Professional Documents
Culture Documents
Safaricom Ethiopia Wakanda OSP Project HW STEP HW G655D Core10 a-B
Safaricom Ethiopia Wakanda OSP Project HW STEP HW G655D Core10 a-B
General Information
File name: Safaricom Ethiopia Wakanda OSP Project_HW_STEP_HW G655D_Core10_A-B.sor
Test date: 6/24/2024 Customer: STEP
Test time: 7:26:56 AM Company: HW
Cable ID: HW G655D Fiber ID: Core10
Job ID: Safaricom Ethiopia Wakanda OSP Project
Comments:
Locations
Location A Location B
EEP OPGW JB2 (KOKA
Location Natherth I DWDM (407077)
Dxn)
Operator
Model FTBx-735C-SM2-OPM-EA
Serial number 1390437
Calibration date 9/28/2020 (UTC)
Results
Span length: 1.1399 km Average loss: 0.957 dB/km Injection level: 14.1 dB
Span loss: 1.091 dB Average splice loss: 0.611 dB
Span ORL: 40.94 dB Maximum splice loss: 0.611 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 29.042 dB/km A-B average loss: 26.078 dB/km
a 0.5002 14.020 A-B LSA loss: 14.528 dB 4-point Event Loss: 12.678 dB
A 0.9998 13.045 A-B ORL: 45.03 dB Maximum reflectance: -48.0 dB
B 1.5000 0.000
b 2.0003 3.174
Macrobend
Position (km) Delta Loss (dB)
Pass/Fail Thresholds
1550 nm (9 µm)
Splice loss (dB) 0.100
Connector loss (dB) 0.750
Splitter loss (dB) 5.000
Reflectance (dB) -60.0
Fiber section attenuation (dB/km) 0.250
Span loss (dB) 20.000
Span ORL (dB) 15.00
Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 2.5000
Pulse (ns) 5
Duration (s) 10
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000