CFC Mall Expansion Project

SUBMITTAL REVIEW COMMENTS FORM

REVIEW BY: DESIGN CONSULTANT SUPERVISION CONSULTANT OTHER (Specify)


PMC (HILL)

TYPE OF SUBMITTAL: Inspection Request IR NO.: IR-CR009P01-CIVIL-0002-01 Rev. NO.: 1


SUBJECT: Inspection for footing formwork , reinforcement and survey for main office REVIEW / APPROVAL STATUS: C

Item Title / Reference No. of Review Basis


Review Comments
No. Document Reviewed (Code)
1- Approved shop drawing should be attached to the IRF.
2- Form work quality is very poor and the following was noticed during the inspection: -
a. Footing dimensions are smaller than approved shop drawing.
b. surplus plywood was used in the form work of the foundation and beams.
c. sides of the foundations were not aligned vertically. C
d. openings in the sides of the foundation and beams.
3- cover of the foundation was not as mentioned in the approved shop drawing.
4- stirrups were not tied to the bottom of the beam (almost one stirrup was tied out of 8).
5- some of the short direction top rebar in F2 were placed in the third layer (T3). General Comments
Particular Comments:

Hazem ElMaghrabyAshraf El Project DirectorResident


Main Reviewer’s Name: Designation: Signature Date 21 Nov 2020
Degwi Engineer
Doc Control & Archiving Procedure Doc / Form No: CR009P01/000606 Rev.0
Page 1 of 2
CFC Mall Expansion Project Revision Date: NovNov-2020
CFC Mall Expansion Project

SUBMITTAL REVIEW COMMENTS FORM

Doc Control & Archiving Procedure Doc / Form No: CR009P01/000606 Rev.0
Page 2 of 2
CFC Mall Expansion Project Revision Date: NovNov-2020

You might also like