NOTES:-

1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE


IN METERS UNLESS MENTIONED OTHERWISE.
2. DIMENSION ARE NOT TO BE SCALED ,ONLY
WRITTEN DIMENSION SHALL BE FOLLOWED.
3. THE GRADE OF CONCRETE SHALL BE M-25.
4. ALL REINFORCING BARS SHALL BE H.Y.S.D.
A B BARS HAVING SPECIFIED MINIMUM GRADE OF
0.2% PROOF STRESS OF 500 MPA
CONFORMING TO IS: 1786.
A B
5. DISCREPANCY IF ANY IS TO BE IMMEDIATELY
BROUGHT IN TO NOTICE OF ENGINEER FOR
NECESSARY MODIFICATION IN THE DRAWING.
6. LAPS MAY BE PROVIDED IN REINFORCEMENT
1 1
BARS WHEREVER REQUIRED. LAPS SHALL BE
STAGGERED BY ATLEAST A LAP LENGTH AND
NOT MORE THAN 50% BARS SHALL BE LAPPED
AT A SECTION. A MINIMUM LAP LENGTH OF 45
TIMES DIA. OF BAR SHALL BE PROVIDED.
7. MINIMUM CLEAR COVER TO REINFORCEMENT
SHALL BE :
BEAM................30MM.
SLAB................20MM.
MINI NEST 8. BEAMS AND COLUMNS TO BE CASTED
3000X3000 INTEGRALLY WITH WALLS.
TPY.PLAN OF FOOTING

2 2

COLUMN SCHEDULE

TO TERRACE LVL.
A B 230

FROM FDN LVL.

230
M-25
A B
4-12
1 1

CONCRETE
TYPICAL C1

MIX
ZONE-A

ZONE-B

2 2

CLIENT : INDEPENDENT ENGINEER : CONCESSIONAIRE : JOB No. : PROJECT:

24.03.2023

L.N.MALVIYA INFRA AMRAVATI-CHIKHLI PKG-1


TITLE :
PROJECT PVT.LTD
ARCH. PLAN, COLUMN - FOUNDATION, PLINTH
NATIONAL HIGHWAYS
&TERRACE BEAM PLAN OF MINI NEST 01OF02
AUTHORITY OF INDIA
NTS DRAWING NO : NEC-VJBYP4-DD-P038-STR-MN01 R2
NOTES:-
1. ALL DIMENSIONS ARE IN MM AND LEVELS ARE
IN METERS UNLESS MENTIONED OTHERWISE.
2. DIMENSION ARE NOT TO BE SCALED ,ONLY
WRITTEN DIMENSION SHALL BE FOLLOWED.
3. THE GRADE OF CONCRETE SHALL BE M-25.
4. ALL REINFORCING BARS SHALL BE H.Y.S.D.
BARS HAVING SPECIFIED MINIMUM GRADE OF
0.2% PROOF STRESS OF 500 MPA
CONFORMING TO IS: 1786.
5. DISCREPANCY IF ANY IS TO BE IMMEDIATELY
BROUGHT IN TO NOTICE OF ENGINEER FOR
NECESSARY MODIFICATION IN THE DRAWING.
6. LAPS MAY BE PROVIDED IN REINFORCEMENT
BARS WHEREVER REQUIRED. LAPS SHALL BE
STAGGERED BY ATLEAST A LAP LENGTH AND
NOT MORE THAN 50% BARS SHALL BE LAPPED
AT A SECTION. A MINIMUM LAP LENGTH OF 45
TIMES DIA. OF BAR SHALL BE PROVIDED.
7. MINIMUM CLEAR COVER TO REINFORCEMENT
SHALL BE :
BEAM................30MM.
SLAB................20MM.
8. BEAMS AND COLUMNS TO BE CASTED
INTEGRALLY WITH WALLS.

A B 0.2L 0.2L

REINF. AS/PER DETAIL

0.15L REINF. AS/PER DETAIL 0.15L


L
1

(DISTRIBUTION BAR SHALL BE PROVIDED AT 300 C/C)

LEGEND: SLAB REINFORCEMENT:

2 LEGEND:

CLIENT : INDEPENDENT ENGINEER : CONCESSIONAIRE : JOB No. : PROJECT:

24.03.2023

L.N.MALVIYA INFRA
TITLE :
PROJECT PVT.LTD AMRAVATI-CHIKHLI PKG-1
NATIONAL HIGHWAYS PLINTH BEAM & SLAB REINFORCEMENT OF MINI NEST 02 F 02