Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR Report (1550 nm (9 µm)) Fail

General Information
File name: Safaricom Ethiopia Wakanda OSP Project_HW_STEP_HW G655D_Core1t_A-B.sor
Test date: 6/24/2024 Customer: STEP
Test time: 7:44:53 AM Company: HW
Cable ID: HW G655D Fiber ID: Core1
Job ID: Safaricom Ethiopia Wakanda OSP Project
Comments:

Locations
Location A Location B
EEP OPGW JB2 (KOKA
Location Natherth I DWDM (407077)
Dxn)
Operator
Model FTBx-735C-SM2-OPM-EA
Serial number 1390437
Calibration date 9/28/2020 (UTC)

Results
Span length: 13.8997 km Average loss: 0.348 dB/km Injection level: 23.8 dB
Span loss: 4.837 dB Average splice loss: 0.087 dB
Span ORL: 32.91 dB Maximum splice loss: 0.116 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.595 dB/km A-B average loss: 4.115 dB/km
a 0.5002 23.648 A-B LSA loss: 0.298 dB 4-point Event Loss: 0.820 dB
A 0.9998 24.715 A-B ORL: 48.90 dB Maximum reflectance: -64.7 dB
B 1.5000 22.656
b 2.0003 22.539

Signature: _______________________________ Date: 6/24/2024 Page 1 of 2


OTDR Report (1550 nm (9 µm)) Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -87.5 0.000
Section 0.9947 0.213 0.214 0.213
Reflective 2 0.9947 0.794 -64.6 1.007
Section 3.6579 0.692 0.189 1.699
Non-Reflective 3 4.6526 0.116 1.815
Section 2.8903 0.546 0.189 2.361
Non-Reflective 4 7.5429 0.064 2.425
Section 5.3347 0.992 0.186 3.417
Non-Reflective 5 12.8776 0.101 3.517
Section 0.3190 0.077 0.242 3.594
Reflective 6 13.1966 0.982 -32.7 4.577
Section 0.5998 0.163 0.271 4.739
Non-Reflective 7 13.7964 0.067 4.806
Section 0.1034 0.031 0.302 4.837
Reflective 8 13.8997 --- -33.9 4.837

Macrobend
Position (km) Delta Loss (dB)

Pass/Fail Thresholds
1550 nm (9 µm)
Splice loss (dB) 0.100
Connector loss (dB) 0.750
Splitter loss (dB) 5.000
Reflectance (dB) -60.0
Fiber section attenuation (dB/km) 0.250
Span loss (dB) 20.000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 20.0000
Pulse (ns) 50
Duration (s) 10

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 6/24/2024 Page 2 of 2