JAD-ACC-ADT-100 ACCOMMODATION BUILDING EXISTING AND PROPOSED FLOOR-JAD-ACC-ADT-100

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

AUTHORITY STAMP

SCHEDULE OF DOORS

LEGENDS
F.F.L
PROPOSED WALL UNIT CABINET
KEY PLAN
DOOR NO. DOOR SIZE 1000x2200 (STRUCTURAL OPENING) 1223

DOOR TYPE HOLLOW METAL FRAMED STEEL DOOR


KITCHEN KITCHEN PROPOSED ELECTRICAL STOVE
OPENING TYPE SIDE HUNG SINGLE SHUTTER DOOR
MD1 DOOR FRAME 2mm THICK GALVANIZED STEEL HOLLOW FRAME WITH
QUANTITY 20 ITEM
STEEL STUD WALL ANCHORS WELDED TO FRAME .

FRAME FINISH OVEN CURED PRIMER + 2 COATS OF OVEN BAKED ENAMEL


COATING OF COLOUR TO ENGINEER'S APPROVAL EXISTING MARBLE TOP COUNTER
DOOR SHUTTER 45mm THICK HOLLOW METAL DOOR SHUTTER COMPRISING ² ²

OF 1.5mm THICK GALVNISED STEEL PLATE ON EITHER SIDE


WITH 10 MM GAUGE STEEL CHANNELS WELDED AND
REINFORCED TO EITHER SIDE OF STEEL SHEET,
EXISTING COUNTER TOP CABINET
DOOR LEAF OVEN CURED PRIMER + 2 COATS OF OVEN BAKED ENAMEL 1223

FINISH COATING OF COLOUR TO ENGINEER'S APPROVAL

IRONMONGERY STAINLESS STEEL APPROVED QUALITY PROPOSED WASHING MACHINE


AS PER SPECIFICATION 1223

OBMAS OBMAS SAMBO SAMBO OBMAS OBMAS SAMBO SAMBO

QUANTITY 13 ITEM
LOCATION IDF ROOM

FIRE RATING GENERAL NOTES


PROPOSED KITCHEN HOOD 1. ALL WORKS ARE TO BE CARRIED OUT IN
QUANTITY 2 ITEM ACCORDANCE WITH THE RELEVANT CODES OF
PRACTICE AND ALSO TO MEET THE LOCAL
AUTHORITY REQUIREMENTS.
2. DIMENSIONS ARE NOT TO BE SCALED FROM THIS
DRAWING.
3. DIMENSIONS ARE IN MILLIMETER, UNLESS NOTED
OTHERWISE.
4. THE CONTRACTOR IS TO VERIFY ALL DIMENSION
ON SITE BEFORE EXECUTING THE SITE.
5. ANY DISCREPANCIES, EITHER BETWEEN WRITTEN
DIMENSIONS AND SITE DIMENSIONS OR BETWEEN
THIS DRAWING AND OTHER CONTRACT DOCUMENTS OR
SUPPLIER'S DRAWINGS SHOULD BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE ENGINEER
BEFORE EXECUTING THE WORKS.
6. IN CASE OF ANY AMBIGUITIES & CONTRADICTIONS
CONTRACTOR SHALL ISSUE HIS FINDINGS IN THE FORM
OF (RFIs) TO THE ENGINEER FOR CLARIFICATION.
7. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH THE RELEVANT STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND SPECIFICATIONS.

KITCHEN KITCHEN
SHOWER TOILET

JANITOR F.H.C
F.H.C
CB 2 CB 1
LIFT-2
ELECT.
UP ROOM SUBSTATION 3 UP

PROPOSED BLOCK WORK WALL


LIFT-1 FINISHING PLASTER AND PAINT

LV PANEL 1

LV PANEL 2
L.V ROOM
TEL.
UP ROOM
PROPOSED IDF ROOM

STAIR-3

0 MAR. 2024 CONTRACT DOCUMENTS O.H


0 DEC. 2023
SEP 2023 NTT-01
TENDER O.H
0 JULY 2023 FINAL DESIGN O.H
0 JUNE 2023 CONCEPT DESIGN O.H
No. Date Description Chk'd By
R E V I S I O N
PROJECT:

CASS/BUF/1121
IMPROVEMENT OF BUS DEPOTS AND
PASSENGERS BUS STATION

LOCATION:

SHOWER TOILET

PLOT NO.: DISTRICT:

CLIENT:

JANITOR F.H.C
F.H.C
CB 2 CB 1
LIFT-2
DESIGN CONSULTANT:
ELECT.
UP ROOM SUBSTATION 3 UP

LIFT-1

LV PANEL 1

LV PANEL 2
L.V ROOM
ENGINEERING CONSULTANTS
P.O BOX 11676 DUBAI.UAE.
TEL. Phone: 04-3555859/ 04-3555949
UP ROOM Fax: 04-3597440/ 04-3555405
e-mail: alturath@emirates.net.ae

DRAWING TITLE:
STAIR-3
JEBEL ALI BUS DEPOT
ACCOMODATION BUILDING A
EXISTING AND PROPOSED FLOOR
DATE: DRAWN: CHECKED: APPROVED:
JUNE 2023 TEC MJ O.H
PROJECT NO. SCALE: DRAWING NO.: REV.

1341 1:100 JAD-ACC-ADT-100 0