Flyer_DAC-2021_EN-2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 45

NEW AC/DC RANGES

DAC/DDC

www.citel.fr
OUR OBJECTIVE
the safety of your equipment for 80 years

A LONG HISTORY...
Since 1937, CITEL has been protecting installations around the world from
transient overvoltages that result from switching events and lightning strikes.
With a thorough understanding of local standards and regulations, along with
continuous investment in R&D, CITEL designs, manufactures and sells millions
of SPD’s each year.
CITEL develops many critical protection components internally.
Our teams all over the world are proud to help bring the market a
comprehensive product range of surge protectors with our unique client-
focused service & quality.

1937 1985 1988 1992 1996


CITEL founded CITEL USA CITEL Germany Reims factory CITEL Shanghaï

Factory & Sales

1988
1st AC modular
surge protector
1944
Manufacture of the
first surge arrester

2
A UNIQUE COMPETENCE
Citel is the leading manufacturer that exclusively produces both SPDs and
SPD components.

It constantly pioneers new technologies thanks to a bold innovation strategy,


high-level R&D and in-house regional test labs around the world.

Citel is recognized as an industry leader that is instrumental in the


development of international codes and standards.

2010 2012 2017 2021


CITEL Russia CITEL India CITEL Thailand CITEL Dubai

2012 2019
1997 Implementation of
a test laboratory in
AC / DC
new ranges
- AC surge protector new range
Reims
«DS» series
- VG Technology for AC surge protector 2017
New test laboratory
240 kA
SINCE 1998

Citel China

3RD GENERATION

3
PROTECT YOUR INSTALLATIONS
against transient overvoltages due to lightning strikes and
switching operations

Surge protector is an essential element of the protection strategy of our low


voltage and photovoltaic powerline installations. It guarantees the safety and
durability of the equipment and therefore contributes to a certain economy.

CITEL has completely renewed its product ranges in order to respond to the
different sectors of the market activities and to different standards increasingly
demanding.

Energy Photovoltaic Led lighting

Telecom Radiocom Industry

Internet
Datacenter Security of things

GDT Renewable Smart


& GSG energies city

4
INTERNATIONAL COLLABORATION
OF OUR TEAMS

DESIGNED IN EUROPE, USA & CHINA


In collaboration with an industrial design specialist, we have designed and created a more reliable, efficient, ergonomic
and practical module to anticipate the needs of our customers.

REALIZED MANUFACTURED CERTIFIED


IN FRANCE IN FRANCE AND CHINA IN GERMANY, USA AND
CHINA
Our research and development Manufactured, tested, controlled in our
teams worked in collaboration: own factories in France and China, with The necessary certification of the
research of the best materials, strict quality system and our own tools. new ranges have been carried out in
global technical design, tests in our the German, US and China accredited
various laboratories, follow-up of laboratories.
the certifications in order to design a
range that meets all the international
requirements.

5
THE NEW SPD GENERATION
Safer than ever !

SECURITY EXCLUSIVE KNOW-HOW


The SPD is the safety element of the installation. Its role CITEL is a specialist in the internal components of surge
is to protect the equipment against transient overvoltages protectors : the Gas Spark Gap (GSG) and the varistors
without failure. However, the SPD can be subjected to used are of our own design and we adapt them to obtain
maximum attack conditions and must be able to support the best performances.
them in safety disconnection mode. As the leader of surge
protection, we have designed surge protectors that meet WARRANTY
the most extreme constraints, beyond the normative Sure of our products, their warranty is extended to 5 years
requirements.

PERFORMANCE
In order to ensure total safety during the use of our surge
protectors, we have focused on :
- Safety disconnection

5-year
- Resistance to fire and short circuits
- Mechanical robustness

DESIGN AND ERGONOMICS


With its new design, CITEL surge protectors are easily WARRANTY
identifiable in your installation.

6
A NEW TECHNOLOGY

STRENGTHENING OF INCREASED QUALITY


INTERNAL PARTS OF PLASTIC MATERIALS
The robustness of the surge protector is essential to The choice of plastic materials is guided by :
support the electromechanical forces generated during - Normative compliance (fire resistance, environment)
the passage of transient currents. We have reduced the - Mechanical robustness
internal impedances, improved the contacts, simplified - Aesthetics
and reinforced the conductive parts.

INNOVATIVE DESIGN OF
INTERNAL DISCONNECTION
The internal disconnection mechanism of the device
is the essential element of safety. The new concept,
in case of internal heating, allows faster cut-off and
reinforced insulation after disconnection.

VG TECHNOLOGY BENEFITS OF
The exclusive VG Technology by CITEL offers unique
VG TECHNOLOGY
SINCE 1998

hybrid technology and multiple benefits not found in


traditional surge protection solutions. The patented
design incorporates a combination of MOV and Gas
filled Spark-Gap (GSG) technology to maximize
the SPD’s performance level and reliability. VG
3RD GENERATION
technology is optimized for robustness and network
NO AGEING NO FOLLOW
stability, providing the highest level of protection CURRENT
available.
DISCONNECTION
SYSTEM

HIGH SURGE INCREASED


SPECIFIC GSG MOV CURRENT TOV
CAPABILITY WITHSTAND
(Gas-filled-spark Gap) (Varistors)

7
BETTER USER EXPERIENCE
Products even more adapted to your needs

DIN RAIL MOUNTING


The modular format and symmetrical DIN
rail mounting make the surge protector
compliant with all installations.

VOLTAGE SELECTOR
Voltage selector avoid mistakes
when replacing module.

CONTACT QUALITY
Surge protectors must conduct very high impulse
currents and the plug-in contacts must withstand
these constraints. Quality of materials, increased
surface area, optimized elasticity and specific
surface treatment are used to meet these
requirements.

REMOTE SIGNALING
It indicates the state of the arrester remotely, and
is recommended when the arrester is not easily
accessible. In case of safety disconnection of one or
more modules, the internal contact switches and
can activate any remote device.

8
EASY PLUGGABLE
The plugging and unplugging operation is greatly
improved thanks to the quality of the module /
base contacts. The extraction of the pluggable
modules in case of maintenance is largely
facilitated.

DISCONNECTION INDICATOR
At the end of its life, the surge protector disconnects
from the network and must indicate its state. The
indicator clearly informs user about the need to
replace the out-of-service module.
Green = OK

Red or Not green = Disconnected

IDENTIFICATION
The colored band on the front of the module
makes it possible to identify its use or its
type. Grey for AC type 1, Red for AC type 2,
Blue for AC type 3, Orange for DC, Green for
N/PE branch (GDT).

RED = to replace RED = to replace RED = to replace RED = to replace RED = to replace

Surge Protector Surge Protector Surge Protector Surge Protector Surge Protector
Parafoudre Parafoudre Parafoudre Parafoudre Parafoudre

QR CODE
The QR code refers to the product installation
instruction allowing a permanent availability of
this essential document.

9
A CERTIFIED RANGE
for the standards of today and tomorrow

UL1449

STANDARDS
Surge Protection standards are changing and constraints are tightening
with each new edition. Several CITEL experts, members of national
and international committees, are involved in the development of these
standards, to be close to the requirements of the market.

This range has been designed to last and therefore to


anticipate future changes in standards.

INTERNAL TESTS
All the technological choices of our ranges were first tested in our testing
laboratories, to validate compliance with current standards, but also by
providing a functional margin beyond the requirements and anticipate future
developments.

CERTIFICATIONS
The final step is certification provided by the official certifications
organizations. Thanks to our expertise in surge tests, a part of the process
has been performed in our own facilities, under control of official certification
bodies.
Our Shanghai Laboratory has received a CERTIFICATE OF APPROVAL for
Customer’s Testing Facility, for the testing of electrotechnical equipment and
components under the IECEE System.
It has been approved by Dekra at Stage 2.

OUR MEANS OF TESTING


In order to test its products internally for standards compliance and to evolve toward
greater reliability CITEL has several centers of expertise and research(France, USA, China)
equipped with :

• Various transient surge current and surge voltage generators such as 8/20,
10/350,10/1000, 1.2/50...
• AC and DC Power Sources for short circuit and load current tests with possible
superimposed and synchronized pulses for AC sources.
• Various equipment’s for environmental tests (impact, vibration, climate, damp, fire…)

10
THE SPD WHICH PROTECTS
your equipment and our planet

Besides our constant work on the quality of our products, Our products use HALOGEN FREE material and comply
we take into account the ecological issues of our planet. with RoHS regulations.
CITEL is ISO 14001 certified and meet the requirements
This is why CITEL is working to optimize its production of the WEEE directive.
equipment in order to reduce the impact on the
environment. We have chosen for our new range high
quality raw materials.

Production respecting Purchase of materials Commitment


environmental standards compliant with the for recycling
environmental regulations

11
NEW DAC RANGE FOR AC & DC NETWORK

A COMPLETE RANGE WITH MANY OPTIONS


The new ranges of SPDs have been designed by CITEL to answer to all the needs of AC or DC power surge pro-
tection in accordance with standards. Type 1+2+3 versions, Compact units, integrated electrical fuse, DC power
versions, VG techonogy...all these features allow a optimized selection of the relevant SPD in close relation with the
installation requirements.
SINCE 1998

COMPACT INTEGRATED DC REMOTE MONOBLOC


3RD GENERATION VERSION FUSE POWER LINES SIGNALING VERSION

12
AC TYPE 1 RANGE
• Extreme duty pluggable Type 1+2+3 or Type 1+2 SPDs
DAC1-13S / DAC1-13VGS / OPTIONS designed to protect AC powerline at the main switchboard of an
DACN1-25S / ZPAC
installation equipped with lightning rod (LPS).
• Available in multipolar versions to protect single or 3-phase

SINCE 1998
AC networks
• Equipped with a high efficiency internal disconnector linked to
3RD GENERATION

a front disconnection indicator and a remote signalling feature .


MONOBLOC
• Very high discharge current capability in small dimensions
and the best possible behavior to the AC network (no follow
VERSION

current).
• In option : VG technology

AC TYPE 2 RANGE
• Pluggable surge protectors Type 2 or Type 2+3 designed to
DAC50S / DAC50VGS / DACFxxS/ OPTIONS protect AC powerline at the main switchboard of the installation.
DAC80S
• Based on high energy varistor equipped with thermal
SINCE 1998

disconnector and failure indicator to provide a maximum


protection efficiency, an high impulse current capability and a
improved reliability.
3RD GENERATION

• Available in multipolar version and in several voltages to pro-


INTEGRATED
FUSE tect single or 3-phase networks, with remote signalling.
• In option : VG technology.
• Available with an internal fuse against short-circuit currents,
which avoids the use of a external fuse or circuit-breaker as
requested by standard (DACF).

AC COMPACT RANGE
• Pluggable compact surge protectors Type 2 or Type 3 designed
DAC40CS / DAC15CS / DACN10S OPTIONS to protect electrical installation at the main switchboard or at
secondary panels.
• Compact format which allow to install it in limited space.
COMPACT
VERSION
• Based on high energy varistor equipped with thermal
disconnector and failure indicator, guaranteeing a maximum
protection efficiency, an high impulse current capability and a
improved reliability.
MONOBLOC
VERSION

• Available in 2 impulse current versions, in multi-


polar configuration and in several operating voltages
to protect all kind of single or 3-phase AC networks.
• Remote signaling

DC & DC COMPACT RANGE


DDCxxS /DDCxxCS • Type 1+2 or Type 2 pluggable surge protectors
OPTIONS designed for equipment connected to DC power-
lines.
COMPACT
VERSION
• Technology based on high energy varistor
equipped with thermal disconnection me-
chanism which offers protection efficiency
DC
POWER LINES
and and a maximal reliability.
• Available in compact version
from 12 to 350 Vdc DC powerline.
• Remote signaling

13
DACN1-25VGS-760 series
Type 1 + 2 + 3 AC Surge Protectors

• Type 1 + 2 + 3 Surge Protector


10-year
• for 690 V AC Network WARRANTY
• VG Technology
• In : 35 kA

SINCE 1998
• Iimp : 25 kA
• Remote signaling
• Optimized to TOV 3RD GENERATION

• EN 61643-11, IEC 61643-11, UL1449 ed.4 and GB/T 18802.1 compliance

CITEL model DACN1-25VGS-10-760


Description Type 1+2+3 AC surge protector - 1-pole
Max. AC operating voltage Uc 760 Vac
Temporary Over Voltage (TOV) UT 1000 Vac

DACN1-25VGS characteristics - 5 sec


Temporary Over Voltage (TOV)
characteristics - 20 mn
UT 1325 Vac

Residuel current - Leakage current at Uc Ipe none


Max. Load current (if connection serie) IL 100 A
Follow current If none
68 36 L/N (L/N)
Nominal discharge current In 35 kA
15 x 8/20µs impulses
Maximal discharge current Imax 70 kA
max. withstand @ 8/20 µs
Impulse current by pole Iimp 25 kA
max. withstand @ 10/350 µs by pole
SpecificFtenergy MI
by pole W/R 156 kJ/ohm
Withstand on combination waveform Uoc 6 kV
Class III test
Protection level Up 2.5 kV
@ In t°
GSG

110 (8/20µs) et 6 kV (1.2/50µs)


Residual voltage @ 25kA (8/20µs) Up-25kA 2.1 kV
Residual voltage @ 5kA (8/20µs) Up-5kA 1.6 kV
AdmissibleVshort-circuit current Isccr 50 000 A
Associated disconnectors
Thermal disconnector internal
Fuses C Fuse type gG - 315 A

25VGS 7.3
Existing upstream ground breaker (if any)
Mechanical characteristics
Type «S» or delayed
11
12
14

Dimensions see diagram, 2 TE (DIN43880)


Connection to network by screw terminals : 2.5-25 mm² (35mm² rigid)
Disconnection indicator 1 mechanical indicator Green/Red
36 L/N (L/N)
Remote signaling of disconnection output on changeover contact
Failsafe mode Disconnection from AC network
Max. voltage/current for remote signaling 250 V/0.5 A (AC), 30 V/3 A (DC)
1 2 3 signaling
Wiring for remote 1.5 mm² max.
MI Mounting Symmetrical rail 35 mm² (EN60715)
Ft
Operating temperature -40/+85°C
Protection rating IP20
t° Housing material Thermoplastic UL94 V-0
GSG

110
Standards
Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4 / GB/T 18802.1
V Certification TUV Rheinland
Part number
C 29221012

7.3
11
12
14

72 V: High energy varistor 108 144


GSG: Specific gas Tube
MI: Disconnection indicator
Ft: Thermal fuse
t°: Thermal disconnection system
2 L (L) N (N) L13 (L1) L2 (L2) L3 (L3) L1 (L1) L2 (L2) L3 (L3) N (N)
C: Contact for remote signal

14 Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI
DACN1-25VGS-760 series
Type 1 + 2 + 3 AC Multipolar Surge Protectors

DACN1-25VGS
68 36 L/N (L/N)
DACN1-25VGS-xx-xxx
Maximum operating voltage
Configuration: 10 (single-pole 1+0), 20 (2+0),
Ft MI
30 (3+0), 40 (4+0)
«S» = Remote signal
t° VG Technology

GSG
110
Iimp: 25 kA
Non pluggable
V

7.3
11
12
14

1 2 3

72 108 144

L (L) N (N) L1 (L1) L2 (L2) L3 (L3) L1 (L1) L2 (L2) L3 (L3) N (N)

Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI
GSG

GSG

GSG

GSG

GSG

GSG

GSG
GSG

GSG

t° t° t° t° t° t° t° t° t°

V V V V V V V V V

C C C C C C C C C
11
12
14

11
12
14

11
12
14

11
12
14

11
12
14
11
12
14

11
12
14

11
12
14

11
12
14

Protection Iimp Up Up Dimension


Model P/N Network AC System Diagram
Mode total L/PE N/PE DIN43880
DACN1-25VGS-40-760 29224012 400/690 V 3-phase+N TN System (4+0) L/PE and N/PE 100 kA 2.5 kV 2.5 kV 8TE 3
DACN1-25VGS-30-760 29223012 400/690 V 3-phase TN-C System (3+0) L/PE 75 kA 2.5 kV - 6TE 2
DACN1-25VGS-20-760 29222012 400 V Single phase IT System (2+0) L/PE and N/PE 50 kA 2.5 kV 2.5 kV 4 TE 1

15
DAC1-13VGS series
Type 1 + 2 + 3 AC Surge Protectors

• VG Technology
10-year
• In : 20 kA WARRANTY
• Iimp : 12.5 kA @ 10/350µs impulse
• Itotal : 50 kA @ 10/350µs impulse (3L+N)

SINCE 1998
• Remote signaling
• No leakage current
• Optimized to TOV 3RD GENERATION

• EN 61643-11, IEC 61643-1 certified


• UL1449 ed.4 compliance

CITEL Model DAC1-13VGS-10-320 DAC1-13VGS-10-275 DAC1-13VGS-10-150


Description Type 1+2+3 AC surge protector - 1-pole - pluggable
Max. AC operating voltage Uc 320 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) UT 335 Vac withstand 335 Vac withstand 180 Vac withstand
characteristic - 5 sec.

DAC1-13VG Temporary Over Voltage (TOV)


characteristic - 120 mn
UT 440 Vac withstand 440 Vac withstand 230 Vac withstand

Residual current - Leakage current at Uc Ipe None None None


Follow current If None None None
87.8
Nominal discharge current In 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
L/N
L/N Max. discharge current Imax 50 kA 50 kA 50 kA
max. withstand @ 8/20 µs by pole
Impulse current by pole Iimp 12.5 kA 12.5 kA 12.5 kA
max. withstand 10/350µs

Specific energy
GSG
by pole W/R 40 kJ/ohm 40 kJ/ohm 40 kJ/ohm
Withstand
MI on Combination waveform Uoc 6 kV 6 kV 6 kV
90 Class III test Ft

Protection level Up 1.5 kV 1.5 kV 1.5 kV
@ In (8/20µs) and 6 kV (1.2/50µs)
V
Residual Voltage @ 5 kA (8/20µs) Up-5kA 0.9 kV 0.7 kV 0.4 kV
Admissible short-circuit current Isccr 50 000 A 50 000 A 50 000 A
Associated
C disconnectors
7.3 Thermal disconnector Internal
N/PE
11
12
14

Fuses 125 A min. - 315 A max. - gG type / or CITEL SFD-13


18
Existing upstream ground fault breaker Type «S» or delayed
(if any)
Mechanical characteristics
1 2L/N 3 Dimensions
4 see diagram - 1TE (DIN43880)
5
L/N
L N L N L1 Connection
L2 to
L3Network L1 L2By screw
L3 terminals:
N 2.5-25 mm² (35mm² rigid)
L1 L2 L3 N
Failsafe Mode Disconnection from AC network
Disconnection indicator 1 mechanical indicator Green/Red
GSG Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
MI
90 Ft Wiring for remote signaling 1.5 mm² max.

Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
V
Protection rating IP20
Housing material Thermoplastic UL94 V-0
C Spare unit MDAC1-13VG-320 MDAC1-13VG-275 MDAC1-13VG-150
7.3 Standards
N/PE
11
12
14

18 Certification KEMA /EAC


Compliance IEC 61643-11 / EN 61643-11 / UL1449 ed.4
36 V : High energy varistor
36 network 54 72 72
GSG : Specific gas Tube Part number
Ft : Thermal fuse 821730321 821730221 821730121
3 C : Remote signaling contact 4 5
t° : Thermal disconnection system
N L N L1 L2 L3
L indicatorN L1 L2
L1 L3 L2 N L3 L1L1 L2 L2 L3 L3 N N L1 L2 L3
MI : Disconnection

GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG

16
MI
Ft
MI
Ft
MI
Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft MI Ft M

t° t° t° t° t° t° t° t° t° t° t° t° t°
DAC1-13VGS series
Type 1 + 2 + 3 AC Multipolar Surge Protectors

DAC1-13VGS-xx-xxx

DAC1-13VG Maximum operating voltage


Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
87.8 30 (3+0), 40 (4+0), 31 (3+1)
«S» Remote signal
L/N
L/N «VG» VG-Technology
«13» Iimp: 12.5 kA

GSG
MI
90 Ft

7.3 N/PE
11
12
14

18

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG

MI MI MI MI MI Ft MI Ft MI
Ft Ft Ft MI Ft Ft MI Ft MI Ft Ft MI Ft MI Ft MI Ft MI Ft MI Ft

t° t° t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V GSG
GSG

C C C C C

PE PE PE PE
11
12
14

PE
11
12
14

11
12
14

11
12
14
11
12
14

Characteristics
Model P/N Network AC system Protection Itotal Up Up Up Dimension Diagram
Mode L/PE L/N N/PE DIN43880
DAC1-13VGS-31-320 821730324 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 1.5 kV 1.5 kV 4 TE
DAC1-13VGS-31-275 821730224 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 1.5 kV 1.5 kV 4 TE 5
DAC1-13VGS-31-150 821730124 120/208 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 1.5 kV 1.5 kV 4 TE
DAC1-13VGS-40-320 821730344 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 1.5 kV - 1.5 kV 4 TE
DAC1-13VGS-40-275 871730244 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 1.5 kV - 1.5 kV 4 TE 4
DAC1-13VGS-40-150 821730144 120/208 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 1.5 kV - 1.5 kV 4 TE
DAC1-13VGS-30-320 821730323 230/400 V 3-Phase TNC System (3+0) L/PE 37.5 kA 1.5 kV - - 3 TE
DAC1-13VGS-30-275 821730223 230/400 V 3-Phase TNC System (3+0) L/PE 37.5 kA 1.5 kV - - 3 TE 3
DAC1-13VGS-30-150 821730123 120/208 V 3-Phase TNC System (3+0) L/PE 37.5 kA 1.5 kV - - 3 TE
DAC1-13VGS-11-320 821730342 230 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 1.5 kV 1.5 kV 2 TE
DAC1-13VGS-11-275 821730242 230 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 1.5 kV 1.5 kV 2 TE 2
DAC1-13VGS-11-150 821730142 120 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 1.5 kV 1.5 kV 2 TE
DAC1-13VGS-20-320 821730322 230 V single phase TN System (2+0) L/PE and N/PE 25 kA 1.5 kV - 1.5 kV 2 TE
DAC1-13VGS-20-275 821730222 230 V single phase TN System (2+0) L/PE and N/PE 25 kA 1.5 kV - 1.5 kV 2 TE 1
DAC1-13VGS-20-150 821730122 120 V single phase TN System (2+0) L/PE and N/PE 25 kA 1.5 kV - 1.5 kV 2 TE

17
DAC1-13S SERIES
Type 1 + 2 AC Surge Protectors

• Pluggable Type 1+2 AC power SPD


• In : 20 kA
• Iimp : 12.5 kA @ 10/350µs impulse
5-year
• Itotal : 50 kA @ 10/350µs impulse (3L+N) WARRANTY
• Remote signaling
• EN 61643-11, IEC 61643-1 certified
• UL1449 ed.4 compliance

CITEL Model DAC1-13S-10-440 DAC1-13S-10-320 DAC1-13S-10-275 DAC1-13S-10-150


Description 1+2 AC surge protector - 1-pole - pluggable
Max. AC operating voltage Uc 440 Vac 320 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) UT 580 Vac 335 Vac 335 Vac 180 Vac
Characteristic - 5 sec. withstand withstand withstand withstand
Temporary Over Voltage (TOV) UT 770 Vac 440 Vac 440 Vac 230 Vac
Characteristic -120 mn disconnection disconnection disconnection disconnection

87.8
Residual current Leakage current at Uc Ipe
Follow current If
< 1 mA
None
< 1 mA
None
DAC1-13
< 1 mA
None
< 1 mA
None
Nominal discharge current In 20 kA 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
L/N Max. discharge current Imax 50 kA 50 kA 50 kA 50 kA
L/N
max. withstand @ 8/20 µs by pole

Impulse current by pole Iimp 12.5 kA 12.5 kA 12.5 kA 12.5 kA


max. withstand 10/350µs

Specific energy by poleMI W/R 40 kJ/ohm 40 kJ/ohm 40 kJ/ohm 40 kJ/ohm


Ft
90 Protection level @ In (8/20µs) Up 1.7 kV 1.6 kV 1.3 kV 0.9 kV
Residual voltage @ 5kA (8/20µs)
t° Up- 1.5 kV 1.2 kV 1 kV 0.6 kV
5kA
V
Admissible short-circuit current Isccr 50 000 A 50 000 A 50 000 A 50 000 A
Associated disconnectors
Thermal disconnectorC internal
Fuses

DAC1-13
N/PE 125 A min. - 315 A max. - gG type / or CITEL SFD-13
11
12
14

7.3
Existing upstream ground fault breaker Type "S" or delayed
18 (if any)
Mechanical characteristics
Dimensions see diagram, 1TE, DIN 43880
L/N Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)
L/N
Failsafe mode Disconnection from AC network
1 2 3 4 5
Disconnection indicator 1 mechanical indicator Green/Red
L N L N L1 Max.
L2 voltage/current
L3 for remote signaling
L1 250
L2V/0.5 AL3
(AC) / 30 N
V/3 A (DC) L1 L2 L3 N
Wiring for remote signaling max 1.5 mm²
MI
Ft Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C

Protection rating IP20
V Housing material Thermoplastic UL94 V-0
Spare unit MDAC1-13-440 MDAC1-13-320 MDAC1-13-275 MDAC1-13-150
Standards
C Certification EAC KEMA / EAC KEMA / EAC KEMA / EAC
Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
N/PE
11
12
14

Part number
18 821710421 821710321 821710221 821710121
V : High energy varistor network
36 Ft : Thermal fuse 36 54 72 72
C : Remote signaling contact
t° : Thermal disconnection system
MI : Disconnection indicator

3 4 5
L/N L/N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

18 L1 L2 L3 N
MI MI MI MI MI MI MI MI MI MI MI MI MI
Ft MI Ft MI Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft
DAC1-13S SERIES
Type 1 + 2 AC Multipolar Surge Protectors

DAC1-13S-xx-xxx

Maximum operating voltage


Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
30 (3+0), 40 (4+0), 31 (3+1)

87.8
DAC1-13 «S» Remote signal
«13» Iimp: 12.5 kA

L/N
L/N

MI
Ft
90

N/PE
11
12
14

7.3

18

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L/N L/N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

L1 L2 L3 N
MI MI MI MI MI MI MI MI MI MI MI MI MI
Ft MI Ft MI Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft
Ft

t° t° t° t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V
GSG GSG

C C C C C

PE PE PE/PEN PE PE
11
12
14

11
12
14
11
12
14
11
12
14
11
12
14

Model P/N Network AC system Protection Itotal Up Up Up Dimension Diagram


Mode L/PE L/N N/PE DIN43880
DAC1-13S-31-320 821710344 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 1.6 kV 1.5 kV 4 TE
DAC1-13S-31-275 821710244 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 1.3 kV 1.5 kV 4 TE 5
DAC1-13S-31-150 821710144 120/208 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE 50 kA - 0.9 kV 1.5 kV 4 TE
DAC1-13S-40-440 821710424 230/400 V 3-Phase+N IT System (4+0) L/PE and N/PE 50 kA 1.7 kV - 1.7 kV 4 TE
DAC1-13S-40-320 821710324 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 1.6 kV 1.6 kV 4 TE
4
DAC1-13S-40-275 821710224 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 1.3 kV - 1.3 kV 4 TE
DAC1-13S-40-150 821710124 120/208 V 3-Phase+N TNS System (4+0) L/PE and N/PE 50 kA 0.9 kV - 0.9 kV 4 TE
DAC1-13S-30-440 821710423 230/400 V 3-Phase IT System (3+0) L/PE 37.5 kA 1.7 kV - - 3 TE
DAC1-13S-30-320 821710323 230/400 V 3-Phase TNC System (3+0) L/PE 37.5 kA 1.6 kV - - 3 TE
3
DAC1-13S-30-275 821710223 230/400 V 3-Phase TNC System (3+0) L/PE 37.5 kA 1.3 kV - - 3 TE
DAC1-13S-30-150 821710123 120/208 V 3-Phase TNC System (3+0) L/PE 37.5 kA 0.9 kV - - 3 TE
DAC1-13S-11-320 821710342 230 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 1.6 kV 1.5 kV 2 TE
DAC1-13S-11-275 821710242 230 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 1.3 kV 1.5 kV 2 TE 2
DAC1-13S-11-150 821710142 120 V single phase TT-TN System (1+1) L/N and N/PE 25 kA - 0.9 kV 1.5 kV 2 TE
DAC1-13S-20-440 821710422 230 V single phase IT System (2+0) L/PE and N/PE 25 kA 1.7 kV - 1.7 kV 2 TE
DAC1-13S-20-320 821710322 230 V single phase TN System(2+0) L/PE and N/PE 25 kA 1.6 kV - 1.6 kV 2 TE
1
DAC1-13S-20-275 821710222 230 V single phase TN System(2+0) L/PE and N/PE 25 kA 1.3 kV - 1.3 kV 2 TE
DAC1-13S-20-150 821710122 120 V single phase TN System (2+0) L/PE and N/PE 25 kA 0.9 kV - 0.9 kV 2 TE

19
ZPAC1 SERIES
Type 1+2+3 AC surge protector - 3-phase+N
• Type 1+2+3 AC SPD for 40 mm busbar systems

• Ultra fast and error-free mounting 10-year


• In : 20 kA WARRANTY
• Iimp : 12.5kA or 8 kA

• Iimp total : 50 kA or 32 kA

• No leakage current

• Optimized to TOV

SINCE 1998
• EN 61643-11 / IEC 61643-11 certified

• UL1449 ed. 4 compliance 3RD GENERATION

• VDE-AR-N 4100 compliance (use of Type 1 overvoltage


protection devices (SPD) in main power supply systems)
ZPAC CITEL Model ZPAC1-13VG-31-275 ZPAC1-8VG-31-275
Network 230/400 V 3L+N 230/400 V 3L+N
Max. AC operating voltage Uc 275 Vac 275 Vac
Temporary Over Voltage (TOV) UT 335 Vac withstand 335 Vac withstand
characteristic - 5 sec.
Temporary Over Voltage (TOV) UT 440 Vac withstand 440 Vac withstand
characteristic - 120 mn
L1 L2 L3
Temporary Over Voltage N/PE (TOV HT) UT 1200V/300 V/200 ms 1200V/300 V/200 ms
withstand withstand
Residual current - Leakage current at Uc Ipe None None
Follow current
MI
GSG
MI
GSG
MI
GSG
If None None
Ft Ft Ft
Nominal discharge
t° current
t° t° In 20 kA 20 kA
15 x 8/20 µs impulses
211

V V V
Max. discharge current Imax 50 kA 50 kA
max. withstand @ 8/20 µs by pole
Impulse current by pole
N
Iimp 12.5 kA 8 kA
max. withstand 10/350µs
Specific energy by pole W/R 40 kJ/ohm 16 kJ/ohm
GSG
Total lightning current - @ 10/350µs by pole Itotal 50 kA 32 kA
Withstand on Combination waveform Uoc 6 kV 6 kV
Class III test
Protection level PE Up L/N 1.5 kV 1.5 kV
@ In (8/20µs) and 6 kV (1.2/50µs) Up N/PE 1.5 kV 1.5 kV
Residual Voltage @ 5 kA (8/20µs) Up-5kA 0.7 kV 0.7 kV
Admissible short-circuit current Isccr 50 000 A 50 000 A
57 18.3 53.8 Associated disconnectors
95 Thermal disconnector Internal
Fuses (existing upstream) 160 A max. - gG type
Mechanical characteristics
L1 L2 L3
Dimensions see diagram - 3TE (DIN43880)
Connection to Network Mounting on 40 mm busbar and wire for PE: 10-50 mm²
Failsafe Mode Disconnection from AC network
GSG GSG GSG
MI MI MI Disconnection indicator 1 mechanical indicator by pole Green/Red
Ft Ft Ft
t° t° t° Mounting Symmetrical rail 35 mm (EN60715)
V V V Operating temperature -40/+85°C
Protection rating IP20
N Housing material Thermoplastic UL94 V-0
Spare unit MDAC1-13VG-275 MDAC1-8VG-275
GSG Standards
Certification KEMA /EAC
Compliance IEC 61643-11 / EN 61643-11 / UL1449 ed.4
PE
Part number
64004 64006
V : High energy varistor network
GSG : Specific gas Tube
53.8 Ft : Thermal fuse
t° : Thermal disconnection system
MI : Disconnection indicator

20
DAC80S SERIES
Type 2 AC surge protector

• Re-inforced Type 2 Surge Protector


• In: 40 kA
10-year
• Imax: 80 kA WARRANTY
• Pluggable module by phase
• Remote Signaling
• IEC 61643-11, EN 61643-11 and UL1449 ed.4 compliance

CITEL Model DAC80S-10-440 DAC80S-10-320 DAC80S-10-275 DAC80S-10-150


Description Type 2 AC surge protector - one-pole - pluggable
Maximum AC operating voltage Uc 440 Vac 320Vac 275 Vac 150 Vac

DAC50 Temporary Over Voltage (TOV)


Charasteristics - 5 sec.
UT
580 Vac
withstand
335 Vac
withstand
335 Vac
withstand
180 Vac
withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 440 Vac 230 Vac
UT
Charasteristics -120mn disconnection disconnection disconnection disconnection
Residual current
Ipe < 1 mA < 1 mA < 1 mA < 1 mA
Leakage current at Uc
73 Follow current If None None None None
Nominal discharge current
L/N L/N In 40 kA 40 kA 40 kA 40 kA
15 x 8/20 µs impulses

Max. discharge current


Imax 80 kA 80 kA 80 kA 80 kA
max. withstand @ 8/20 µs by pole
Protection level @ In (8/20µs) Up 1.8 kV 1.4 kV 1.2 kV 0.9 kV
MI
Residual voltageFt@ 5 kA (8/20µs) Up-5kA 1.4 kV 1 kV 0.9 kV 0.7 kV
Admissible short-circuit current Isccr 50 000 A 50 000 A 50 000 A 50 000 A

90 Associated disconnectors
Thermal disconnector
V internal
Fuses 50 A min. - 125 A max. - gG Type
Installation ground fault breaker
C Type "S" or delayed
(if any)
MechanicalN/PE
characteristics
11
12
14

7.3 Dimensions see diagram - 1TE (DIN43880)


44 18 Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)
Failsafe mode Disconnection from network
67 Disconnection indicator 1 mechanical indicator Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30V/3 A (DC)
Wiring for remote signaling max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
L/N L/N Protection rating IP20
1 2 Housing
3 material Thermoplastic
4 UL94 V-0 5
Spare unit MDAC80-440 MDAC80-320 MDAC80-275 MDAC80-150
L N L N L1
StandardsL2 L3 L1 L2 L3 N L1 L2 L3
Compliance EN 61643-11 / IEC 61643-11 / UL1449 ed.4
MI
Ft
Part number
821210421 821210321 821210221 821210121

N/PE
11
12
14

V : High energy varistor network


18 Ft : Thermal fuse
36 C : Remote signaling contact36 54 72 72
t° : Thermal disconnection system
MI : Disconnection indicator
L/N L/N L N L1 L2 L3 L1 L2 L3 PEN L1 L2

22
L1 L2 L3 N
DAC80S SERIES
Type 2 AC Multipolar Surge Protector

DAC80S-xx-xxx
DAC50

73
Maximum operating voltage

L/N
Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
L/N
30 (3+0), 40 (4+0), 31 (3+1)
«S» Remote signal
MI
Ft
«80» Imax: 80 kA

90
V

N/PE
11
12
14

7.3
44 18

67

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L/N L/N L N L1 L2 L3 L1 L2 L3 PEN L1 L2 L3 N

L1 L2 L3 N
MI MI MI MI MI MI MI MI MI MI MI MI MI
Ft MI Ft MI Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft
Ft

t° t° t° t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V
GSG GSG

C C C C C

PE PE PE/PEN PE
11
12
14

11
12
14

PE
11
12
14

11
12
14
11
12
14

Protection Up Up Up Dimensions
Model Part number Network AC system Diagram
Mode L/PE L/N N/PE DIN43880
DAC80S-31-320 821210344 230/400 V 3-phase+N TT-TNS system (3+1 L/N and N/PE - 1.4 kV 1.5 kV 4 TE
DAC80S-31-275 821210244 230/400 V 3-phase+N TT-TNS system (3+1 L/N and N/PE - 1.2 kV 1.5 kV 4 TE
5
DAC80S-31-150 821210144 120/208 V 3-phase+N TT-TNS system (3+1 L/N and N/PE - 0.9 kV 1.5 kV 4 TE
DAC80S-40-440 821210424 230/400 V 3-phase+N IT system (4+0) L/PE and N/PE 1.8 kV - 1.8 kV 4 TE
DAC80S-40-320 821210324 230/400 V 3-phase+N TNS system (4+0) L/PE and N/PE 1.4 kV - 1.4 kV 4 TE
4
DAC80S-40-275 821210224 230/400 V 3-phase+N TNS system (4+0) L/PE and N/PE 1.2 kV - 1.2 kV 4 TE
DAC80S-40-150 821210124 120/208 V 3-phase+N TNS system (4+0) L/PE and N/PE 0.9 kV - 0.9 kV 4 TE
DAC80S-30-440 821210423 230/400 V 3-phase IT system (3+0) L/PE 1.8 kV - - 3 TE
DAC80S-30-320 821210323 230/400 V 3-phase TNC system (3+0) L/PE 1.4 kV - - 3 TE
DAC80S-30-275 821210223 230/400 V 3-phase TNC system (3+0) L/PE 1.2 kV - - 3 TE
DAC80S-30-150 821210123 120/208 V 3-phase TNC system (3+0) L/PE 0.9 kV - - 3 TE
DAC80S-11-320 821210342 230 V single phase TT-TN system(1+1) L/N and N/PE - 1.4 kV 1.5 kV 2 TE
DAC80S-11-275 821210242 230 V single phase TT-TN system(1+1) L/N and N/PE - 1.2 kV 1.5 kV 2 TE
2
DAC80S-11-150 821210142 120 V single phase TT-TN system(1+1) L/N and N/PE - 0.9 kV 1.5 kV 2 TE
DAC80S-20-440 821210422 230 V single phase IT system (2+0) L/PE and N/PE 1.8 kV - 1.8 kV 2 TE
DAC80S-20-320 821210322 230 V single phase TN system (2+0) L/PE and N/PE 1.4 kV - 1.4 kV 2 TE
1
DAC80S-20-275 821210222 230 V single phase TN system (2+0) L/PE and N/PE 1.2 kV - 1.2 kV 2 TE
DAC80S-20-150 821210122 120 V single phase TN system (2+0) L/PE and N/PE 0.9 kV - 0.9 kV 2 TE

23
DAC50VGS SERIES
Type 2 + 3 AC Surge Protectors
10-year
WARRANTY
• Type 2 + 3 AC surge protectors
• VG Technology

SINCE 1998
• In: 20 kA
• No leakage current
• Optimized to TOV 3RD GENERATION

• Remote signaling
• IEC 61643‑11, EN 61643‑11 certified
• UL1449 ed.4 compliance

CITEL Model DAC50VGS-10-320 DAC50VGS-10-275 DAC50VGS-10-150


Description Type 2 AC surge protector - 1-pole - pluggable
Maximum AC operating voltage Uc 320 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) UT 335 Vac withstand 335 Vac withstand 180 Vac withstand

DAC50VG Characteristic - 5 sec.


Temporary Over Voltage (N/PE TOV)
Characteristic -120mn
UT 440 Vac
withstand
440 Vac
withstand
230 Vac
withstand
Residual current Leakage current at Uc Ipe None None None
73 Follow current If None None None
Nominal discharge current In 20 kA 20 kA 20 kA
L/N
5 x 8/20 µs impulses
L/N
Maximum discharge current Imax 50 kA 50 kA 50 kA
max. withstand 8/20µs by pole
Withstand on combination Uoc 6 kV 6 kV 6 kV
waveform - Class III test
GSG
Protection MI
level Up 1.5 kV 1.5 kV 1.5 kV
Ft
@ In (8/20µs) and 6 kV(1.2/50µs)
90 t°
Residual voltage @ 5 kA (8/20µs) Up- 0.9 kV 0.7 kV 0.4 kV
5kA
V
Admissible short-circuit current Isccr 50 000 A 50 000 A 50 000 A
Associated disconnectors
C
Thermal disconnector internal
7.3 Fuses 50 A min. - 160 A max. - gG Type
N/PE
11
12
14

44 18 Existing upstream ground fault breaker Type "S" or delayed


(if any)
67
Mechanical characteristics
Dimensions see diagram - 1 TE (DIN43880)
Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)
Failsafe mode Disconnection from AC network
L/N Disconnection indicator 1 mechanical indicator Green/Red
L/N
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling max. 1.5 mm²
1 2 3 Mounting 4 Symmetrical rail 35 mm (EN60715) 5
GSG Operating temperature -40/+85°C
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N
MI
Protection rating IP20
Ft
t° Housing material Thermoplastic UL94 V-0
Spare unit MDAC50VG-320 MDAC50VG-275 MDAC50VG-150
V
Standards
Certification KEMA / EAC
C
Compliance EN 61643-11 / IEC 61643-11 / UL1449 ed.4
Part number
3 N/PE
11
12
14

821130321 821130221 821130121


18

V : High energy varistor network


GSG : Specific gas Tube
36 Ft : Thermal fuse 36 54 72 72
C : Remote signaling contact
t° : Thermal disconnection system
MI : Disconnection indicator
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

24 3 4 5
DAC50VGS SERIES
Type 2+3 AC Multipolar Surge Protectors

DAC50VGS-xx-xxx

DAC50VG
Maximum operating voltage
73 Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
L/N 30 (3+0), 40 (4+0), 31 (3+1)
L/N
«S» Remote signal
«VG» VG Technology
GSG «50» Imax: 50 kA
MI
Ft
90 t°

7.3 N/PE
11
12
14

44 18

67

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG GSG

MI MI MI MI MI Ft MI Ft MI
Ft Ft Ft MI Ft Ft MI Ft MI Ft Ft MI Ft MI Ft MI Ft MI Ft MI Ft

t° t° t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V GSG
GSG

C C C C C

PE PE PE PE
11
12
14

PE
11
12
14
11
12
14

11
12
14
11
12
14

Protection Up Up Up Dimension
Model P/N Network AC system Diagram
mode L/PE L/N N/PE DIN43880
DAC50VGS-31-320 821130344 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.5 kV 1.5 kV 4 TE
DAC50VGS-31-275 821130244 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.5 kV 1.5 kV 4 TE 5
DAC50VGS-31-150 821130144 120/208 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.5 kV 1.5 kV 4 TE
DAC50VGS-40-320 821130324 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.5 kV 1.5 kV 4 TE
DAC50VGS-40-275 821130224 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.5 kV - 1.5 kV 4 TE 4
DAC50VGS-40-150 821130124 120/208 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.5 kV - 1.5 kV 4 TE
DAC50VGS-30-320 821130323 230/400 V 3-Phase TNC System (3+0) L/PE 1.5 kV - - 3 TE
DAC50VGS-30-275 821130223 230/400 V 3-Phase TNC System (3+0) L/PE 1.5 kV - - 3 TE 3
DAC50VGS-30-150 821130123 120/208 V 3-Phase TNC System (3+0) L/PE 1.5 kV - - 3 TE
DAC50VGS-11-320 821130342 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.5 kV 1.5 kV 2 TE
DAC50VGS-11-275 821130242 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.5 kV 1.5 kV 2 TE 2
DAC50VGS-11-150 821130142 120 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.5 kV 1.5 kV 2 TE
DAC50VGS-20-320 821130322 230 V Single Phase TN System (2+0) L/PE and N/PE 1.5 kV - 1.5 kV 2 TE
DAC50VGS-20-275 821130222 230 V Single Phase TN System (2+0) L/PE and N/PE 1.5 kV - 1.5 kV 2 TE 1
DAC50VGS-20-150 821130122 120 V Single Phase TN System (2+0) L/PE and N/PE 1.5 kV - 1.5 kV 2 TE

25
DAC50S SERIES
Type 2 AC surge protector
5-year
• Type 2 AC Surge Protector WARRANTY
• In: 20 kA
• Imax: 50 kA
• Pluggable module for each phase
• Remote signaling
• IEC 61643‑11, EN 61643‑11 certified
• UL1449 ed.4 compliance
UL1449

CITEL Model DAC50S-10-760 DAC50S-10-440 DAC50S-10-275 DAC50S-10-150


Description Type 2 AC surge protector - one-pole - pluggable
Maximum AC operating voltage Uc 760 Vac 440 Vac 275 Vac 150 Vac

DAC50 Temporary Over Voltage (TOV)


Charasteristics - 5 sec.
UT
1000 Vac
withstand
580 Vac
withstand
335 Vac
withstand
180 Vac
withstand
Temporary Over Voltage (TOV) 1325 Vac 770 Vac 440 Vac 230 Vac
UT
Charasteristics -120mn disconnection disconnection disconnection disconnection
Residual current
Ipe < 1 mA < 1 mA < 1 mA < 1 mA
Leakage current at Uc
73 Follow current If None None None None
Nominal discharge current
L/N L/N In 20 kA 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 50 kA 50 kA 50 kA 50 kA
max. withstand @ 8/20 µs by pole
Protection level @ In (8/20µs) Up 2.9 kV 2 kV 1.25 kV 0.9 kV
MI
Residual voltageFt@ 5 kA (8/20µs) Up-5kA 2.6 kV 1.5 kV 1 kV 0.6 kV
Admissible short-circuit current Isccr 50 000 A 50 000 A 50 000 A 50 000 A

90 Associated disconnectors
Thermal disconnector
V internal
Fuses 50 A min. - 125 A max. - gG Type
Installation ground fault breaker
C Type "S" or delayed
(if any)
MechanicalN/PE
characteristics
11
12
14

7.3 Dimensions see diagram - 1TE (DIN43880)


44 18 Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)
Failsafe mode Disconnection from network
67 Disconnection indicator 1 mechanical indicator Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30V/3 A (DC)
Wiring for remote signaling max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
L/N L/N Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
1 2 3 4 5
Spare unit MDAC50-760 MDAC50-440 MDAC50-275 MDAC50-150
L N L N L1
StandardsL2 L3 L1 L2 L3 N L1 L2 L3
MI
Ft Certification OVE / EAC / UL
Compliance EN 61643-11 / IEC 61643-11 / UL1449 ed.4

0
t° Part number
821110721 821110421 821110221 821110121
V

N/PE
11
12
14

3
18 V : High energy varistor network
Ft : Thermal fuse
36 C : Remote signaling contact36 54 72 72
t° : Thermal disconnection system
MI : Disconnection indicator
L/N L/N L N L1 L2 L3 L1 L2 L3 PEN L1 L2

26
L1 L2 L3 N
DAC50S SERIES
Type 2 AC Multipolar Surge Protector

DAC50S-xx-xxx
DAC50 Maximum operating voltage
Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
30 (3+0), 40 (4+0), 31 (3+1)
73
«S» Remote signal
L/N L/N
«50» Imax: 50 kA

MI
Ft


90
V

N/PE
11
12
14

7.3
44 18

67

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L/N L/N L N L1 L2 L3 L1 L2 L3 PEN L1 L2 L3 N

L1 L2 L3 N
MI MI MI MI MI MI MI MI MI MI MI MI MI
Ft MI Ft MI Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft
Ft

t° t° t° t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V
GSG GSG

C C C C C

PE PE PE/PEN PE
11
12
14

11
12
14

PE
11
12
14

11
12
14
11
12
14

Protection Up Up Up Dimensions
Model Part number Network AC system Diagram
Mode L/PE L/N N/PE DIN43880
DAC50S-31-275 821110244 230/400 V 3-phase+N TT-TNS system (3+1 L/N and N/PE - 1.25 kV 1.5 kV 4 TE
5
DAC50S-31-150 821110144 120/208 V 3-phase+N TT-TNS system (3+1 L/N and N/PE - 0.9 kV 1.5 kV 4 TE
DAC50S-40-440 821110424 230/400 V 3-phase+N IT system (4+0) L/PE and N/PE 2 kV - 2 kV 4 TE
DAC50S-40-275 821110224 230/400 V 3-phase+N TNS system (4+0) L/PE and N/PE 1.25 kV - 1.25 kV 4 TE 4
DAC50S-40-150 821110124 120/208 V 3-phase+N TNS system (4+0) L/PE and N/PE 0.9 kV - 0.9 kV 4 TE
DAC50S-30-760 821110723 690 V 3-phase TNC system (3+0) L/PE 2.9 kV - - 3 TE
DAC50S-30-440 821110423 230/400 V 3-phase IT system (3+0) L/PE 2 kV - - 3 TE
3
DAC50S-30-275 821110223 230/400 V 3-phase TNC system (3+0) L/PE 1.25 kV - - 3 TE
DAC50S-30-150 821110123 120/208 V 3-phase TNC system (3+0) L/PE 0.9 kV - - 3 TE
DAC50S-11-275 821110242 230 V single phase TT-TN system(1+1) L/N and N/PE - 1.25 kV 1.5 kV 2 TE
2
DAC50S-11-150 821110142 120 V single phase TT-TN system(1+1) L/N and N/PE - 0.9 kV 1.5 kV 2 TE
DAC50S-20-440 821110422 230 V single phase IT system (2+0) L/PE and N/PE 2 kV - 2 kV 2 TE
DAC50S-20-275 821110222 230 V single phase TN system (2+0) L/PE and N/PE 1.25 kV - 1.25 kV 2 TE 1
DAC50S-20-150 821110122 120 V single phase TN system (2+0) L/PE and N/PE 0.9 kV - 0.9 kV 2 TE

27
DACF25S SERIES
Type 2 AC surge protectors with integrated fuse

• Surge protectors with Integrated Fuse (SPDI)


• Not external fuse required
INTEGRATED
• In: 15 kA FUSE

• Imax: 25 kA
• Pluggable module for each phase
• Remote signaling
• IEC 61643‑11, EN 61643‑11 certified
5-year
• UL1449 ed.4 compliance WARRANTY

CITEL Model DACF25S-10-440 DACF25S-10-320 DACF25S-10-275 DACF25S-10-150


Description Type 2 AC SPD with integrated fuse (SPDI) - 1-pole - pluggable
Max. AC operating voltage Uc 440 Vac 320 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) 580 Vac 335 Vac 335 Vac 180 Vac

DACF25
UT
Characteristics - 5 sec. withstand withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 440 Vac 230 Vac
UT
Characteristics -120 mn disconnection disconnection disconnection disconnection
Residual current
Ipe < 1 mA < 1 mA < 1 mA < 1 mA
Leakage current at Uc
73 Follow current If None None None None
Nominal discharge currentL/N
L/N In 15 kA 15 kA 15 kA 15 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 25 kA 25 kA 25 kA 25 kA
max. withstand @ 8/20 µs by pole
Protection level @ In (8/20µs) Up 2 kV 1.5 kV 1.25 kV 0.9 kV
F
Residual voltage @ 5 kA (8/20µs) Up-5kA 1.5 kV 1.2 kV 1 kV 0.6 kV
MI
Admissible short-circuit current
Ft Isccr 100 000 A 100 000 A 100 000 A 100 000 A
90 Associated disconnectors

Thermal disconnector internal
Fuses V internal (equivalent AC rating : 40 A, gG Type)
Existing upstream ground fault
Type "S" or delayed
breaker (if any)
C
Mechanical characteristics
Dimensions see diagram, 1 TE (DIN43880)
7.3 N/PE
11
12
14

Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)


44 18
Failsafe mode Disconnection from network
67 Disconnection indicator 1 mechanical indicator Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
L/N L/N Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
1 2 3 Spare unit 4 MDACF25-440 MDACF25-320 5
MDACF25-275 MDACF25-150
F Standards
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N
MI Certification EAC EAC KEMA / EAC EAC
Ft Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
t° Part number
821410421 821410321 821410221 821410121
V
*) SPDI :SPD including all its safety devices : thermal disconnector AND electrical fuse against short circuit currents.

N/PE
11
12
14

18 V : High energy varistor network


F : Overcurrent protection (fuse)
Ft : Thermal fuse
C : Remote signaling contact
t° : Thermal disconnection system
36 MI : Disconnection indicator36 54 72 72

3 4 5
28
LL1 N
L2 L3 L NL1 L2 L3 L1 N L2 L3 L1 L2 L1 L3 L2 N L3 N L1 L2 L3
DACF25S SERIES
Type 2 AC Multipolar surge protectors
with integrated fuse

DACF25 DACF25S-xx-xxx

73 Maximum operating voltage


L/N L/N Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
30 (3+0), 40 (4+0), 31 (3+1)
«S» Remote signal
F

MI «25» Imax: 25 kA
Ft
90 t° «F» Integrated overcurrent protection (fuse)
V

7.3 N/PE
11
12
14

44 18

67

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

F
F F F F F F F F F F F F
MI MI MI
MI MI MI MI MI MI MI MI MI MI MI MI Ft
Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft

t° t°

t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V
GSG GSG

C C C C C

PE PE PE/PEN PE PE
11
12
14
11
12
14

11
12
14
11
12
14

11
12
14

Protection Up Up Up Dimension
Model P/N Network AC system Diagram
mode L/PE L/N N/PE DIN43880
DACF25S-31-320 821410344 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.5 kV 1.5 kV 4 TE
DACF25S-31-275 821410244 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.25 kV 1.5 kV 4 TE 5
DACF25S-31-150 821410144 120/208 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 0.9 kV 1.5 kV 4 TE
DACF25S-40-440 821410424 230/400 V 3-Phase+N IT System (4+0) L/PE and N/PE 2 kV - 2 kV 4 TE
DACF25S-40-320 821410324 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.5 kV - 1.5 kV 4 TE
4
DACF25S-40-275 821410224 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.25 kV - 1.25 kV 4 TE
DACF25S-40-150 821410124 120/208 V 3-Phase+N TNS System (4+0) L/PE and N/PE 0.9 kV - 0.9 kV 4 TE
DACF25S-30-440 821410423 230/400 V 3-Phase IT System (3+0) L/PE 2 kV - - 3 TE
DACF25S-30-320 821410323 230/400 V 3-Phase TNC System (3+0) L/PE 1.5 kV - - 3 TE
3
DACF25S-30-275 821410223 230/400 V 3-Phase TNC System (3+0) L/PE 1.25 kV - - 3 TE
DACF25S-30-150 821410123 120/208 V 3-Phase TNC System (3+0) L/PE 0.9 kV - - 3 TE
DACF25S-11-320 821410342 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.5 kV 1.5 kV 2 TE
DACF25S-11-275 821410242 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.25 kV 1.5 kV 2 TE 2
DACF25S-11-150 821410142 120 V Single Phase TT-TN System (1+1) L/N and N/PE - 0.9 kV 1.5 kV 2 TE
DACF25S-20-440 821410422 230 V Single Phase IT System (2+0) L/PE and N/PE 2 kV - 2 kV 2 TE
DACF25S-20-320 821410322 230 V Single Phase TN System (2+0) L/PE and N/PE 1.5 kV - 1.5 kV 2 TE
1
DACF25S-20-275 821410222 230 V Single Phase TN System (2+0) L/PE and N/PE 1.25 kV - 1.25 kV 2 TE
DACF25S-20-150 821410122 120 V Single Phase TN System (2+0) L/PE and N/PE 0.9 kV - 0.9 kV 2 TE

29
DAC40CS SERIES
Compact 1-phase Type 2 Surge Protector

• Common/Differential mode
• Pluggable module
COMPACT
• IEC 61643‑11, EN 61643‑11 certified VERSION

• UL1449 ed.4 compliance

DAC40CS-xx-xxx
5-year
WARRANTY
Maximum operating voltage
Configuration: 11 (1+1), 20 (2+0)
«S» Remote signal
«40» Imax: 40 kA

CITEL Model DAC40CS-20-440 DAC40CS-11-275 DAC40CS-11-150


Description Compact 1-phase Type 2 surge protector - Pluggable
Network 230 V single-phase
Protection mode L/PE and N/PE L/N and N/PE L/N and N/PE
AC system IT TT-TN TT-TN
DAC40CS-20 DAC40CS-11 Max. AC operating voltage Uc 440 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) 580 Vac 335 Vac 180 Vac
UT
Charasteristic - 5 sec. withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 230 Vac
UT
Charasteristic -120mn disconnection disconnection disconnection
Temporary Over Voltage N/PE UT - 1200 V/300A/200 1200 V/300A/200
(TOV HT) ms withstand ms withstand
Residual current
Ipe < 1 mA None None
Leakage current at Uc
Follow current If None None None
Nominal discharge current
In 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 40 kA 40 kA 40 kA
max. withstand @ 8/20 µs by pole
Total discharge current - @8/20µs Itotal 80 kA 40 kA 40 kA
Up L/N - 1.25 kV 0.9 kV
Protection level @In (8/20µs) Up N/PE 1.8 kV 1.5 kV 1.5 kV
Up L/PE 1.8 kV - -
Admissible short-circuit current Isccr 10 000 A 10 000 A 10 000 A
Associated disconnectors
DAC40CS-20 DAC40CS-11 Thermal disconnector internal
Fuses 50 A min. - 125 A max. - Type gG
Existing upstream ground fault
Type "S" or delayed
breaker (if any)
Mechanical characteristics
Dimensions see diagram, 1TE (DIN43880)
by screw terminals: L/n =1.5-10mm² (16 mm²) /
Connection to Network
PE = 2.5-25mm² (35 mm² rigid)
Failsafe mode Disconnection from network
Disconnection indicator 1 mechanical indicator Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
Spare unit MDAC40C-20-440 MDAC40C-11-275 MDAC40C-11-150
Standards
V : High energy varistor network Certification KEMA
GSG : Specific Gas Tube Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
Ft : Thermal fuse Part number
C : Remote signaling contact 821510421 821520221 821520121
t° : Thermal disconnection system
MI : Disconnection indicator

30
DAC40CS SERIES
Compact 3-phase Type 2 Surge Protector

• Common/Differential mode
• Pluggable module
COMPACT
• IEC 61643‑11, EN 61643‑11 certified VERSION

• UL1449 ed.4 compliance

DAC40CS-xx-xxx
5-year
WARRANTY
Maximum operating voltage
Configuration: 40 (4+0), 31 (3+1)
«S» Remote signal
«40» Imax: 40 kA

CITEL Model DAC40CS-40-440 DAC40CS-31-275 DAC40CS-31-150


Description Compact 3-phase+N Type 2 surge protector - Pluggable
Network 230/400 V 3-phase 230/400 V 3-phase 120/208 V 3-phase
Protection mode L/PE and N/PE L/N and N/PE L/N and N/PE
AC system IT TT-TN TT-TN
Max. AC operating voltage Uc 440 Vac 275 Vac 150 Vac
DAC40CS-40 DAC40CS-31
Temporary Over Voltage (TOV) 580 Vac 335 Vac 180 Vac
UT
Charasteristic - 5 sec. withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 230 Vac
UT
Charasteristic -120mn disconnection disconnection disconnection
Temporary Over Voltage N/PE UT - 1200 V/300A/200 1200 V/300A/200
(TOV HT) ms withstand ms withstand
Residual current
Ipe < 1 mA None None
Leakage current at Uc
Follow current If None None None
Nominal discharge current
In 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 40 kA 40 kA 40 kA
max. withstand @ 8/20 µs by pole
Total discharge current @8/20µs Itotal 160 kA 40 kA 40 kA
Protection level @In (8/20µs) Up L/N - 1.25 kV 0.9 kV
Up N/PE 1.8 kV 1.5 kV 1.5 kV
Up L/PE 1.8 kV - -
Admissible short-circuit current Isccr 10000 A 10000 A 10000 A
Associated disconnectors
DAC40CS-40 DAC40CS-31 Thermal disconnector internal
Associated fuses 50 A min. - 125 A max. - Type gG
Existing upstream ground fault breaker
Type "S" or delayed
(if any)
Mechanical characteristics
Dimensions see diagram, 2 TE (DIN43880)
by screw terminals: L/N = 1.5-10mm² (16 mm²)
Connection to Network
or PE = 2.5-25mm² (35 mm² rigid)
Failsafe mode Disconnection from network
Disconnection indicator 2 mechanical indicators, Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
Spare unit MDAC40C-40-440 MDAC40C-31-275 MDAC40C-31-150
V : High energy varistor network
GSG : Specific Gas Tube Standards
Ft : Thermal fuse Certification KEMA
C : Remote signaling contact Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
t° : Thermal disconnection system Part number
MI : Disconnection indicator 821510422 821520222 821520122

31
DACF15S SERIES
Type 2 AC surge protectors with integrated fuse

• Surge protectors with Integrated Fuse (SPDI)


INTEGRATED
• Not external fuse required FUSE

• In: 5 kA
• Imax: 15 kA
• Pluggable module for each phase
• Remote signaling
5-year
• IEC 61643‑11, EN 61643‑11 certified WARRANTY
• UL1449 ed.4 compliance

CITEL Model DACF15S-10-440 DACF15S-10-320 DACF15S-10-275 DACF15S-10-150


Description Type 2 AC SPD with integrated fuse (SPDI*) - 1-pole - pluggable
Max. AC operating voltage Uc 440 Vac 320 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) 580 Vac 335 Vac 335 Vac 180 Vac

DACF15
UT
Characteristics - 5 sec. withstand withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 440 Vac 230 Vac
UT
Characteristics -120 mn disconnection disconnection disconnection disconnection
Residual current
Ipe < 1 mA < 1 mA < 1 mA < 1 mA
Leakage current at Uc
73 Follow current If None None None None
Nominal discharge currentL/N
L/N In 5 kA 5 kA 5 kA 5 kA
15 x 8/20 µs impulses

Max. discharge current


Imax 15 kA 15 kA 15 kA 15 kA
max. withstand @ 8/20 µs by pole
Withstand on combinaison waveform
F Uoc 10 kV 10 kV 10 kV 10 kV
Class test III
MI
Protection level @ In (8/20µs) Up 1.5 kV 1.2 kV 1 kV 0.6 kV
Ft
90 Admissible short-circuit current Isccr 100 000 A 100 000 A 100 000 A 100 000 A

Associated disconnectors
Thermal disconnector internal
V
Fuses internal (equivalent AC rating : 25 A, gG Type)
Existing upstream ground fault
Type "S" or delayed
breaker (if any)
C
Mechanical characteristics
7.3 Dimensions N/PE see diagram, 1 TE (DIN43880)
11
12
14

44 18 Connection to Network By screw terminals: 2.5-25 mm² (35mm² rigid)


Failsafe mode Disconnection from network
67 Disconnection indicator 1 mechanical indicator Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
L/N L/N
Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
1 2 3 Spare unit 4 MDACF15-440 MDACF15-320 5
MDACF15-275 MDACF15-150
F
L N L N L1
Standards
L2 L3 L1 L2 L3 N L1 L2 L3 N
MI Certification EAC
Ft
Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4

Part number
821310421 821310321 821310221 821310121
V
*) SPDI :SPD including all its safety devices : thermal disconnector AND electrical fuse against short circuit currents.

N/PE
11
12
14

18
V : High energy varistor network
F : Overcurrent protection (fuse)
Ft : Thermal fuse
C : Remote signaling contact
36 36
t° : Thermal disconnection system 54 72 72
MI : Disconnection indicator

3 4 5
32
LL1 N
L2 L3 L NL1 L2 L3 L1 N L2 L3 L1 L2 L1 L3 L2 N L3 N L1 L2 L3
DACF15S SERIES
Type 2 AC Multipolar surge protectors
with integrated fuse

DACF15 DACF15S-xx-xxx

73 Maximum operating voltage


L/N L/N Configuration: 10 (1+0), 11 (1+1), 20 (2+0),
30 (3+0), 40 (4+0), 31 (3+1)
«S» Remote signal
F

MI «15» Imax: 15 kA
Ft
90 t° «F» Integrated overcurrent protection (fuse)
V

7.3 N/PE
11
12
14

44 18

67

1 2 3 4 5
L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

36 36 54 72 72

L N L N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N

F
F F F F F F F F F F F F
MI MI MI
MI MI MI MI MI MI MI MI MI MI MI MI Ft
Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft Ft

t° t°

t° t° t° t° t° t° t° t° t° t° t° t°

V V V V V V V V V V V V V
GSG GSG

C C C C C

PE PE PE/PEN PE PE
11
12
14
11
12
14

11
12
14
11
12
14

11
12
14

Protection Up Up Up Dimension
Model P/N Network AC system Diagram
mode L/PE L/N N/PE DIN43880
DACF15S-31-320 - 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1.2 kV 1.5 kV 4 TE
DACF15S-31-275 821310244 230/400 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 1 kV 1.5 kV 4 TE 5
DACF15S-31-150 - 120/208 V 3-Phase+N TT-TNS System (3+1) L/N and N/PE - 0.6 kV 1.5 kV 4 TE
DACF15S-40-440 821310424 230/400 V 3-Phase+N IT System (4+0) L/PE and N/PE 1.5 kV - 1.5 kV 4 TE
DACF1S5-40-320 - 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1.2 kV - 1.5 kV 4 TE
4
DACF15S-40-275 - 230/400 V 3-Phase+N TNS System (4+0) L/PE and N/PE 1 kV - 1.5 kV 4 TE
DACF15S-40-150 - 120/208 V 3-Phase+N TNS System (4+0) L/PE et N/PE 0.6 kV - 1.5 kV 4 TE
DACF15S-30-440 821310423 230/400 V 3-Phase IT System (3+0) L/PE 1.5 kV - - 3 TE
DACF15S-30-320 - 230/400 V 3-Phase TNC System (3+0) L/PE 1.2 kV - - 3 TE
3
DACF15S-30-275 821310223 230/400 V 3-Phase TNC System (3+0) L/PE 1 kV - - 3 TE
DACF15S-30-150 - 120/208 V 3-Phase TNC System (3+0) L/PE 0.6 kV - - 3 TE
DACF15S-11-320 - 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1.2 kV 1.5 kV 2 TE
DACF15S-11-275 821310242 230 V Single Phase TT-TN System (1+1) L/N and N/PE - 1 kV 1.5 kV 2 TE 2
DACF15S-11-150 - 120 V Single Phase TT-TN System (1+1) L/N and N/PE - 0.6 kV 1.5 kV 2 TE
DACF15S-20-440 - 230 V Single Phase IT System (2+0) L/PE and N/PE 1.5 kV - 1.5 kV 2 TE
DACF15S-20-320 - 230 V Single Phase TN System (2+0) L/PE and N/PE 1.2 kV - 1.5 kV 2 TE
1
DACF15S-20-275 - 230 V Single Phase TN System (2+0) L/PE and N/PE 1 kV - 1.5 kV 2 TE
DACF15S-20-150 - 120 V Single Phase TN System (2+0) L/PE and N/PE 0.9 kV - 0.9 kV 2 TE

33
DAC15CS SERIES
Compact 1-phase Type 2 (or 3) Surge Protector

• Common/Differential mode
• Pluggable module
COMPACT
• IEC 61643‑11, EN 61643‑11 certified VERSION

• UL1449 ed.4 compliance

DAC15CS-xx-xxx 5-year
WARRANTY
Maximum operating voltage
Configuration: 11 (1+1), 20 (2+0)
«S» Remote signal
«15» Imax: 15 kA

CITEL Model DAC15CS-20-440 DAC15CS-11-275 DAC15CS-11-150


Description Compact 1-phaseType 2 surge protector - Pluggable
230/400 V 230/400 V 120/208 V
Network
single-phase single-phase single-phase
Protection mode L/PE and N/PE L/N and N/PE L/N and N/PE
AC system IT TT-TN TT-TN
DAC15CS-20 DAC15CS-11
Max. AC operating voltage Uc 440 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) 580 Vac 335 Vac 180 Vac
UT
Charasteristic 5 sec. withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 230 Vac
UT
Charasteristic 120 mn disconnection disconnection disconnection
Temporary Over Voltage N/PE 1200 V/300A/ 1200 V/300A/
UT -
(TOV HT) 200 ms withstand 200 ms withstand
Residual current
Ipe < 1 mA None None
Leakage current at Uc
Follow current If None None None
Nominal discharge current
In 5 kA 5 kA 5 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 15 kA 15 kA 15 kA
max. withstand @ 8/20 µs by pole
Total discharge current @ 8/20µs Itotal 30 kA 30 kA 30 kA
Withstand on combinaison
Uoc 10 kV 10 kV 10 kV
waveform Class III test
Up L/N - 1 kV 0.6 kV
Protection level @ In (8/20µs) Up N/PE 1.5 kV 1.5 kV 1.5kV
Up L/PE 1.5 kV - -
DAC15CS-20 DAC15CS-11 Admissible short-circuit current Isccr 10000 A 10000 A 10000 A
Associated disconnectors
Thermal disconnector internal
Fuses 20 A min - 125 A max. - Type gG
Existing upstream ground fault breaker
Type "S" or delayed
(if any)
Mechanical characteristics
Dimensions see diagram, 1 TE (DIN43880)
by screw terminals: L/N = 1.5-10 mm² (16mm²)
Connection to Network
or PE = 2.5-25 mm² (35 mm² rigid)
Failsafe mode Disconnection from network
Disconnection indicator 1 mechanical indicators, Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
V : High energy varistor network Protection rating IP20
GSG : Specific Gas Tube Housing material Thermoplastic UL94 V-0
Ft : Thermal fuse Spare unit MDAC15C-20-440 MDAC15C-11-275 MDAC15C-11-150
C : Remote signaling contact Standards
t° : Thermal disconnection system
Certification KEMA
MI : Disconnection indicator
Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
Part number
821610421 821620221 821620121

34
DAC15CS SERIES
Compact 3-phase Type 2 (or 3) Surge Protector

• Common/Differential mode
• Pluggable module
COMPACT
• IEC 61643‑11, EN 61643‑11 certified VERSION

• UL1449 ed.4 compliance

DAC15CS-xx-xxx 5-year
WARRANTY
Maximum operating voltage
Configuration: 40 (4+0), 31 (3+1)
«S» Remote signal
«15» Imax: 15 kA

CITEL Model DAC15CS-40-440 DAC15CS-31-275 DAC15CS-31-150


Description Compact 3-phase+N Type 2 surge protector - Pluggable
Network 230/400 V 3-phase 230/400 V 3-phase 120/208 V 3-phase
Protection mode L/PE and N/PE L/N and N/PE L/N and N/PE
AC system IT TT-TN TT-TN
DAC15CS-40 DAC15CS-31 Max. AC operating voltage Uc 440 Vac 275 Vac 150 Vac
Temporary Over Voltage (TOV) 580 Vac 335 Vac 180 Vac
UT
Charasteristic - 5 sec. withstand withstand withstand
Temporary Over Voltage (TOV) 770 Vac 440 Vac 230 Vac
UT
Charasteristic -120 mn disconnection disconnection disconnection
Temporary Over Voltage N/PE 1200 V/300A/200 1200 V/300A/200
UT -
(TOV HT) ms withstand ms withstand
Residual current
Ipe < 1 mA None None
Leakage current at Uc
Follow current If None None None
Nominal discharge current
In 5 kA 5 kA 5 kA
15 x 8/20 µs impulses
Max. discharge current
Imax 15 kA 15 kA 15 kA
max. withstand @ 8/20 µs by pole
Total discharge current - @ 8/20 µs Itotal 60 kA 40 kA 40 kA
Withstand on combinaison
Uoc 10 kV 10 kV 10 kV
waveform Class III test
Up L/N - 0.9 kV 0.6 kV
Protection level @ In (8/20µs) Up N/PE 1.5 kV 1.5 kV 1.5kV
Up L/PE 1.5 kV - -
Admissible short-circuit current Isccr 10000 A 10000 A 10000 A
DAC15CS-40 DAC15CS-31
Associated disconnectors
Thermal disconnector internal
Fuses 20 A min. - 125 A max. - Type gG
Existing upstream ground fault breaker
Type "S" or delayed
(if any)
Mechanical characteristics
Dimensions see diagram, 2 TE (DIN43880)
by screw terminals: L/N: 1.5-10mm² (16mm²)
Connection to Network
or PE: 2.5-25mm² (35mm² rigid)
Failsafe mode Disconnection from network
Disconnection indicator 2 mechanical indicators, Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
V : High energy varistor network
GSG : Specific Gas Tube Housing material Thermoplastic UL94 V-0
Ft : Thermal fuse Spare unit MDAC15C-40-440 MDAC15C-31-275 MDAC15C-31-150
C : Remote signaling contact Standards
t° : Thermal disconnection system Certification KEMA
MI : Disconnection indicator Compliance IEC 61643-11 / NF EN 61643-11 / UL1449 ed.4
Part number
821610422 821620222 821620122

35
DACN10S SERIES
1-phase Type 2 (or 3 ) AC surge protector

• Cost effective Single phase Surge Protector


COMPACT
• Type 2 or Type 3, Monobloc VERSION
• 2-port configuration (series mounting)
• In: 5 kA
• Imax: 10 kA
• Load current 25 A
5-year
• Remote signaling WARRANTY
• IEC 61643-11 compliance

DACN10S-11-150 DACN10S-11-275 DACN10S-21YG-275 DACN10S-20-150 DACN10S-20-275 DACN10S-20-440


CITEL Model
DACN10S-L11-150 DACN10S-L11-275 DACN10S-L21YG-275
Description Type 2 or Type 3, 2-port AC single phase surge protector
Network 120 Vac 230 Vac 230 Vac 120 Vac 230 Vac 230 Vac
Protection mode L/N and N/PE L/N and N/PE L/N and N/PE L/PE and N/PE L/PE and N/PE L/PE and N/PE
AC system TT-TN TT-TN TN TN TN TN-IT
Max. AC operating voltage Uc 150 Vac 275 Vac 275 Vac 150 Vac 275 Vac 440 Vac
Temporary Over Voltage (TOV) UT
180 Vac withstand 335 Vac withstand 335 Vac withstand 180 Vac withstand 335 Vac withstand 580 Vac withstand
characteristics - 5 sec.
Temporary Over Voltage (TOV) UT 230 Vac 440 Vac 440 Vac 230 Vac 230 Vac 770 Vac
characteristics - 120mn disconnection disconnection disconnection disconnection disconnection disconnection
Temporary Over Voltage N/PE UT 1200 V/300A/ 1200 V/300A/ 1200 V/300A/ 1200 V/300A/
- -
(TOV HT) 200 ms withstand 200 ms withstand 200 ms withstand 200 ms withstand
Residual current Leakage current at Uc Ipe none none none < 1 mA < 1 mA < 1 mA
Max. Load current IL 25 A 25 A 25 A
25 A 25 A 25 A
16 A 16 A 16 A
Follow current If none none none none none none
Nominal discharge current In
5 kA 5 kA 5 kA 5 kA 5 kA 5 kA
15 x 8/20 µs impulses
Max. discharge current Imax
10 kA 10 kA 10 kA 10 kA 10 kA 10 kA
max. withstand @ 8/20 µs by pole
Withstand on Combination Uoc
10 kV 10 kV 10 kV 10 kV 10 kV 10 kV
waveform - Class III test
Up L/N 0,7 kV 1,1 kV 1,3 kV - - -
Protection level @In (8/20µs) Up N/PE 1,5 kV 1,5 kV 1,6 kV 0,7 kV 1,1 kV 1,6 kV
Up L/PE - - 1,6 kV 0,7 kV 1,1 kV 1,6 kV
Admissible short-circuit current Isccr 10 000 A 10 000 A 10 000 A 10 000 A 10 000 A 10 000 A
Associated disconnectors
Thermal disconnector internal
Fuses Fuses type gG - 25 A
Installation ground fault breaker Type «S» or delayed
(if any)
Mechnical characteristics
Dimensions see diagram, 1TE (DIN43880)
Connection to Network by screw terminals: 1.5-10 mm²
Failsafe behavior Disconnection SPD (DACN10) - Disconnection SPD + AC line cut off (DACN10L)
Disconnection indicator Green LED off
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/2 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94 V-0
Standards
Compliance IEC 61643-11 / EN 61643-11 / UL1449 ed.4
Part number
70111012 70111022 70114022 70113012 70113022 70113032
70112012 70112022 -

36
DACN10 SERIES
73.5

Nin Lin
DACN10
DACN10S-L xx-xxx

90operating voltage
Max
Configuration : 11 (1+1), 20 (2+0), or 21YG (Y diagram)
« » = parallel disconnection in case of failure
«L» = In-line disconnection in case of failure
«S» = Remote signal
Imax : 10 kA
Non pluggable
Nout Lout

8.8
18

73.5

DACN10-11-xxx

Nin Lin
DACN10-20-xxx

Nin Lin
DACN10-21YG-275
Nin

Nin
Lin

Lin
DACN10-L11-xxx

Nin Lin
DACN10-L21YG-275

Nin Lin
DACN10
Led
Ft Led
Led Led
Ft Ft Ft Ft
Led Ft Ft Ft
90 t°
t° t° t° t°
t° t° t°

V V V V
V V V V
GSG GSG

GSG GSG
Nout Lout
Nout Lout Nout Lout Nout Lout Nout Lout Nout Lout
8.8
18

DACN10S-11-xxx DACN10S-20-xxx DACN10S-21YG-275 DACN10S-L11-xxx DACN10S-L21YG-275


DACN10-11-xxx DACN10-20-xxx DACN10-21YG-275 DACN10-L11-xxx DACN10-L21YG-275
Nin Lin Nin Lin Nin Lin Nin Lin Nin Lin
Nin Lin Nin Lin Nin Lin Nin Lin Nin Lin
Led
Ft Led
Led Led
Ft Led Ft Ft Ft Led Ft
Ft Ft Led Ft Led
Led Ft Ft Ft Ft
Led Ft Ft Ft t°
t° t° t° t°
t° t° t° t°
t° t° t° t°
t° t° t° V V V V
V V V V
V V V V
GSG V V GSG V
V
GSG GSG
GSG GSG

GSG GSG
Nout Lout Nout Lout Nout Lout Nout Lout Nout Lout
Nout Lout Nout Lout Nout Lout Nout Lout Nout Lout
C C C C C
11
12
11
12

11
12

11
12

11
12
NC

NC

NC

NC

V: MOV
DACN10S-11-xxx
GSG: Specific GDT
DACN10S-20-xxx DACN10S-21YG-275 DACN10S-L11-xxx DACN10S-L21YG-275
F : Thermal fuse
Nin Ldisconnection
t°: Thermal in Nin
mechanismLin Nin Lin Nin Lin Nin Lin
LED: Disconnector indicator
C: Remote signaling contact Led
Ft Led
Led Led
Ft Ft Ft Ft
Led Ft Ft Ft

t° t° t° t°
t° t° t°

V V V
V V
V
V V
37
GSG GSG
DC POWER SURGE PROTECTORS

Type 1 and Type 2


DDCxxS series
• Type 1+2 or Type 2 pluggable surge protectors designed
for equipment connected to DC powerlines.

• One or Two-pole unit.

• Technology based on high energy varistor equipped


with thermal disconnection mechanism.

• Remote disconnection signaling feature.

• prIEC61643-41 compliance (forthcoming standard for


DC power SPD).

Type 2 compact
DDxxCS series
• Type 2 pluggable surge protectors designed for equip-
ment connected to DC powerlines.

• Compact design to fit inside small cabinets.

• Remote disconnection signaling feature.

• prIEC61643-41 compliance (forthcoming standard for


DC power SPD).

• Available for DC powerline from 12 to 350 Vdc.

38
DDC30S SERIES
Type 1 (or )2 DC power Surge Protectors

• 1-pole or 2-pole surge protector • Remote signaling


• In: 15 kA / Imax: 30 kA • prIEC 61643-41 compliance DC VERSION

• Iimp: 4 kA
• Pluggable module

DDC30S-x0-xx
5-year
WARRANTY
Max. DC operating voltage
Number of protected pole (1 or 2)
«S» = Remote signal
Imax : 30 kA

CITEL Model DDC30S-10-65 DDC30S-10-85 DDC30S-20-65 DDC30S-20-85


Description 1-pole DC surge protector 2-pole DC surge protector
Nominal DC voltage Un 48 Vdc 75 Vdc 48 Vdc 75 Vdc
Connection mode +/PE and -/PE +/PE and -/PE +/PE and -/PE +/PE and -/PE
DDC30 Max. DC operating voltage Uc-DC 65 Vdc 85 Vdc 65 Vdc 85 Vdc
DDC30S-10 DDC30S-20 Max. AC operating voltage Uc-AC 50 Vac 60 Vac 50 Vac 60 Vac
73 Residual current
Ipe < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA
Leakage current
+/- at Uc +/- -/+
+/- +/- -/+
Follow current If None None None None
Nominal discharge current
In 15 kA 15 kA 15 kA 15 kA
15 x 8/20MIµs impulses MI MI
Max. discharge
Ft current Ft Ft Imax 30 kA 30 kA 30 kA 30 kA
max. withstand @ 8/20 µs by pole
90

t° t° Imax
Total discharge current @ 8/20µs 60 kA 60 kA 60 kA 60 kA
total
Max. lightningV current by pole
V V
Iimp 4 kA 4 kA 4 kA 4 kA
max. withstand @ 10/350µs
Protection level +/PE C(/-PE)
C Up 300 V 390 V 300 V 390 V
@ In (8/20µs)
Protection PE
Level +/- @In (8/20µs)PE Up - - 600 V 780 V
11
12
14

11
12
14

7.3
44 18 36 Associated disconnectors
67 Thermal disconnector internal
Fuses (if requested) 50 A min. - 125 A max. -Fuses type gG
Mechanical characteristics
Dimensions see diagram - 1 TE (EN43880) see diagram - 2 TE (EN43880)
Connection to Network Screw terminals: 2.5-25 mm² +/- : 1.5-10 mm²
Failsafe mode Disconnection from network
Disconnection indicator 1 mechanical indicator Green/Red 2 mechancial indicators Green/Red
DDC30S-10 DDC30S-20 Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
-/+
+/- +/- -/+ Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
MI MI MI Housing material Thermoplastic UL94-V0
Ft Ft Ft Spare unit MDDC30-65 MDDC30-85 MDDC30-65 MDDC30-85
Standards

t° t° Compliance prIEC 61643-41
Part number
V V V
828110121 828110221 828110122 828110222

C C

PE PE
11
12
14
11
12
14

36
V : High energy varistor network
Ft : Thermal fuse
C : Remote signaling contact
t° : Thermal disconnection system
MI : Disconnection indicator

39
DDC50S-21Y SERIES
Type 2 DC power Surge Protectors
• DC power Type 2 SPD
• for Energy Storage System/EV Charging
• up to 1200 V DC voltage DC VERSION
• In/Imax: 20/50 kA
• Pluggable modules
• Remote signaling
• prIEC 61643-41 compliance
5-year
DDC50S-21Y-xxx WARRANTY

Max. DC operating voltage

Internal diagram

«S» = Remote signal

Imax : 50 kA

CITEL Model DDC50S-21Y-500 DDC50S-21Y-800 DDC50S-21Y-1200 DDC50S-21Y-1500


Description DC power surge protector
Nominal DC voltage Un 450 Vdc 650 Vdc 1000 Vdc 1200 Vdc

DDC50 Max. DC operating voltage


Residual current
Uc
Ipe
500 Vdc
< 0.1 mA
800 Vdc
< 0.1 mA
1200 Vdc
< 0.1 mA
1500 Vdc
< 0.1 mA
Leakage current at Uc
73 Nominal discharge current
In 20 kA 20 kA 20 kA 20 kA
15 x 8/20 µs impulses
+/- -/+
+/- -/+ Max. discharge current
Imax 50 kA 50 kA 50 kA 50 kA
max. withstand @ 8/20 µs by pole
Max. lightning current by pole
Iimp 4 kA 4 kA 4 kA 4 kA
max.
MI withstand
MI @ 10/350µsMI
Protection
Ft level +/PE
Ft (-/PE)Ft
Up 2.1 kV 2.7 kV 3.6 kV 5.1 kV
@ In (8/20µs)

90 Protection
t° level
t° @ In (8/20µs)
t° +/- Up 2.1 kV 2.7 kV 3.6 kV 5.1 kV
Admissible Short circuit current Isccr 100 000 A 100 000 A 100 000A 100 000 A
V V V
Associated disconnectors
Thermal disconnector internal
Fuses
C 50 A min. (Isccr 100 kA)- 125 A max. (Isccr 50 kA) - High voltag DC Fuses
Mechanical characteristics
PE
11
12
14

7.3 Dimensions see diagram - 3 TE (EN43880)


44 54 Connection to Network Screw terminals: 2.5-25 mm²
67 Failsafe mode Disconnection from network
Disconnection indicator 3 mechanical indicators Green/Red
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
Wiring for remote signaling Max. 1.5 mm²
Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
+/- -/+ Housing material Thermoplastic UL94-V0
+/- -/+
Spare unit MDDC50-500 MDDC50-800 MDDC50-1200 MDDC50-1500
Standards
MI MI MI
Compliance prIEC 61643-41
Ft Ft Ft
Part number
t° t° t°
828511263 828511363 828511563 828511663

V V V

PE
11
12
14

54
V: High-energy varistor
Ft: Thermal fuse
C: Remote signaling contact
t°: Thermal disconnection system
Mi : Disconnection indicator

40
DDCNXXS SERIES
Type 2 (or 3) DC power Surge Protectors
• SPD for 24 or 48 V DC
• Series Connection (2-port)
DC VERSION
• In : 15 kA / Imax : 30 kA
• Monobloc
• Remote signaling
• prIEC 61643-41 compliance
5-year
DDCNxxS-x21YG-xx WARRANTY

Max operating DC voltage.

“ “ : parallel disconnection / “L” : series disconnection

«S» = Remote signaling

Imax

CITEL Model DDCN03S-21YG-30 DDCN06S-21YG-65


Description Type 2 (ou 3) , 2-port DC powr SPD

DDCN10 Nominal DC voltage


Connection mode
Maximal operating voltage.
Un

Uc
24 Vdc
+/-/PE
30 Vdc
48 Vdc
+/-/PE
65 Vdc
Max load current IL 25 A 25 A
73.5 Residual current
Ipe none none
Leakage current @ Uc
- IN +
Nominal discharge current
In 1.5 kA 2 kA
15 x 8/20 µs impulses
DDCN10 Max. discharge current
max. withstand @ 8/20 µs by pole
Imax 3 kA 6 kA
Whithstand in combination wave-
73.5 Uoc 3 kV 4 kV
form - Classe III Test
- IN + Protection level +/-
90 Up 0.2 kV 0.5 kV
@ In (8/20µs)
Protection level +/PE (or -/PE)
Up 0.8 kV 0.8 kV
@ In (8/20µs)
90 Associated disconnectors
Thermal disconnector internal
- OUT +
Fuses (if resqueted) 25 A type gG
8.8 Mechnical characteristics
- OUT + Dimensions see diagram , 1 TE (EN43880)
8.8
18
18 Connection to Network by screw 1.5-10 mm²
Failure mode Disconnection
DDCN*-21YG-*
DDCN*-21YG-* DDCN*-L21YG-*
DDCN*-L21YG-* Operation indication Green indicator ON
- - Disconnection indication Green indicator OFF
- + +
-
IN IN
IN + IN +
Parallel Disconnection Mode DDCN03-21YG-30 DDCN06-21YG-65
Led Led
Mode de déconnexion série
Ft
Led
Ft Ft Ft
Led DDCN03-L21YG-30 DDCN06-L21YG-65
Coupure du réseau AC
Ft
t° t° Ft t° t° Ft Ft avec Télésignalisation de défaut DDCN03S-21YG-30 DDCN06S-21YG-65
V V V V sortie sur contact NC DDCN03S-L21YG-30 DDCN06S-L21YG-65
t° t° t° t° Max. Voltage/current for Remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
GSG GSG Remote signaling wiring max. 1.5 mm²
V V V V
- OUT + - OUT + Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
GSG GSG
Protection rating IP20
DDCN*S-21YG-* DDCN*S-L21YG-*
Housing material Thermoplastic UL94-V0
--
OUT + - - OUT +
+ +
Standards
IN IN

Led Led Compliance IEC 61643-11, prIEC 61643-41


Ft Ft Ft Ft
Part Number
t° t° t° t° DDCN03-21YG-30 DDCN06-21YG-65
DDCN*S-L21YG-*
Standard Version
DDCN*S-21YG-*
V V V V
70124041 70134051
DDCN03-L21YG-30 DDCN06-L21YG-65
- IN + - IN + Series disconnection Version
GSG GSG 70125041 70135051
- OUT + - OUT + DDCN03S-21YG-30 DDCN06S-21YG-65
Led Led
Remote signaling Version
Ft C Ft C Ft Ft 70124042 70134052
DDCN03S-L21YG-30 DDCN06S-L21YG-65
11
12
11
12
NC

Remote signaling& Series disconnection


t° t° t° t°
V: Varistor
Version 70125042 70135052
GSG : Specific
V V Gas Tube V V
Ft: Thermal fuse
t°: Thermal disconnection system
LED : Disconnection indicator
CGSG
: Remote signaling contact GSG
41
- OUT + - OUT +
DDCxxCS SERIES
Type 2 Compact DC power Surge Protectors

• Type 2 DC power surge protectors


• From 12 to 350 Vdc DC network
• Imax: 20, 30 and 40 kA
• Compact Design
• Pluggable module
• Remote signaling
• prIEC 61643-41 compliance
• IEC 61643-31 compliance

CITEL Model DDC20CS-20-24 DDC20CS-20-38 DDC30CS-20-65


Network 12Vdc 24Vdc 48 Vdc
Connection mode +/-/PE +/-/PE +/-/PE
Max. DC operating voltage Uc 24 Vdc 38 Vdc 65 Vdc

DDCx0C
Max. AC operating voltage Uc 20 Vac 30 Vac 50 Vac
Max. operating voltage PV-DC Ucpv 24 Vdc 38 Vdc 65 Vdc
Permanent operating current @ Ucpv Icpv < 0.1 mA < 0.1 mA < 0.1 mA
Residual current
Ipe < 0.1 mA < 0.1 mA < 0.1 mA
Leakage current at Uc
Follow current If None None None
73.5
Nominal discharge current
In 10 kA 10 kA 15 kA
15 x 8/20 µs impulses
+ - Max. discharge current
Imax 20 kA 20 kA 30 kA
+ pole -
max. withstand @ 8/20 µs by
Imax-
Total discharge current @ 8/20µs 40 kA 40 kA 60 kA
total
Protection level +/PE (-/PE) @ In (8/20µs) Up 250 V 250 V 300 V
Protection level +/-
MI@( (8/20µs)
Ft Ft Up 500 V 500 V 600 V
Admissible short circuit current Isccr 10 000 A 10 000 A 10 000 A
90
Current withstand short

circuit

PV Iscpv 1000 A 1000 A 1000 A
Associated disconnectors
Thermal disconnectorV V internal
Fuses (if required) 20 A min - 125 A max - Type gG
Mechanical characteristics
C
Dimensions see diagram, 1 TE (EN43880)
by screw terminals: 1.5-10mm² (actives wires)
Connection to Network PE
11
12
14

8.8 and 2.5-25mm² (ground)


18 Disconnection indicator 1 mechanical indicator, Green/Red
Failure mode Disconnection from network
Max. voltage/current for remote signaling 250 V/0.5 A (AC) / 30 V/3 A (DC)
+ - Wiring for remote signaling Max. 1.5 mm²
+ - Mounting Symmetrical rail 35 mm (EN60715)
Operating temperature -40/+85°C
Protection rating IP20
Housing material Thermoplastic UL94-V0
MI
Spare unit MDDC20C-20-24 MDDC20C-20-38 MDDC30C-20-65
Ft Ft
Standards
Compliance prIEC61643-41/ UL1449 ed.4
t° t° Part number
828210321 828210421 828310121
V V
V : High energy varistor network
Ft : Thermal fuse
C : Remote signaling contact
C
t° : Thermal disconnection system
MI : Disconnection indicator
PE
11
12
14

18

42
DC VERSION

DDCxxCS-20-xx

Maximum DC operating voltage COMPACT


VERSION
Configuration: 20 (2+0)
«S» Remote signal

5-year
«C» Compact
«30» Imax: 20kA, 30 kA or 40 kA

WARRANTY

DDC40CS-20-100 DDC40CS-20-125 DDC40CS-20-150 DDC40CS-20-180 DDC40CS-20-275 DDC40CS-20-350 DDC40CS-20-460


75 Vdc 95 Vdc 110 Vdc 130 Vdc 220 Vdc 280 Vdc 350 Vdc
+/-/PE +/-/PE +/-/PE +/-/PE +/-/PE +/-/PE +/-/PE
100 Vdc 125 Vdc 150 Vdc 180 Vdc 275 Vdc 350 Vdc 460 Vdc
75 Vac 95 Vac 115 Vac 150 Vac 210 Vac 275 Vac 350 Vac
100 Vdc 125 Vdc 150 Vdc 180 Vdc 275 Vdc 350 Vdc 460 Vdc
< 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA
< 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA < 0.1 mA
None None None None None None None
20 kA 20 kA 20 kA 20 kA 20 kA 20 kA 20 kA

40 kA 40 kA 40 kA 40 kA 40 kA 40 kA 40 kA

80 kA 80 kA 80 kA 80 kA 80 kA 80 kA 80 kA

390 V 450 V 500 V 620 V 900 V 1200 V 1400 V


780 V 900 V 1000 V 1200 V 1800 V 2400 V 2800 V
10 000 A 10 000 A 10 000 A 10 000 A 10 000 A 10 000 A 10 000 A
1000 A 1000 A 1000 A 1000 A 1000 A 1000 A 1000 A

50 A min. - 125 A max. - Type gG

MDDC40C-20-100 MDDC40C-20-125 MDDC40C-20-150 MDDC40C-20-180 MDDC40C-20-275 MDDC40C-20-350 MDDC40C-20-460

828410521 828410621 828410721 828410821 828410921 828411021 828411121

43
SELECTION OF SPD
Selection of SPDs in relation
Following
IEC 60364-4-443 and
IEC 60364-5-534
Installation in the main distribution panel (3-Phase 230/400 Vac)

LPL I or II DS254VG-300/G DS253VG-400


- 3-Phase + N - 3-Phase
- TN or TT systems - IT systems
- Type 1+2+3 - Type 1+2+3
Installation - Iimp 25 kA/pole - Iimp 25 kA/pole
with LPS - VG-Technology - VG-Technology

DAC1-13VGS-31-275 DAC1-13S-30-440
- 3-Phase + N - 3-Phase
- TN or TT systems - IT systems
- Type 1+2+3 - Type 1+2
- Iimp 12.5 kA/pole - Iimp 12.5 kA/pole
- VG-Technology - Pluggable
LPL III or IV - Pluggable

OR

DAC80S-31-275 DAC80S-30-440
Reinforced
- 3-Phase + N - 3-Phase
- TNS or TT systems - IT system
- Type 2 - Type 2
- Imax 80 kA - Imax 80 kA
- Pluggable - Pluggable

Installation
without LPS DAC50VGS-31-275 DAC50S-30-440
- 3-Phase + N
- TN or TT systems - 3-Phase
- Type 2+3 - IT system
- Imax 50 kA - Type 2
- VG-Technology - Imax 50 kA
- Pluggable - Pluggable

Standard

44
FOR AC POWERLINE
with their location and the international standard

Installation in AC Sub-Panel and/or close to the equipment

DAC50S-31-275 DAC50S-11-275
Standard
- 3-Phase + N - Single-phase
- TN/TNS systems - TT/TN systems
- Type 2 or
- Type 2
- Imax 50 kA - Imax 50 kA
- Pluggable - Pluggable
Sentitive equip-
ment >10 m from
the primary SPD DACF25S-31-275 DACF25S-11-275
- 3-Phase + N - Single-phase
- TN/TNS systems - TT/TN systems
- Type 2
or - Type 2
- Imax 50 kA - Imax 50 kA
With integrated - Pluggable - Pluggable
fuse

DAC40CS-31-275 DAC40CS-11-275
Compact - Compact SPD or - Compact SPD
- 3-Phase + N - 3-Phase + N
- TN or TT systems - TN or TT systems
- Type 2 - Type 2
No additional - Imax 40 kA - Imax 40 kA
SPD required - Pluggable - Pluggable

DACF15S-11-275
- Integrated fuse
- 3-Phase + N
With integrated fuse - TT/TN systems
- Type 2 (or 3)
- Imax 15 kA
- Pluggable

DAC15CS-11-275
- Compact SPD
Sentitive Compact - Single-phase
equipment >10 m - TT/TN systems
from the primary - Type 2 (or 3)
SPD - Imax 15 kA
- Pluggable

DACN10S-11-275
- Monobloc
- Single-phase
- TN or TT systems
Monobloc / - Type 2 (or 3)
series mounting - In 5 kA
- Imax 10kA

45
France China Thailand
Head Office Office Bangkok
Sales department Shanghai Tel. : +66 (0) 2 104 9214
Sèvres Tel. : +86 21 58 12 25 25 Web : www.citel.fr
Tel. : +33 1 41 23 50 23 e-mail : info@citelsh.com
e-mail : contact@citel.fr
Web : www.citel.fr
Web : www.citel.cn
U.A.E
Dubaï
Factory
Web : www.citel.fr
Factory Tel. : +86 21 58 12 80 67
Reims
Tel. : +33 3 26 85 74 00
e-mail : contact@citel.fr
Russia
Moscow
Tel. : +7 499 391 47 64
Germany e-mail : info@citel.ru
Bochum Web : www.citel.ru
Tel. : +49 2327 6057 0
e-mail : info@citel.de
Web : www.citel.de
India
New Delhi
Tel. : +91 11 4001 81 31

USA e-mail : indiacitel@gmail.com


Web : www.citel.in
Miramar
Tel : (954) 430 6310
e-mail : info@citel.us
Web site : www.citel.us

2021/08
BR190301D

You might also like