FLOWSIC500 Parameter Report

ID_20240522101351
Device name ?L500???±ŸÊ-
?2ŸŸ°]ŸP Device Type Ultrasonic gas meter
Station / Description Manufacturer SICK
SN gas meter 23280611 Nominal Diameter DN100 | 4"
Device Type Key FL5-3E02B1E1A1X3B1F3D1G1C3N2XX Firmware Version 2.17.10
Company Firmware CRC 0xF1F9
Address Metrology CRC 0xE816
ZIP Code, City Adjust Parameter CRC 0x9EDA
Country Created with V1.24.0.9062
GPS Lat: 0.00 | Lon: 0.00

Meter Status Measurement valid

Identification Unit Value


SN adapter 23180001
SN gas meter 23280611
Limit Qmin acm/h 4
Limit Qmax acm/h 650

System Management Unit Value


RTC Timezone UTC-06:00
Counter Digits 9 Digit
Totalizer Volume m³/Cnt 1
Totalizer Norm. Vol. m³/Cnt 1000

Warning / Alert Settings Unit Value


Flow Limit Low acm/h 0
Flow Limit High acm/h 2000
Counter Vreverse max m³ 1
Low Flow Cut Off acm/h 1
Diagnostic Limit GQI % 3

Data Archive Settings Unit Value


Accounting Hour 6:00 AM
Log Gas Day 1
Log Measure Period min 60
Event Log Rolling

Pulse Settings Unit Value


Test Frequency Hz 10
Imp.Fact. Airtest Imp/m³ 8862

Interface Pulse 1 Settings Unit Value


Impulse Source Uncorrected volume
Impulse Max. Frequency Hz 2000
Frequency at Qr Hz 0.002166667
Impulse Factor Imp/m³ 0.01
Impulse Width ms 5

User Warnings Activation


o All errors o All warnings o Configuration mode o Power failure o Battery (1) failed
o Battery (2) failed o Battery low o Event log full o Event log capacity warning o Flow: sensor failure
o Flow: sensor warning o Flow: lower user limit o Flow: upper user limit o Reverse flow o Temperature: general failure
o Pressure: general failure o Compressibility calc. error o Pulse #1: frequency > fmax o Pulse #2: frequency > fmax o Gas quality

Correction Coefficients Column1 Column2 Column3 Column4


A-2 A-1 A0 A+1 A+2
0.000000e+000 0.000000e+000 0.000000e+000 0.000000e+000 0.000000e+000

Data date: 5/22/2024 10:13:51 AM Print date: 5/22/2024 10:13:53 AM Page 1 of 2


FLOWSIC500 Parameter Report
ID_20240522101351
Interface Communication Value
DO.2 Configuration Pulse 1
DO Status Activation Cycle Permanently active
DO Status Activation Duration Pulse duration: 1s

RS 485 col2 col3 col4


Address Slave Protocol Baudrate Protocol Modbus Config
1 MODBUS RTU 38400 8N1 FL500 (default)

Temperature Sensor Unit Value


Temp. Value Source EDT34
Serial No. Modbus T-Sensor 2084102057
Temperature OPRange Low °F -58
Temperature OPRange High °F 212
Fixed Temperature °F 68
Temperature Limit Low °F -14.8
Temperature Limit High °F 176
Adj. Offs. Ext. T-Sensor °F 32
Adjust Gain Extern. T-Sensor 1

Pressure Sensor Unit Value


Pressure Value Source EDT23 relative
Serial No. Modbus p-Sensor 1983900261
Min Operating Pressure psi(a) -21.529
Max Operating Pressure psi(a) 196.027
Fixed Pressure psi(a) 14.223
Pressure Limit Low psi(a) 11.023
Pressure Limit High psi(a) 420.609
Adj. Offs. Ext. p-Sensor psi 0
Adjust Gain Extern. p-Sensor 1

Volume Conversion Unit Value Gas composition mol% 2 3 4 5


EVC Method SGERG-88 H2 0 CO2 1.5 N2 1
Compressibility Default for EVC 1
Base Temperature °F 68
Base Pressure psi(a) 14.223
Atmosph. Pressure psi(a) 14.73
Density (Standard) kg/m³ 0.776
Relative Density for EVC 0.65
Gross Heating Value MJ/m³ 41.304

Current Events Information Recommended Action

1020 Open HW lock Close parameter lock in device.

Data date: 5/22/2024 10:13:51 AM Print date: 5/22/2024 10:13:53 AM Page 2 of 2