connected to the Modbus bus
depends on the type of device (ComPact circuit breaker with Modbus COM,
PM700, PM800, MasterPact circuit breaker, etc.), the baud rate (19200 is
recommended), the volume of data exchanged and the desired response time.
The RS 485 physical layer offers up to thirty-two connection points on the bus
(one master, thirty-one slaves).
Length of Bus
The maximum recommended length for the Modbus bus is 3940 feet (1200
meters).
Bus Power Source
A 24 Vdc power supply is required (less than 20% ripple, insulation class II).
Ethernet Principle
Ethernet is a data link and physical layer protocol defined by IEEE 802 10 and 100
Mbps specifications that connects computer or other Ethernet devices. Ethernet is
an asynchronous Carrier Sense Multiple Access with Collision detection (referred
as CSMA/CD) protocol. Carrier Sense means that the hosts can detect whether
the medium (coaxial cable) is idle or busy.
Multiple Access means that multiple hosts can be connected to the common
medium. Collision Detection means a host detects whether its transmission has
collided with the transmission of another host (or hosts).
IFE Ethernet interface can be connected to a PC or a laptop over Ethernet. The
maximum length of Ethernet cable is 325 feet (100 meters). IFE Ethernet interface
+ gateway provides a Modbus TCP/IP gateway over Ethernet to enable Modbus
TCP communication from a Modbus TCP master to any Modbus slave devices
connected to it. The maximum active Modbus TCP client connection is twelve.
IFE Ethernet interface has an embedded web server (web page).
68 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
0613CT0001 69
Class 0613 MicroLogic™ Electronic Trip Systems
C
24VD C
24VD
ETH2 ETH2
2 2
ETH
ETH1 ETH1
ETH
1 1
ETH ETH
II J I JJ
set) set)
I
(factory tory
.YY.ZZ .YY.ZZ
(fac
IFE_XX IFE_XX
/ACT /ACT
10-100 10-100
1 LK/ 1 LK/
IFE ETH /ACT ETH /ACT
2 LK/
10-100 IFE 10-100
ETH tus 2 LK/
e Sta ETH
e Sta
tus
Modul Modul
tus
k Sta k Sta
tus
Networ Networ
s-SL s-SL
Modbu Modbu
11
LV4340 LV4340
11
or
or
I6
C
I5
I4
C
I3
I2
C
I1
ULP system I2
I3
C
I4
I5
C
I6
ULP system
C
I1
+ C
24VD
A1
O1
I1
O2
I2
O3
I3
APP I4
I5
I6
dule
IO Mo
FF HH O1 23
O2
24
33
O3
34
T1
A1
T2
14
13
G
DD
MX1 FF CT
CC
XF CD CE
B
B EE
OF C
C
SD MX1 - XF
SDE D
D
AA
PF
CH B
B
OF
SDE
PF A
A
CH
A BCM ULP
OF, SDE, SD, PF, CH (tripped, Open/closed, overcurrent trip, ready to close, charged
B
Switches
G IO Application Module
H ULP Cable
I IFE Module
J IFM Module
70 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Mounting
The IFE interface and IFE interface + gateway are DIN rail mounted devices. A
stacking accessory enables the user to connect several IFMs (ULP to Modbus
interfaces) to an IFE interface + gateway without additional wiring.
0613CT0001 71
Class 0613 MicroLogic™ Electronic Trip Systems
Characteristic Value
Modbus RTU, RS485 serial connection
Type of interface module
Modbus TCP/IP Ethernet
• Transfer rate: 9,600–19,200 Baud
72 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Table 35 - Characteristics
General Characteristics
Environmental Characteristics
Conforming to standards UL 508, UL 60950, IEC 60950, 60947-6-2
Pollution Level 3
Mechanical Characteristics
Conforming to IEC 60068-2-27 15g/11ms, 1/2
Shock resistance
sinusoidal
Electrical Characteristics
Power Supply 24 Vdc, -20%/+10% (19.2 to 26.4 Vdc)
Physical Characteristics
Rated power 72 W
0613CT0001 73
Class 0613 MicroLogic™ Electronic Trip Systems
Statistics X
Device information X
IMU (circuit breaker) information X
Communication check X
Maintenance Web Page
Maintenance log X
Maintenance counters X
Setup Web Page
Device localization/name X
Ethernet configuration (dual port) X
IP configuration X
Serial port X
Alarms to be e-mailed X
Device list X
Device logging X
SNMP parameters X
Documentation links X
Preferences X
Advanced services control X
User accounts X
74 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
ETH1 ETH2
B 24 Vdc power supply terminal block
I Locking pad
L ULP ports
0613CT0001 75
Class 0613 MicroLogic™ Electronic Trip Systems
Characteristics
ULP Port
Two RJ45 sockets, internal parallel wiring.
• Connection of a single circuit breaker.
• A ULP line terminator or an FDM121 display unit must be connected to the
second RJ45 ULP socket.
• The RJ45 sockets deliver a 24 Vdc supply fed from the Modbus socket.
• Built-in test function, for checking the correct connection to the circuit breaker
and FDM121 display unit.
Modbus Slave Port
• Top socket for screw-clamp connector, providing terminals for:
— 24 Vdc input supply (0 V, +24 V)
— Modbus line (D1, D2, Gnd) 2-wire Modbus system
• Lateral socket, for DIN-rail stackable connector. Both top and lateral sockets
are internally parallel wired.
• Multiple IFMs can be stacked, thus sharing a common power supply and
Modbus line without individual wiring.
• On the front face:
— Modbus address setting (1 to 99): two coded rotary switches
— Modbus locking pad: enables or disable the circuit breaker remote control
and modification of IFM parameters
• Self-adjusting communication format (Baud rate, parity).
A
A B Modbus Address Switches
C Modbus Traffic LED
F Test Button
6
5
4 7
3
2
8
9
BB G Mechanical Lock
1 0
6
5
4
3
7
8
H ULP RJ45 Connectors
C
2 9
0
1
C
Stacking Accessory
DD I
Connection
Test E
E
FF
II HH G
G
76 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Technical Characteristics
Table 36 - IFM Modbus Communication Interface
CE IEC/EN 60947-1
0613CT0001 77
Class 0613 MicroLogic™ Electronic Trip Systems
IO Application Module
Description
The IO (Input/Output) application module for an low-voltage circuit breaker is part
IO Application Module of an ULP system with built-in functions and applications to enhance the
application needs. The ULP system architecture can be built without any
restrictions using the wide range of circuit breakers.
The IO application module is compliant with the ULP system specifications.
Two IO application modules can be connected in the same ULP network.
The ranges of low-voltage circuit breakers enhanced by the IO application module
are:
• MasterPact NW
• MasterPact NT
• PowerPact R-Frame
• PowerPact P-Frame
Pre-Defined Application
The pre-defined application adds new functions to the IO application module by:
• Selection by the application rotary switch on the IO application module,
defining the application with pre-defined input/output assignment and wiring
diagram.
• No additional setting with the customer engineering tool required.
The resources not assigned to the pre-defined application are free for additional
user-defined applications:
• cradle management
• circuit breaker operation
• cradle management + ERMS (Energy Reduction Maintenance Setting)
NOTE: Use only MicroLogic P or H trip units with the blue ERMS label for
energy reduction maintenance setting systems. Review the IO module
user guide 0613IB1317 and ERMS installation instructions NHA67346 for
details on installation, testing, and operation of the ERMS system.
• light and load control
• custom
78 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
User-Defined Applications
User-defined applications are processed by the IO application module in addition
to the pre-defined application selected.
The user-defined applications are available depending on:
• the pre-defined application selected
• the IO application module resources (inputs and outputs) not used by the
application
The resources required by user-defined applications are assigned using the
customer engineering tool:
• protection
• control
• energy management
• monitoring
Mounting
The IO application module is a DIN rail mounted device. Install on a steel DIN rail
that is properly grounded near the device.
0613CT0001 79
Class 0613 MicroLogic™ Electronic Trip Systems
I1 C I2 I3 C I4 I5 C I6
O ULP connectors
13 14 23 24 33 34 T1 T2
1
2
O
O NN
General Characteristics
Conforming to standards UL 508, UL 60950, IED 60950, 60947-6-2
Pollution Level 3
80 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
General Characteristics
Rated power 72 W
NOTE: For a length greater than 10 m (33 ft) and up to 300 m (1,000 ft), it is mandatory to use a
shielded twisted cable. The shield cable is connected to the IO functional ground of the IO
application module.
Contact resistance 30 mΩ
18000 operations/hr (Mechanical)@1800 operations/hr
Maximum operating frequency
(Electrical)
The IO application module analog input can be connected to a Pt100 temperature sensor
Refresh interval 5s
0613CT0001 81
Class 0613 MicroLogic™ Electronic Trip Systems
Ethernet Ethernet
24 Vdc
24 Vdc
I6
C
C I5
24VD I4
C
I3
I2
C
I1
ETH2 C
I6
I5
2 C
I4
ETH
ETH1 I2
I3
1 C
ETH I1
+ C
24VD
24VDC
A1
ETH2
O1
O2
2 O3
ETH
ETH1
K
1
K
ETH
ule
IO Mod
A1
T2
O3 T1
34
11 33
LV4340
O2
24
O1 23
14
13
AA
B
B
A
A
C
C
BB
J
J
II
H
H
D
D
E
E
C
C
FF
G
G
DD
E
E
A IFE Ethernet interface for low-voltage circuit breaker A IFE Ethernet interface for low-voltage circuit breaker
D BCM ULP communication module D Circuit breaker disconnected position contact (CD)
82 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Modbus Modbus
I6
C
I5
I4
C
I3
I2
C
I1
I6
C
I5
I4
C
I3
I2
C
I1
+ C
24VD
A1
O1
I1
O2
O3
ule
KK
IO Mod
A1
T2
O3 T1
34
O2 33
24
O1 23
14
A
13
A
A B
B
C
C
B
B
J
J
II
D
HH
D
C
C E
E
F
F
D
D G
G
E
E
A IFM Ethernet interface for low voltage circuit breaker A IFM Ethernet interface for low voltage circuit breaker
D BCM ULP communication module D Circuit breaker disconnected position contact (CD)
0613CT0001 83
Class 0613 MicroLogic™ Electronic Trip Systems
References:
The EcoStruxure Power Commission software package can be downloaded from
our website:
www.se.com
84 0613CT0001
MicroLogic™ Electronic Trip Systems Class 0613
Features
The EcoStruxure Power Commission Software includes the Schneider Electric
customer engineering tools such as the Remote Setting Utility (RSU) and Remote
Control Utility (RCU) with additional features.
The EcoStruxure Power Commission Software supports the connection of
Schneider Electric communicable devices to:
• create projects by device discovery, selection of devices, and importing a Bill
of Material (BOM)
• monitor the status of protection and IO status
• read information (alarms, measurements, parameters)
• check protection discrimination between two devices
• upload and download of configuration or settings in batch mode to multiple
devices.
• carry out commands and tests
• generate and print a device settings report and communication test report
• manage multiple devices with a electrical and communication hierarchy
model
• manage artifacts (project documents)
• check consistency in settings between devices on a communication network
• compare configuration settings between PC and device (online)
• download latest firmware
The EcoStruxure Power Commission Software enables the user to access the
advanced features of the software once the project is saved in the Schneider
Electric cloud.
0613CT0001 85
Class 0613 Accessories
Accessories
Options for Remote Operation
Two options are available for remote operation of MasterPact circuit breakers:
direct connection or a communication network.
NOTE: When remote operation features are used, a minimum of four seconds
is required for the spring charging motor (MCH) to completely charge the
circuit breaker closing springs prior to actuating the shunt close (XF) device.
The wiring diagrams for these two options are shown below.
86 0613CT0001
Accessories Class 0613
Terminals
Table 37 - Terminal Characteristics
Terminal
Standards UL 486E
Termination Capacity 22–14 AWG solid or stranded wire with max. O.D. of
insulation 3.5 mm
Nominal 10 A
Current
Minimum 100mA at 24 V
22 AWG = 4.5 lbs. (20 N)
0613CT0001 87
Class 0613 Accessories
Characteristics MCH
48/60, 100/130, 200/250, 240/277, 380/415,
Vac 50/60 Hz 400/440, 480
Voltage Ratings (Vn)
Vdc 24/30, 48/60, 100/125, 200/250
CH Contact 10 A at 240 V
Shunt 57 ft. 34 ft. 314 ft. 200 ft. 1503 ft. 944 ft.
Trip (MX) 100% (17.4 m) (10.4 m) (95.7 m) (61.0 m) (457.8 m) (287.7 m)
and
Shunt
27 ft. 17 ft. 205 ft. 126 ft. 957 ft. 601 ft.
Close 85% (8.2 m) (5.2 m) (62.5 m) (38.4 m) (291.7 m) (183.2 m)
(XF)
33. The length shown in the table is for each of the two supply wires.
88 0613CT0001
Accessories Class 0613
Shunt Trip (MX1) and Shunt Trip (MX1): When energized, the shunt trip instantaneously opens the
Shunt Close (XF) circuit breaker. The shunt trip may be energized continuously or intermittently.
Shunt Close (XF): Remotely closes the circuit breaker if the spring mechanism is
charged.
NOTE: Do not use a standing close order on the shunt close coil (XF). Any
opening order will open the circuit breaker so a standing close order is not
necessary. See Anti-Pump Feature in .
Communication versions of the MX1 and XF are available for direct connection via
the circuit breaker communication module (BCM ULP).
Power Consumption
Steady-State/Inrush 4.5/200
(VA or W)
34. Shunt trip (MX1) and shunt close (XF) circuits must be energized for minimum of 200 ms.
0613CT0001 89
Class 0613 Accessories
Characteristics MN
24 Vac
48 Vac
120 Vac
Vac 50/60 Hz 240 Vac
277 Vac
380 Vac
Voltage Ratings (Vn)
480 Vac
12 Vdc
24 Vdc
Vdc 48 Vdc
125 Vdc
250 Vdc
Power Consumption (VA or W) Constant/Inrush 4.5/200
NW 90 ms ±10
Circuit Breaker Response Time at Vn
NT 40 ms ±10
90 0613CT0001
Accessories Class 0613
Maximum Number of
1
Contacts
Standard: 100 mA/24V minimum Low-Level: 2 mA/15 V minimum
load load
240/380 Vac 5A 24/48 Vac 3A
0613CT0001 91
Class 0613 Accessories
92 0613CT0001
Accessories Class 0613
240/380 6A 10 A
Vac 480 6A 10 A
600/690 6A 6A
24/48 Vac 5A 6A
Vac 240 Vac 5A 6A
380 Vac 5A 3A
24/48 Vdc 5/2.5 A 6A
Vdc 125 Vdc 0.5 A 6A
250 Vdc 0.3 A 3A
0613CT0001 93
Class 0613 Accessories
Maximum Number of
8a/8b Form C
Contacts
Standard: 100 mA/24 V Low-Level: 2 mA/15 V
Minimum Load Minimum Load
240/380 Vac 6A 24/48 Vac 5A
480 Vac 6A 240 Vac 5A
Breaking Capacity at a
Power Factor (p.f.) of 0.3 600/690 Vac 6A 380 Vac 5A
24/48 Vdc 2.5 A 24/48 Vdc 2.5 A
125 Vdc 0.8 A 125 Vdc 0.8 A
250 Vdc 0.3 A 250 Vdc 0.3 A
NT NW
Circuit Breaker Type
CE CD CT CE CD CT
Maximum Push-In Switches with Standard
3 2 1 335 335 335
Actuators
9 0 0
6 3 0
With Additional Actuators
3 6 0
6 0 3
Standard (100 mA/24 V minimum load)
240 8A 8A
380 8A 8A
Vac
480 8A 8A
600/690 6A 6A
Breaking Capacity
at a Power Factor 24/48 2.5 A 2.5 A
(p.f) of 0.3
Vdc 125 0.8 A 0.8 A
250 0.3 A 0.3 A
Low-Level (2 mA/15 V minimum load)
24/48 5A 5A
Vac
240 5A 5A
94 0613CT0001
Accessories Class 0613
NT NW
Circuit Breaker Type
CE CD CT CE CD CT
380 5A 5A
24/48 2.5 A 2.5 A
Vdc 125 0.8 A 0.8 A
250 0.3 A 0.3 A
CE CD CT
1b 1a 1b
1b 1a, 1b 1b
1a, 2b 1a, 2b 1a
1a, 2b 2a, 1b 1b
2a, 1b 1a, 2b 1b
1a 1a 1a
3a 3a 1a
3b 3b 1b
0613CT0001 95
Class 0613 Accessories
External Sensor for Source Ground-Return (SGR) and Modified Differential Ground-
Fault (MDGF) Protection
NOTE: MDGF and SGR are for use on circuit breakers with 400 A and higher
sensors.
For SGR System: The sensor is installed around the connection of the transformer
neutral point to ground and connects to the MicroLogic 6.0A, 6.0P or 6.0H trip
units. SGR requires a modified differential ground-fault (MDGF) sensor and
MDGF interface module to connect to the trip unit.
For MDGF System: An MDGF sensor is installed on each phase and neutral of
each circuit breaker and connects to the MicroLogic trip unit through an MDGF
module. See MDGF Instruction Bulletin 48049-182.
Sensor Plugs
Sensor plugs (standard) are used to set the sensor rating (In) of the circuit breaker,
Sensor Plug are field replaceable and are offered at 50–100% of frame rating. For a complete
list of available sensor plugs see selection information in .
96 0613CT0001
Accessories Class 0613
Type A36 0.4 0.45 0.5 0.6 0.63 0.7 0.8 0.9 1
UL Listed/ Type D 0.4 0.48 0.64 0.7 0.8 0.9 0.93 0.95 1
ANSI
Certified Type E 0.6 0.7 0.75 0.8 0.85 0.9 0.93 0.95 1
Type G 0.66 0.68 0.7 0.72 0.74 0.76 0.78 0.8 0.82
Type H 0.48 0.5 0.52 0.54 0.56 0.58 0.6 0.62 0.64
Type R36 0.4 0.5 0.6 0.7 0.8 0.9 0.95 0.98 1
Type S 0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8
IEC Rated Type T 0.8 0.82 0.85 0.88 0.9 0.92 0.95 0.98 1
Type P
No long-time protection.
(off plug)
36. Standard.
0613CT0001 97
Class 0613 Accessories
98 0613CT0001
Accessories Class 0613
Fault 1—The upstream circuit breaker (A) will clear the fault with no intentional
delay, regardless of its time-delay setting.
Fault 2—Circuit breaker (B) will inform upstream circuit breaker (A) that it is
clearing the fault. This will prevent circuit breaker (A) from tripping
instantaneously. Circuit breaker (A) will trip at the end of its time delay setting if the
fault is not cleared during this time.
0613CT0001 99
Class 0613 Accessories
Table 51 - RIM Requirements (R Denotes that a Restraint Interface Module (RIM) is required.)
37. Includes 2.0A (as a downstream trip unit only), 5.0A, 5.0P, 5.0P, 5.0H, 6.0A, 6.0P, and 6.0H trip units.
38. Number denotes maximum number of upstream circuit breakers that can be restrained without requiring a RIM.
100 0613CT0001
Accessories Class 0613
Cradle Connections
Table 52 - MasterPact NW UL Listed/ANSI Certified 3P/4P Drawout Circuit Breakers (Rear Connections)
800 to 2000 A
2500 to 3000 A
Rear-Connected
“T” Vertical
(RCTV)
3200 A (L1)
4000 to 5000 A
6000 A
800 to 2000 A
Rear-Connected
“T” Horizontal
(RCTH) 2500 to 3000 A
3200 A (L1)
4000 to 5000 A
Rear-Connected
3200 A
Offset Vertical
2000 A (L1/L1F)
(RCOV)
0613CT0001 101
Class 0613 Accessories
Table 53 - MasterPact NW UL Listed/ANSI Certified 3P/4P Drawout Circuit Breakers (Front Connections)
800 to 2000 A
Front-Connected
Flat (FCF)
3200 A (L1)
4000 A
800 to 3000 A
Front-Connected
“T” (FCT)
3200 A (L1)
4000 to 5000 A
102 0613CT0001
Accessories Class 0613
Table 54 - MasterPact NW UL Listed/ANSI Certified 3P/4P Fixed Circuit Breakers (Rear Connections)
800 to 2000 A
2500 to 3000 A
Rear-Connected
“T” Vertical
(RCTV)
4000 to 5000 A
06133700
6000 A
800 to 2000 A
Rear-Connected
“T” Horizontal
2500 to 3000 A
(RCTH)
4000 to 5000 A
Rear-Connected
Offset Vertical 3200 A
(RCOV)
06135503
06135504
Rear-Connected
4000 A (B) (W-
Offset Vertical
Frame)
(Special)
0613CT0001 103
Class 0613 Accessories
Table 55 - MasterPact NW UL Listed/ANSI Certified 3P/4P Fixed Circuit Breakers (Front Connections)
Front-Connected
Flat (FCF) 800 to 2000 A
Front-Connected
“T” (FCT) 800 to 3000 A
Front-Connected
Flat (FCF) 3200 A
800 to 3200 A
Rear-Connected
“T” Vertical
(RCTV)
4000 A
104 0613CT0001
Accessories Class 0613
5000 A
6300 A
800 to 3200 A
Rear-Connected
“T” Horizontal
(RCTH)
4000 A
0613CT0001 105
Class 0613 Accessories
4000b, 5000 A
Front-Connected
Flat (FCF) 800 to 3200 A
800 to 3200 A
Rear-Connected 4000 A
“T” Vertical
(RCTV)
4000b, 5000 A
106 0613CT0001
Accessories Class 0613
6300 A
800 to 3200 A
Rear-Connected
“T” Horizontal
(RCTH) 4000 A
4000b, 5000 A
0613CT0001 107
Class 0613 Accessories
Table 58 - MasterPact NT UL Listed/ANSI Certified 3P/4P Fixed and Drawout Circuit Breakers
108 0613CT0001
Accessories Class 0613
Table 59 - MasterPact NT IEC Rated 3P/4P Fixed and Drawout Circuit Breakers
0613CT0001 109
Class 0613 Accessories
Test Equipment
Hand-Held Test Kit
The hand held test kit may be used to:
Hand-Held Test Kit
• Verify trip unit operation, the mechanical operation of the circuit breaker, and
the electrical continuity of the connection between the trip solenoid and the
trip unit.
• Supply control power to the trip unit for settings via the keypad when the
circuit breaker is open (MicroLogic type A, P or H trip units).
• Inhibit thermal imaging for primary injection test (MicroLogic type A, P or H
trip units).
• Inhibit ground fault for primary injection test (MicroLogic type A, P or H trip
units).
• Self-restrain zone-selective interlocking (ZSI).
110 0613CT0001
Accessories Class 0613
0613CT0001 111
Class 0613 Accessories
A B C
D
G
F
E
C Interlocking Cables
F Interlocking Bracket
G Calibration Tray
112 0613CT0001
Accessories Class 0613
0613CT0001 113
Class 0613 Accessories
Rail Padlocking
Rail padlocking is standard for UL, ANSI, and IEC cradles. When used in
combination with the disconnected position locking device, rail padlocking
prevents the movement of the circuit breaker from the disconnected position to the
fully withdrawn position when the padlock hasp is pulled out and locked.
Miscellaneous Accessories
Mechanical Operation Counter (CDM)
The mechanical operation counter (CDM) registers the total number of operating
Mechanical Operation cycles. One CDM is installed per circuit breaker.
Counter (CDM)
114 0613CT0001
Accessories Class 0613
NW Cradle
Remote
Racking
Device
Controller
0613CT0001 115
Class 0613 Wiring Diagrams
Wiring Diagrams
Wiring Diagrams for MasterPact NW Circuit Breakers
Figure 23 - Wiring Diagrams for MasterPact NW Circuit Breakers
Power Trip Unit Remote Operation
D
C
NOTE: All diagrams show circuit breaker open, connected and charged.
A Do not remove factory-installed jumpers between Z3, Z4 and Z5 unless ZSI is connected.
C For proper wiring of neutral CT, refer to Instruction Bulletin 48041-082-01 shipped with it.
24 Vdc power supply for trip unit must be separate and isolated from 24 Vdc power supply
D
for communication modules.
When remote operation features are used, make sure there is a minimum of four seconds
E for the spring charging motor (MCH) to completely charge the circuit breaker closing
springs prior to actuating the shunt close (XF) device.
834 824 814 E5 E6 Z5 M 1 M 2 M 3 F2+ V3 484/Q 3 184/K2 84 334 324 314 D 2/C 12 C2 A2 254 B2
831 821 811 E1 E2 Z1 Z2 T1 T2 F1– V1 471/Q 1 181/K1 81 331 321 311 D 1/C 11 C1 A1 251 B1
or
C E6 C E5 C E4
116 0613CT0001
Wiring Diagrams Class 0613
244 234 224 214 144 134 124 114 44 34 24 14 934 924 914
242 232 222 212 142 132 122 112 42 32 22 12 932 922 912
241 231 221 211 141 131 121 111 41 31 21 11 931 921 911
or or or or
EF24 EF23 EF22 E F21 EF14 EF 13 EF12 EF1 1 CD6 C D5 CD 4 CE9 CE 8 C7
248 238 228 218 148 138 128 118 864 854 844 394 384 374
246 236 226 216 146 136 126 116 862 852 842 392 382 372
245 235 225 215 145 135 125 115 861 851 841 391 381 371
39. Fixed-mounted circuit breaker does not have cell switches (CE, CD, CT).
0613CT0001 117
Class 0613 Wiring Diagrams
A
E
C D
NOTE: All diagrams show circuit breaker open, connected and charged.
A Do not remove factory-installed jumpers between Z3, Z4 and Z5 unless ZSI is connected.
C For proper wiring of neutral CT, refer to Instrucion Bulletin 48041-082-01 shipped with it.
24 Vdc power supply for trip unit must be separate and isolated from 24 Vdc power supply
D
for communication modules.
When remote operation features are used, make sure there is a minimum of four seconds
E for the spring charging motor (MCH) to completely charge the circuit breaker closing
springs prior to actuating the shunt close (XF) device.
Remote Operation
D2 / C12 C2 A2 254 B2
C13 C3 A3 252 B3
D1/C11 C1 A1 251 B1
118 0613CT0001
Wiring Diagrams Class 0613
9 11
“Spring
Charged“ R
Light
440/480 V
B3 B2
CH
MCH
380V
B1
CN2 - 440/480 V
0613CT0001 119
Class 0613 Wiring Diagrams
OF4
Open/Closed Circuit OF24: Open/Closed Circuit Breaker or Switch Position
OF3
Breaker or Switch Contact or EF24: Combined Connected and Closed
OF2
Position Contacts Contact
OF1
OF23 or EF23
OF22 or EF22
OF21 or EF21
OF14 or EF14
OF13 or EF13
OF12 or EF12
OF22 or EF22
OF11 or EF11
Cradle Contacts
CD3 Disconnected CE3 Connected CT3
Test Position
CD2 Position CE2 Position CT2
Contacts
CD1 Contacts CE1 Contacts CT1
or or
CE6 Connected CE9 Connected
CE5 Position CE8 Position
CE4 Contacts CE7 Contacts
or
CD6 Disconnected
CD5 Position
CD4 Contacts
Trip Unit
Basic A P H
X X X Com: E1–E6 Communication
X X X Z1 = ZSI OUT
Remote Operation
120 0613CT0001
Wiring Diagrams Class 0613
Remote Operation
PF Ready-to-Close Contact
E1 E2 E3 E4 E5 E6
Circuit Breaker
Communication
Module (BCM)
Wiring of the COM varies with available options. See Wiring Diagrams for the
COM Option, page 122.
24 Vdc power supply for trip unit must be separate and isolated from 24 Vdc power
A supply for communication modules.
B Refer to instructions bulletin 48041-082 included with neutral CT for proper wiring.
0613CT0001 121
Class 0613 Wiring Diagrams
Induced voltages in the circuit at terminal C2 and/or A2 can cause the shunt trip or
shunt close to not work properly. The best way to prevent the induced voltages is
keep the circuit to terminal C2 and A2 as short as possible. If it is impossible to
keep the circuit less than 10 feet (3 m), use an interposing relay near terminal C2
or A2.
ULP cord
IO Module
Circuit Breaker
ULP cord
Black White
Red Blue
E1 E2 E3 E4 E5 E6
Circuit Breaker
Microswitches Communication
Connected to BCM Module (BCM)
122 0613CT0001
Wiring Diagrams Class 0613
Wiring of the COM Option (Modbus BCM ULP and CCM Modules
AA. Modbus RS 485 4-wire AA. Modbus RS 485 2-wire BB. Modbus RS 485 2-wire + ULP
without ULP module without ULP module with ULP module
External power supply External power supply External power supply
24 V c
- + 24 V c
- + 24 V c
- +
A
Micrologic P/H + - + - + -
Modbus
EGX100 EGX100 EGX100
Com
Address Rx- Rx+ Tx- Tx+ Rx- Rx+ Tx- Tx+ Rx- Rx+ Tx- Tx+
47
The B configuration is
Baud-rat
e
19.2 k
4W, 2W+UL
P
only possible with CCM
4wires marked Schneider Electric
on the front face.
B
B
Micrologic P/H + - + - + - + -
Network
Network
Network
FDM121
Modbus A B A’ B’ A B A’ B’ A B A’ B’
Com version > V2.0.2
Address
CCM CCM CCM
Breaker
Breaker
Breaker
Baud-rate
19.2 k
A B A’ B’ A B A’ B’ A B A’ B’
4W, 2W+UL
P
2w+ULP + - + - + -
Circuit Breaker
ULP Cord
Red Black White Blue
E1 E2 E3 E4 E5 E6 E1 E2 E3 E4 E5 E6 E1 E2 E3 E4 E5 E6
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
customer terminal block customer terminal block customer terminal block
0613CT0001 123
Class 0613 MasterPact NT Dimensional Drawings
6.12 4.97
(155,5) (126,3)
3.69 3.71
(93,8) (94,3)
1. Rear Panel
2. Front Door
3. Distance to Drawout Position: 8.27 in. (210 mm)
4. Crank Handle Extension to Mounting Surface: Add 2.36 in. (60 mm)
5. Distance from Connect to Drawout Position: 1.81 in. (46 mm)
6. Rear Panel Mounting Holes
2.76 2.76
(70,0) (70,0) 0.94
(24,0)
8.50
3.91 3.91 (216,0)
(99,3) (99,3)
0.33
(8,4)
0.98 9.10
(25,0) (231,3)
2.95 7.83
(75,0) (199,0)
5.91
4.49 (150,0) 8.27 4.84
(113,9) (210,0) (123,0)
5.91
(150,0) 0.0
4.29 1.51 (0,0)
4.29 (38,5) 1.79
(109,0) (109,0) (45,5)
in
Dimensions: (mm)
124 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
(100,0)
3.94
Ø0.23
(6,0)
(44,0)
1.73
Ø0.43
(11,0) 0.87 0.75
(22,0) 1.73 (19,0)
(44,0) Z
Top View 6.89
(175,0)
Y 2.64
6.34 5.04
(161,0) (128,0) (67,0)
90.00
(90,0)
(199,0)
7.83
(75,0)
0.39
2.95
(10,0)
(228,0)
(150,0)
5.91
8.98
X
(114,0)
(123,0)
4.49
4.84
in
Dimensions: (mm)
0613CT0001 125
Class 0613 MasterPact NT Dimensional Drawings
(100,0)
3.94
Ø0.23
(6,0)
(44,0)
1.73
Ø0.43
(11,0) 0.87 0.75
(22,0) 1.73 (19,0)
(44,0) Z
Top View 6.89
(175,0)
Y 2.64
6.34 5.04
(161,0) (128,0) (67,0)
90.00
(90,0)
(199,0)
7.83
(75,0)
0.39
2.95
(10,0)
(228,0)
(150,0)
5.91
8.98
X
(114,0)
(123,0)
4.49
4.84
in
Dimensions: (mm)
126 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
25.00
100.00
Ø0
(6, .25
0)
(135,0)
5.31
(75,0)
2.95
(150,0)
5.91
(123,0)
(135,0)
4.84
5.31
(44,0)
1.73
(22,0)
0.75
1.73
(44,0) 2.76 2.76
(70,0) (70,0)
Back View Side View
in
Dimensions: (mm)
Y
9.02 10.20 9.02 10.20
(229,0) (259,0)
(229,0) (259,0)
X
(258,0)
(302,0)
11.89
10.16
X
(109,0)
(130,0)
4.29
5.12
6.30
(160,0) 7.17
10.16 (182,0)
(258,0)
12.05
19.21 (306,0)
(488,0)
19.21
(488,0)
in
Dimensions: (mm)
0613CT0001 127
Class 0613 MasterPact NT Dimensional Drawings
DRAWOUT
3.94
(100,0)
0.27
(6,8)
FIXED
4.92 4.92
(125,0) (125,0) 4.92 7.68
(125,0) (195,0)
0.98
(25,0)
3.94
(100,0)
0.33
(8,5)
in
Dimensions: (mm)
128 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
0.33
3.94
(8,5)
(100,0)
5.39
(136,9)
1.0
2.76 2.76 (25,40)
(70,0) (70,0)
4.13
(105,0)
0.26
8.27 (6,7)
(210,0)
11.40
2.46 0.33 (289,6)
(62,5) (8,5)
5.34
(135,8)
2.94 4.11
(74,6) (104,5)
4.92 6.10 5.89
(125,0) (155,0) (149,6) 7.00
8.27 (177,7)
(210,0)
4.84
3.05 (123,0)
(77,5)
0.59
(15,0) 1.55
(39,4)
in
Dimensions: (mm)
0613CT0001 129
Class 0613 MasterPact NT Dimensional Drawings
(25,0)
(125,0)
0.98
(100,0)
3.94
(44,0)
1.73
0.87
Ø0 1,0)
(22,0)
(19,0)
(1
0.75
.43
1.73
(44,0)
2.76 2.76
(70,0) (70,0)
Top View
(178,0)
7.01
(136,0)
5.35
(105,0)
4.13
(75,0)
2.95
(210,0)
(150,0)
5.91
8.27
(123,0)
4.84
(10,0)
0.39
0.51 0.26
(13,0) (6,5)
10.87 0.59
(276,0) (15,0)
9.41 1.54
(239,0) (39,0)
in
Dimensions: (mm)
130 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
[25,0]
0.98
[125,0]
[100,0]
3.94
Ø
[8, 0.3
0] 3
0.39
0.20 [10,0]
[5,0]
2.76 2.76
[70,0] [70,0] Z
Top View
Ø0
Y [11 .43 4.04
.0] [102,5]
[178,0]
7.01
[136,0]
5.35
[105,0]
4.13
[75,0]
2.95
[210,0]
[150,0]
5.91
8.27
X
1.73
[44,0]
[123,0]
4.84
[44,0]
1.73
[22,0]
0.87
0.51 0.26
[13,0] 0.59 [6,5]
10.87 [15,0]
[276,0] 0.75 8.66 1.54
[19,0] [220,0] [39,0]
in
Dimensions: (mm)
0613CT0001 131
Class 0613 MasterPact NT Dimensional Drawings
(25,0)
0.98
(125,0)
(100,0)
3.94
Ø (8,0
0.3 )
Top View 3
1.73
(44,0)
(19,0)
0.75
0.87
(44,0)
(22,0) 0.63
1.73
(16,0)
(125,0)
4.92
(178,0)
7.01
(136,0)
(135,0)
5.31
(105,0)
5.35
4.13
(75,0)
2.95
(150,0)
(400,0)
15.75
5.91
(210)
8.27
(123,0)
(135,0)
4.84
5.31
0.51 0.59
(13,0) (15,0) 0.26
1.54 (6,5)
(39,0)
2.76 2.76 Ø0
(70,0) (70,0) (11 .43 7.17
,0) (182,0)
10.87
(276,0)
Back View Side View
in
Dimensions: (mm)
132 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
1.75
(44,5)
0.25 0.25 0.63
(6,2) (6,4) (15,9) 0.56
1.73 (14,3)
(43,8)
1.75
(44,5)
14.52
(368,9)
4.85
(123,1)
0.63
(16,0) 8.29
(210,6)
in
Dimensions: (mm)
Y
7.64 Min 7.64 Min Y
(194,0) (194,0) 7.64 Min 7.64 Min
(194,0) (194,0)
(216,0)
(266,0)
10.47
8.50
X X
(108,0)
(133,0)
4.25
5.24
3.82 4.80
(97,0) (122,0)
9.61
7.64 (244,0)
(194,0)
in
Dimensions: (mm)
0613CT0001 133
Class 0613 MasterPact NT Dimensional Drawings
DRAWOUT
3.94
(100,0)
0.27
(6,8)
FIXED
4.92 4.92
(125,0) (125,0) 4.92 7.68
(125,0) (195,0)
0.98
(25,0)
3.94
(100,0)
0.33
(8,5)
in
Dimensions: (mm)
134 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
1. Rear Panel
2. Front Door
3. Distance to Drawout Position: 8.27 in. (210 mm)
4. Crank Handle Extension to Mounting Surface: Add 2.36 in. (60 mm)
5. Distance from Connect to Drawout Position: 1.81 in. (46 mm)
2.76 8.50
2.76 (216,0)
(70,0) (70,0)
2.76
(70,0)
0.94
3.94 6.64 (24,0)
(100,1) (168,5)
0.98
(25,0)
0.33
(8,4) 7.83 9310
2.95 (231,3)
(75,0) (199,0)
4.49 3.94
(113,9) 4.11
(100,0) (104,5)
5.91 8.27
(150,0) 5.91 (210,0)
(150,0)
4.49 4.84
(113,9) (123,0)
1.51
4.32 7.02 (38,5) 1.78
(109,8) (178,2) (45,2)
in
Dimensions: (mm)
0613CT0001 135
Class 0613 MasterPact NT Dimensional Drawings
in
Dimensions: (mm)
136 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
(25,0)
(90,0) (160,0)
0.98
Z
(100,0)
3.94
Ø0
.
(8, 33
5)
0.39 Z
(10,0) 6.89 Min
(175,0)
Top View 2.64
Ø0 ,0)
(11
(67,0)
.43
(44,0)
(22,0)
0.87
1.73
(199,0)
7.83
(75,0)
2.95
(150,0)
(228,0)
5.91
8.98
X X
(123,0)
(114,0)
4.84
4.49
in
Dimensions: (mm)
0613CT0001 137
Class 0613 MasterPact NT Dimensional Drawings
3.54 Y 6.30
(25,0)
(90,0) (160,0)
0.98
Z
(100,0)
3.94
Ø0
,
(8, 33
5)
Top View Z
6.89 Min
(175,0)
Y
2.76 2.76 2.76 0.63 2.64
(70,0) (70,0) (70,0) (16,0) (67,0)
(199,0)
7.83
(135,0)
5.31
(75,0)
2.95
(150,0)
5.91
X X
(123,0)
(135,0)
4.84
5.31
1.79
(45,5)
(44,0)
1.73
0.87 1.73
(19,0)
(22,0) 11.18
0.75
3 (44,0)
0.4 (284,0)
Ø 1,0) 6.34 7.80
(1 (161,0) (198,0)
Back View Side View
in
Dimensions: (mm)
11.89
10.16
X X
(109,0)
(130,0)
4.29
5.12
6.30 7.17
(160,0) (182,0)
10.16 12.05
(258,0) (306,0)
in
Dimensions: (mm)
138 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
DRAWOUT
3.94
(100,0)
0.27
(6,8)
FIXED
4.92 4.92
(125,0) (125,0) 4.92 7.68
(125,0) (195,0)
0.98
(25,0)
3.94
(100,0)
0.33
(8,5)
in
Dimensions: (mm)
0613CT0001 139
Class 0613 MasterPact NT Dimensional Drawings
3.94
(100,0)
5.39 0.33 Door: 1.54 in. (39 mm) Maximum
(136,9) (8,5) 0.71 in. (18 mm) Minimum
1.00
0.8 (25,4)
(2,0)
2.76 2.76
(70,0) (70,0)
2.76
(70,0)
11.26
11.42
(286,0)
4.25 (290,1)
(108,0) 0.26
(6,7)
2.94
(74,6) 7.01
5.34 (178,0)
(135,7)
4.11
2.46 (104,5)
6.10
(62,5) (155,0)
5.89
4.92 (149,6)
(125,0) 3.05 4.84
8.27 (123,0)
(77,5) (210,0)
0.59
SIDE VIEW 1.55 (15,0)
(39,4)
in
Dimensions: (mm)
140 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
4.92 Y 7.68
(125,0) (195,0)
Ø (8,
(25,0)
0.3 5)
0.98
3
(100,0)
3.94
0.51
(13,0)
(44,0)
1.73
0.87
(22,0) (19,0)
.43
0.75
Ø0 1,0) 1.73
(1 (44,0)
Top View
(10,0)
0.39
(178,0)
7.01
(136,0)
5.35
(105,0)
X
4.13
(75,0)
2.95
(210,0)
(150,0)
5.91
8.27
X
(123,0)
4.84
in
Dimensions: (mm)
0613CT0001 141
Class 0613 MasterPact NT Dimensional Drawings
(25,0)
(125,0) (195,0)
0.98
Z
(100,0)
3.94
(8, 0.33
0.51
5)
Ø
(13,0)
0.39
2.76 2.76 2.76 (10,0)
(70,0) (70,0) (70,0)
4.02 Z
Top View (102,0)
1.73
(44,0)
0.73
(18,5)
(178,0)
7.01
(136,0)
5.35
(105,0)
4.13
(75,0)
2.95
(150,0)
(210,0)
5.91
8.27
X
(123,0)
4.84
(44,0)
(22,0)
1.73
0.87
Y 1.54
Ø0 1,0)
(1 (39,0)
.43 0.59
(15,0)
8.66
(220,0)
in
Dimensions: (mm)
142 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
(115,5)
(15,9)
0.62
4.55
(457,33)
18.0
(150,0)
5.91
2.11
(53,6)
(153,1)
6.03
(461,2)
18.16
(20,0)
0.79
(238,9)
9.40
4.00
(101.8) 4.00 3.50 4.53 3.50 4.53 3.50 1.06
(101.8) (88,9) (115,0) (88,9) (115,0) (88,9) (26,92)
8.00 21.67
(127.0) (550,4)
10.05
(255,3)
in
Dimensions: (mm)
0613CT0001 143
Class 0613 MasterPact NT Dimensional Drawings
Y
10.39 Min 7.64 Min Y
10.39 Min 7.64 Min
(264,0) (194,0) (264,0) (194,0)
(266,0)
(216,0)
10.47
8.50
X X
(108,0)
4.25
(133,0)
5.24
3.82 4.80
(97,0) (122,0)
9.61
7.64 (244,0)
(194,0)
in
Dimensions: (mm)
DRAWOUT
3.94
(100,0)
0.27
(6,8)
FIXED
4.92 4.92
(125,0) (125,0) 4.92 7.68
(125,0) (195,0)
0.98
(25,0)
3.94
(100,0)
0.33
(8,5)
in
Dimensions: (mm)
144 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
6.12 4.97
(155,5) (126,3)
3.69 3.71
(93,8) (94,3)
1. Rear Panel
2. Front Door
3. Distance to Drawout Position: 8.27 in. (210 mm)
4. Crank Handle Extension to Mounting Surface: Add 2.36 in. (60 mm)
5. Distance from Connect to Drawout Position: 1.81 in. (46 mm)
6. Rear Panel Mounting Holes
2.76 2.76
(70,0) (70,0) 0.94
(24,0)
8.50
3.91 3.91 (216,0)
(99,3) (99,3)
0.33
(8,4)
0.98 9.10
(25,0) (231,3)
2.95 7.83
(75,0) (199,0)
5.91
4.49 (150,0) 8.27 4.84
(113,9) (210,0) (123,0)
5.91
(150,0) 0.0
4.29 1.51 (0,0)
4.29 (38,5) 1.79
(109,0) (109,0) (45,5)
in
Dimensions: (mm)
0613CT0001 145
Class 0613 MasterPact NT Dimensional Drawings
3.54 Y 3.54
(25,0)
(90,0) (90,0)
0.98
Z
(100,0)
3.94
Ø0
(8, .33
5)
0.59
(15,0) Z 6.89 Min
Top View (175,0)
2.64
1.97 (67,0)
2.76 2.76 (50,0)
(70,0) (70,0) 0.51
(13,0)
Ø
(110.43
(22,0)
0.87
,0)
(114,0)
4.49
(228,0)
(150,0)
5.91
8.98
X
0.51
(13,0)
(123,0)
4.84
(44,0)
0.98
(25,0)
1.73
in
Dimensions: (mm)
146 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
3.54 Y 3.54
(25,0)
(90,0) (90,0)
0.98
Z
(100,0)
3.94
Ø0
.
(8,5 33
)
(13,0)
0.51
.43 0.98
Ø0 ,0) (25,0)
(11 0.87
(22,0) 1.73 Z
(44,0) 6.89 Min
(175,0)
Top View
2.64
1.93 (67,0)
(49,0)
(15,0)
0.59
(199,0)
7.83
(75,0)
2.95
(150,0)
(228,0)
5.91
8.98
X X
(114,0)
(123,0)
4.49
4.84
2.76 2.76
(70,0) (70,0)
9.09 1.79
6.34 5.04 (231,0) (45,5)
(161,0) Y (128,0)
10.55
(268,0)
Back View Side View
in
Dimensions: (mm)
0613CT0001 147
Class 0613 MasterPact NT Dimensional Drawings
3.54 Y 3.54
(25,0)
(90,0) (90,0)
0.98
Z
(100,0)
3.94
Ø0
(8, .33
5)
Top View
Z 6.89 Min
6.34 Y 5.04 (175,0)
(161,0) (128,0)
2.76 2.76 2.64
0.59 (67,0)
(70,0) (70,0) (15,0)
(199,0)
(171,0)
7.83
6.73
(75,0)
2.95
(336,0)
13.23
(150,0)
5.91
X X
(123,0)
(141,0)
4.84
5.55
(12,5)
0.49
0.98 9.09
(25,0) (231,0)
9.25 1.79
.43 0.87 1.73 (45,5)
Ø0 11,0) (22,0) (44,0)
(235,0)
(
in
Dimensions: (mm)
8.07
(205,0)
(8, 33
4.04
5)
.
Ø0
(102,5)
(150,0)
5.91
(234,0)
9.21
(50,0)
1.97
(117,0)
4.61
4.29 8.50
(109,0) (216,0)
8.58
(218,0)
in
Dimensions: (mm)
148 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
0.33
3.94
(8,5)
(100,0)
5.39
(136,9)
1.0
2.76 2.76 (25,40)
(70,0) (70,0)
4.13
(105,0)
0.26
8.27 (6,7)
(210,0)
11.40
2.46 0.33 (289,6)
(62,5) (8,5)
5.34
(135,8)
2.94 4.11
(74,6) (104,5)
4.92 6.10 5.89
(125,0) (155,0) (149,6) 7.00
8.27 (177,7)
(210,0)
4.84
3.05 (123,0)
(77,5)
0.59
(15,0) 1.55
(39,4)
in
Dimensions: (mm)
0613CT0001 149
Class 0613 MasterPact NT Dimensional Drawings
(25,0)
0
0.98
(8 .33 (125,0)
,5)
Z
(100,0)
3.94
0.51
(13,0)
0.30
(7,5)
0.59
2.76 2.76 (15,0)
(70,0) (70,0)
Y Z
Top View
Ø
(1 0.4 1.71
1,0 3
) (43,5)
(44,0)
1.73
(178,0)
7.01
(136,0)
5.35
(105,0)
4.13
(75,0)
2.95
(210,0)
(150,0)
5.91
8.27
X X
(123,0)
4.84
(25,0)
0.98
(22,0)
0.87
6.61 1.54
10.87 (168,0) (39,0)
(276,0)
0.51
(13,0)
in
Dimensions: (mm)
150 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
(25,0) (8 .33
,5)
9.84
0.98 Ø0
(250,0)
4.92
(125,0)
(100,0)
3.94
(12,5)
0.49
0.51
(13,0)
0.98
0.87 (25,0)
(22,0) 1.73
(11 0.43
Y (70,0) (70,0)
Ø
Y Z
Top View
1.71
(43,5)
(178,0)
7.01
(136,0)
(105,0)
5.35
4.13
(75,0)
2.95
(150,0)
(210,0)
5.91
8.27
X X
(123,0)
4.84
(15,0)
0.59
0.59
(15,0)
10.87 6.61 1.54
(276,0) (168,0) (39,0)
in
Dimensions: (mm)
0613CT0001 151
Class 0613 MasterPact NT Dimensional Drawings
(8, .33
5)
Ø0
9.84
(250,0)
4.92
(25,0)
0.98
(125,0)
(100,0)
3.94
0.51
(13,0)
Y
Top View
Ø0 Y
. 2.76 2.76
(11 43 Z
,0) (70,0) (70,0)
(178,0)
7.01
(150,0)
(136,0)
5.91
5.35
(105,0)
4.13
(75,0)
2.95
(326,0)
(210,0)
(150,0)
12.83
5.91
8.27
X X
(123,0)
4.84
(150,0)
5.91
0.59
(15,0)
0.98 0.47 1.54
(13,0)
(39,0)
0.51
(25,0) (12,0)
1.73 6.46
(44,0) (164,0)
10.87
(276,0)
Side View
Back View
in
Dimensions: (mm)
152 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
3.54 Y 3.54
(25,0)
(90,0) (90,0)
0.98
Z
(100,0)
3.94
Ø0
(8, .33
5)
0.59
(15,0) Z 6.89 Min
Top View (175,0)
2.64
1.97 (67,0)
2.76 2.76 (50,0)
(70,0) (70,0) 0.51
(13,0)
Ø
(110.43
(22,0)
0.87
,0)
(114,0)
4.49
(228,0)
(150,0)
5.91
8.98
X
0.51
(13,0)
(123,0)
4.84
(44,0)
0.98
(25,0)
1.73
in
Dimensions: (mm)
0613CT0001 153
Class 0613 MasterPact NT Dimensional Drawings
1. Rear Panel
2. Front Door
3. Distance to Drawout Position: 8.27 in. (210 mm)
4. Crank Handle Extension to Mounting Surface: Add 2.36 in. (60 mm)
5. Distance from Connect to Drawout Position: 1.81 in. (46 mm)
2.76 8.50
2.76 (216,0)
(70,0) (70,0)
2.76
(70,0)
0.94
3.94 6.64 (24,0)
(100,1) (168,5)
0.98
(25,0)
0.33
(8,4) 7.83 9310
2.95 (231,3)
(75,0) (199,0)
4.49 3.94
(113,9) 4.11
(100,0) (104,5)
5.91 8.27
(150,0) 5.91 (210,0)
(150,0)
4.49 4.84
(113,9) (123,0)
1.51
4.32 7.02 (38,5) 1.78
(109,8) (178,2) (45,2)
in
Dimensions: (mm)
154 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
3.54 Y 6.30
(25,0)
(90,0) (160,0)
0.98
Z
(100,0)
3.94
Ø0
(8, .33
5)
(1
2.76 Y 2.76 2.76 (49,0) (67,0)
1,0
)
(70,0) (70,0) (70,0)
0.49
(12,5)
(22,0)
0.87
(199,0)
7.83
(150,0)
(228,0)
5.91
8.98
X X
(123,0)
(114,0)
4.84
4.49
(25,0)
0.98
(44,0)
in
Dimensions: (mm)
0613CT0001 155
Class 0613 MasterPact NT Dimensional Drawings
(25,0)
0.98
Z
(100,0)
3.94
Ø0
(8,.33
5)
0.87 Ø
0.98 (110.43
(12,5)
(22,0)
0.49
(15,0)
0.59
(199,0)
7.83
(75,0)
2.95
(150,0)
(228,0)
5.91
8.98
X X
(114,0)
(123,0)
4.49
4.84
in
Dimensions: (mm)
156 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
[25,0]
0.98
Z
[100,0]
3.94
Ø0
[8, .33
5]
Top View
Z 6.89 Min
[175,0]
Y
2.64
2.76 2.76 2.76 [67,0]
[70,0] [70,0] [70,0] 0.59
[15,0]
[199,0]
7.83
[171,0]
6.73
[25,0]
2.95
[336,0]
13.23
[100,0]
5.91
X X
[123,0]
[140,0]
4.84
5.51
0.98 9.09
[12,5]
[231,0]
0.49
0.87 [25,0]
1.79
.43 ] [22,0] 1.73 9.25
Ø011,0 [44,0] [235,0] [45,5]
[ 6.34 7.80
[161,0] [198,0]
Back View Side View
in
Dimensions: (mm)
10.83
(275,0)
4.04
(8 0.33
(102,5)
,5)
Ø
(150,0)
5.91
(234,0)
9.21
(117,0)
4.61
(50,0)
1.97
109.00 8.50
(109,0) (216,0)
11.34
(288,0)
in
Dimensions: (mm)
0613CT0001 157
Class 0613 MasterPact NT Dimensional Drawings
3.94
(100,0)
5.39 0.33 Door: 1.54 in. (39 mm) Maximum
(136,9) (8,5) 0.71 in. (18 mm) Minimum
1.00
0.8 (25,4)
(2,0)
2.76 2.76
(70,0) (70,0)
2.76
(70,0)
11.26
11.42
(286,0)
4.25 (290,1)
(108,0) 0.26
(6,7)
2.94
(74,6) 7.01
5.34 (178,0)
(135,7)
4.11
2.46 (104,5)
6.10
(62,5) (155,0)
5.89
4.92 (149,6)
(125,0) 3.05 4.84
8.27 (123,0)
(77,5) (210,0)
0.59
SIDE VIEW 1.55 (15,0)
(39,4)
in
Dimensions: (mm)
158 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
(25,0) (8,5 3
.3
)
4.92 Y 7.68
Ø0
(125,0) (195,0)
0.98
Z
(100,0)
3.94
0.51
0.59 (13,0)
(15,0)
0.30
(7,5) 2.76 2.76 2.76
Y(70,0) (70,0) (70,0)
Z
Top View
Ø0 1.71
(11 .43 (43,5)
,0)
(178,0)
7.01
(136,0)
5.35
(105,0)
4.13
(75,0)
2.95
(210,0)
(150,0)
5.91
8.27
X X
(123,0)
4.84
(44,0)
(12,5)
1.73
0.98
0.49
(25,0)
(22,0)
0.87
0.59
13.62 (15,0)
(346,0) 1.54
(39,0)
0.49 6.59
(12,5) (167,5)
in
Dimensions: (mm)
0613CT0001 159
Class 0613 MasterPact NT Dimensional Drawings
(25,0) (8 0.33
,5)
Ø
Y
4.92 7.68
(125,0) (195,0)
0.98
Z
(100,0)
3.94
(167,5)
6.59
0.51
(13,0)
0.98
(12,5)
1.73 (25,0)
0.49
.43 0) (44,0)
Ø0(11, Top View
Y Z
5.43
(138,0)
1.71
(15,0)
0.59
(43,5)
(178,0)
7.01
(136,0)
5.35
(105,0)
4.13
2.95
(210,0)
(150,0)
5.91
8.27
X X
(123,0)
4.84
0.59
2.76 2.76 2.76 (15,0) 1.54
(70,0) (70,0) (70,0) (39,0)
13.62
(346,0)
in
Dimensions: (mm)
160 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
0.98
Z
(100,0)
3.94
0.51
(13,0)
Top View
Z
Ø
(11 0.43 2.76 Y 2.76 2.76
,0) (70,0) (70,0) (70,0) 1.06
(27,0)
(178,0)
(150,0)
7.01
(136,0)
5.91
(105,0)
5.35
4.13
(210,0)
(326,0)
(150,0)
12.83
5.91
8.27
X X
(123,0)
4.84
(150,0)
5.91
0.59
(15,0) 1.54
1.73 0.47 (39,0)
(13,0)
0.51
in
Dimensions: (mm)
Y
7.64 Min 7.64 Min Y
(194,0) (194,0) 7.64 Min 7.64 Min
(194,0) (194,0)
(216,0)
(266,0)
10.47
8.50
X X
(108,0)
(133,0)
4.25
5.24
3.82 4.80
(97,0) (122,0)
9.61
7.64 (244,0)
(194,0)
in
Dimensions: (mm)
0613CT0001 161
Class 0613 MasterPact NT Dimensional Drawings
8.20
(208,3)
6.95
(176,5)
0.94
(23,7)
1.38
(34,9)
0.56
(14,2)
4.44
(112,8)
5.04
(127,9)
0.62 5.38
(15,7) (136,7)
3.00
(76,2)
in
Dimensions: (mm)
8.20
(208,3)
6.95
(176,5)
0.94
(23,7)
1.38
(34,9)
0.56
(14,2)
4.44
(112,8)
5.04
(127,9)
0.62 5.38
(15,7) (136,7)
3.00
(76,2)
in
Dimensions: (mm)
162 0613CT0001
MasterPact NT Dimensional Drawings Class 0613
1.376
(35,0)
3.000
(76,2)
6.825
(173,4) 2.998
(76,2)
5.347
(135,8)
0.620
(15,7)
8.200
(208,3)
in
Dimensions: (mm)
0613CT0001 163
Class 0613 MasterPact NW Dimensional Drawings
164 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
(110) 5.25
9.39
(133)
15.36
(390)
(175)
(439)
C
17.3
6.89
L
X X
(201)
7.89
Y C
L
To Crank
CL
Min4
15.75 8.37 8.37 (9) 5.04 5.85
(400) (213) (213) Surface
3 13.74 (148) (149)
(349) 2.36
16.7 (60)
(425) Front Panel
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 165
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
166 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 167
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
168 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 169
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
170 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 171
Class 0613 MasterPact NW Dimensional Drawings
22.70 3.04
13.64 (576,6) (77,2)
(346,5) 0.75
4.59 (19,1)
(116,6)
0.62
(15,7)
1.94
Ø 0.56 (49,3)
(14,2)
1.75
(44,5)
20.68
(525,3)
1.00
(25,4)
4.53
(115,1)
0.62 1.75
(15,7) (44,5)
22.49
(571,2)
in
Dimensions: (mm)
172 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
8.37
(213) 8.37
(12 7
12.89 (213)
0.4
)
(328) 12.8 12.89
6.59
(168) 6.40 (325) (325)
11.12 (163) 26 17.72 17.72
0. ) (450) (450)
(283) (7
(110)
4.33
0.39
(10)
(250)
9.84
(175)
6.89
0.39
(10)
1.75
(44)
5.94
6.40 (151)
0. )
0. 6.38
35
(9
(163)
(7 26 ( (163)
) 3
Po
le
on
ly)
in
Dimensions: (mm)
10.63
(270)
0.71
(18)
1.85
(47)
6.40
(163)
12.80
(325)
in
Dimensions: (mm)
0613CT0001 173
Class 0613 MasterPact NW Dimensional Drawings
25.43 11.81
(646) (300)
10.63
(270)
(135)
(153)
5.31
6.02
0.71
(18)
6.37 1.85
(162) (47)
12.8
(325)
in
Dimensions: (mm)
10.63
(270)
(134)
(149)
5.28
5.85
0.75
(19)
2.72
2.81
(69)
(72)
1.85
(47)
7.09 7.09
(180) (180)
in
Dimensions: (mm)
174 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 175
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
176 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 177
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
1.48
(37,6)
1.75
(44,5)
0.98 0.31
(25,0) 7.75 1.98 (7,8)
6.82
(196,9) (173,4) (50,4) 2.56
(64,9)
0.37
4.90 (9,5)
15.12
(124,4) (384,0)
6.40
(162,5) 7.05 3.56 6.34
5.12 (90,3)
(130,0) (178,9) (161,0)
0.37
(9,5)
1.75 1.75
0.37 7.88 (44,5)
(200,1) (44,5)
(9,5) 0.43
15.75 (11,0) 0.62
(400,1) (15,7)
16.21
(411,6)
in
Dimensions: (mm)
178 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
3.75 3.25
(95,3) (82,6)
7.44 0.31
6.82
(189,1) (7,8) 2.56
(173,4)
(64,9)
17.75
(450,9)
6.34
9.69 (161,0)
10.31 (246,0)
(261,8) 1.75
(44,5)
0.62
(15,7) 1.75
7.84 7.84
(44,5)
(199.2) (199,2)
0.75
16.21
(19,1)
(411,6)
15.75
(400,1) ISOMETRIC VIEW
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 179
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
180 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
3.71
(93,9) 12.75 0.75
(323,9) (19,1)
21.81
(553,9) 0.62
(15,7) 1.94
0.56 (49,2)
(14,2)
1.75
(44,5)
17.49
(444,3)
1.00
7.68 (25,4)
(195,0)
1.75
0.62 (44,5)
(15,7) 16.02
(407,0)
in
Dimensions: (mm)
Figure 107 - 800–3200 A and 4000 A (W-Frame) Circuit Breaker Door Cutout
16.34 Min (4-Pole)
(415,0)
11.81 Min (3-Pole) 11.81
(300,0) (300,0)
10.63
(270,0)
5.32
(135,0)
6.40
(162,6) 1.06
12.80 (26,9)
(325,1)
in
Dimensions: (mm)
0613CT0001 181
Class 0613 MasterPact NW Dimensional Drawings
10.63
5.32 (270,0)
(135,0)
6.40 1.06
(162,6) (26,9)
12.80
(325,1)
in
Dimensions: (mm)
in
Dimensions: (mm)
182 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 183
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
184 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 185
Class 0613 MasterPact NW Dimensional Drawings
14.74
(374,3)
4.53
(115) 11.49 2.62 18.02
6.66 (291,8) (66,5) (457,7)
(169,2)
1.75
0.75 (44,5)
(19,1)
13.65
(346,8)
in
Dimensions: (mm)
186 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
0613CT0001 187
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
188 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
0613CT0001 189
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
190 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
0613CT0001 191
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
192 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
in
Dimensions: (mm)
0613CT0001 193
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
194 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
0.98
(25,0)
4.90
6.40 (124,4)
(162,5)
0.43
(11,0)
0.37 7.88
(9,5) (200,1)
20.28
0.37 (515,2)
(9,5)
1.48
(37,6)
1.75
(44,5)
0.31
(7,8)
7.75 6.82 1.98
(196,9) (173,4) (50,4) 2.56
(64,9)
15.12
(384,0)
7.05
(178,9)
5.12 3.56 6.34
(130,0) (90,3) (161,0)
1.75
1.75 (44,5)
(44,5)
0.62
(15,7)
16.18
(411,0)
in
Dimensions: (mm)
0613CT0001 195
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
in
Dimensions: (mm)
196 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
0613CT0001 197
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
198 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
in
Dimensions: (mm)
0613CT0001 199
Class 0613 MasterPact NW Dimensional Drawings
in
Dimensions: (mm)
Figure 135 - Pan Drawings for Three-Pole and Four-Pole Circuit Breakers
15.75
(400)
20.28
(515)
29.33
7.87 (745)
(200) 38.39
35
0. 9) (975)
(
(124)
(124)
4.33
4.33
(162)
(162)
6.38
6.38
0.39)
(
5
in
Dimensions: (mm)
200 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
3.00
1.75
(76)
(44)
(162)
6.39
0.75
(19)
6.85 0.56
(174) (14)
4.92
8.10 (125)
(206) 200
(51)
(102)
4.00
1.75
(162)
(44)
6.39
0.75
(19)
0.56
6.85
(14)
(174)
in
Dimensions: (mm)
0.75
1.75 (19)
(44)
10.35 0.28
(263) (7)
11.60
(295)
in
Dimensions: (mm)
0613CT0001 201
Class 0613 MasterPact NW Dimensional Drawings
2.00
(51)
1.75
(44)
(162)
6.39
0.75
(19)
1.75
(44)
10.35 0.28
(263) (7) 11.60
(295)
in
Dimensions: (mm)
1.77
(50,0)
5.74
(145,8)
7.98
(202,7)
7.57
5.26
(192,3)
(133,6)
in
Dimensions: (mm)
202 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
(162)
6.39
(133)
5.24
(141)
5.55
(200)
(76)
7.89
3
0.51 0.49
(13) (12)
12.24
(311)
in
Dimensions: (mm)
(200)
7.89
0.79
(20) 12.24
3 (311)
(76)
in
Dimensions: (mm)
(175)
6.89
(200)
7.89
(231)
9.11
in
Dimensions: (mm)
0613CT0001 203
Class 0613 MasterPact NW Dimensional Drawings
(117)
(100)
4.63
3.94
(200)
(190)
7.89
7.5
(125)
4.92
0.49
(12) 12.24
(311)
in
Dimensions: (mm)
0.45
(11) 1.18
(30)
(133)
5.24
(200)
7.89
0.79
(20) 12.24
(311)
4.53 4.53
(115) (115)
in
Dimensions: (mm)
204 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
1.97
2.62 (50)
(66) 4.53 4.53 4.53 4.53 4.53
(115) (115) (115) (115) (115)
0.79
(20) 1.97 2.2
(50) 0.98 (56)
1.18 (25)
(30)
(98) (133)
3.86 5.24
(250)
9.84
(240)
9.47
(128)
3
5.04
9.84 1.57
5.94 (76)
(250) (40)
(151)
0.44 13.13
12.81 (333)
(325) (11) 2.36
25.59 13.72 (60)
(650) 0.49 (348)
(12) 0.43
(11)
in
Dimensions: (mm)
0.79
(20,0)
11.05
(280,7)
5.80
(147,3)
0.45
(11,50)
5X 4.53
(115,0) 2.99
0.43 0.51
(76,0)
(11,0) (13,0)
0.49
(12,5)
13.72
(345,5)
in
Dimensions: (mm)
0613CT0001 205
Class 0613 MasterPact NW Dimensional Drawings
0.49
(12,5)
0.49 4.92
(12,5) (125,0)
13.61
(345,7)
6.39 0.98
(162,3) (25,0)
13.72
(348,6)
1.02
(26,0) 4.53
5X
(115,0)
0.79
(20,0)
in
Dimensions: (mm)
4.53 4.53
(115) (115) 0.79 0.45
(20) (11)
2.68
(68) 1.97 0.98
(50) (15)
(133)
5.24
(141)
5.55
(161)
6.34
(76)
3
0.51
(13)
0.49
(12)
9.69
(246)
in
Dimensions: (mm)
206 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
0.45
(133)
5.24
(11)
(161)
6.34
3 0.79
9.69
(76) (20)
(246)
in
Dimensions: (mm)
4.53 4.53
9.92
(243)
9.56
(115) (115)
1.04
(26)
(125)
4.92
(161)
6.34
(232)
9.13
(138)
6.61
0.47
(12)
0.98 0.79
(25) 3 0.50 (20)
(76) (12) 8.62
1.97 (219)
(50)
in
Dimensions: (mm)
3.94
(161)
6.34
(190)
7.5
(125)
4.92
9.69
0.49 (246)
(12)
in
Dimensions: (mm)
0613CT0001 207
Class 0613 MasterPact NW Dimensional Drawings
3.74 5.12
(95) (130) 3.94
0.98 0.98 (100) 3.94
(25) (25) 1.28 (100)
1.97 1.97 (32) 1.28
(50) (50) (32)
2.95 2.98 5.31
(75) 1.28 (75) (135)
(32) 1.18
0.52 0.49 0.49 1.28
(30)
(13) (12) (12) (32)
1.03
(133)
5.24
(26)
(161)
6.34
0.45
(11)
4.53 4.53 0.79
(115) (115) (20) 9.69
(246)
in
Dimensions: (mm)
10.47
(266,0)
1.08
(27,5) 5X 4.53
(115,0)
0.45 0.49
(11,5 (12,5)
0.51 2.99
(13,0) (76,0)
0.98
8.52 (25,0)
(216,4)
3.27
(83,0) 9.98
(253,5)
in
Dimensions: (mm)
208 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
9.98
(253,5)
0.49
(12,5)
0.98 2.99
(25,0) (76,0) 2.37
4.53 0.51 (60,1)
5X
(115,0) (13,0)
0.45
(11,5)
0.79
(20,0)
7.93
(201,4)
2.68
(68,0)
in
Dimensions: (mm)
0613CT0001 209
Class 0613 MasterPact NW Dimensional Drawings
0.79
(20,0) 2.96
(75,1)
5X 4.53
(115,0)
0.45
0.49 (11,5)
(12,5)
0.49
(12,5)
4.92
(125,0)
10.49
(266,4) 0.98
(25,0)
0.67 9.98
(17,0) (253,5)
in
Dimensions: (mm)
210 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
(133)
5.24
(141)
5.55
(161)
6.34
(76)
3
0.51
(13)
0.49
(12)
9.69
(246)
in
Dimensions: (mm)
0.49
(11)
(133)
5.24
(161)
6.34
0.79
3 (20)
(76) 9.69
(246)
in
Dimensions: (mm)
0613CT0001 211
Class 0613 MasterPact NW Dimensional Drawings
(163)
6.44
(110)
4.33
(175)
6.91
(200)
7.89
(236)
9.31
(180)
7.11
0.98 1.5 0.79
(25) (38) 0.50 (20)
3
(12) 11.18
1.97 (96)
(284)
(50)
in
Dimensions: (mm)
(100)
4.63
3.94
(200)
(190)
7.89
7.5
(125)
4.92
0.49
(12) 12.24
(311)
in
Dimensions: (mm)
212 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
9.65 5.12
(245) (130)
2.95
(75)
2.95 1.97
(75) (50) 3.25 7.78
(82) (197)
1.97 0.98
(50) (25) 3.25
0.45 (82)
0.98 3.74
(95) (11)
(25) 0.58 3.94 5.31
0.49 0.49 (15) (100) (135)
(12) (12)
1.18
1.07 (30)
(27)
(133)
5.24
(200)
7.89
1.28 0.79
(32) (20)
4.53 4.53 4.53 12.24
(115) (115) (115) (311)
in
Dimensions: (mm)
049
0.45 (12,5)
(11,5)
0.51
(13,0)
2.99
(76,0)
11.64
(295,7)
0.98
(25,0)
6.39 13.72
(162,3) (348,6)
1.08
7X 4.5 (27,5)
(115,00)
14.21
(361,0)
in
Dimensions: (mm)
0613CT0001 213
Class 0613 MasterPact NW Dimensional Drawings
0.79
(20,0)
11.05
(280,7)
5.80
(147,3)
13.72
(348,5)
in
Dimensions: (mm)
214 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
4.92
(125,0)
13.61
(345,7)
6.39
0.98
(162,3)
(25,0)
13.72
(348,5)
7X 4.53
(115,0)
1.48
0.79
(37,5)
(20,0)
in
Dimensions: (mm)
0613CT0001 215
Class 0613 MasterPact NW Dimensional Drawings
(110)
4.33
(175)
6.89
(133)
5.24
(141)
5.55
(200)
7.89
(76)
3
0.51
(13)
0.49
(12)
12.24
(311)
in
Dimensions: (mm)
1.18
(30)
0.45
(11)
(133)
5.24
(200)
7.89
0.79
(20)
3
(76) 12.24
(311)
in
Dimensions: (mm)
216 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
(252)
(243)
9.91
9.56
(115) (115) (115)
1.02
(26)
(125)
4.92
(161)
6.34
(232)
9.13
(168)
6.61 0.47
(12) 0.79
0.98 (20)
(25) 3 0.50
(12) 8.62
1.97 (76)
(219)
(50)
in
Dimensions: (mm)
(100)
4.63
3.94
(161)
6.34
(190)
7.5
(125)
4.92
0.49 9.69
(12) (246)
in
Dimensions: (mm)
0613CT0001 217
Class 0613 MasterPact NW Dimensional Drawings
(133)
5.24
(161)
6.34
0.45
(11)
0.79
1.28
(20)
(32) 9.69
4.53 4.53 4.53 (246)
(115) (115) (115)
in
Dimensions: (mm)
3.04
1.08 (77,1)
(27,5)
7X 4.53
(115,0)
0.45
(11,5)
0.49
(12,5)
0.51
(13,0) 2.99
(76,0)
8.52
(216,4)
0.98
(25,0)
3.27 9.98
(83,0) (253,5)
in
Dimensions: (mm)
218 0613CT0001
MasterPact NW Dimensional Drawings Class 0613
9.98
(235,5)
0.49
(12,5)
0.51 0.98 2.37
(13,0) (25,0) 2.99 (60,1)
0.45 (76,0)
7X 4.53
(11,5) (115,0)
0.79
(20,0)
7.14
(181,4)
1.89
(48,0)
in
Dimensions: (mm)
0.79 2.96
7X 4.52 (75,1)
(114,9) (20,0)
0.49 0.45
(12,5) (11,5)
0.49
(12,5)
4.92
(125,0)
10.49
(266,4) 0.98
(25,0)
0.67
(17,0) 9.98
(253,5)
in
Dimensions: (mm)
0613CT0001 219
Class 0613 Accessory Dimensional Drawings
ETH1 ETH2
IFE
IFE-XX.YY.ZZ (factory set)
1.77
ETH1 LK/10-100/ACT
2.50
(63,6)
2.83
(72) 2.80
(71)
in
Dimensions: (mm)
24VDC I1 C I2 I3 C I4 I5 C I6
I1 A1
I2
I3 O1
1.77 3.62
I4 O2 (45) (92)
I5
I6
O3
3.34 4.53
(84,8) (115)
IO LV434063
O1 O2 O3 A1
13 14 23 24 33 34 T1 T2
2.50
2.83 (63,6)
(72) 2.80
(71)
in
Dimensions: (mm)
220 0613CT0001
Accessory Dimensional Drawings Class 0613
1.77 3.62
(45) (92)
3.35 4.13
(85) (105)
2.60
0.71 (66)
(18) 2.87
(73)
in
Dimensions: (mm)
3.78
(96) X
3.78
(96)
Y
in
Dimensions: (mm)
3.62+0.03/-0
X (92+0.8/-0) X
0.42 3.62+0.03/-0
(10,6) (92+0.8/-0)
0.81 0.91
(20,7) (23) Y
in
Dimensions: (mm)
0613CT0001 221
Class 0613 Accessory Dimensional Drawings
0.89
2Ø
(22,5)
0.65
(16,5)
3.91
(99,3)
X
1.26+/-0.02
X (32+/-0.5)
0.75
(19)
in
Dimensions: (mm)
5.08
(129) X
6.42
(163)
Y
in
Dimensions: (mm)
222 0613CT0001
Accessory Dimensional Drawings Class 0613
0.06–0.24
(1.5–6)
3.94
X (100)
1.20
(30.6)
0.69
(17.5)
1.54
(39)
+0/-0.01
Ø 0.89+0/-0,30
(22,4 )
3.94
(100)
3.94 3.94
(100) (100) X
3.94
(100)
1.18+0/-0.008
(30+0/-0,20)
in
Dimensions: (mm)
0613CT0001 223
Class 0613 Accessory Dimensional Drawings
K Ethernet
J
24 V DC
Modbus
A
A A A
A
24 V DC
24 V DC EB
+24V
0V
II KK II II
Eth2
C
C Eth1
C
C +24V
0V
D
D
KK +24V
0V
Eth1
Eth2
Eth2
Eth1
II
II
II I5
C
I6
I4
C
I3
I2
C
I1
I6
C
I5
I4
C
I3
I2
C
I1
+
24VDC
A1
K
K
K O1
O2
O3
K
K dule
IO Mo
E
I6
E
C
I5
I4
C
I3
I2
C A1
I1
T2
O3 T1
34
I6 I6 O2 33
C C 24
I5 23
O1
I3 14
I2 13
C I2
C
I1 I1
+
24VDC
I6
C
I5
I3
I2
C
I1
+
24VDC
dule
IO Mo
A1
T2
T1
O2
24
O1 23
14
13
A1
T2
T1
M
O2
M
24
O1 23
14
13
F
F
LL L
L LL M
M
FF G
G H H
H
H
ULP termination
A FDM121 (TRV00121) E IO module (LV434063) I M NSX cord
(TRV00880)
224 0613CT0001
Accessory Dimensional Drawings Class 0613
Figure 181 - Fixed MasterPact NT and NW Connection to the Communication Interface Module
1 21
FDM
Color
Red E1 24 V
Black E2 0V
White E5 H
Blue E6 L
Breaker ULP
cord
E1 E2 E3 E4 E5 E6
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
Customer terminal block
D0 = A’ / Rx-, A / Tx-
ULP cable D1 = B’ / Rx+, B / Tx+
24VDC
ETH1 ETH2
IFE IFM
OR
0613CT0001 225
Class 0613 Accessory Dimensional Drawings
Figure 182 - Drawout MasterPact NT and NW Connection to the IO and Communication Interface Module
1 21
FDM
24VDC
IO
application
Color module
Red E1 24 V
Black E2 0V
White E5 H
Blue E6 L
Breaker ULP ULP cable
cord
Red Black White Blue
E1 E2 E3 E4 E5 E6
24 V
0V
A / Tx- D0
B / Tx+ D1
A’ / Rx- D0
B’ / Rx+ D1
Customer terminal block
Modbus-SL Ethernet
24 V DC 24 V DC
24VDC
ETH1 ETH2
IFM IFE
226 0613CT0001
Selection Class 0613
Selection
Introduction
MasterPact circuit breakers are available in three frame sizes:
• T-frame circuit breakers: rated up to 800 A (ANSI Certified), up to 1600 A
(UL® Listed), and up to 1600 A (IEC Rated).
• W-frame circuit breakers: rated up to 4000 A (ANSI Certified), up to 3000 A
(UL Listed), and up to 4000 A (IEC Rated).
• Y-frame circuit breakers: rated up to 5000 A (ANSI Certified), up to 6000 A
(UL Listed), and up to 6300 A (IEC Rated).
Within each range, several sensor plugs are available to determine the maximum
trip rating of each circuit breaker. In addition to a sensor plug, an adjustable rating
plug is available to get lower ampacity than that available with the sensor plug.
MasterPact circuit breakers can be equipped with a variety of MicroLogic
electronic trip unit configurations, ranging from basic circuit protection to more
advanced relay protection and power metering capabilities. Additionally all
electronic trip units within the new MicroLogic family are field interchangeable and
upgradeable. Each control unit is also equipped with an interchangeable and
upgradeable adjustable rating plug which is used to select the long-time pickup
setting of the circuit breaker.
NOTE: MasterPact circuit breakers are ordered by sensor plug rating, not
ampere trip rating. The trip rating of the circuit breaker is determined by the
setting of the adjustable rating plug. Sensor plugs and rating plugs are field
replaceable.
0613CT0001 227
Class 0613 Selection
Model Number NT NW NW
Frame type T W Y (wide-construction)
254 V 240 V 240 V 240 V 254 V 254 V 240 V 240 V 254 V 240 V 240 V
42 kA 200 kA 200 kA 150 kA 200 kA 100 kA 200 kA 150 kA 200 kA 200 kA 150 kA
AC rating 508 V 480 V 480 V 440 V 508 V 508 V 480 V 440 V 508 V 480 V 440 V
42 kA 100 kA 100 kA 130 kA 200 kA 100 kA 150 kA 150 kA 200 kA 150 kA 150 kA
635 V 600 V 600 V 690 V 635 V 635 V 600 V 690 V 635 V 600 V 690 V
N/A 50 kA 50 kA 42 kA 130 kA 85 kA 100 kA 100 kA 130 kA 100 kA 100 kA
Construction
Drawout X X — X X — X X X X X
Fixed (UL Listed and IEC
Rated only) X X X X X X X X X X X
Termination
Rotatable rear terminals X X X X X X X X X X X
Front-connected terminals X X X X X X X X X X X
Accessories Available for the Circuit Breaker and Cradle
• Shunt close • Ready-to-close contact • Door interlock
• Shunt trip • Overcurrent trip switch (standard) • Operations counter
• Undervoltage trip • Rack in interlock • Safety Shutter
• Fixed time delay • Key locks for circuit breaker and cradle • Cradle rejection kit (standard)
• Adjustable time delay • Padlock attachment (circuit breaker plus cradle) • Rail Padlocking
• Spring-charging motor • Mechanical interlocks
• Auxiliary contacts (standard) • Cradle position switches
LSI 5
LS0 (IEC Rated) 2.0A
228 0613CT0001
Selection Class 0613
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
254 V 508 V 635 V
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 480 V 600 V
NOTE: L1F and LF circuit breakers are tested to show the arc flash hazard
risk category as referenced by NFPA 70E.
0613CT0001 229
Class 0613 Selection
NT08NA 42 kA 42 kA NA 42 kA
800 A
NT08HA 42 kA 42 kA 22 kA 42 kA
Withstand Rating43
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
NT08HF 65 kA 50 kA 50 kA 40 kA
800 A
NT08HB44 200 kA 100 kA N/A 10 kA
NT12HF 65 kA 50 kA 50 kA 40 kA
1200 A
NT12HB44 200 kA 100 kA N/A 10 kA
NT16HF 65 kA 50 kA 50 kA 40 kA
1600 A45
NT16HB44 200 kA 100 kA N/A 10 kA
800 A NT08HA 42 kA 42 kA 42 kA — 42 kA
1000 A NT10HA 42 kA 42 kA 42 kA — 42 kA
1250 A NT12HA 42 kA 42 kA 42 kA — 42 kA
1600 A NT16HA 42 kA 42 kA 42 kA — 42 kA
42. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
43. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
44. Not available in four-pole circuit breakers.
45. Fixed-mount only. 1600A UL489 drawout switches are not available.
46. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
230 0613CT0001
Selection Class 0613
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
254 V 508 V 635 V
NOTE: L1F circuit breakers are tested to show the arc flash hazard risk
category as referenced by NFPA 70E.
0613CT0001 231
Class 0613 Selection
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 480 V 600 V
NOTE: LF circuit breakers are tested to show the arc flash hazard risk
category as referenced by NFPA 70E.
232 0613CT0001
Selection Class 0613
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 440 V 690 V 1150 V
0613CT0001 233
Class 0613 Selection
Withstand Rating52
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
800 A NW08HF 100 kA 100 kA 85 kA 40 kA
1200 A NW12HF 100 kA 100 kA 85 kA 40 kA
1600 A NW16HF 100 kA 100 kA 85 kA 40 kA
2000 A NW20HF 100 kA 100 kA 85 kA 40 kA
2500 A NW25HF 100 kA 100 kA 85 kA 65 kA
3000 A NW30HF 100 kA 100 kA 85 kA 65 kA
50. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
51. Not available in 4P.
52. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
234 0613CT0001
Selection Class 0613
Withstand Rating53
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
NW08HF 100 kA 100 kA 85 kA 40 kA
800 A
NW08HB54 200 kA 150 kA 100 kA 35 kA
NW12HF 100 kA 100 kA 85 kA 40 kA
1200 A
NW12HB54 200 kA 150 kA 100 kA 35 kA
NW16HF 100 kA 100 kA 85 kA 40 kA
1600 A
NW16HB54 200 kA 150 kA 100 kA 35 kA
NW20HF 100 kA 100 kA 85 kA 40 kA
2000 A
NW20HB54 200 kA 150 kA 100 kA 35 kA
NW25HF 100 kA 100 kA 85 kA 65 kA
2500 A
NW25HB54 200 kA 150 kA 100 kA 65 kA
NW30HF 100 kA 100 kA 85 kA 65 kA
3000 A
NW30HB54 200 kA 150 kA 100 kA 65 kA
Withstand Rating53
Frame Rating Instantaneous
Model Number
Override
240 V 440 V 690 V
800 A NW08HF 85 kA 85 kA 85 kA 85 kA
1000 A NW10HF 85 kA 85 kA 85 kA 85 kA
1250 A NW12HF 85 kA 85 kA 85 kA 85 kA
1600 A NW16HF 85 kA 85 kA 85 kA 85 kA
2000 A NW20HF 85 kA 85 kA 85 kA 85 kA
2500 A NW25HF 85 kA 85 kA 85 kA 85 kA
3200 A NW32HF 85 kA 85 kA 85 kA 85 kA
4000 A NW40HF 85 kA 85 kA 85 kA 85 kA
53. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
54. Not available in 4P.
55. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
56. Not available for fixed-mounted circuit breakers.
0613CT0001 235
Class 0613 Selection
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 480 V 600 V
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 440 V 690 V
57. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
58. Not available for fixed-mounted circuit breakers.
59. Not available for fixed-mounted or four-pole drawout circuit breakers.
236 0613CT0001
Selection Class 0613
Interrupting Rating
Frame Rating Model Number Sensor Plug Rating
240 V 440 V 690 V
Withstand Rating63
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
4000 A NW40HF 100 kA 100 kA 85 kA 75 kA
5000 A NW50HF 100 kA 100 kA 85 kA 75 kA
6000 A NW60HF 100 kA 100 kA 85 kA 75 kA
Withstand Rating63
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
4000 A NW40HF 100 kA 100 kA 85 kA 75 kA
NW40HB62 1200 kA 150 kA 100 kA 75 kA
5000 A NW50HF 100 kA 100 kA 85 kA 75 kA
60. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
61. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
62. Not available in 4P.
63. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
0613CT0001 237
Class 0613 Selection
Withstand Rating64
Frame Rating Instantaneous
Model Number
Override
240 V 480 V 600 V
NW50HB65 200 kA 150 kA 100 kA 75 kA
6000 A NW60HF 100 kA 100 kA 85 kA 75 kA
NW60HB65 200 kA 150 kA 100 kA 75 kA
64. The withstand rating is the fault current (at rated voltage) that the switch will withstand without damage when protected by a circuit
breaker with an equal continuous current rating.
65. Not available in 4P.
66. When used in conjunction with an overcurrent relay, circuit breaker, or fuse.
238 0613CT0001
Trip Curves Class 0613
Trip Curves
MicroLogic 6.0 A/P/H Trip Units
Figure 183 - MicroLogic 6.0 A/P/H Trip Units: In ≤ 400 A MicroLogic 6.0 A/P/H Trip Units
with Adjustable Ground-Fault
MULTIPLES OF SENSOR RATING (In) Pickup and Delay
Characteristic Trip Curve No. 613-1
.05
.06
.07
.08
.09
.15
1.5
10
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000
Ground Fault I2t OFF and ON
7000
6000
7000
6000
In ≤ 400 A
5000 5000
4000 4000
1500 1500
Curves apply from -25°C to +70°C
1000 1000 (-13°F to +158°F) ambient temperature.
900 900
800 800
700 700
600 600
500 500
400 400
300 300
200 200
GROUND-FAULT
150 PICKUP 150
x In
100 100
90 90
80 80
70 70
60 60
50 50
40 40
30 30
15 15
10 0.4 10
9 9
8 8
7 7
6 6
TIME IN SECONDS
5 5
4 4
0.6 0.8 1.0
3 3
2 2
1.5 1.5
DELAY
SECONDS AT 1 x In
1 1
.9
0.1 .9
0.2
0.4
.8 .8
.7 0.3 .7
ON
0.4
0.3
.6 .6
ON
.5 .5
0.2
.4 .4
DELAY BANDS
I2t ON
0.1
.3 .3
O
0.3 OFF
N
MAXIMUM
.2 .2
UNRESTRAINED
GROUND-FAULT 0.2 OFF
.15 DELAY .15
.1 0.1 OFF .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
GROUND-FAULT
.04 DELAY BANDS .04
I2t OFF
.03
(FIXED DELAY) .03
0
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
.1
.15
.2
.3
.4
.5
.6
.7
.8
.9
1
.05
.06
.07
.08
.09
1.5
6
7
8
9
10
0613CT0001 239
Class 0613 Trip Curves
Figure 184 - MicroLogic 6.0 A/P/H Trip Units: MicroLogic 6.0 A/P/H Trip Units
400 A < In ≤ 1200 A with Adjustable Ground-Fault
Pickup and Delay
MULTIPLES OF SENSOR RATING (In) Characteristic Trip Curve No. 613-2
Ground Fault I2t OFF and ON
.05
.06
.07
.08
.09
.15
1.5
10
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000 400 A < In ≤ 1200 A
7000 7000
6000 6000
5000 5000
4000 4000
The time-current curve information is to be used
3000 3000
for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800 800
700 700
600 600
500 500
400 400
300 300
200 200
150 150
100 100
90 90
80
GROUND-FAULT 80
70
PICKUP 70
x In
60 60
50 50
40 40
30
0.2 0.3 0.5 0.7 0.9 30
20 20
15 15
10 10
9 9
8 8
7 7
6
0.4 0.6 0.8 1.0 6
TIME IN SECONDS
5 5
0.4
4 4
ON
3 3
0.2
2 2
ON
1.5 1.5
DELAY
SECONDS AT 1 x In
1 1
.9 0.1 .9
.8 0.2 .8
.7 0.3 .7
0.4
.6 .6
.5 .5
0.3
DELAY BANDS
I2t ON
.3 .3
0.1
0.3 OFF
ON
MAXIMUM
.2 .2
UNRESTRAINED
GROUND-FAULT 0.2 OFF
.15 DELAY .15
.1 0.1 OFF .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
GROUND-FAULT
.04 DELAY BANDS .04
I2t OFF
.03 (FIXED DELAY) .03
0
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
.1
.15
.2
.3
.4
.5
.6
.7
.8
.9
1
.05
.06
.07
.08
.09
1.5
6
7
8
9
10
240 0613CT0001
Trip Curves Class 0613
Figure 185 - MicroLogic 6.0 A/P/H Trip Units: MicroLogic 6.0 A/P/H Trip Units
In > 1200 A with Adjustable Ground-Fault
Pickup and Delay
AMPERES x 103 Characteristic Trip Curve No. 613-3
Ground Fault I2t OFF and ON
.05
.06
.07
.08
.09
.15
1.5
10
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000 In > 1200 A
7000 7000
6000 6000
5000 5000
4000 4000
The time-current curve information is to be used
3000 3000
for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800 800
700 700
600 600
500 500
400 400
300 300
200 200
150
GROUND-FAULT 150
PICKUP
1120 A
800 A
x In
100 100
90 90
80 80
70 70
960 A
60 60
50 50
640 A
40 40
30 30
20 20
880 A
15 15
10 10
9 9
8 8
7 7
1040 A
6 6
TIME IN SECONDS
5 5
720 A
4 4
3 3
2 2
1200 A
1.5 1.5
500 A
DELAY
SECONDS AT 1 x In
1 1
.9
0.1 .9
0.4
.8
0.2 .8
0.3
ON
.7 .7
0.2
0.4
.6 .6
ON
.5 .5
0.3
.4 .4
DELAY BANDS
I2t ON
.3 .3
0.1
0.3 OFF
ON
MAXIMUM
.2 .2
UNRESTRAINED
GROUND-FAULT 0.2 OFF
.15 DELAY .15
.1 0.1 OFF .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
GROUND-FAULT
.04 DELAY BANDS .04
I2t OFF
.03 (FIXED DELAY) .03
0
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
.1
.15
.2
.3
.4
.5
.6
.7
.8
.9
1
.05
.06
.07
.08
.09
1.5
6
7
8
9
10
AMPERES x 103
0613CT0001 241
Class 0613 Trip Curves
Figure 186 - MicroLogic 5.0/6.0 A/P/H Trip Units: Long-Time Pickup and Delay, Short-Time Pickup, and
I2t OFF Delay
MicroLogic 5.0/6.0 A/P/H Trip Units
CURRENT IN MULTIPLES OF Ir (Ir = LONG-TIME SETTING x In) Characteristic Trip Curve No. 613-4
Long-Time Pickup and Delay
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000
Short-Time Pickup and I2t OFF Delay
7000 7000
6000 6000
5000 5000
4000
LONG-TIME PICKUP
4000
The time-current curve information is to be used
x In = Ir
3000 3000
for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800
700
800
700 NOTE:
600
500
24
600
500
1. There is a thermal-imaging effect that can
400
16
400
act to shorten the long-time delay. The
300 300
thermal-imaging effect comes into play if a
current above the long-time delay pickup
200 200
value exists for a time and then is cleared by
150 150 the tripping of a downstream device or the
100 100
circuit breaker itself. A subsequent overload
90
80
90
80
will cause the circuit breaker to trip in a
20
70
60 12
70
60
shorter time than normal. The amount of
50 8 50 time delay reduction is inverse to the
40 4 40
amount of time that has elapsed since the
2
30 30 previous overload. Approximately twenty
1
20
.5
20
minutes is required between overloads to
15
24
15
completely reset thermal-imaging.
16
2. The end of the curve is determined by the
10 10
9
8
LONG-TIME
9
8
interrupting rating of the circuit breaker.
7
DELAY BANDS 7
SECONDS AT 6 x Ir
6 6 3. With zone-selective interlocking ON, short-
TIME IN SECONDS
4
5
4
time delay utilized, and no restraining signal,
the maximum unrestrained short-time delay
3 3
time band applies regardless of the setting.
2 2
4. Total clearing times shown include the
1.5 1.5
response times of the trip unit, the circuit
8
1 1 breaker opening, and the extinction of the
.9 SHORT-TIME 10 SHORT-TIME .9
.8 PICKUP
x Ir 1.5 2 2.5
6 DELAY I2t OFF
(FIXED-TIME DELAY)
.8 current.
.7 .7
SECONDS AT 10 x Ir
.6
.5
4 .6
.5
5. For a withstand circuit breaker,
.4
3 5 0.4 OFF .4 instantaneous can be turned OFF. See trip
.3 .3
curve 613-7 for instantaneous trip curve.
MAXIMUM
0.3 OFF
See trip curve 613-10 for instantaneous
.2
UNRESTRAINED
SHORT-TIME
.2
override values.
0.2 OFF
.15 DELAY .15
.05 .05
.04 .04
.03 .03
0
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
CURRENT IN MULTIPLES OF Ir
(Ir = LONG-TIME SETTING x In)
242 0613CT0001
Trip Curves Class 0613
Figure 187 - MicroLogic 5.0/6.0 A/P/H Trip Units: Short-Time Pickup and I2t ON Delay
MicroLogic 5.0/6.0 A/P/H Trip Units
CURRENT IN MULTIPLES OF Ir (Ir = LONG-TIME SETTING x In) Characteristic Trip Curve No. 613-5
Short-Time Pickup and I2t ON Delay
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000 9000
8000 8000
7000 7000
6000 6000
5000 5000
The time-current curve information is to be used
4000 4000
for application and coordination purposes only.
3000 3000
2000 2000
Curves apply from -25°C to +70°C
1500 1500
(-13°F to +158°F) ambient temperature.
1000
900
1000
900
NOTE:
800
700
800
700 1. There is a thermal-imaging effect that can
600
500
600
500
act to shorten the long-time delay. The
400 400
thermal-imaging effect comes into play if a
300 300
current above the long-time delay pickup
value exists for a time and then is cleared by
200 200
the tripping of a downstream device or the
150 150 circuit breaker itself. A subsequent overload
SHORT-TIME will cause the circuit breaker to trip in a
100 PICKUP 100
90
80
x Ir 90
80
shorter time than normal. The amount of
1.5 2 2.5 6 8 10
70
60
70
60
time delay reduction is inverse to the
50 50 amount of time that has elapsed since the
40
3 4 5
40
previous overload. Approximately twenty
30 30 minutes is required between overloads to
20 20
completely reset thermal-imaging.
15 15 2. The end of the curve is determined by the
interrupting rating of the circuit breaker.
10 10
9 9
8
7
8
7
3. With zone-selective interlocking ON, short-
6 6 time delay utilized, and no restraining signal,
TIME IN SECONDS
0.4
5 5
the maximum unrestrained short-time delay
O
N
4 4
time band applies regardless of the setting.
3 3
0.2
2 2
response times of the trip unit, the circuit
0.1
1.5 1.5
breaker opening, and the extinction of
0.3
ON
current.
ON
1 1
.9 .9
.8 .8
.7 .7 5. For withstand circuit breaker, instantaneous
.6
.5
.6
.5
can be turned OFF. See trip curve 613-7 for
.4 0.4 ON .4 instantaneous trip curve. See trip curve 613-
SHORT-TIME
.3
DELAY I2t ON .3
10 for instantaneous override values.
SECONDS AT 10 x Ir 0.3 ON
.2
MAXIMUM
.2
6. See trip curve 613-4 for long-time pickup
UNRESTRAINED
.15
SHORT-TIME 0.2 ON
.15
and delay trip curve.
DELAY
.1 0.1 ON .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
CURRENT IN MULTIPLES OF Ir
(Ir = LONG-TIME SETTING x In)
0613CT0001 243
Class 0613 Trip Curves
Figure 188 - MicroLogic 5.0/6.0 Trip Units: Instantaneous Pickup, 2x to 15x and OFF
MicroLogic 5.0/6.0 A/P/H Trip Units
MULTIPLES OF SENSOR RATING (In) Characteristic Trip Curve No. 613-7
Instantaneous Pickup
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000 2x–15x and OFF
7000 7000
6000 6000
5000 5000
4000 4000
The time-current curve information is to be used
3000 3000 for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800
700
800
700
NOTE:
600 600
1. The end of the curve is determined by the
500 500
400 400
interrupting rating of the circuit breaker.
300 300 2. Total clearing times shown include the
response times of the trip unit, the circuit
200 200
breaker opening, and the extinction of
150 150
current.
INSTANTANEOUS
100
90
80
PICKUP
x In
100
90
80
3. The instantaneous region of the trip curve
70 70 shows maximum total clearing times. Actual
60 60
50 50
clearing times in this region can vary
40 40 depending on the circuit breaker
30 30 mechanism design and other factors. The
10 x
actual clearing time can be considerably
20 20
faster than indicated. Contact your local
15 15
Sales Office for additional information.
10
9
10
9 4. For withstand circuit breaker, instantaneous
8 8
7 7 can be turned OFF. See trip curve 613-10
6 6
for instantaneous override values.
TIME IN SECONDS
5 5
4 4
5. See trip curve 613-4 and 613-5 for long-time
3 3
pickup, long-time delay, short-time pickup,
2 2
and short-time delay trip curve.
1.5 1.5
1 1
.9 .9
.8 .8
.7 .7
.6 .6
.5 .5
.4 .4
.3 .3
.2 .2
.15 .15
2x 3x 4x 6x 8x 12 x 15 x
.1 .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
244 0613CT0001
Trip Curves Class 0613
Figure 189 - MicroLogic 3.0A Trip Unit: Long-Time Pickup and Delay
MicroLogic 3.0 Trip Unit
CURRENT IN MULTIPLES OF Ir (Ir = LONG-TIME SETTING x In) Characteristic Trip Curve No. 613-6
Long-Time Pickup and Delay
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000 9000
8000 8000
7000 7000
6000 6000
2000 2000
Curves apply from -30°C to +60°C
1500 1500
(-22°F to +140°F) ambient temperature.
1000
900
1000
900
NOTE:
800
700
800
700 1. There is a thermal-imaging effect that can
600
500
600
500
act to shorten the long-time delay. The
400 400
thermal-imaging effect comes into play if a
300
24 300
current above the long-time delay pickup
16 value exists for a time and then is cleared
200 200
by the tripping of a downstream device or
150 150 the circuit breaker itself. A subsequent
100 100
overload will cause the circuit breaker to trip
90
80
90
80
in a shorter time than normal. The amount
70
60
70
60
of time delay reduction is inverse to the
50 50 amount of time that has elapsed since the
LONG-TIME DELAY
40
SECONDS AT 6 x Ir
40
previous overload. Approximately twenty
30
20
30 minutes is required between overloads to
20
12
20
completely reset thermal-imaging.
8
15 4 15 2. The end of the curve is determined by the
2
1
24 instantaneous setting of the circuit breaker.
10 10
9 .5 16 9
8
7
8
7
3. Total clearing times shown include the
6 6 response times of the trip unit, the circuit
TIME IN SECONDS
4
5
4
breaker opening, and the extinction of
current.
3 3
1 1
.9 .9
.8 .8
.7 .7
.6 .6
.5 .5
.4 .4
.3 .3
.2 .2
.15 .15
.1 .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
CURRENT IN MULTIPLES OF Ir
(Ir = LONG-TIME SETTING x In)
0613CT0001 245
Class 0613 Trip Curves
Figure 190 - MicroLogic 3.0A Trip Unit: Instantaneous Pickup, 1.5X to 12X
MicroLogic 3.0 Trip Units
MULTIPLES OF SENSOR RATING (In) Characteristic Trip Curve No. 613-8
Instantaneous Pickup
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000
1.5x–12x
7000 7000
6000 6000
5000 5000
4000 4000
The time-current curve information is to be used
3000 3000 for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800
700
800
700
Instantaneous override values are given on 613-
600 600
10.
500 500
400 400
300 300
NOTE:
1. The end of the curve is determined by the
200 200 interrupting rating of the circuit breaker.
150 150
2. Total clearing times shown include the
100
INSTANTANEOUS
PICKUP
100 response times of the trip unit, the circuit
90 90
80
70
x In 80
70
breaker opening, and the extinction of
60 60 current.
50 50
5 5
1.5 1.5
1 1
.9 .9
.8 .8
.7 .7
.6 .6
.5 .5
.4 .4
.3 .3
.2 .2
.1 .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
246 0613CT0001
Trip Curves Class 0613
100
1.5
10
15
20
30
40
50
60
70
80
90
.5
.6
.7
.8
.9
1
6
7
8
9
10000 10000
9000
8000
9000
8000
Short-Time Pickup with No Delay
7000 7000
6000 6000
5000 5000
4000
LONG-TIME PICKUP
4000
The time-current curve information is to be used
x In = Ir
3000 3000
for application and coordination purposes only.
2000 2000
1500 1500
Curves apply from -25°C to +70°C
(-13°F to +158°F) ambient temperature.
1000 1000
900 900
800
700
800
700 NOTE:
600
500
24
600
500
1. There is a thermal-imaging effect that can
400
16
400 act to shorten the long-time delay. The
300 300
thermal-imaging effect comes into play if a
current above the long-time delay pickup
200 200
value exists for a time and then is cleared
150 150 by the tripping of a downstream device or
100 100
the circuit breaker itself. A subsequent
90
80
90
80
overload will cause the circuit breaker to trip
20
70
60 12
70
60
in a shorter time than normal. The amount
50 8 50 of time delay reduction is inverse to the
40 4 40
amount of time that has elapsed since the
2
30
1
30
previous overload. Approximately twenty
20
.5
20
minutes is required between overloads to
15
24
15
completely reset thermal-imaging.
10
16
10
2. The end of the curve is determined by the
9
8
LONG-TIME
9
8
short-time setting.
7
DELAY BANDS 7
SECONDS AT 6 x Ir
6 6 3. Total clearing times shown include the
TIME IN SECONDS
5 5
4 4
response times of the trip unit, the circuit
3 3
breaker opening, and the extinction of
current.
2 2
4. Overload indicator illuminates at 100%.
1.5 1.5
8
1 1
.9 SHORT-TIME 10 .9
.8 PICKUP 6 .8
.7 x Ir 1.5 2 2.5 .7
.6 .6
4
.5 .5
.4 3 5 .4
.3 .3
.2 .2
.15 .15
.1 .1
.09 .09
.08 .08
.07 .07
.06 .06
.05 .05
.04 .04
.03 .03
.02 .02
1 CYCLE
.015 .015
.01 .01
.009 .009
1
.008 2 CYCLE .008
.007 .007
.006 .006
.005 .005
1
1.5
6
7
8
9
10
.5
.6
.7
.8
.9
15
20
30
40
50
60
70
80
90
100
CURRENT IN MULTIPLES OF Ir
(Ir = LONG-TIME SETTING x In)
0613CT0001 247
Class 0613 Trip Curves
248 0613CT0001
Trip Curves Class 0613
.5
USER DEFINED RANGE: AUTOMATIC RANGE:
FAULT LEVEL MUST NO USER CONFIGURABLE SETTINGS
.4 TRIP BREAKER IN
INSTANTANEOUS MODE
.3 (1.2X PICKUP)
.2
.15
TIME IN SECONDS
.1
.09
.08
.07
.06
.05
.04
.03
.02
.015
.01
.009
.008
.007
.006
.005
1
7
8
9
10
15
20
30
40
50
60
70
80
90
100
150
200
300
400
500
600
700
800
900
1000
2 In - NW08 FAULT CURRENT (KA)
0613CT0001 249
Class 0613 Trip Curves
Figure 193 - MasterPact NT Low Arc Flash Circuit Breaker: L1F and LF
.2
.15
TIME IN SECONDS
.1
.09
.08
.07
.06
.05
.04
.03
.02
.015
.01
.009
.008
.007
.006
.005
1
6
7
8
9
10
15
20
30
40
50
60
70
80
90
100
150
200
300
400
500
600
700
800
900
1000
2 In - NT08 FAULT CURRENT (KA)
250 0613CT0001
Schneider Electric
800 Federal Street
Andover, MA 01810
USA
888–778–2733
www.se.com