Professional Documents
Culture Documents
NOVA_QUADRA_4+1+1K
NOVA_QUADRA_4+1+1K
D
F
B
645
290
1
1
TECHNICAL ROOM
499.5
85
203
20
514
C
B
2
2
88.5
88.5
88.5
88.5
88.5
185
20
20
20
20
20
293
325
325
325
325
325
325
325
325
10
390
390
390
390
390
183.5 20 53 20 183.5 183.5 20 53 20 183.5 183.5 20 53 20 183.5 FLOOR HEATING 183.5 20 53 20 183.5 183.5 20 53 20 183.5
PIPES - distance from
the floor heating
pipe to the drain
pipe needs to
be min. 10 cm DN20
10 10 10 10 10 10 10 10
WATER
A A
50
433
280
433
433
433
433
36.5 61 162.5
100
21.5
10
POWER
70
325
325
325
325
325
325
325
325
260
260
260
260
260
217.5 21
20
20
20
20
20
185
137
88.5
88.5
88.5
88.5
88.5
460 50 460 50 460 50 260 50 460 50 460 50
C
B
3
3
FOR LIGHTNING PROTECTION, STEEL CONSTRUCTION
NEED'S TO BE CONNECTED TO LIGHTNING ROD ON PLACES
MARKED WITH DOTS. ON STEEL COLUMNS, IT NEED'S TO BE
WELDED AND IN THE GROUND, TWO PEACES NEED TO BE
CONNECTED WITH CROSS CONNECTION AND AFTER THAT
SEALED WITH LEAD AND TAR.
LIGHTNING PROTECTION TAPE NEED'S TO BE PUT TO THE
BOTTOM OF FOUNDATION, WELD IT TO CONCRETE STEEL
EVERY 2-3m AND TAKE OUT CONNECTIONS TO STEEL
COLUMNS.
LIGHTNING PROTECTION TAPE IS MADE OF Fe/Zn 40x4mm.
4
drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc
FLOOR HEATING
PIPES - distance from
FOAM the floor heating
distance from the distance from the distance from the distance from the pipe to the drain distance from the distance from the distance from the distance from the
pipe needs to
floor heating pipe to floor heating pipe to floor heating pipe to floor heating pipe to be min. 10 cm DN20 floor heating pipe to floor heating pipe to floor heating pipe to floor heating pipe to
drain pipe Ø50 pvc
the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs
to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm
WATER
rain water pipe Ø110 pvc HIGH PR. FOAM HIGH PR. FOAM HIGH PR. FOAM HIGH PR. FOAM
distance from the
floor heating pipe to
the drain pipe needs drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc safety pipe Ø110 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc
to be min. 10cm
HIGH PR. rain water pipe Ø110 pvc rain water pipe Ø110 pvc NET
rain water pipe Ø110 pvc rain water pipe Ø110 pvc MULTIQUE MULTIQUE MULTIQUE QUADO
housing of the machine need's housing of the machine need's housing of the machine need's housing of the machine need's housing of the machine need's
to be connected to grounding to be connected to grounding to be connected to grounding to be connected to grounding to be connected to grounding
63
POWER
53
tube pvc Ø60 for cabel RST+N+Z
400V AC
tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z
400V AC 400V AC 400V AC 400V AC
main power cable tube Ø100
tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable
5
5
460 50 460 50 460 50 260 50 460 50 460 50
SECTION A-A
85
203
drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc
downfall downfall downfall downfall downfall downfall downfall downfall downfall downfall
20 20
20 20
20 20
20 20
20 20
20
3
3
40 11
40 11
100
100
100
100
100
100
72
72
72
72
72
80
60
60
60
60
60
20
20
20
20
20
183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50 260 50 183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50
6
433 650
137 70 100 50 293
POWER WATER
4.5 4.5 0.00
4.5
4.5
11
3
20
50
60
Ø16
75
72
77
downfall
DRAIN PIPE Ø160 pvc
5
30 20
20
7
7
8
8
A
D
B
F