RHP1P2-BW-TGC-4TV-00-WI-EL-00005

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

WORK INSPECTION REQUEST - WIR

Construction of Townhouses & semi-detached Villas


Project Name
(412) for Phase 1B & 1C WIR Ref.No: RHP1P2-BW-TGC-4TV-00-WI-EL-00005

Contract No
Request Submission
Employer Reem Hills Sole-Proprietorship LLC 19-Jun-24
(Date & Time)
PMC Royal Development Company Inspection 20-Jun-24
PMC Royal Architect Project Management (Date & Time ) 04:00PM
Engineer AECOM Middle East LLC Rev No: 0
Main Contractor Trojan General Contracting LLC WIR Submitted By: M/s.TROJAN

MEP Contractor Royal Advance Electro Mechanical Works LLC WIR Submitted To: Consultant-AECOM

Part A: By the Contractor:


B.O.Q Ref: N/A Discipline:
B.O.Q. Description of Works to be inspected and / or tested: General MCC Works
Civil Landscaping
Storm Water Architectural
Description of Works to be inspected and /or tested: Sewer Dredging
Water Highway Bridge Works
Irrigation LRT Bridge Works
Inspection Request for Installation of Under Ground Electrical Telephone MSE Wall
Signal Works Provisional Sum
Duct pipes, As per Attached Drawing
Electrical Other (state)
Street Lighting
Works Location: Villa-366, 4BR (Mirror) Landscape Lighting Drainage

Works Quantity: Gas Network

Drawing attached to show the location(s) Yes No Checklist attached Yes No


Attached Test Certificates Yes No

Shop Drawing Ref: RHP1P2-BW-TGC-4TV-FN-SD-EL-00001-Rev-01 Method Statement Ref: RHP1P2-BW-TGC-ZZ-XX-MS-EL-00001

Type of Attachment: Check list ITP Ref: ITP-01 Rev.02

Eng. Dayal Pushpakumar


(QA/QC Manager )

Date & Signature


Part B: By the Engineer:
Received by Engineer on: Date: Time: Signed by:
Engineer's Comments:

Name: Date & Signature


Discipline Engineer Decision:
A - Approved

B - Approved with comments

C - Revise & Resubmit

D - Rejected

Sr.Resident Engineer / Resident Engineer :

Name : Suheib Aboamir


Date & Signature
CONSTRUCTION OF TOWNHOUSES & SEMI-DETACHED VILLAS (412) FOR
:
Project PHASE 1B & 1C

Employer : Reem Hills Sole Properietorship LLC

Royal Development Company and


Employer Project Manager :
Rapm Architect Project Management

Consultant : Aecom Middle East – Abu Dhabi

Main Contractor : Trojan General Contracting LLC

MEP Contractor : Royal Advance Electro Mechanical Works LLC

CHECKLIST FOR THE INSTALLATION OF UNDERGROUND UPVC DUCT PIPE & ACCESSORIES
MS-Reference Number- RHP1P2-BW-TGC-ZZ-XX-MS-EL-00001
WIR NO.RHP1P2-BW-TGC-4TV-00-WI-EL-00005 Location: Villa-366, 4BR (Mirror) Date:19-06-2024

Checked by Checked by

SN Items to be checked Contractor Consultant Remarks

N/A

N/A
Yes

Yes
No

No
HSE Requirements

1 All the HSE requirements are fulfilled.

QA/QC Requirements
Check the site is well coordinated follow approved MEP
1 Yes
coordination Drawing.
Check the material used is as per specifications/approved material
2 Yes
submittal

3 Check the sizes of the duct pipes as per drawing Yes

4 Location are checked as per approved drawings. Yes

5 Check the Duct pipes are supported and fixed properly Yes

6 Check all the damaged Duct pipes and sleeves are replaced Yes

7 Check all ducts having pulling ropes. N/A

Check Duct pipe ends are closed and all the pipes and sleeves are
8 Yes
properly protected to avoid damages and blockages.

For Final Approval


MEP Contractor Engineer MEP QA/QC Engineer Consultant Representative

Name: Eng. Vivek Name: Eng. Waqar younas Name:

Signature: Signature: Signature:

Date: 19/06/2024 Date: 19/06/2024 Date:

TGC/QAQC/CHK/MEP/ELECT-01 REV-00 Page 1 of 1


KEYPLAN:

1 2 3 N

WL12
WL12

WL12 WL12

WL12
J.B General Notes:
E 1. ALL DIMENSIONS ARE IN MILLIMETERS AND COORDINATES
ARE IN METERS UNLESS STATED OTHERWISE.
2. DO NOT SCALE FROM THE DRAWING.

FFL +0.15m
SSL +0.070m
WL12 Living +
Dining

REFERENCE DRAWINGS

Rev. Drawing Number

00 REH-KEO-4TVM-00-DR-ARC-01003
00 REH-KEO-4TVM-ZZ-DR-STR-10001
00 REH-KEO-4TVM-00-DR-EPR-10100
D SSL +0.070 SSL +0.070
WL12 REVISIONS

C 7 8 9 01 14.06.2024 ISSUED FOR APPROVAL


Kitchen FFL +0.15m 00 20.05.2024 ISSUED FOR APPROVAL
SSL +0.070m 1 2 3 4 5 6 Rev. Sub.Date Description Approval
10
Corridor Status
MASTER DEVELOPER DEVELOPER CLIENT
Storage
20 19 18 17 16 15 14 13 11
WL12

12
DB-4TVM-01

B BELL PROJECT MANAGEMENT DEVELOPER


CONSULTANT
SECTION A
FACP

REPRESENTATIVE
AECOM MIDDLE EAST LIMITED - ABU DHABI

SECTION 1:20 P. O. BOX 53 INTERNATIONAL TOWER CAPITAL GATE


ABU DHABI, UAE
SSL +0.070m

TEL: +971 2 613 4000


FFL +0.15m

Foyer WC
SMDB WC
ONU
Contractor :
468

600
J.B

WL12
TROJAN GENERAL CONTRACTING LLC
PO Box 111059, Abu Dhabi, UAE
T: +97125097300 | F: +97125097301

Bedroom 04 MEP Contractor :

FFL +0.15m FFL +0.15m


Royal Advance Electromechanical Works LLC
SSL +0.070m SSL +0.070m
A A P.O Box 111059
Tel:+971 2 509 7300
Fax:+971 2 509 7301
Abu Dhabi - U.A.E
info@royaladvance.ae

WL12

AECOM CONSULTANT STATUS


A
EARTH PIT

S10 S10 S10

J.B J.B

WL12

Drawing Status CONSTRUCTION SHOP DRAWINGS


300 SSL -3.750
Project
REEM HILLS DEVELOPMENT
LUXURY VILLAS Al Reem Island, Abu Dhabi, UAE
800

METERING CABINET Drawing Title


S10 S10 S10 S10 4BR Twin Villa MINIMAL - CHIC -
RHYTHM - Ground Floor Plan
Underground Electrical System
Drawn by: SEL
W.M
Checked by: J.S
Approved by A.A
1x110mm DIA uPVC DUCT FOR ELECRICAL
INCOMING CABLES BURIED IN Drawing Number: RHP1P2-BW-TGC-4TV-FN-SD-EL-00001 Rev:
GROUND FROM INFRA FEEDER PILLER (TO
TEL MANHOLE BOX BE COORDINATED IN INFRA DRAWINGS) IL: 0.80 01
Project Work Bldg ID /Type/ Document
600mm x 600mm x 800mm Name Pakage
Originator
Component ID
Level
Type
Discipline Number
2x110mm DIA UPVC DUCT FROM SERVICE PROVIDER (TIE IN
POINT OUTSIDE THE PLOT LIMIT TO BE COORDINATED AND RHP1P2 BW TGC 4TV FN SD EL 00001
ALIGNED WITH DU INFRASTRUCTURE APPROVED DRAWINGS BY Date: 14.06.2024 Sheet Number:
PROJECT CONTRACTOR) IL: 0.80 Scale: 1:100 1 OF 1