Midea VRF Controller

Wired controller

Remote controller
Midea VRF Controllers
01 / Individual control

02 / Centralized control

03 / Network control

04 / Accessories

6
Individual Controller

RM02/E RM05 R51/E R06/E

Available for all the indoor units


Wireless Remote Controller

R51

Function:
•Mode Selection: Auto, Cool, Dry, Heat, Fan Only
•Temp. Setting Range: 17℃ To 30℃
•Daily Timer Setting
•Louver Swing
•Fan Speed Control: H/M/L/Auto
•*Eco operation mode
Eco

*The function with the star matches with the corresponding indoor units.
Wireless Remote Controller

RM05
Feature:
•Background light

Function:
• New appearance
• All basic functions is the same as R51/E
• For V4 plus indoor units, can set indoor units address

*The function with the star matches with the corresponding indoor units.
How to address via RM05
• *Address setting:
1.Pull the cover down , then use a pin press the
LOCK button for 5 seconds.
2. Press ON/OFF button one time
3. press up/down button can select the address
code
4. then press the FAN mode button can send the
address code to indoor unit wireless receiver,
and the indoor unit will make a beep sound
5. Press the LOCK button for 5 seconds to exit the
address setting mode

*The function with the star matches with the corresponding indoor units.
Wireless Remote Controller

RM02
Feature:
•Background-light display, compact dimension

Function:
•Mode selection: Auto, Cool, Dry, Heat, Fan only
• Temp. setting range: 17 ℃ to 30 ℃
• Eco operating mode
• One-key 26 ℃
• Keyboard locking
• Address setting( FAN SPEED+ECO for 5s)
• *FOLLOW ME
• **VR4+ auto mode
* Point the RM02 to the IDU to carry on the FOLLOW ME function.
**The function with the double star matches with the corresponding
indoor units.
BriefConclusion:
Brief conclusion
Function RM02 RM05 R51 R06

Time display × √ × ×

Controller lock √ √ √ √

Eco operation √ √ √ ×

Swing function √ √ √ √

Background-light √ √ √ √

Daily timer × × √ √

Address setting √ √ × ×

FOLLOW ME √ × × ×

Fan speed control √ √ √ √

Mode selection √ √ √ √
Wired Controller
KJR-10B/KJR-12B KJR-90A/ 90A1
Wired Controller
KJR-12B

• FOLLOW ME

• All basic function as the same as wireless remote controller R51


• Add a temperature sensor built-in and used for check ambient temp. of itself .
Detect the actual room temp around you then change the operating mode
Wired Controller

KJR-90A/E

Feature:
• All basic function as the same as KJR-10B
• Small size and Easy for installation
• The size is: 90*86*13 mm
98

• Can be put into electric cabinet


• Exquisite appearance and LCD display function
• Nine function buttons
90
• Applicable for all kinds of indoor units.
Wired Controller

KJR-90A1/E

Feature:
• Without mode select function
• Cooling only controller
1) Only can select ON/OFF, Temp, Swing, and Timer
2) Avoid mode conflict
• Other functions are the same with KJR-90A/E
Without
Mode
Selection
Wired Controller

KJR-120A/B-E

Feature:
• All basic function as the same as KJR-10B
• Real time display
• Check indoor unit status
• 10℃ heat function
• Cool-only or heat-only mode selection
• Auto mode for the VR4+ units
• Auto restart
• Filter cleaning reminder
Wiring diagram
Wired Controller

KJR-86

Feature:
• All basic control function
• One key 26℃
• Mode button hidden, avoid mode conflict
• Auto restart
• Press UP and DOWN button to select the mode
Wired Controller

KJR-29B

Feature:
• All basic control function
• One key 26℃
• Filter cleaning reminder
• Auto restart
• Wireless signal receiver
• Address setting
How to address via KJR-29B

*Address setting:
1. Press UP and DOWN buttons together for 8
seconds
2. Press ON/OFF button one time
3. press UP/DOWN button can select the address
number
4. Then press the MODE button can send the address
code to indoor unit wireless receiver, and the
indoor unit will make a beep sound
2. Press the OK button to exit the address setting

*The function with the star matches with the corresponding indoor units.
Wired Controller

KJR-29B KJR-29A
Brief Conclusion
Function KJR- KJR- KJR- KJR- KJR- KJR-29 KJR-86
10B 12B 90A 90A1 120A
Time display × √ × × √ √ ×
Controller lock √ √ × × √ √ ×
Eco operation √ √ × × √ × ×
Swing function √ √ √ √ √ √ ×
Error code × × × × √ × ×
display
Background × √ × × √ √ √
light
Daily timer √ × √ √ √ × ×
FOLLOW ME × √ × × × × ×
Fan speed √ √ √ √ √ √ √
control
Mode selection √ √ √ × √ √ ×
Centralized Controller

CCM03
Feature:
• Memory function: It can record the running
parameters (mode/fan speed/temp.) when using the
controller to turn on the indoor units, all the unit will
work as the last setting.
• Automatically record all setting info when lose
power
• RS485 communication
• Clear & bright LCD display screen,
• background light, more parameters display
• Emergency ON/OFF control with simple dry contact
input
Centralized Controller

Old
Under side outlet

• New structure doesn’t need to be embedded into the wall


• Shape is a regular cuboid , installation and put more convenient
• The wiring terminal is located in the control box body , improve the
safety and reliability
Centralized Controller

Address code: 0 ~ F

X, Y, E Terminals are at the back of CCM03.


(Connect to indoor units) Forced on

220V/AC

F1, F2, E
Emergency stop
(Connect to CCM03 or PC)
Centralized Controller
Lock RC

LOCK (Mode lock, lock remote controller, Increase / Decrease the setting temp. when SET
lock the Keyboard Scroll pages of parameters when QUERY

Set the mode Operation Mode setting

query the info of each


IDU Fan Speed Vary

UP, DOWN, LEFT, and


RIGHT TIMING ON/OFF

Re- search all indoor units, and


back the default setting Disable or Enable Swing Fan
Lock mode

LOCK (Mode lock, lock remote controller, Increase / Decrease the setting temp. when SET
lock the Keyboard Scroll pages of parameters when QUERY

Set the mode Operation Mode setting

query the info of each


IDU Fan Speed Vary

UP, DOWN, LEFT, and


RIGHT TIMING ON/OFF

2 1

Re- search all indoor units, and


back the default setting Disable or Enable Swing Fan
Lock keyboard

LOCK (Mode lock, lock remote controller, Increase / Decrease the setting temp. when SET
lock the Keyboard Scroll pages of parameters when QUERY

Set the mode Operation Mode setting

query the info of each


IDU Fan Speed Vary

UP, DOWN, LEFT, and


RIGHT TIMING ON/OFF

2 1

Re- search all indoor units, and


back the default setting Disable or Enable Swing Fan
CCM03 wiring diagram

X,Y, E F1,F2, E F1,F2, E F1,F2, E

X,Y, E X,Y, E X,Y, E X,Y, E


When one CCM03 connect to one refrigerant system, we can:

1.For the V4+ series product,


we can make the wiring simply
as this.

2.For other product, we can


use the traditional wiring
diagram to connect all the
indoor units.
When one CCM03 controller connecting more than one
refrigerant system, We can:

To connect the indoor ccm


controller via X Y E port of
master outdoor unit of every
refrigerant system.

However, the address of every


indoor unit must be set by
remote controller one by one
from0-63,

and notice that the address can


not be repeated. And notice
that the 3 of switch S6 should
be set ON, defining the mode
is no automatic searching
address.
Centralized Controller
CCM09
Feature:
• 7-days Weekly schedule setting
• Max. 64 indoor units group control or individual
setting
• Clear and bright screen
• with LCD backlight
• Temperature setting
• Wireless remote control restriction
• Sleep and Silent mode
• Mode lock
• Permanent schedule setting storage
 Weekly schedule • New structure as CCM03
controller
A possible schedule

If the air conditioner is running within the set period of the weekly timer and
there is other control device to control the air conditioner, the air-conditioner
will run according to the set parameter of the control devices (such as remote
controller, line controller and weekly-timer central controller) till to the next set
period of the weekly timer.
If the set mode of a period is Off, it means the weekly timer function of this
period is invalid.
CCM09 Wiring

To power
supply
To indoor unit
old

Remote ON/OFF

Communication interface to the fire control system:


COM+OFF Emergency Stop Switch; COM+ON Emergency Open Switch
Centralized controller

KJR-90B Feature:
• Centralized Control
Short press :
Only turn ON/OFF the last time operated indoor units.
Long press (3 seconds) :
Can Turn ON/OFF all indoor units.
• Operation Mode Selection Switch (Cooling, Heating)
• Overall/mono-control the indoor units
• Sleep function and memory function
25 seconds after operation, system would enter sleep
Max. 16 units mode, all indicators blink
Press any key to recovery the display.
• Compatible with central control.
Wiring Diagram
 Control at most 16 indoor units

Indication A1 A2 A3 A4 B1 B2 B3 B4

Network address 0 1 2 3 4 5 6 7

Indication C1 C2 C3 C4 D1 D2 D3 D4

Network address 8 9 10 11 12 13 14 15
Centralized Controller

KJRF-180A Feature:
• NEWLY deigned Indoor CCM, similar like CCM03
• Max. 16 IDUs (including one of them is Heat pump
water heater) group control
• Easier for installation in the wall. Complete cabinet
at the rear
• Suitable for the home comfort
• Multiple kind of indoor units control integrated
inside
• Auto restart
Centralized Controller

KJR-180A

NEW deigned Indoor CCM, similar like


CCM03,
Max. 16 IDUs (including one of them is Heat
pump water heater) group control
Easier for installation in the wall. Complete
cabinet at the rear
Home comfort

KJRF-180A is able to control multiple kinds of product.


Graceful appearance

KJRF-180A is designed with graceful appearance, especially suitable for the


high class environment.
Wiring diagram
Centralized controller

CCM02

Feature:
• RS485 communication
• Up to 8 systems, max.32 outdoor units can be
centralized monitored
• It can display the operating parameters of outdoor
units
• It can display the error or protection code of outdoor
units

Max. 8 systems
Address setting method

pressing the Address set button repeatedly ,the address will be increased one by one.
When the address is equal MAX.31and you press once more ,the address will restart
from16.
Indicator Display Address code: 16 ~ 31

Indicator lamp will be on when the CCM is power on.


CCM LOCKED
All the other button will not be on controlled anytime when pushing the CCM is locked,
and unlock happens when receiving the lock.
Electric energy consumption query
The Electric energy consumption can be queried through CCM when the outdoor unit
has its ammeter.
Wiring diagram Terminals are at the back of CCM02

F1, F2, E K1,K2,E


(connect to CCM02 or PC) (Connect to outdoor units)
Brief Conclusion:
Brief conclusion
Functions CCM03 CCM09 KJR-90B KJRF-180A CCM02
Time display × √ × √ ×
Controller lock × × × × ×
Query function √ √ × √ √
Swing function √ √ √ √ ×
Error code display √ √ × √ √
Background-light √ √ √ √ √
Weekly timer setting × √ × × ×

FOLLOW ME × × × × ×
Fan speed control √ √ × √ ×
Mode selection √ √ √ √ ×
Brief conclusion(continued):

Functions CCM03 CCM09 KJR-90B KJRF-180A CCM02


Auto restart √ √ × √ ×
Mode lock √ × × × ×
Access to PC √ × × × √
Max. unit controlled 64 64 16 16 32
BMS control application
Building Management System
Customer requirement: Control every parts of the building together
Security
Elevator

Power
Fire alarm

Light Air conditioner

Compatible with the main BMS systems, such as Johnson Controls, Siemens, Honeywell and
Schneider.
Network monitoring and gateway:

Gateways
Software

LonWorks New LonWorks


gateway CCM07 gateway
3rd generation network
monitoring system
4rd generation network
Monitoring system-
Intelligent Manager of Modbus Controlnet
gateway BACnet
Midea(IMM) gateway
gateway
CCM08
Gateway

CCM07

Feature:
• Cooperated with network software
• Connect Midea A/C system to BMS system
through LonWorks protocol

Available BMS

LonWorks Gateway
System sketch
Indoor side

Control system

Outdoor side
BMS gateway
Indoor side X, Y, E Max. 64 X, Y, E
units
CCM03

F1,F2,E

Max. 16
systems

X, Y, E Max. 64 X, Y, E
units
CCM03

F1,F2,E

PC
Outdoor side

PC
F1,F2,E

O,A,E O,A,E
CCM02
Max. 32
K1, K2, E units K1, K2, E

Max. 16
systems
F1,F2,E

O,A,E O,A,E
CCM02

Max. 32
K1, K2, E units K1, K2, E
Corresponding devices
 If you want to connect A/C system to BMS system (Lonworks with CCM07),
you can select:

 Midea Network control software (Necessary);


 CCM03 (Necessary);
 CCM02(necessary if select central monitor function or electricity charge
calculation);
 Electricity meter (necessary if select electricity charge calculation)

CCM07 is used together with the above accessories to realize BMS connection.
Gateway

CCM08 Feature:
• BACNET protocol network
• Max connecting 4 group air-conditions(each
group can connect Max.64 indoor units or 32 outdoor
units) directly
• Web Access Function

Available BMS

BACnet Gateway
System sketch
Web access

Change settings

Operation status
Corresponding devices
 If you want to connect A/C system to BMS system (BACnet), you can select:

 CCM03
 *CCM02(necessary if monitoring the ODU
or electricity fee calculation is needed)
 *Electricity meter(necessary if the
electricity fee calculation is needed)
 *Midea 3rd generation network monitoring
system(compatible with CCM08)

4 group interface : 4 CCMs (CCM02 or CCM03)


Each group including 64 indoor units or 32 outdoor units
Indoor units 4 × 64 , Limitation:256 Or outdoor units 4 × 32 , Limitation:128
CCM08 is used together with the above accessories to realize BMS connection.
Gateway

Feature:
• Bridge the Midea AC system to the Modbus BMS
• Compose a Modbus network of up to 1024 IDU
and 64 ODU
• Transfer in the RTU mode

Modbus Gateway
System sketch
Modbus master
Corresponding devices

 If you want to connect A/C system to BMS system via the Modbus gate way,
you can select:

 CCM03;
 CCM02
Gateway

Feature:
• Directly bridge the IDU to the LonWorks network
• One gateway bridge up to 64 IDU
• CCM03 is unnecessary

LonWorks Gateway
(MD-LonGW64/E)
System sketch

X/Y/E
BMS
(LonWorks ……
protocol)

X/Y/E

……

LonWorks bus
Accessories

Feature:
MD-NIM05 • A smart way to save energy and money.
When the Card Key is in place, the air conditioner is
activated.
When the Card Key is removed, the air conditioner
switches off, to avoid cooling an unoccupied room
and save energy.
• Special design for hotel guest room, working
with hotel card system .
• Notice : Suits all wired controller and KJR-10B
/12B / 90A wired controllers.
Hotel inserting card module
Hotel card-key
Hotel card-key

Indoor PCB
Receiver
Cable 1

KJR-10/12B
MD-NIM05
Accessories

Feature:
MD-NIM09  The infrared sensor is suitable to be used
in hotel, office, conference room,
residence, etc.
 When someone into the room, air
conditioning automatic startup, no one
activities will be off. It controls the AC’s
on/off by the infrared that our body has
delivered.
Function

Infra-red sensor installation place


should be the ceiling or wall with
centralized human activities
Wiring diagram

5-core wire connect


to wired controller
Accessories

KJR-32B
Feature:
• Design for outdoor alarm and monitoring
• Access to network monitoring system
• 220V power input
• 220V AC output for the alarm device

ODU alarm module


Accessories

DX AHU connection kit


Feature:
• Wired controller inside
• Display panel inside
• Temperature sensor inside
• EXV inside
• Compatible with other brand’s indoor units
• Access to network monitoring system
Connection
Midea VRF outdoor unit

Midea VRF indoor unit

DX AHU connection kit DX AHU


Composition EXV part Wired controller

Control part Sensors and wires

◆ Interface to allow other brand’s DX AHU connecting to Midea VRF outdoor


units.
◆ Used with this connection kit, can be allow other brand’s indoor units
connecting to Midea VRF outdoor units.
◆ DX AHU connection kit consist of control part, EXV part, temperature sensors
and wired controller.
Accessories

FCU connection kit


Feature:
• It’s used with the fan coil unit that without
the E-Box.
• By this control box fan coil can be
centralized controlled by a CCM03
• More flexible for the clients to use the FCU.
• Two models: 2-pipe type;4-pipe type.
Example
Accessories

Digital power meter

Feature:
• Calculate outdoor unit Electrical charge
• Notice: one outdoor unit cooperate one
digital Kilowatt Hour Meter
• Can be fixed inside the product in our
factory
• *Compatible power: 380V-3N~50Hz,
380V-3N~60Hz,
220V-3N~60Hz
* Different type power meters match different
power forms.
Applications

• We recommend:
 CCM03+CCM02+Control Software for whole hotel,
 KJR10+NIM05 + (KJR-90A1+KJR90B) for each room

 KJR90B for Mode lock & ON/OFF control for individual


room, and KJR-90A1 to change the setting temp.
 If required, KWH meter also can be provided.