TEMPERATURE TRANSMITTER

INSTRUMENT DATA SHEET


DOC. NO. NY-TOS-CO-INX213-C15-0001 (012)

CLIENT TANJUNG OFFSHORE SERVICES SDN BHD


OWNER VALEURA ENERGY INC
PROJECT PROVISION OF MOBILE OFFSHORE PRODUCTION UNIT FOR NONG YAO EXTENSION PROJECT
P.O. NO. T7GGMPGPO23-0054

1 Index No 18
2 Tag Number TIT-4102
GENERAL 3 P&ID No NY-MOPU-TOS-T-B-PID-0006
DATA 4 Line / Equipment No 8"-PT-10029-15C35X-HE
5 Service From Coriolis Meter (FIT-4101) to Barred Tee
6
7 Fluid State Hydrocarbon Gas/Liquid
8 Design Pressure Min Max. Unit --- 2,200 psig
9 Design Temperature Min Max. Unit --- 230 °F
PROCESS
10 Operating Pressure Operating Temp. 400 psig 179.4 °F
CONDITIONS
11 Density Viscosity 23.19 lb/ft3 0.014/2.855 cP
12 Flow Velocity 10.33 ft/s
13
14 Model Suffix YTA610-JA1A4DN/A/X2/C3/KU2
15 Instrument Range Min Max. Unit -328 1,562 °F
16 Calibration Range Min Max. Unit 0 250 °F
17 Sensor Element Sensor Input RTD (Pt100) Single Element
1
18 D/A Accuracy Total Accuracy2 ± 0.03% of Span ±0.1% of Span
19 Cold Junction Comp. SIL Level Not Applicable SIL 2
20 Power Supply Output Signal 24 VDC; Loop-Powered 4-20 mA DC (HART 7)
21 Housing Material Cast Al. Alloy with Anti-Corrosion Coating
22 Electrical Connection Enclosure Protection M20X1.5P IP 66/67
23 Indicator Bar Graph LCD Indicator Yes
TRANSMITTER 24 Electrical Protection Class ATEX Flameproof Approval
25 II 2 G Ex db IIC T6/T5 Gb
26 II 2 D Ex tb IIIC T70°C/T90°C Db
27 ATEX Intrinsically Safe Approval
28 II 1 G Ex ia IIC T5 T4 Ga
29 II 2 (1) D Ex ia [ia Da] IIIC T135°C Db
30 Installation Type Linearization Integral Type Yes
31 Ambient Temp. Limit Min Max. Unit -22 176 °F
32 Failure Alarm (NAMUR NE43) Up-Scale : 110%, 21.6 mA DC or More
33 Sensor Burnout High : 110%, 21.6 mA DC
34
35 Element Single / Duplex Pt100 Single
36 Type Current Limit 3-Wire 1mA
37 Standard Code Accuracy Class IEC 60751 Class A
38 Sheath Material Sheath Diameter SS 316L 6.0 mm
39 Instrument Conn. Spring Loaded 1/2" NPT-M Yes
TEMPERATURE
40 Nipple Length Nipple Material 100 mm SS 316
ELEMENT
41 Terminal Head Electrical Connection --- ---
42 Enclosure Protection IP 66
43 Electrical Protection Class II 2G Ex db eb IIC T6...T1 Gb
44 II 2D Ex tb IIIC T110°C Db
45
46 Construction Thermowell Material Tapered Shank SS 316
47 Process Connection Flange Material Lap Joint SS 316
48 Size Rating Face 1.5" ASME 1500# RTJ
49 Standard U-Length 260 mm
50 Root Diameter Tip Diameter 30 mm 18 mm
THERMOWELL
51 Bore Diameter Tip Thickness 6.5 mm 5 mm
52 Nozzle Length NACE Compliance 150 mm MR0175
53 Instrument Conn. Welding Type 1/2" NPT-F ---
54 Painting System Plug & Chain --- Yes
55
56 Sunshade Mounting Bracket --- ---
ACCESSORIES 57 Surge Protector Wired SS Tag Plate Built-In ---
58
59 Calibration and Test Certificates Yes 5-Points Calibration
60 Material Certificates Yes Acc. EN10204 Type 3.1
61 Pressure/Leak Test Report Yes
CERTIFICATION
62 Dye Penetration Test Report ---
63 Positive Material Identification Test Report Yes
64
NOTES :
1) D/A Accuracy : Accuracy when converting signal from digital to analog 1 03/01/24 As-Built LTY FCY
2) Total Accuracy : A measure of total performance of analog-to-digital (A/D) conversion, 0 22/12/23 Appr. for Construction LTY FCY
2) digital-to-analog (D/A) conversion and/or cold junction compensation accuracy B 27/11/23 Issued for Review LTY FCY
Rev. Date Description Prepared Checked

You might also like