NeuViz Dual
User Manual
Content (Vol 1)
Chapter 4 Scan……..…………………………………………………………….4-0
Chapter 6 Maintenance….……………………………………………………...6-0
454110019578 Content
Rev.2.7
NeuViz Dual
User Manual
This manual is intended to assist users and operators in the safe and effective
operation of the device described. Before attempting to operate the device, you
must read this manual thoroughly, paying particular attention to all Dangers,
Warnings and Cautions incorporated in it. You must pay special attention to all
the information given and procedures described in the Safety section.
In this instruction manual, three safety prompts are included, which are Notes,
Warning and Caution. Before this manual is read, the above safety prompts
must be clearly acquainted with. The following is the definition of safety
prompts:
y Maintenance
y Quality Assurance
Volume 2- Instruction for Use
Containing the following sections:
y Operation Interface
y 2D Viewer
y MPR Viewer
y 3D Viewer
y Brain Perfusion
y Dental
y Film
y Report
1.3 Compliance
Degree of protection
Type B Applied Part
against electric shock
Degree of protection
against harmful ingress of Ordinary Device
water
X-Ray Safety
Failure to control, regulate or operate the device in compliance with
instructions and procedures described in this manual may cause danger and
radiation leak.
The useful X-rays may result in danger if used by unskilled operator although
this device is designed and manufactured in accordance with electric and
mechanical safety regulations and standards. Excessive X-rays can result in
serious body injuries.
Avoid “unqualified” and “unauthorized” personnel to operate the device so as to
protect the patient, operator or any other persons from unexpected X-ray
radiation.
If it is necessary for the operator to enter the room when the system is
discharging, he/she must wear protective clothing (lead apron).
When gantry tilts or the cradle moves, make sure that the patient does not
tough CT gantry.
Pay special attention to big patient to protect their skin or limbs from being
cramped by cradle and gantry.
The maximum load capability of the cradle is 200kg. Scanning accuracy can be
guaranteed within 200kg. If the weight exceeds this limit, the result might be:
y Property reduction of positioning of system.
y Reduction of scanning speed
y Damage and/or harm to patient
Check the connection of cradle end periodically. If it is damaged or loosed,
please repair and replace it.
1.6.3 Patient Scanning Safety
When performing a scan on a patient, please adhere to the following safety
instructions and rules:
y Close all doors of the Scan Room before a scan process is initiated.
Unless given permission by the doctor in charge, allow no one to enter
the Scan Room during the scan process.
y Advise the patient not to move during the positioning or scanning
procedures.
y Ensure that the patient's fingers and clothing do not get caught in
device during patient positioning.
y Advise the patients not to raise their heads or move their bodies during
scans.
y Remind the patients not to touch any external apparatus, such as
infusions and resuscitation device.
y Unchecked accessories can cause artifacts, injuries to the patient and
operating personnel or damage to the device. Therefore, only use
accessories approved by NMS and replace defective accessories by
new original accessories immediately.
y Ensure that all patient-support accessories (head holders, table
mattress, patient table extension, side rails, arm supports, leg support,
knee support, pediatric cradle) are whole and not damaged.
y Check that the head holders and leg supports are securely locked to
the patient table.
If damages or defects should occur on the system (patient table, Gantry) on
454110019578 1-11 Safety Instruction
Rev. 2.7
NeuViz Dual
User Manual
Do not subject the system to serious mechanical shock, as the cathode ray
tube (CRT) can fracture if struck or jarred. This may result in flying pieces of
This device must not be used in the presence of explosive gases or vapors,
such as certain anaesthetic gases. Use of electrical device in an environment
for which it was not designed can lead to fire or explosion.
Use of electrical device in an environment for which it was not designed can
lead to fire or explosion. Conductive fluids that seep into the active circuit
components of the operator’s console may cause short circuits that can result
in electrical fires. Therefore, do not place any liquid or food on any part of the
consoles or other modules of the system.
Fire regulations for the type of medical area being used should be fully applied,
observed and enforced. Fire extinguishers should be provided for both
electrical and non-electrical fires.
All operators of this CT system should be fully aware of and trained in the use
of fire extinguishers and other fire-fighting device, and in local fire procedures.
1.6.9 Oil Leaks
The x-ray tube and H.V. generator are oil-cooled. This is a closed-circuit
system that is sealed.
stop button on the top of gantry panel or on the scan control panel.
Please pay attention to Warning labels of each part. Refer to Service Manual
for other safety warning labels
In the process of operation and maintenance, system software will display
Warning or Error information in accordance with conditions. Please follow the
directions to operate. Refer to Service Manual for detailed information.
1.9 Training
454110019578
2-1
REV.2.7 System Description
NeuViz Dual
User Manual
This system uses the attenuated X-Ray signal to reconstruct the body images
for the purpose of clinical diagnosis after X-Ray penetrates the scanned body.
Double detectors equipped in the system can acquire two images
simultaneously during each exposure.
454110019578
2-2
REV.2.7 System Description
NeuViz Dual
User Manual
454110019578
2-4
REV.2.7 System Description
NeuViz Dual
User Manual
The patient table will move back when the operator
initiating the scanner.
454110019578
2-5
REV.2.7 System Description
NeuViz Dual
User Manual
454110019578
2-7
REV.2.7 System Description
NeuViz Dual
User Manual
2.2 Gantry
On the right and left side of gantry, there is a control panel respectively. The
buttons on the control panels perform the table in, table out, ascending and
lowering operations of the couch and tilting operation of the gantry manually to
position patients for scanning. As is shown in Figure 2-6.
454110019578
2-8
REV.2.7 System Description
NeuViz Dual
User Manual
z Positive Tilt
Press this button to tilt the gantry away from the operator.
z Negative Tilt
Press this button to tilt the gantry towards the operator.
z Head Position
Press this button to elevate couch to a pre-defined height, and then
move the table into the gantry bore. If the table height isn’t less than
the pre-defined height, the table moves into the gantry bore directly.
z Body Position
z Cradle Out
Press to move the table out of the gantry bore horizontally.
454110019578
2-9
REV.2.7 System Description
NeuViz Dual
User Manual
z Quick Cradle In
z Movement Reset
Click this button, if the gantry tilts, it will go back to 0 degree position,
and the cradle out operation is performed before the couch descent
operation from the original position if the couch is not cradled out. If
it’s on the original position, then the couch descent operation is
performed directly.
Press and hold for a while, display the maximal range of couch in,
couch up, positive gantry tilt, and turn on laser localizer. Press and
hold again, display the maximal range of couch out, couch down,
negative gantry tilt, and turn off laser localizer. The laser beam
automatically turns off after 1 minute.
454110019578
2-10
REV.2.7 System Description
NeuViz Dual
User Manual
Table 2-2 Display panel function List
454110019578
2-11
REV.2.7 System Description
NeuViz Dual
User Manual
It is the power switch to CT scanner. When the voltage of power supply is lower
than required or the emergency stop button is pressed, it turns to OFF position
and the scanner is shutdown. User has to switch it on manually when power
supply meets the requirement or the emergency stop button is reset.
For more details of system shutdown and startup, refer to sections Shutdown
and Start-up.
− GANTRY LIMIT
It is a system advance indicator light and it is not available now.
− TABLE LIMIT
It turns to red when the table height or table position is out of its
limitation. Otherwise, it is off.
− TILT LIMIT
It turns to red when the gantry tilts to a degree out of the limitation.
Otherwise, it is off.
− VERT. TABLE
Display the current table height relative to the floor. (Unit: mm)
− HOR. TABLE
454110019578
2-12
REV.2.7 System Description
NeuViz Dual
User Manual
Display the current table position relative to the end of couch or the
− GANTRY TILT
Display the current tilt angle of the gantry. Negative tilt means the
top of the gantry tilts to the end of couch. Positive tilt means the top
of the gantry tilts to the front of couch. The angle is from -30.0° to
+30.0°. (Unit: degree)
− MANUAL SCAN
It is a system advance indicator light and it is not available now.
− X-RAY ON
It turns to yellow during X-Ray exposure. Otherwise, it is off.
Laser Localizer is on when press the buttons on the gantry except the ,
, buttons.
454110019578
2-14
REV.2.7 System Description
NeuViz Dual
User Manual
2.3 CT BOX
CT-BOX has a display panel, which displays the status of gantry and table, and
a scan control panel.
Table 2-3 CT BOX Buttons List
No Name Description
454110019578
2-15
REV.2.7 System Description
NeuViz Dual
User Manual
operator.
454110019578
2-16
REV.2.7 System Description
NeuViz Dual
User Manual
2.4 Accessories
454110019578
2-18
REV.2.7 System Description
NeuViz Dual
User Manual
Caution: Keep the scan room clean and tidy because dust and
corrosive air may shorten the service life of the whole
system.
2.5.1.2 Power Supply
The requirements of power supply for the system to function properly are
detailed below:
Table 2-5 Power Supply List
2.5.2 Start-Up
After the procedures above, the operating console monitor displays the main
interface of operating software automatically.
454110019578
2-20
REV.2.7 System Description
NeuViz Dual
User Manual
2.6 Shutdown
454110019578
2-21
REV.2.7 System Description
NeuViz Dual
User Manual
WARNNING: The user should strictly comply with the start-up and
shutdown system procedures.
454110019578
2-22
REV.2.7 System Description
NeuViz Dual
User Manual
454110019578
2-23
REV.2.7 System Description
NeuViz Dual
User Manual
The main function buttons of the Daily Operation Module in system main
interface are shown below:
The daily operations include the following items: Tube Warm-Up, Air
Calibration, Schedule, Scan, and Protocol.
When the system has been powered down for a long time (for example, when
start up the equipment every day), the tube heat will drop down. If the tube heat
is below 15%, warm up the tube first. If the tube heat is below 15% at start-up
process, the tube warm-up prompts will appear. Follow the prompts and
perform the following operation to warm up the tube:
If parameter items are marked with blue, all of corresponding parameters in the
list are selected with check mark, as figure is shown below:
If【Scan Name】is marked with blue, users can select calibration conditions
according to the scan name in the list.
3.4 Protocol
Tags on the top of the interface, which include 【Protocol edit】, 【Display edit】,
【Recon.Kernel】, 【Film Template】can be selected.
3.4.1 Protocol edit Interface
System consider 【Protocol edit】tag interface as default interface. Users can
select adult or Children protocols by clicking the 【Adult Protocols】 or
【Children Protocols】 tab on the left of the protocols display panel, see figure
below, pink means infant protocol, azure means children protocol with age
more than 12 months.
Users can add, delete, save parameters of scan series for selected
【Set as the default protocol for this anatomy】: Set this protocol as the
default protocol for selected anatomy.
【Auto Film】: The check box determines whether film the image after
scan, and select the desired film template from the
list.(refer to Film Template description in this chapter)
【limit’s kind】&【limit to】: Two kinds of limit can be selected, age and
weight. Users can type in the range in
blank sheet.
【Species】: Classify the protocol, and decide what kind of patient can
use this protocol, Adult, Child or Infant
【Scan Type】: Classify the protocol, and decide what type of the
protocol is. Four types can be selected, Surview, axial,
helical and compound. (refer to Patient Register
interface )
z Add/Save/Delete/Back operation on 【Edit Protocol interface】: Users
can press【Update】button on 【Edit Protocol interface】 to save the
protocol which was changed.
To delete the selected series of selected protocols, click 【Delete】
button.
To return to the Protocol Edit Interface, click 【Back】button.
2. 【Modify】: Select a protocol in the data list and click 【Modify】 button, the
edit dialog box will pop up (same as Display Edit Dialog Box, but users
cannot change the Name item). Modify the protocol selected in the edit
dialog box.
Function.
Chapter 4 Scan
4.1 Schedule ............................................................................................... 4-1
4.1.1 Patient Positioning...................................................................... 4-1
4.1.2 Patient Schedule ......................................................................... 4-1
4.1.2.1 Patient Register Interface.................................................. 4-1
4.1.2.2 Register Interface .............................................................. 4-3
4.1.2.3 All Scanned ....................................................................... 4-8
4.2 Main Scan Interface.............................................................................. 4-9
4.2.1 Scan Control Panel ..................................................................... 4-9
4.2.2 Display Current Information..................................................... 4-11
4.2.3 Setting Scan Parameters .......................................................... 4-11
4.2.3.1 Pilot Scan .........................................................................4-11
4.2.3.2 Add Scan Series.............................................................. 4-16
4.2.3.3 Axial/Helical Scan Parameter .......................................... 4-16
4.2.3.4 Axial Scan ....................................................................... 4-18
4.2.3.5 Spiral Scan ...................................................................... 4-18
4.2.3.6 Reinforced and Scan Triggering ...................................... 4-18
4.2.3.7 Parameter of Voice.......................................................... 4-23
4.2.3.8 Parameter of Image Construction.................................... 4-24
454110019578
Rev.2.7 4-0 Scan
NeuViz Dual
User Manual
4.1 Schedule
Click the icon on the top left of the interface, then enter the Register
454110019578
Rev.2.7 4-1 Scan
NeuViz Dual
User Manual
interface, as is shown in follows:
Click the icon on the top left of the interface, then enter the All
Scanned interface, as is shown in follows:
454110019578
Rev.2.7 4-2 Scan
NeuViz Dual
User Manual
454110019578
Rev.2.7 4-3 Scan
NeuViz Dual
User Manual
【Patient ID】
Compulsory information. Numbers or letters can be inputted. The identification
is the unique serial number for each patient, and the operator is to set patient
ID according to the rules of the hospital. The maximum length of patient
identification is 30 characters.
【First Name】and【Last Name】
Compulsory information. Attention: do not input “.”; and the maximum length of
patient name is 255 characters.
【Gender】
Compulsory information. Click the circle radio button before the option, a black
dot will appear indicating that the item is selected.
【Age】
Compulsory information. The age number will change automatically according
to the Birthday field filled. Fill the patient age in the age text box and click the
list arrow next to the age text box to select the desired unit from the list
displayed.
454110019578
Rev.2.7 4-4 Scan
NeuViz Dual
User Manual
【Birthday】
Compulsory information. The year of birth will change automatically according
to the age filled if the age field is active otherwise modify the month value and
day value by either directly modifying the number before the day and month
item or by clicking the list arrow to open a drop down menu of selections, and
select the patient birthday from the perpetual calendar on it.
【Age Group】
Compulsory information. There are three groups for selecting: Infant, Child and
Adult. Click the circle according to the age of the patient.
【Height】
Non-compulsory information. Input the patient’s height (unit: cm).
【Weight】
Non-compulsory information. Input the patient’s weight (unit: kg).
【Accession Number】
Non-compulsory information, for the management of patient ID in the hospital.
【Voice Language】
Compulsroy information. Select the voice prompted acceptable to the patient.
【Referring Physician】
For display only. No alteration is allowed. You can add a user in configuration.
Refer to Chapter 5 in User Manual for detailed information.
【Requesting Physician】
Non-compulsory information, Input the information about Referrer.
【Operator Name】
Non-compulsory information, Input the Performer information.
【Description】
Non-compulsory information. Patient related information can be inputted per
diagnostic requirements with the valid content within 100 characters.
Notes: ‘*’ mark before the compulsory blank will disappear after
filling in.
【Schedule again】
Select a registered patient, then click 【Schedule again】under 【Catalog】to
modify the existing information about the patient.
454110019578
Rev.2.7 4-5 Scan
NeuViz Dual
User Manual
【Delete Patient】
Select a registered patient, then click 【Delete Patient】under 【Catalog】. The
following dialog box appears:
Click 【Confirm】to finish the deletion. Click 【Exit】to cancel the deletion.
【Search】
Click 【Search】under 【Catalog】. Then the following dialog box appears:
454110019578
Rev.2.7 4-7 Scan
NeuViz Dual
User Manual
On the left of the above scanning interface, there is a body graphics. Users
could select the region to be checked at random, including Head, Eye, Neck,
Vertebra, Abdomen, Extremity, Ear, Sinus, Lung, Lumber, Pelvis and Others.
Click the anatomy symbol beside the body graphics to select the region to be
scanned, and at the same time appears the scan mode to be used to scan the
selected region.
Click 【Next】to begin scanning.
4.1.2.3 All Scanned
For more details, refer to 1.2.2 Registered Interface.
454110019578
Rev.2.7 4-8 Scan
NeuViz Dual
User Manual
【Scan】: Start scan. If users want to cancel or stop scan, they can use stop
button on CT BOX.
【Cancel Scan】:
454110019578
Rev.2.7 4-9 Scan
NeuViz Dual
User Manual
【End Study】: Finish current patient scan
【Exit】: Exit scan interface but do not finish current patient scan
Click 【Scan】 to start the scan. Make sure that nobody irrelevant with the
patient is in the room and the protective door is closed before scanning. The
radiation information in the interface shall be observed carefully when scan is
being performed. If a contra-indications exist, press 【Stop】button on CT-Box
to stop the scan, or click the emergency stop switch on the physician’s console
to terminate X-ray production.
Caution: Do not enter the Scan Room until the x-ray production is
completely ended to prevent harm from radiation.
454110019578
Rev.2.7 4-10 Scan
NeuViz Dual
User Manual
4.2.2 Display Current Information
454110019578
Rev.2.7 4-11 Scan
NeuViz Dual
User Manual
select the region to be scanned in order to control the subsequent scans.
The first series of each patient can be film series. When the first series in the
list is selected, the film option card can be used if the series has not been
scanned, and the series can be set as film series. You can set the following
parameters for the film series.
【PA】: To select the tube position during scan. The positive scan is that the
pilot scan is performed by the tube right above the gantry.
【Lateral】: To select the tube position during scan. the lateral scan is that the
pilot scan is performed by the tube from the right side of the gantry.
【Couch In】: To select the direction of couch motion with the direction of
“Couch In”.
【Couch Out】: To select the direction of couch motion with the direction of
“Couch Out”.
【Auto Voice】: Whether to perform the auto breath navigation.
【Start (mm)】: To set the couch position at the beginning of the scan process.
If the initial position is empty, the present couch position is set as the initial
position. Unit: mm.
【Length (mm)】: Effective displacement of the couch movement, used for
imaging during the pilot scanning process. It is used to set the film length. Unit:
mm.
【Current (mA)】: Current parameter for scan. Unit: mA.
【Voltage (kV)】: Voltage parameter for scan. Unit: kV.
【FOV】: Image construction parameter, In pilot scan, if the scan length is not
above 500 mm, the view is 500; if the scan length is above 500mm, the Rec
FOV is equal to scan length.
【Window Width】: The window width of the film image.
【Window Location】: The window level of the film image.
Perform the image construction while the pilot scan is being performed, and
the film is displayed directly after scan is completed.
454110019578
Rev.2.7 4-12 Scan
NeuViz Dual
User Manual
454110019578
Rev.2.7 4-13 Scan
NeuViz Dual
User Manual
clicking the mouse on the image, or select the items in the【Mode Name】list.
4.2.3.1.4 Adjust Positioning Series
Adjust Start Position
The 【Start Position】parameters can be inputted in the scan parameters or in
the quick parameter panel. Alternatively, select corresponding series in the film
image and press the left mouse button in the series, then move the cursor in
the direction of couch to adjust the initial position. If the series exceeds the
display range of the film, the initial position can be adjusted only by inputting
the parameters in【Start Position】.
Adjust Scan Length
The parameters of【Scan Length】can be inputted in the scan parameters or in
the quick parameter panel. Alternatively, select the series in the film image
through pressing the left mouse button on initial border or ending border of the
series frame, then moving the cursor in the direction of the couch to adjust the
scan length. If the series exceeds the display range of the film, the view can be
adjusted only by inputting parameters in【Scan Length】. In addition, if the
method of dragging borders of the frame is used, the【Start Position】 will be
modified at the same time.
Adjust View
The 【Image Construction View】 parameters can be inputted in the Image
Construction parameters panel. Alternatively, select the corresponding series
directly in the film image and press the left mouse button on either side of the
frame, then move the cursor in the direction of perpendicular to couch to adjust
the view. If the series exceeds the display range of the film, the view can only
be adjusted by inputting the parameters in【Start Position】.
Adjust Central Coordinate of Image Construction
For the positive film, the parameters of【Center X】can be inputted in Image
Construction parameters panel . Alternatively, select the series in the film
image and press the left mouse button while pressing the Shift key at the same
time in the series, then move the cursor in the direction of perpendicular to
couch to adjust the coordinate. If the series exceeds the display range of the
film, it is can only be adjusted by inputting the parameters in【Center X】. In
addition, press the Ctrl key on the image to adjust, both the【Start Position】and
【Center Y】will be modified at the same time.
For the lateral film, the above adjusted parameter shall be【Center Y】.
Adjust Gantry Tilt Angle
For the lateral film, if the machine tilt angle is allowed ,the parameters of【Tilt】
454110019578
Rev.2.7 4-14 Scan
NeuViz Dual
User Manual
can be inputted in the scan parameters or in the quick parameter panel.
Alternatively, select the corresponding series in the film image and press the
left mouse button on each of the four corners, then move the cursor in the
direction of couch to adjust the tilt angle. If the series exceeds the display
range of the film, the tilt angle can only be adjusted by inputting the parameters
in【Tilt】.
Flip Scan Direction
The operator may select the scan series to be adjusted, press the right mouse
button and select【Flip Series】from the pop-up menu to flip and change the
scan direction.
4.2.3.1.5 Delete Positioning Series
To delete selected positioning series press Delete; or click the right mouse
button and select【Delete Present Series】from the popup menu .The functions
are the same as that of 【Delete】function in the panel below. (Only when the
series selected from the【Selected Protocol】list is not scanned.)
4.2.3.1.6 Right Button Menu
You can perform various frequently used operations through the right-button
menu at any time. The right-button menu in film includes three kinds of
operations: series operation, image adjustment and display control.
454110019578
Rev.2.7 4-15 Scan
NeuViz Dual
User Manual
4.2.3.2 Add Scan Series
If users want to add other scan protocol series, press 【Add Scan】button to
enter protocol select interface, figure is shown as below:
Four tags on the left of the protocol display frame can be seen on the above
figure, including Pilot, Axial, Helical and Exam. For protocols in Exam, each
protocol has no less than two scan series.
Select a protocol, then press【Next】to return scan interface.
4.2.3.3 Axial/Helical Scan Parameter
All the optional parameters of axial scan, helical scan are listed here.
454110019578
Rev.2.7 4-16 Scan
NeuViz Dual
User Manual
【Scan Mode】: To specify the scan type: Axial Scan, Helical Scan.
【Voltage】: The scan voltage parameter. Unit: kV
【Current】: The scan current parameter. Unit: mA
【Collimation】: Slice thickness. Unit: mm.
【Rot. Time】: The Rotation speed, used to define the time of one rotation of
the tube. Unit: s.
【Sample】: The sampling numbers of each scan layer.
【Pitch】:Helical scan parameter. The pitch of spiral scans. Unit: mm.
【Increment】: Slice Increments. Unit: mm.
【Rot. Number】:Number of Scan layers.
【Start】: The start position of a series when the scan starts. Unit: mm.
【Scan Time】: Helical scan parameter. The time consumed in spiral scan.
【Tilt】: The tilt angle of the gantry. Unit: degree.
【Length】: The series length of a scan. Unit: mm.
【Scan Angle】: Effective angle of each scan layer, used to specify partial scan,
common scan and over scan.
【Couch】: Scan Directions, couch in/couch out.
【Auto Voice】: Whether to perform the auto breath navigation and select the
specific voice information for breath navigation system or not.
【Reconstruction】: Whether to reconstruct the images immediately after scan
process or not.
【Trigger】: It sets the option whether to adopt monitoring scan sequence and
sets the scan type. Axial scan trigger contains clinical scan, contrast and
manual. Helical scan trigger contains clinical scan and contrast. Select contrast,
the contrast parameter interface will be active.
454110019578
Rev.2.7 4-17 Scan
NeuViz Dual
User Manual
4.2.3.4 Axial Scan
Axial scans are the normal CT mode of slice-by-slice scanning while the
Patient Table is motionless during the exposure, and the tube rotates around
the patient while radiating rays. If multi layers scan is needed, the back couch
will move to the position of next layer automatically according to the operator’s
setting, after one layer is completed till all the axial scan operation is
completed.
The axial scan operation can be performed after the pilot scan is completed,
and start after positioning is carried out on the film image, or it can be
performed directly after the scan part is determined by laser localizer without
the pilot scan process.
4.2.3.5 Spiral Scan
During spiral scan process, the X-ray tube rotates continuously to produce
X-ray beam and the patient table is incrementing continuously in the axial
direction. So the X-ray track in the scanning area is a spiral movement for the
patient under inspection.
The spiral scan operation can be performed after the pilot scan is completed,
and start after positioning is carried out on the film image, or it can be
performed directly after the scan part is determined by laser localizer without
the pilot scan process.
4.2.3.6 Reinforced and Scan Triggering
If user set the【Trigger】 parameter of a scan series (non-pilot series) as
Manual to perform the manual scan. Namely, the operators can control the
start time of rays discharging time. After the scan preparation is completed, the
information prompt box for discharging rays by manual is displayed before the
X-ray exposure. There is a certain limit for manual operation: a time display is
shown on the top from zero time with the unit as second after the prompt box
pops up. After the time exceeds 180 seconds, the scan is aborted
automatically if it is not started. Click【Start Scan】in 180 seconds, the rays
discharging operation is started if the Auto Voice item is not selected. If the
Auto Voice item is selected, the scan operation is started after the
corresponding voice tips are sent out.
Select the Contrast Scan from the Trigger list, the Contrast label is active, refer
to the following figures:
454110019578
Rev.2.7 4-18 Scan
NeuViz Dual
User Manual
(3) Bolus timing appears and the localization layer and the tracking layer
will be automatically added.
(4) The localization layer will be first scanned. After that, the shape of the
454110019578
Rev.2.7 4-20 Scan
NeuViz Dual
User Manual
(5) Inject the contrast. Take care of the injection dosage and speed, and
properly set the associated parameters to guarantee an ideal scan
result.
454110019578
Rev.2.7 4-21 Scan
NeuViz Dual
User Manual
(7) Select【scan】the blue bar shows the scan speed and the gray bar
stands for the scan duration. After the blue bar is full of the gray bar,
the helical scan starts.
454110019578
Rev.2.7 4-22 Scan
NeuViz Dual
User Manual
454110019578
Rev.2.7 4-24 Scan
NeuViz Dual
User Manual
454110019578
Rev.2.7 5-0 Archives Management
NeuViz Dual
User Manual
There are three available functions in the Archives Manager Module: Data
Management, Image Process and DICOM Output & Print.
The Archive Manager is used to browse the patient scan data and images in
the database; export or import data; query and edit the patient information,
scan data and image data; image reconstruction, image mergence, and 2D
display.
All the data of a patient includes patient information, scan data and the
generated image data.
z Click【Scan Series】, all the scan series of the selected patient will be
displayed in the dialog box with the following scan information: Serial
454110019578
Rev.2.7 5-2 Archives Management
NeuViz Dual
User Manual
number, scan type, scan mode, voltage, current, rotate speed, initial
position, slice thickness, gantry tilting angle, pitch/couch length, scan
cylinder number, enhancement mark, data state, DAS information, couch
movement direction, sampling number, large and small focus etc.
z Click one of the scan series data record, and the corresponding row will
turn blue indicating that the scan series is selected. Meanwhile,
corresponding scan series information is displayed on the 【Data List】
display region below.
z Click【Image Series】, and the selected image series will be displayed in the
dialog box with the following information: Image thickness, scan mode,
enhancement mark, view, image numbers, window width, window position,
data status, image scheme, filtering parameter, etc., refer to figure 5-4.
z Click one of the image data record, the corresponding row will turn blue
indicating that the image series is selected. Meanwhile, the image series
information is displayed on【Data List】region below.
454110019578
Rev.2.7 5-3 Archives Management
NeuViz Dual
User Manual
454110019578
Rev.2.7 5-4 Archives Management
NeuViz Dual
User Manual
of the selected series will be displayed in the 【Data List】display area,
including image number, general image number, couch position code, study
time, etc.
z Click one of the image records, and the selected row will turn blue.
Meanwhile, the image specified by the record will be displayed on display
area on the right side.
Figure 5-6 Generated Information from Image Data and the Corresponding Image
454110019578
Rev.2.7 5-5 Archives Management
NeuViz Dual
User Manual
z Click in Data Source, then appears Figure 5-8. Users could select
different backup disks as data source. All the patient information in the hard
disk will be displayed on the patient list area on the left side of the interface.
454110019578
Rev.2.7 5-6 Archives Management
NeuViz Dual
User Manual
Notes: Data in default backup disk is only used for browse and
does not support operations as follows: Patient Login,
Change, Scan Pre-selection, Image Construction, Image
Composition and the change of Window Width or Window
Level.
Notes: Click various options on the patient list in figure 5-2 or
figure 5-9 to arrange patient data in order or reverted order
by the selected option.
5.2.2 Refresh
Click , and all the patient information of the selected data source will
be displayed on the patient list area.
454110019578
Rev.2.7 5-7 Archives Management
NeuViz Dual
User Manual
5.2.3 Search
Various search methods are provided for the operators to search the needed
data conveniently. Operators can search information with single condition or
multi combined conditions. Fuzzy searching function is supported in the
system.
Select the data source to be searched, click , and the patient search
dialog box will appear as below:
z Search by Patient ID
Select 【Patient ID】 in 【Patient Search】 interface, input the patient ID
454110019578
Rev.2.7 5-8 Archives Management
NeuViz Dual
User Manual
to be searched and click 【OK】, the filtering result will be displayed in the
list box.
z Search by Name
Select 【Name】in【Patient Search】 interface, input the name to be
searched and click 【OK】, the filtering result will be displayed in the list
box.
z Search by Sex
Select 【Sex】 in 【Patient Search】 interface, click the sex option to select
the desired sex, and click 【OK】, the filtering results will be displayed in
the list box.
z Search by Age
Select 【Age】 in 【Patient Query】 interface, input the age to be Searched
and click 【OK】, the filtering results will be displayed in the list box.
z Search by Study Date/Time
Select【Study Date/Time】in 【Patient Search】 interface, input the time
or select the study time to be searched, and click 【OK】, the filtering
results will be displayed in the list box.
z Search by Technician
Select 【Technician】in 【Patient Search】 interface, input the name of
the technician to be searched and click 【OK】, the filtering results will be
displayed in the list box.
z Search by Lock Option
Select 【Lock】 in 【Patient Search】interface, then select【Yes】or【No】,
and click【Ok】, the results will be displayed in the list box.
z Search by Pre-registered Patient
Select 【Pre-registered Patient】 in 【Patient Search】 interface, then
select【Yes】or【No】, and click【Ok】, the results will be displayed in the
list box.
z Search by Diagnostic Report Printing
Select 【Printed】in【Patient Search】interface, then select【Yes】or【No】,
and click【Ok】, the result will be displayed in the list box.
z Search by Protocol Name
Select 【Protocol Name】 in 【Patient Search】 interface, and select the
mode name from the pull down box on the right side, click 【Ok】, and the
454110019578
Rev.2.7 5-9 Archives Management
NeuViz Dual
User Manual
searched result will be displayed in the list box.
z Search by Description
Select 【 Description 】 in 【 Patient Search 】 interface, input the
technician diagnostic description in the edit box on the right side, and
click 【Ok】, the searched result will be displayed in the list box.
5.2.4 Delete
The delete operation supports patient delete, scan/image series delete and
scan/image data delete.
5.2.4.1 Delete Patient
Select the patient to be deleted from the patient list, click , and a
prompt dialog box will appear for delete operation confirmation.
Click 【Confirm】to delete the patient information. Click 【Exit】to cancel the
operation.
Caution: The delete operation can delete the scan/image data and
video data permanently. Be cautious to avoid losing data.
Notes: Press the left mouse button and Ctrl key simultaneously,
several patient records can be selected with blue color
highlight. Press the left mouse button and Shift key
simultaneously; several consecutive patient names or IDs
in list box can be selected.
The locked patient cannot be deleted until it is unlocked.
454110019578
Rev.2.7 5-10 Archives Management
NeuViz Dual
User Manual
5.2.4.2 Delete Scan/Image Series
Select the patient whose data is to be treated from the patient list, select the
scan/image series to be deleted from corresponding【Scan Series List】 and
【Image Series List】, then click , a prompt dialog box will appear for
delete operation confirmation.
corresponding data list, click , and a prompt dialog box will appear
for delete operation confirmation.
Click【Confirm】 to delete the selected data. Click 【Exit】to cancel the delete
operate.
454110019578
Rev.2.7 5-11 Archives Management
NeuViz Dual
User Manual
5.2.5 Fix Patient Data
Select the patient to be modified from the patient list, click , modify
dialog box will appear as below:
Except for the operator, all information can be modified, including: Patient ID,
Name, Sex, Age, Birthday, Height, Weight and Information Description. The
operator is to ensure the validity and authenticity of the inputted patient
information.
Click 【Confirm】to complete the modification. Click【Exit】to cancel the
operation.
5.2.6 Film Image
Select a series to be printed in the Image series List, or select an image to be
printed in the Data List. Then click , after that appears the dialog box
below:
454110019578
Rev.2.7 5-12 Archives Management
NeuViz Dual
User Manual
Click【Confirm】to enter the Film Interface. For more details about Film, refer to
Volume 2.
5.2.6.1 Copy to
Select records from the list, click , the following interface will appear
to select store disks to store selected records:
454110019578
Rev.2.7 5-13 Archives Management
NeuViz Dual
User Manual
(1)If the backup disk is not found, the following dialog box will appear:
To make sure whether the backup disk is inserted in a proper way, refer to
【Usage of CD-R/CD-RW】for detailed information.
(2)The status of backup disk is normal
If the status of backup disk is normal, the following dialog box will appear.
Select data type for export, the remaining disk space and the required space
for back up will be displayed simultaneously.
454110019578
Rev.2.7 5-14 Archives Management
NeuViz Dual
User Manual
For the data type to export, you can select raw data, image, or both. Click【OK】,
and the export operation is executed with the progress indicated by a progress
bar on the screen.
After the operation is completed, the following dialog box will appear to inquire
if the records in local database shall be reserved. Select【Yes】, and the data
are reserved; select【No】, and the data will no longer be reserved.
454110019578
Rev.2.7 5-15 Archives Management
NeuViz Dual
User Manual
Click , then the database of backup disk will be updated while the
data will be imported to the local disk at the same time. Select Upgrade option,
then the database of backup disk is upgraded while the data will not be
imported to the local disk.
If the backup database version is the same as the required one, the following
dialog box will appear. Select the data type for import, and the remaining disk
space and the required space will be displayed at the same time.
The data type of import can be raw data, image, or both. Click【OK】, and the
operation will be executed with the recovery progress indicated by a progress
bar on the screen.
After the import operation is completed, a dialog box will appear to inquire if the
records of database in the back up disk shall be reserved. Click 【Yes】, the
454110019578
Rev.2.7 5-16 Archives Management
NeuViz Dual
User Manual
data will be kept down; select【No】, the data will no longer be kept down.
Figure 5-23 Dialog Box for the Confirmation of Keeping Down Data
More than one patient data import or export can be performed simultaneously
through using the mouse and Shift or Ctrl combination key.
The import or export operation cannot be performed to the data or image
construction of a patient being scanned
5.2.6.3 Usage of CD-R /CD-RW
The CD Writing program of WINDOWS XP is loaded in the console system and
the following dialog box will appear when WINDOW XP is writing a CD:
Input CD name, and then click “Next”, a progress bar will appear on the screen
to indicate the progress.
454110019578
Rev.2.7 5-17 Archives Management
NeuViz Dual
User Manual
If there is not enough space on CD-RW, you can erase the CD-RW on
WINDOWS XP operating system to release the space.
5.2.7 Lock
The system provides Lock function to enable the user to protect the date of
special patients from being modified or deleted accidentally.
Select the patient to be locked from the patient list and click to lock
the patient. The patient list lock item will become True at the same time.
5.2.8 Unlock
Select the patient to be unlocked from the patient list and click to
unlock the patient. The patient list lock item will become False at the same
time.
More than one patient lock or unlock operations can be performed by using the
mouse and Shift or Ctrl combination key.
454110019578
Rev.2.7 5-18 Archives Management
NeuViz Dual
User Manual
5.2.9 Load to Viewer
Select a patient from patient list, then click , and the system will load
images to enter image display and process interface, refer to Vol. 2 for 2D
display.
5.2.10 Image Mergence
Through the images mergence process, the image artifact effect can be
lessened without losing resolution power. For example, if the basilar images
composed by 3 layers of 3mm slices are composed, under the same resolution
power, the capacity artifact is decreased significantly compared with scanned
image with 10mm technology, as is shown in the following figure. In the
combine images operation, there are at least two images and the couch code
shall be continuous.
After the image sequences to compose are chosen in【Image Sequence List】,
454110019578
Rev.2.7 5-19 Archives Management
NeuViz Dual
User Manual
454110019578
Rev.2.7 5-20 Archives Management
NeuViz Dual
User Manual
5.3.1 Schedule
Refer to Schedule in chapter 4 Scan for detailed information
5.3.2 Scan
Refer to Scan in chapter 4 for detailed information.
454110019578
Rev.2.7 5-21 Archives Management
NeuViz Dual
User Manual
Figure 5-30 Dialog Box for the Image Reconstruction of Spiral Scan
454110019578
Rev.2.7 5-22 Archives Management
NeuViz Dual
User Manual
Reconstruction, Basilar Special Reconstruction, Head Metal Artifact, Body
Metal Artifact, Head Clear Reconstruction and Body Clear Reconstruction.
z According to the diagnosis requirements, related values can be selected or
inputted from the scan parameters.
z 【Thickness】:Image Reconstruction Thickness, It is used to specify the
number of reconstruction layers for every circle of scan and the thickness
of reconstruction layers. For single row CT scan, the setting is 1×(Slice
Thickness) all the time; for dual CT scan, the default value is 2×(Slice
Thickness), and another option is always 1×(2×Slice Thickness).
z 【FOV】:The image construction view. The default value is the last
inputted value with the range of 5cm-50cm.
z 【Filter】:The selection range is 0~1. Through the alteration of filter
parameters, the sharpness and noise level of reconstructed images can be
adjusted. The noise in the image increase as the sharpness of the image
increases, and vice versa. In general, the low contrast resolution
decreases as the spatial resolution (and the image noise) increase.
z 【Center X】:The unit is mm. The positive direction is from the left side to
the right side of the patient, and the rotation centre is coordinate origin.
Through the alteration on 【Central Coordinate X】【 , Central Coordinate Y】
and【FOV】, only the interested area can be reconstructed.
z 【Center Y】:The unit is mm. The positive direction is from the back (P) of
the patient to the front side (A) of the patient, and the rotation centre is
coordinate origin.
z 【Start Pos.】:Start Position, It is a parameter of the spiral scan. The
position of the first layer is defined as zero position, the parameter means
the initial position towards the zero position related to the image
reconstruction.
z 【Scan Distance】: It is a parameter of the spiral scan which gives the
region covered by the Helix. The parameter is given by the system and is
not editable.
z 【No. Slice】:As a parameter of the spiral scan, it set the number of layers
expected for each reconstruction.
z 【Interval】: It is used to set the distance between two consecutive
reconstructed slices.
z 【Starting Slice】:As a parameter of the axial scan, it shows the starting
slice of the reconstruction process.
z 【Ending Slice】:As a parameter of the axial scan, it shows the ending
454110019578
Rev.2.7 5-23 Archives Management
NeuViz Dual
User Manual
slice of the reconstruction process.
When all the related settings are set, click【Confirm】, and the reconstruction
task is added while the reconstruction information is displayed on the image
construction manager (Refers to Image Construction Manager Window). Click
Terminate button, and the present process can be stopped. Click the Exit
button, and the operation is canceled while the reconstruction window is
closed.
454110019578
Rev.2.7 5-24 Archives Management
NeuViz Dual
User Manual
Chapter 6 Maintenance
6.1 Introduction to Maintenance Interface............................................... 6-0
454110019578
Rev.2.7 6-0 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-0 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-1 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-2 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-3 Maintenance
NeuViz Dual
User Manual
System Log records the system operation and the time when it happens.Click
454110019578
Rev.2.7 6-4 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-5 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-6 Maintenance
NeuViz Dual
User Manual
454110019578
Rev.2.7 6-7 Maintenance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-1 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-2 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-3 Quality Assurance
NeuViz Dual
User Manual
Column
Specification
Number
1 The nylon body includes six small polycarbonate columns whose
diameters are 3mm, 4mm, 5mm, 6mm, 7mm and 8mm respectively.
2 Polyethylene
3 Teflon
4 The organic glass has seven rows of holes with different diameters.
Each row has five holes with same diameter and interval.
Row 1 1.00 mm hole, interval 2.00 mm
Row 2 1.25 mm hole, interval 2.50 mm
Row 3 1.50 mm hole, interval 3.00 mm
Row 4 1.75 mm hole, interval 3.50 mm
Row 5 2.00 mm hole, interval 4.00 mm
Row 6 2.50 mm hole, interval 5.00 mm
Row 7 3.00 mm hole, interval 6.00 mm
5 Lexan
6 Perspex
454110019578
REV.2.7 7-4 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-5 Quality Assurance
NeuViz Dual
User Manual
Figure 7-6 Physics Layer 7mm Slice Width Using Head Std (B) Protocol
454110019578
REV.2.7 7-6 Quality Assurance
NeuViz Dual
User Manual
z Routine check:
Noise——water layer of head phantom
Contrast and Artifact——multi-column layer of head phantom
Noise and Artifact——body phantom
z Monthly check:
Impulse Response——physical layer of head phantom
Slice Thickness — — physical layer of head phantom, which is
corresponded with all the slice thickness.
7.3.1 Routine Check
7.3.1.1 Head Scan
1. Multi-Column Layer Image
The multi-column layer of head phantom is set in the scan center.
To scan and get images with the following scan parameters:
• For NeuViz Dual CT Low Configuration scanner, see the interface
below;
Figure 7-8 Head Scan Parameters of NeuViz Dual CT Low configuration Scanner
454110019578
REV.2.7 7-7 Quality Assurance
NeuViz Dual
User Manual
Figure 7-9 Head Scan Parameters of NeuViz Dual CT High configuration Scanner
Make sure to check the image quality in compliance with the following quality
standard:
z No artifact in any image.
z The followings shall be distinguished:
All the distinguish holes (seven rows) appears in the image of the perspex
columns.
Five of six low contrast columns in nylon body can hardly be observed.
z The following standard (CT Value) of attenuation coefficient on different
columns shall be followed:
• For NeuViz Dual CT High Configuration, see the scan parameters in the
following interface.
454110019578
REV.2.7 7-9 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-10 Quality Assurance
NeuViz Dual
User Manual
7.3.2 Monthly Check
7.3.2.1 Measurement of Impulse Response
Repeat the above steps, and execute 0.8mm (For this machine, it is alternative
layer thickness configuration), 1.0mm, 2.5 mm, 7.0mm and 10mm slice
thickness scan. Therefore, the range of slice thickness measured shall be: 0.8
± 0.5mm, 1.0 ± 0.5mm, 2.5 ± 1.0mm, 7.0 ± 1.0mm and 10 ± 1.0mm
respectively.
454110019578
REV.2.7 7-12 Quality Assurance
NeuViz Dual
User Manual
B1
B5
B4 B3
B2
1. CTDI Phantoms
The CTDI dosimetry phantoms are right circular cylinders of polymethyl
methacrylate (lucite). The density of these phantoms is 1.19 g/cm3. The head
phantom measures 16 cm in diameter and the body phantom has a diameter of
32 cm. The length of each phantom is 15 cm.
The phantom provides means for the placement of dosimeter(s) along its axis
of rotation and along a line parallel to the axis of rotation, 1.0 cm from the outer
surface and within the phantom. The dosimeters are TLD crystals (3.2 mm x
3.2 mm x 0.9 mm) or 10 cm long pencil ionization chamber.
2. CTDI Definition
Computed Tomography Dose Index (CTDI) is the integral of the dose profile
along a line perpendicular to the tomographic plane divided by the product of
the nominal tomography section thickness and the number of tomograms
produced in a single scan, as follows:
1 +50mm
nT ∫-50mm
CTDI100 = D(z)dz
where:
D (z)=Dose to Air (CTDI100) at position z
T = Nominal tomographic section thickness
454110019578
REV.2.7 7-13 Quality Assurance
NeuViz Dual
User Manual
n = Number of tomograms produced in a single scan
The CTDI definition assumes that for a multiple tomogram system the scan
increment between adjacent slices is nT.
Note:
1) The diameter of head phantom is 16 cm.
2) The diameter of body phantom is 32 cm
3) The material of phantom is Perspex.
4) B5:Center
5) The distance between the outside surface of phantom and the
center of B1 to B4 is 1 cm.
6) The location of the position where the CTDI gets to maximum is B5.
7.4.2 CTDI/ Dosage Analysis Information
4.2.1 CTDI/ Dosage Analysis Information of NeuViz Dual Low Configuration
Figure 7-15 Typical Parameter of Testing Dosage (NeuViz Dual Low)
454110019578
REV.2.7 7-14 Quality Assurance
NeuViz Dual
User Manual
+50mm D(z)
CTDI100 = ∫ dz
-50mm NxT
CTDIw=1/3 CTDI100 (center) + 2/3 CTDI100 (peripheral)
Notes: The maximum deviation of the following CTDI value is±
20%.
Table 7-2 Dosage Value (CTDI) of Phantom on Different Positions under Typical
Parameter Condition (NeuViz Dual Low Configuration)
Unit:mGy
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 B1 B2 B3 B4 B5 CTDIw
Head(FOV250) 38.5 34.5 38.2 34.3 33.2 35.3
Body(FOV350) 25.5 18.0 26.6 22.4 10.7 19.0
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 of B5
Normalization Head (FOV250) Body (FOV350)
10mm 1.05 1.05
7mm 1 1
1mm 1.66 1.52
0.8mm 1.31 1.31
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 of B5
Normalization Head (FOV250) Body (FOV350)
454110019578
REV.2.7 7-15 Quality Assurance
NeuViz Dual
User Manual
3s 1.47 1.47
2s 1 1
1s 0.53 0.54
0.8s 0.43 0.44
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 of B5
Normalization Head (FOV250) Body (FOV350)
200mA 1.36 1.37
150mA 1 1
30mA 0.17 0.18
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 of B5
Normalization Head (FOV250) Body (FOV350)
80KV 0.27 0.23
120KV 1 1
140KV 1.27 1.32
Notes: Only one parameter can be modified each time, the
configuration of other parameters is typical value.
4.2.2 CTDI/Dosage Analysis Information of NeuViz Dual High
Configuration
Figure 7-16 Typical Parameter of Testing Dosage (NeuViz Dual High Configuration)
454110019578
REV.2.7 7-16 Quality Assurance
NeuViz Dual
User Manual
Head Scan Reconstruction Parameters of NeuViz Dual CT Scanner:
Unit:mGy
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 B1 B2 B3 B4 B5 CTDIw
Head(FOV250) 34.1 36.2 37.4 35.4 32.6 34.7
Body(FOV350) 22.5 19.1 26.3 22.3 10.9 18.7
Typical
120KV,150mA,2s,7mm
Parameters
CTDI100 of B5
Normalization Head (FOV250) Body (FOV350)
10mm 1.05 1.04
7mm 1 1
454110019578
REV.2.7 7-17 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-18 Quality Assurance
NeuViz Dual
User Manual
2) 7mm Slice
3) 0.8mm Slice
454110019578
REV.2.7 7-19 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-20 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-21 Quality Assurance
NeuViz Dual
User Manual
The impulse response and the tomographic thickness (slice thickness) are not
dependent upon the phantom dimensions. They are therefore measured on the
physics layer of the system phantom.
The phantom physics layer diameter is 200 mm diameter with PVC shell. The
impulse response is measured on a 0.18 mm copper wire using the Impulse
Response program.
The MTF curve is calculated from the impulse response on a separate
computer.
The maximum deviation of the MTF curve is ± 15%.
3. Tomographic Thickness Measurement
In the phantom shown in the Image Performance Quality Assurance chapter,
two aluminium strips at 45 deg. give projections of the sensitivity profile in the
image plane.
The profiles of the projections are equivalent to the sensitivity profiles, and the
FWHM of the profile is the nominal tomographic thickness.
The profile is measured by the Slice Width program.
The maximum deviation of the sensitivity profiles is 20%.
Notes: The 0.8 mm and 1.0 mm results appear wider than actual
with the ramp method due to the limited resolution of the
image and the thickness of the measuring ramp.
454110019578
REV.2.7 7-22 Quality Assurance
NeuViz Dual
User Manual
meters
1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5
454110019578
REV.2.7 7-23 Quality Assurance
NeuViz Dual
User Manual
meters
1.5 1.0 0.5 0.0 -0.5 -1.0 -1.5
454110019578
REV.2.7 7-24 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-25 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-26 Quality Assurance
NeuViz Dual
User Manual
X-ray and gamma rays are dangerous to both operator and others in the
vicinity unless established safe exposure procedures are strictly observed.
The useful and scattered beams can produce serious or fatal bodily injuries to
patients and persons in the surrounding area if used by an unskilled operator.
Adequate precautions must always be taken to avoid exposure to the useful
beam, as well as to leakage radiation from within the source housing or to
scattered radiation resulting from passage of radiation through matter.
Those authorized to operate, participate in or supervise the operation of the
equipment must be thoroughly familiar and comply completely with the current
established safe exposure factors and procedures described in publications,
such as the “Diagnostic X-ray systems and their major components,” section of
subchapter J of Title 21 of the Code of Federal Regulations, and the National
Council on Radiation Protection (NCRP) No 102, “Medical X-ray and gamma
ray protection for energies up to 10 MEV equipment design and use,” as
revised or replaced in the future.
In addition, operators are strongly urged to acquaint themselves with the
current recommendations of the International Commission on Radiological
Protection, and in the United States, with those of the US National Council for
Radiological Protection.
• ICRP, Pergamon Press, Oxford, New York, Beijing, Frankfurt, Sao
Paul, Sydney, Tokyo, Toronto
• NCRP, Suite 800, 7910 Woodmont Avenue, Bethesda, Maryland
20814, USA
Those responsible for the planning of X-ray and gamma ray equipment
installations must be thoroughly familiar and comply completely with NCRP No.
49, “Structural shielding design and evaluation for Medical of X-rays and
gamma rays of energies up to 10 MEV,” as revised and replaced in the future.
Failure to observe these warnings may cause serious or fatal bodily injuries to
the operator or those in the area.
454110019578
REV.2.7 7-27 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-28 Quality Assurance
NeuViz Dual
User Manual
454110019578
REV.2.7 7-29 Quality Assurance
NeuViz Dual
User Manual
4. Line Voltage and Regulation: Power supply input voltage is 3-Phase, 380
VAC ± 10%, nominal line-to-line, Delta or Wye, 49 to 51 Hz.
5. Line Current: Maximum line current is 85 A/phase(High Configuration)/ 61
A/phase(Low Configuration) at 380 V input voltage and 140 kV, 300 mA
(High Configuration)/ 140 kV, 200 mA (Low Configuration)
6. Technique Factor Criteria: measurements taken at 80% of peak voltage.
7.9.2 Generator Rating and Duty Cycle
X3601 made in SPELLMAN Co.,Ltd
Duty cycle: Intermittent load continuous operation, maximum transient load
ratio 12%
Rated input line voltage: 3-Phase, 380 VAC ± 10%,50/60Hz
Rated output voltage 140kV
454110019578
REV.2.7 7-30 Quality Assurance
NeuViz Dual
User Manual
Rated output current:300mA
Rated output power:42kw
NSG-T10028A made in PNMS
Duty cycle: Intermittent load continuous operation, maximum transient load
ratio 12%
Rated input line voltage: 342-420VAC, 3 phases,50/60Hz
Rated output voltage 140kV
Rated output current:200mA
Rated output power:28kw
7.9.3 Technique Factors – Maximum Deviations
1. X-Ray Tube Voltage
The X-ray voltage is displayed on the Operator Console Screen. The actual
X-ray voltage during scan is within ± 10% of the displayed value, which is in
the range of 80 to 140 kV.
The X-ray voltage is measured on a resistive divider, which is calibrated during
the manufacturing process.
2. X-Ray Tube Current – Exposure Time Product
The actual current – exposure time product (in mAs) during a scan is within
± 30% of the value displayed on the Operator Workstation screen. The tube
current – exposure time product is measured by a dosimeter calibrated in mAs.
The dosimeter is calibrated by measuring the tube anode current on Barracuda
between X-ray ON and OFF during a long exposure.
454110019578
REV.2.7 7-31 Quality Assurance
NeuViz Dual
User Manual
The system has two laser localizers on the gantry and it assists operator to
position the patient. Each localizer generates two perpendicular laser beams
The localization precision of the laser localizer is ± 1mm.
If one image generate during a circle, the laser localizer indicate the
constructed image position
If two images generate during a circle, the laser localizer indicate the middle
position of these two images.
454110019578
REV.2.7 7-32 Quality Assurance
NeuViz Dual
User Manual
The SD, as displayed on the screen, is divided, by (AV + 1000) and multiplied
by 100 to transform the CT numbers to a percentage of the material
absorption.
The region of interest of image can be selected by the measuring tool of CT
value in the interface of the console and the CT number of the ROI (region of
interest) selected is calculated from the average CT value of all pixels in the
ROI. The CT mean number of every pixel, as displayed on the screen, is
calculate from the following formula:
454110019578
REV.2.7 7-33 Quality Assurance
NeuViz Dual
User Manual
as the record
Quality assurance data can be stored in the normal patient scan format and
recalled at a later date. After loading the quality assurance image in the
interface of 2D image display and these quality assurance data can be
measured on images, these image marked with the data can be save in the
CD-ROM or Local disk or Removable disk through push the button “save
image” on the right side of the interface 2D image display. For the detail, please
refer to the chapter of image display in the instruction for uses 4541 100 19574
454110019578
REV.2.7 7-34 Quality Assurance
NeuViz Dual
User Manual
Appendix RecyclingPassport
To be removed
Batteries Type: Location
Lithium Coin Battery Figure 3
To be removed
I
NeuViz Dual
User Manual
II
NeuViz Dual
User Manual
Locations as mentioned in the Passport ( Pictures information)
PCB
PCB
PCB
Figure 1 CT system
Al、Pb
Fe、W
Oil
Fe
oil
Al
Pb
Fe
Pb
III
NeuViz Dual
User Manual
PCB
Fe Al
Al
PCB
Cu、Fe、Al
IV
NeuViz Dual
User Manual
Al
Cu
PCB
Fe
Al
Cu
Fe
V
NeuViz Dual
User Manual
Fe
Fe
PCB
Fe
VI
NeuViz Dual
User Manual
Fe
Al
PCB
Fe
VII
NeuViz Dual
User Manual
Cu
PCB
Fe
Cu
VIII
Neusoft Medical Systems Co., Ltd.
Address: No.3-11, Wenhua Road, Heping District, Shenyang,
Liaoning, China, 110004
Manufactured by Philips and Neusoft Medical Systems Co., Ltd.
Address: Neusoft Park, Hun Nan Industrial Area, Shenyang 110179,
China
EU REP: EMDAR BV
Address: Ijsselburcht 3
POB 5486
6802 EL Arnhem Subject to change
The Netherlands