Product Description
AquaArm Purtech H 1 is a two component, spray applied fast setting coating based out of modified polyurethane/ Hybrid
Polyurea Hybrid to achieve an elastic, high crack bridging waterproofing coating with long life expectancy.
Application Methodology
Step no 1: Surface Preparation:
All surfaces should be clean, dry and free from dust and All delaminated and splashed areas of concrete shall be
other contaminants. repaired prior to application of AquaArm Purtech H 1.
Treat oil or grease contamination with degreaser
followed by water or steam cleaning. Wall to floor Joints, corners and dynamic cracks etc.
Surface shall be thoroughly cleaned, dry and free of require to be fixed with the SealArm tape 2000 using
dust, loose cement mortar, grease, oil, and other ReArm Bond 4031 before application of AquaArm
contaminants. Purtech H 1.
Ver/5/HM/July 2020 1 of 3
Waterproofing Systems
AquaArm Purtech H 1
(Formerly known as AquaArm Gepotech H 2)
Typical Properties
Shore A Hardness (ASTM D 2240) ~ 75
Step no 3: Preparation prior to processing:
Shore D Hardness (ASTM D 2240) ~ 25
2
The component A must be stirred for 10 to 15 minutes Tensile strength (ASTM D 412) >12 N/mm
using a suitable propeller stirrer. The component B does Elongation at break (ASTM D 412) > 500 %
not require stirring.
Recovery at 100 % Elongation
>85 %
(ASTM D 412)
Working equipment: Impact resistance (ASTM D2794) >10 Nm
To apply AquaArm Purtech H 1 heatable two component Tear Strength (ASTM D 624) >30 N/mm
high pressure spray equipment is required. We 0
Fully cured at 27 C >72 Hrs
recommend: Duo Mix 2K-apparatus from IMT.
0
Resistance to chemicals at 27 C >72 Hrs
Both components are to be brought to an operating Fire behavior (EN 13501-1) Class E
temperature of approx. +60° – +70°C over separate
heating elements, in order to achieve the optimum Resistance to root penetration
Passes
(DIN 4062 ( ch.5.7))
viscosity. The tempered material is transported via a
heated pipe feeder. During the application the Capillary water absorption 0.5
0.002 Kg/m²/h
temperature is kept constant. (EN 1062-3)
Water vapor permeability
The two components are mixed together in the mixing Class I
(EN ISO 7783-1)
head of the spray gun and must be carried out at a CO2 permeability (SD)
>120 M
pressure of >170 Bar. Tools must be cleaned (EN 1062-6 method A)
immediately with an organic solvent. Pipe work can be Adhesion to concrete >1.5 N/mm
2
rinsed out e.g. with Mesamoll. Cured residues can only (ASTM D 4541-02) (concrete failure)
be mechanically removed
Adhesion to steel 2
>10 N/mm
(ASTM D 4541-02)
Abrasion resistance
(Taber H22, 1000 g, 300 c) >300 mg
Technical Data (ASTM D 4060-10)
Electrical surface resistance
>1 Giga ohm
(EN 1081-1988)
Physical Properties
Flexibility
Characteristics Value (over 3 mm mandrel) Passes
Type Hybrid (ASTM D 522)
Skid resistance
Solids content 100% Dry: 50, Wet: 20
(ASTM E 303-93)
VOC (ASTM D 2369) Nil Service temperature (Dry)
0
-20 C to + 80 C
0
AquaArm Purtech H 1
(Formerly known as AquaArm Gepotech H 2)
Annotation
Avoid direct sunlight.
The Substrate must be dry & inaccessible to other agencies
during the application of material.
Avoid spray application when rain is approaching.
Legal Note
The information, and, in particular, the recommendations relating to the application and end-use of MYK Arment products, are given in good
faith based on MYK Arment current knowledge and experience of the products when properly stored, handled and applied under normal
conditions in accordance with MYK Arment’s recommendations. In practice, the difference in materials, substrates and actual site conditions
are such that no warranty in respect of merchant ability or of fitness for a particular purpose, nor any liability arising out of any legal
relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered.
The user of the product must test the product's suitability for the intended application & purpose. MYK Arment reserves the right to change the
properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale
and delivery. Users must always refer to the most recent issue of the local product data sheet for the product concerned, copies of which will
be supplied on request.
Ver/5/HM/July 2020 3 of 3