Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

XFP 80C CB1 50HZ

Head
Testnorm
H /m -3 ∆p / MPa
ISO9906:2012,HI 11.6/14.6≤10kW
0,11
11 PE
22
/4- 0,1
10 C-5
0H
Z 0,09
9
8.92 0.087
8 A1 0,08

7 0,07
70,6%
6 0,06

5 0,05

4 0,04

3 0,03

2 0,02

1 0,01
▕◄ Application range ►▏
0 0
P ₂ / kW Shaft power P2

1,8
1.758
1,6

1,4

1,2
NPSH / m NPSH-values

2
1.17 1

0 10 20 30 42 50
40 60 70 80 90 100 110 120 130 140 Q / m³/h
2024-02-02

Operating data specification Power input 2,02 kW


Flow 42 m³/h Head 8,92 m
Efficiency 58,1 % Rated power 1,76 kW
NPSH 1,17 m Fluid Wastewater
Temperature 40 °C Nature of system Single head pump
No. of pumps 1
Pump data
Type XFP 80C CB1 50HZ Make SULZER
Series XFP PE1-PE3 Impeller Contrablock Plus impeller, 1 vane
N° of vanes 1 Impeller size 185 mm
Free passage 75 mm Suction flange DN100
Discharge flange DN80 Type of installation
Moment of inertia 0,0142 kg m² Wet Well installation with pedestal
Motor data
Rated voltage 400 V Frequency 50 Hz
Rated power P2 2,2 kW Nominal Speed 1440 1/min
Number of poles 4 Efficiency 86,8 %
Power factor 0,8 Rated current 4,6 A
Starting current 29,8 A Rated torque 14,6 Nm
Starting torque 21,2 Nm Degree of protection IP 68
Insulation class H No. starts per hour 15
Sulzer reserves the right to change any data and dimensions without prior notice Spaix® 4, Version 4.3.12 - 2020/05/29 (Build 328)
and can not be held responsible for the use of information contained in this software. Data version Aug 2020
Curve number
Pump performance curves
Reference curve
XFP80C-CB XFP 80C CB1 50HZ
Discharge Frequency
DN80 50 Hz
Density Viscosity Testnorm Rated speed Date
992,3 kg/m³ 0,6503 mm²/s ISO9906:2012,HI 11.6/14.6≤10kW 1454 1/min 2024-02-02
Flow Head Shaft power Power input Rated power P2 Hydraulic efficiencyNPSH
42 m³/h 8,92 m 1,76 kW 2,02 kW 2,2 kW 58,1 % 1,17 m

H /m Head -3 ∆p / MPa
11,5
0,11
11
PE 0,105
10,5 22/
4-C 0,1
10 -50
HZ
0,095
9,5
0,09
9
8.92 0.087
0,085
8,5
A1 0,08
8
0,075
7,5
0,07
7
0,065
6,5 70,6%
0,06
6
5,5 0,055

5 0,05
4,5 0,045
4 0,04
3,5 0,035
3 0,03
2,5 0,025
2 0,02
1,5 0,015
1 0,01
0,5 0,005
▕◄ Application range ►▏
0 0
P ₂ / kW Shaft power P2

2
1,9
1,8
1.758
1,7
1,6
1,5
1,4
1,3
1,2

NPSH / m NPSH-values

4,5
4
3,5
3
2,5
2
1,5
1.17
1
0,5

0 10 20 30 4042 50 60 70 80 90 100 110 120 130 140 150 Q / m³/h

Impeller size N° of vanes Impeller Solid size Revision


185 mm 1 Contrablock Plus impeller, 1 vane75 mm
Sulzer reserves the right to change any data and dimensions without prior notice Spaix® 4, Version 4.3.12 - 2020/05/29 (Build 328)
and can not be held responsible for the use of information contained in this software. Data version Aug 2020
Frequency PE1
50 Hz Motor performance curve
PE22/4-C-50HZ

Rated power Service factor Nominal Speed Number of poles Rated voltage Date
2,2 kW 1 1440 1/min 4 400 V 2024-02-02
0 10 20 30 40 50 60 70 80 90 100 110 120 130 P2/P2n / %

n / 1/min 79,89 % - cos φ P ₁ / kW


2000 -n 3,5
- I/In 1,3 3,4
1900 -s 3,3
1,25
-P ₁ 3,2
1800 - M/Mn 1,2
3,1
-η 1,15
1700 3
1,1 2,9
1600 2,8
1,05
2,7
1500 1 2,6
1454 0% 25% 50% 0,95 2,5
1400 75% 100%
A1 125% 2,4
0,9
1300 2,3
0,85 2,2
1200 0,8 2,1
0.757 22.021
0,75
1100 1,9
0,7 1,8
1000
0,65 1,7
900 0,6 1,6
1,5
0,55
800 1,4
0,5 1,3
700 1,2
0,45
1,1
600 0,4
1
0,35 0,9
500
0,3 0,8
400 0,7
0,25
0,6
300 0,2 0,5
0,15 0,4
200
0,3
0,1
100 0,2
0,05 0,1
0 0 0
0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1.758
1,8 2 2,2 2,4 2,6 2,8 P ₂ / kW

Symbol No load 25 % 50 % 75 % 100 % 125 %


P₂ / kW 0 0,55 1,1 1,65 2,2 2,75
P₁ / kW 0,1646 0,6889 1,264 1,895 2,534 3,135
η/ % 0 79,84 87,05 87,08 86,81 87,74
n / 1/min 1500 1489 1474 1457 1439 1419
cos φ 0,09926 0,3813 0,6017 0,7398 0,8016 0,8195
I/ A 2,394 2,608 3,031 3,697 4,564 5,52
s/% 0 0,7635 1,719 2,839 4,09 5,418
M / Nm 0 3,528 7,125 10,81 14,6 18,51

Tolerance according toVDE 0530 T1 12.84for rated power


Starting current Starting torque Moment of inertia No. starts per hour
29,8 A 21,2 Nm 0,008 kg m² 15
Sulzer reserves the right to change any data and dimensions without prior notice Spaix® 4, Version 4.3.12 - 2020/05/29 (Build 328)
and can not be held responsible for the use of information contained in this software. Data version Aug 2020

You might also like