WHRS system

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 4

WHRS System

SUMMARY

S.No Location Parameter Unit

m3/hr
Flow rate kg/hr
Nm3/hr
Pre Heater Fan Specific flow rate Nm3/kg clinker
Inlet
1 Temperature Deg c
(Assumed)
Specific Heat Kcal/kg deg c
Heat avaialble Mkcal
Pre Heater Temperature Deg c
String Outlet Static Pressure mmWg
m3/hr
Flow rate kg/hr
Nm3/hr
Specific flow rate Nm3/kg clinker
2 Tertiary Air Duc
Temperature Deg c
(Assumed)
Specific Heat Kcal/kg deg c
Heat avaialble Mkcal
m3/hr
Flow Rate kg/hr
Cooler Vent Nm3/hr
(With water
spray) Specific flow rate Nm3/kg clinker
Temperature Deg c

3 Specific Heat Kcal/kg deg c


Heat avaialble Mkcal
m3/hr
Water Spray Quantity
Cooler Vent Nm3/hr
Without water
spray
Cooler Vent
Without water
spray Flow Rate at Cooler
Vent after removing Nm3/hr
water quantity
Calculated cooler vent
temp Deg c
stem

DATE: 13.04.2018

Present After After After


Operating at Upgradation Upgradation Upgradation
5300-5400 tpd at 6000 tpd at 6200 tpd at 6500 tpd

485158 836295 871646 925537


292537 292537 292537 292537
211984 211984 211984 211984
1.47 1.47 1.47 1.47

258 265 267 270

0.242 0.243 0.243 0.243


18.29 18.81 18.96 19.19
264.00 270.00 272.00 275.00
-495 -595 -620 -660
315919 354471 504190 528606
92162 92162 92162 92162
315919 71278 71278 71278
0.52 0.29 0.28 0.26

900 1018 1020 1025

0.258 0.260 0.260 0.261


21.38 24.43 24.48 24.62
209528
139083
107566
0.78
300
0.244
10.18
16.5
20625
86941 230750 238442 249980

440 420 430 440

You might also like