Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A

D
F

B
645
290
1

1
TECHNICAL ROOM

499.5
85

203
20
514

460 50 460 50 460 50 260 50 460 50 460 50


650
510 510 310 1020

C
B
2

2
88.5

88.5

88.5

88.5

88.5
185
20

20

20

20

20
293
325

325

325

325

325

325

325

325
10

390

390

390

390

390
183.5 20 53 20 183.5 183.5 20 53 20 183.5 183.5 20 53 20 183.5 FLOOR HEATING 183.5 20 53 20 183.5 183.5 20 53 20 183.5
PIPES - distance from
the floor heating
pipe to the drain
pipe needs to
be min. 10 cm DN20

10 10 10 10 10 10 10 10

WATER
A A

50
433

280

433

433

433

433
36.5 61 162.5

100
21.5
10

POWER
70
325

325

325

325

325

325

325

325
260

260

260

260

260
217.5 21
20

20

20

20

20
185

137
88.5

88.5

88.5

88.5

88.5
460 50 460 50 460 50 260 50 460 50 460 50

510 510 310 510 510

C
B
3

3
FOR LIGHTNING PROTECTION, STEEL CONSTRUCTION
NEED'S TO BE CONNECTED TO LIGHTNING ROD ON PLACES
MARKED WITH DOTS. ON STEEL COLUMNS, IT NEED'S TO BE
WELDED AND IN THE GROUND, TWO PEACES NEED TO BE
CONNECTED WITH CROSS CONNECTION AND AFTER THAT
SEALED WITH LEAD AND TAR.
LIGHTNING PROTECTION TAPE NEED'S TO BE PUT TO THE
BOTTOM OF FOUNDATION, WELD IT TO CONCRETE STEEL
EVERY 2-3m AND TAKE OUT CONNECTIONS TO STEEL
COLUMNS.
LIGHTNING PROTECTION TAPE IS MADE OF Fe/Zn 40x4mm.

main water inlet tube 5/4"


4

4
drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc drain pipe Ø160 pvc

distance from the


floor heating pipe to
the drain pipe needs
to be min. 10cm

FLOOR HEATING
PIPES - distance from
FOAM the floor heating
distance from the distance from the distance from the distance from the pipe to the drain distance from the distance from the distance from the distance from the
pipe needs to
floor heating pipe to floor heating pipe to floor heating pipe to floor heating pipe to be min. 10 cm DN20 floor heating pipe to floor heating pipe to floor heating pipe to floor heating pipe to
drain pipe Ø50 pvc
the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs the drain pipe needs
to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm to be min. 10cm
WATER

rain water pipe Ø110 pvc HIGH PR. FOAM HIGH PR. FOAM HIGH PR. FOAM HIGH PR. FOAM
distance from the
floor heating pipe to
the drain pipe needs drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc safety pipe Ø110 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc
to be min. 10cm

HIGH PR. rain water pipe Ø110 pvc rain water pipe Ø110 pvc NET
rain water pipe Ø110 pvc rain water pipe Ø110 pvc MULTIQUE MULTIQUE MULTIQUE QUADO
housing of the machine need's housing of the machine need's housing of the machine need's housing of the machine need's housing of the machine need's
to be connected to grounding to be connected to grounding to be connected to grounding to be connected to grounding to be connected to grounding
63
POWER

drain pipe Ø50 pvc

53
tube pvc Ø60 for cabel RST+N+Z
400V AC

tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z tube pvc Ø60 for cabel RST+N+Z
400V AC 400V AC 400V AC 400V AC
main power cable tube Ø100

tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable tube Ø30 for R2W unitronic bus cable
5

5
460 50 460 50 460 50 260 50 460 50 460 50

485 510 510 310 510 510

- ALL RIGID ELEMENTS ARE DETAILED SHOWN IN CONSTRUCTION PROJECT


- ASPHALT LAYER NEED'S TO BE MADE WITH FALL TO THE DRAIN
- ALTITUDE OF ARRANGED ASPHALT LAYER NEED'S TO BE LEVELD WITH ROAD HIGHT
- RAIN WATER FROM THE STEEL STRUCTURE NEED'S TO BE LEAD TO COMMON DRAIN - DRAINAGE
WELLS

SECTION A-A
85
203

drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc drain pipe Ø50 pvc

downfall downfall downfall downfall downfall downfall downfall downfall downfall downfall
20 20

20 20

20 20

20 20

20 20

20
3

3
40 11

40 11
100

100

100

100

100

100
72

72

72

72

72

80
60

60

60

60

60
20

20

20

20

20

FUNDATION DEPTH ACCORDING TO GROUND


BEARING CAPACITY BUT NOT LESS THEN
80cm FROM PLATE TOP

510 510 510 310 510 510

183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50 260 50 183.5 20 53 20 183.5 50 183.5 20 53 20 183.5 50
6

SECTION B-B SECTION C-C


650

433 650
137 70 100 50 293
POWER WATER
4.5 4.5 0.00
4.5

4.5
11

3
20

50

60
Ø16
75
72

77

downfall
DRAIN PIPE Ø160 pvc
5
30 20

20
7

7
8

8
A
D

B
F

You might also like