PROPERTY LINE BOUNDARY

SECTION
0.25

0.20
3"Ø FABRICATED STEEL EYE BOLT

CL CL 0.20
3"Ø FABRICATED STEELl EYE BOLT

0.25 0.25

1" ENTRANCE CAP (MERALCO SUPPLY)

1.80
1.40
LINESIDE WIRES - NO.8 MINIMUM GROUND WIRE

Variable Height (Verify Road Traffic Design) VARIABLE HIEGHT (Verify Road Traffic Design)

DRIP LOOP - 0.60M


LINESIDE CONDUIT, 1" RSC PIPE PROPERTY LINE BOUNDARY

0.30
1" METAL CLAMP
F.F.L.

Variable Heigh (Verify Road Traffic Design)


MERALCO METER BASE SOCKET PANEL BOX

Variable
Variable

1" x 1/2" G.I. BUSHING REDUCER SEE DETAIL A' LIGHTING CONTROL POWER OUTLET PANEL BOARD
4 - 10MM DEFORMED STEEL BARS, VERTICAL BARS
1/2" PVC MALE ADAPTER
1" PVC ELBOW
Maximum Height of Meter Base : 1.83m

TYPICAL MOUNTING HEIGHT DETAIL


3.70

Maximum Height of Meter Base : 1.83m


1/2" PVC CLAMP, ORANGE
Minimum Height of Meter Base : 1.52m 10MM DEFORMED STEEL BARS, LATERAL TIES SPACED
Minimum Height of Meter Base : 1.52m @ 1 - 0.05O, 1 - 0.100, REST @ 0.200 M.O.C.
PVC RIGID PIPE ORANGE, 1.50M X 1/2"
SCALE: NTS
GROUND CLAMPS (Galvanized Steel)

1.80M
1.83

Note:
No.8 TW Wire (Ground Wire)
1.52

GROUND ROD (Galvanized Steel)


1" PVC PIPE
5 - 10MM DEFORMED STEEL BARS B.W.
Natural Grade Line

0.48m MIN.
2" THICK GRAVEL BEDDING
1" PVC LONG ELBOW 1" PVC LONG ELBOW

0.60
0.60

0.20
0.20

HOUSE 1

0.05
0.80
SERVICE ENTRANCE HEIGHT (Road Traffic Design) LOADSIDE WIRES - NO.8 Minimum Ground Wire
SECTION
3.10m - (For Sidewalks & Pedestrians traffic only) 4 - 10MM DEFORMED STEEL BARS, VERTICAL BARS
PROPERTY LINE BOUNDARY
3.70m - (For Residential & Commercial driveways, No trucks) 0.50m MIN. DISTANCE FROM PERPENDICULAR WALL 0.25 10MM DEFORMED STEEL BARS, LATERAL TIES SPACED
@ 1 - 0.05O, 1 - 0.100, REST @ 0.200 M.O.C.
5.50m - (For Public Road, Alley, truck & non-residential driveway)
Variable (Verify Front Setback) 5 - 10MM DEFORMED STEEL BARS B.W.
7.40m - (Crossing National Highway)

0.80
ELECTRICAL SERVICE ENTRANCE LAYOUT DETAIL

0.20
SCALE: NTS 0.80
HOUSE SERVICE WIRE
STRUCTURAL DETAILS

FROM MERALCO
1"RSC PIPE
ELECTRICAL SERVICE ENTRANCE DETAIL PROPERTY LINE
SETBACK FOR UTILITIES
SUPPLY
SINGLE PHASE, SCALE: NTS HOUSE 1
60 Hz, 230 V 2-NO.8 TW WIRE SERVICE WIRE
M 1-NO.8 TW GROUND WIRE

ENTRANCE POLE KEY DIAGRAM


SCALE: NTS
SCHEDULE OF LOADS AND COMPUTATION
40A,2P 15A,2P
CKT. NO. DESCRIPTION OF LOADS NO.OF OUTLET VA VA/CKT VOLTAGE IL/CKT BRANCH PROTECTION WIRES & CONDUIT
MAIN1 2 LIGHTING 1 MAIN CKT. 40 AMP 2- #8 TW STRANDED; 1- #8 TW GRND. WIRE
20A,2P 2 CEILING LIGHT OUTLET 8 100 800 230 3.48 15 AMP 2- #14 TW IN 1/2"Ø PVC RIGID CONDUIT

CONVENIENCE3 3 CONVENIENCE OUTLET (2ND) 6 360 2160 230 9.39 20 AMP 2- #12 TW IN 1/2"Ø PVC RIGID CONDUIT
4 SPARE
OUTLET 4 SPARE
5 SPARE
SPARE5 6 SPARE
6 SPARE
POWER CONNECTED LOAD 280 2960 230 12.87
DEMAND FACTOR 100%
1- NO.8 TW TOTAL POWER CONNECTED LOAD 2960
GROUND WIRE
IN 13MMØ COMPUTATION :
RIGID PVC PIPE IL = 6400 = 29.60 AMP (100% DF)
230V HOUSE 1
SERVICE WIRE
WIRE SIZE : USE 2-NO.8 TW COPPER WIRE(STRANDED)ON 1"RIGID PVC CONDUIT,WITH 1-NO.8 TW COPPER
SINGLE LINE DIAGRAM WIRE(STRANDED)GROUND LINE ON 13mmØ RIGID PVC CONDUIT
FOR MAIN CB : USE 2P 40 AT/100 AF 230V CB
NOTES:
SCALE: NTS FOR DUPLEX - 1 POLE: 2 UNITS
FOR TOWNHOUSE - 1 POLE: 4 UNITS

POLE PLAN PER UNIT


SCALE: NTS

DESIGNER / CONTRACTOR: DESIGNER / ENGINEER-IN-CHARGE: I M P O R T A N T: PROJECT TITLE: OWNER: REVISION/S: DATE/S: CADD BY: SHEET CONTENT/S: SHEET NO. :
STRUCTURAL DETAILS
PROPOSED KITCHEN EXTENSION WITH E-02
ENGR. JAYPEE Z. JAVIER
CIVIL ENGINEER FENCE & GATE
PRC.NO.: PTR NO: PROJECT LOCATION: APPROVED BY OWNER: 02 02
VALIDITY: ISSUED ON: PROPOSED PLAN
B26 L22 MAGENTA ST, PH-2, TIERRA VISTA, BRGY, SANTIAGO GENERAL TRIAS
TIN: ISSUED AT: STRUCTURAL PLAN