AUTOMATIC BARRIER OPERATOR

INSTRUC
DIGITAL LIMIT SWITCH

Gl3000

PLEASE READ THE MANUAL CAREFULLY


BEFORE INSTALL AND USE
Warnings to installers and users

1. Before installation and use, please read this Manual carefully.

2. Avoid installing the product where there are vibrations, high-


temperature, high-humidity, flammable, explosives, dust or corrosive
gases.
3. As there is high voltage electricity inside the product, non-
professionals should not arbitrarily open the lid to avoid electric
shock. For debugging, look for professionals for help.
4. For loss and damage due to unauthorized changes to the original
design of the product, the original manufacturer will assume no
liability or responsibility.
5. An air-break switch must be connected with the power supply
input connector.
6. Before power on and debugging controller, manually adjust the
barrier to the middle position.
7. The power must be cut off before manually operate the barrier.
8. Make sure that the path is unobstructed when the barrier is running.
9. Safety devices such as Air-wave switch and Photocell are highly
recommended. Check and test them periodically to ensure that they
are effective.
10. Please properly dispose the accessories including plastic bag and
screws to avoid the hazards such as mistaking and chocking.
11. Please keep this Manual properly for reference.

1
1. Descriptions

1.1 Technical Specifications

AC 220V 50/60Hz

-30℃ ~85℃
Remote frequency 433.92MHz

1.2 Main Features


1.21 Digital positioning, high precision, easy setting.
1.22 Intelligent self-checking and self-protection.
1.23 Delay automatic closing function.
1.24 Safety protection function is available by the
external sensors.
1.25 Remote control.
1.26 Rs485 terminal

1.3 Definitions of Control Buttons

Green Red Blue

Open/Increase Value Stop/Set/Save Close/Decrease Value

2
2. Electrical connections

DIGITAL PANEL

000000 Display Panel

LOOP DETE PRES.WAVE INFRARED LEARN

Setting Buttons
SET >> O_SPEED C_SPEED MODEL LEARN

Control Buttons

OPEN STOP CLOSE

Main Terminals (6 Bits) Default: ON


Power PE Motor
L N PE U V W
UP terminal(11bits) Down terminal(11bits)
EncoderB
External 485
External 485

EncoderA
Relay
Relay1
Relay2

Relay3
Relay3

Power GND
Power GND

Power GND
Power GND
Power GND

+12V +12V
+5V +5V

+
-
OPEN

LOOP
STOP

PHO
NO3
NO2

NC3

CLS
NO1
CM

PT

A2
B2

B
A

3
Control box of BS-SZB L
N N N N O S C P
C O P
O O O C P T L H
M O T
1 2 3 3 N P S O
P
G + G G G G +
P A B
L N U V W N 5 N N N N 12 A B
E 2 2
D V D D D D V

220V AC

G +
P
U V W N 12 A B
E
D V
Adapter board
Alarm light G +
P
U V W N 12 A B
E
D V

- + Yellow&Green Blue Brown White Black


Power
Supply

M ENCODER
Motor cover Inverter Motor
Alarm light

Accessories
~ ~ G
12 12 A N B
V V D
POWER MAX485

Note: Pls connect external accessories as alarm light or photocell as above drawing, working
current should be less than 2.5A, working voltage should be no more than 250V AC/30V DC

4
4. Remote controller operation

a) Learning transmitter code


Press “LEARN” button which on the main board for one
time, the LED will light, then press the button you desire on the
transmitter for one time, the LED will flash. Repeat these steps for more
transmitters.

Note: 1、The original transmitters has been matched the code, and users
do not need to do this.
2、New transmitters need to be set the steps as above.

b) Erasing transmitter code


If the transmitters are lost or illegally copied, please make
the operation of erasing code to clear all codes that stored in
the control box, after the operation, no transmitter can control
the barrier.
Press and hold the”LEARN” button to light the LED till go out.
Now, all stored codes of transmitters are erased.

5
5. Limits setting

Note: For the controller initially installed, manually adjust sliding gate to middle
position before power on.

Power on

Press and hold “SET” button till “P--1"


displays

Swap the any 2 of motor


wires: U, V, W.
Press “OPEN” button and watch the sliding gate

No Is the gate opening No Power off


Yes

Press and hold “OPEN” button till gate reaches open position
Yes

Press “SET” button one time and “P--2” will display

No
Note:
: Push ”STOP” button
Press and hold “CLOSE” button and watch the sliding gate to quit during setting
process, but no record.
No
After the quick setup as
Is the gate closing till the close position
above, the sliding gate can
Yes
run normally, please
Press”SET” button to confirm operate to open and
close the gate one time,
inspect if the limits setting
Press “STOP” button to quit is satisfied.

End

6
6. Delay automatically close setting

Function description: The sliding gate will automatically close after setting
when the gate is open fully.

Note1: The factory default value is “0”, means that the function is cancelled.
Note2: The maximum delay value is 99 seconds.

Power on

Press and hold “SET” button till “P--1”


displays.

Press “SET” button to switch parameter till “P--5” displays

Press “OPEN” or “CLOSE button


to adjust the parameter value.

Press”SET” button to confirm

Press “STOP” button to quit

End

Note: Press and hold “OPEN” or “CLOSE” button,


the parameter will increase or decrease.
Press “STOP” to quit during any interface.

7
7. Open / Close Speed setting

Power on

Press and hold “O_SPEED” button till a


value displays.(value is the current speed)

Press “OPEN” or “CLOSE” button


to adjust the value.

Press “SET” to confirm.

Press “STOP” to quit.

Note: Press and hold “OPEN” or “CLOSE” button,

End the parameter will increase or decrease .

9. Factory reset

Power on

Press and hold “SET+STOP+CLOSE” buttons Press “STOP” to quit.


together till “FFFF” displays.

Press and hold “SET” button, display value”1” Press “STOP” to quit.
press “CLOSE” to decrease the value to “0”

Press “SET” to confirm.

End

8
8
9. Trouble Shooting

*No power 220V input *Check the power supply


No display after power on *Wrong power-line connection *Check the connection
*The fuse blew out *Check the fuse

Display error code Refer to Error codes table Refer to Error codes table

*Low battery *Change a new battery


Remote doesn’t work *Weak signal *Far away from disturbance sources
*Water inside or damaged *Change a new remote

Motor can’t run Motor wires are short circuit Check the wiring

9. Error Code Table

Error Code Description Error Code Description


Er02 Speed up overcurrent Er15 External fault

Er03 Speed down overcurrent Er17 Relay fault


Constant speed Abnormal current
Er04 overcurrent Er18 detection
Er05 Speed up overvoltage Er19 Abnormal motor tuning
Speed down overvoltage
Abnormal read and write
Er06 Er21 of EEPROM
Constant speed Inverter hardware
Er07 overvoltage Er22 failure
Abnormal brake power Motor short circuit to
Er08 supply Er23 ground
Er09 Undervoltage fault Er33 Running overtime

Er10 Overloaded inverter Er34 Obstacle during opening

Er11 Overloaded motor Er35 Sensor fault

Er12 Non-full-phase of input Er36 Limit fault


Internal communication
Er13 Non-full-phase of output Er37 fault
Er14 Module is overheating

9
9.Soft start
control boxsetting(Just
have this the single phase
function)
10. Function Codes Table

Code Description Mark

P--01 Open limit setting Get the open limit value

P--02 Close limit setting Get the close limit value

P--03 Loop detector mode 0: normal mode, 1: counter mode

P--05 Delay automatically close time setting Default: 0, range: 0--999

U--00 Max open speed The bigger, the faster,


value is from the minimum to 140
U--01 Max close speed The bigger, the faster,
value is from the minimum to 140
U--02 Start position of opening soft stop Range: 0--4095

U--03 Start position of closing soft stop Range: 0--4095

U--04 Speed up time 1 Range: 0--2000.0

U--05 Speed down time 1 Range: 0--2000.0

U--06 Speed up time 2 Range: 0--2000.0

U--07 Speed down time 2 Range: 0--2000.0

U--08 Min opening speed Range: 0.0--max opening speed

U--09 Min closing speed Range: 0.0--max closing speed

U--10 Stop position of opening soft stop Range: 0--4095

U--11 Stop position of closing soft stop Range: 0--4095

U--12 Obstacle time Range: 0--9999

U--13 Obstacle current Range: 0--10.99


Fine tuning the open limit, the smaller,
U--14 the closer to open limit.
Fine tuning the close limit, the smaller,
U--15 the closer to close limit.

U--16 Limit learning speed

10
Code Description Mark

U--18 Time of open overtime Range: 1--999S

U--19 Time of close overtime Range: 1--999S

U--20 Address Address of external RS485


0: normal mode,
U--21 Test mode 1: automatic operating mode
U--23 Max frequency Max frequency of inverter