Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

Hybrid AIR Description

Description

Ge22577B

298/1551-LZA 701 6001/1 Uen H


Copyright

© Ericsson AB 2021. All rights reserved. No part of this document may be


reproduced in any form without the written permission of the copyright owner.

Disclaimer

The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use of this
document.

Trademark List

All trademarks mentioned herein are the property of their respective owners.
These are shown in the document Trademark Information.

298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Contents

Contents

1 Product Overview 1
1.1 Main Features 1
1.2 Required Installation Equipment 1

2 Technical Data 3
2.1 Bands, Carriers, and Output Power 3
2.2 Passive Antenna 5
2.3 Physical Characteristics 10
2.4 Installation Requirements 18
2.5 Installation Alternatives 18
2.6 Space Requirements 19
2.7 Wind Load 19
2.8 Acoustic Noise 22
2.9 Environmental Characteristics 22
2.10 Power Supply Characteristics 24
2.11 System Characteristics 24

3 Hardware Architecture 25
3.1 Hybrid AIR Unit Parts 25

4 Connection Interfaces 26
4.1 Grounding Interface 26

5 Standards and Regulations 27


5.1 Regulatory Approval 27
5.2 Other Standards and Regulations 28

298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Hybrid AIR Description

298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Product Overview

1 Product Overview

Hybrid AIR is an combination of active-passive antenna system. It is a single unit


that includes AIR unit, passive antenna, mechanical spine, and a radome.

The Hybrid AIR unit is designed for outdoor installations, intended for pole
mounting.

For general information on the AIR product, see Antenna Integrated Radio Unit
Description in the Hardware Antenna System, Battery, Enclosure, Power, Radio,
RAN Compute library.

1.1 Main Features


Active Unit

— LTE TDD, NR TDD, and multistandard mixed mode LTE + NR

— 3-wire (DC-I) and 2-wire (DC-C) power connection

— eCPRI

Passive Unit

— 10, 12, 16 ports, 5, 6, 8 antenna arrays (dual polarization)

— Adjustable electrical down tilt (FlexRet)

1.2 Required Installation Equipment


For detailed information on electrical and optical cables, see Site Installation
Products Overview in the Hardware Antenna System, Battery, Enclosure, Power,
Radio, RAN Compute library.

Table 1 Mounting Kit


Unit Type Mounting Kit Description Product Number
Mounting Clamps Clamps 55–115 Pole clamps for 85010096
mm XH tilt or azimuth
adjustment
Clamps 110–220 85010097
mm XH
Clamps 210–380 85010101
mm XH

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 1


Hybrid AIR Description

Unit Type Mounting Kit Description Product Number


Down Tilt Kit Down Tilt Kit XH Kit for down tilt 85010099
adjustment
Up Tilt Joint Up Tilt Joint Up tilt joint for 85010112
XM/XH down tilt kit XH
Azimuth Azimuth Kit for azimuth 85010098
Adjustment Kit Adjustment Kit adjustment
XH(1)(2)
(1) It is not allowed to combine the azimuth adjustment kit XH and the down tilt kit XH for the
Hybrid AIR solution.
(2) It is not allowed to combine the azimuth adjustment kit XH and the up tilt kit XH for the Hybrid
AIR solution.

Table 2 Possible Combinations of the Mounting Hardware


Clamps 55– Clamps Clamps Up Tilt Joint Down Tilt Kit Azimuth
115 mm XH 110–220 210–380 XM/XH XH Adjustment
85010096 mm XH mm XH 85010112 85010099 Kit XH
85010097 85010101 85010098
Clamps 55– Possible Possible Possible
115 mm XH - - -
85010096
Clamps Possible Possible Possible
110–220
mm XH - - -
85010097
Clamps Possible Possible Possible
210–380
mm XH - - -
85010101
Up Tilt Joint Possible Possible Possible Possible Not allowed
XM/XH -
85010112
Down Tilt Kit Possible Possible Possible Possible Not allowed
XH -
85010099
Azimuth Possible Possible Possible Not allowed Not allowed
Adjustment
Kit XH -
85010098

2 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

2 Technical Data

This section describes the physical characteristics, environmental data, and the
power supply characteristics of the Hybrid AIR unit.

2.1 Bands, Carriers, and Output Power


This section shows data on bands, carriers, and output power according to the
Hybrid AIR.

Table 3 Technical Data


Description Value
Maximum nominal output AIR 3227 B42 200 W
power
AIR 3227 B43 200 W
(1)
AIR 3227 B78T 200 W
AIR 3278 B78K 200 W
AIR 6449 B42 320 W
AIR 6449 B43 280 W
AIR 6449 B77D 320 W
AIR 6449 B78M 240 W
License key is required for total output power over
20 W.
Passive antenna can have up to 1000 W.
Number of carriers AIR 3227 B42 LTE: Up to four
NR: Up to two
AIR 3227 B43 NR: Up to two
AIR 3227 B78T NR: Up to two
AIR 3278 B78K NR: Up to two
AIR 6449 B42 LTE: Up to five
NR: Up to two
Mixed mode: Up to six
AIR 6449 B43 LTE: Up to three
NR: Up to two
Mixed mode: Up to four
AIR 6449 B77D NR: Up to two

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 3


Hybrid AIR Description

Description Value
AIR 6449 B78M NR: Up to two
LTE: Up to three
Mixed mode: Up to four
Frequency AIR 3227 B42 NR, LTE: 3400–3600
(2)
MHz
AIR 3227 B43 NR: 3600–3800 MHz
AIR 3227 B78T NR: 3410–3610 MHz
AIR 3278 B78K NR: 3420–3800 MHz
AIR 6449 B42 NR, LTE: 3400–3600
MHz
AIR 6449 B43 NR, LTE: 3600–3800
MHz
AIR 6449 B77D NR: 3700–3980 MHz
AIR 6449 B78M NR (single and mixed
mode), LTE: 3450–
3650 MHz
16 Port Antenna R1 698–960 MHz
800482021 R2 698–960 MHz
B1 1427–2180 MHz
B2 1427–2180 MHz
Y1 2490–2690 MHz
Y2 1695–2690 MHz
Y3 1695–2690 MHz
Y4 2490–2690 MHz
16 Port Antenna R1 698–960 MHz
800442008 R2 698–960 MHz
Y1 1695–2690 MHz
Y2 1427–2690 MHz
Y3 1695–2690 MHz
Y4 2490–2690 MHz
Y5 1695–2690 MHz
Y6 1427–2690 MHz
12 Port Antenna R1 698–960 MHz
800482001 R2 698–960 MHz
800482002 Y1 1427–2690 MHz

4 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Description Value
Y2 1695–2690 MHz
Y3 1695–2690 MHz
Y4 1427–2690 MHz
10 Port Antenna R1 698–960 MHz
800442004 R2 698–960 MHz
Y1 1427–2690 MHz
Y2 1695–2690 MHz
Y3 1427–2690 MHz
(1) For detailed information about licenses and HWAC, see:

NR: Manage Licenses and Hardware Activation Codes in the NR RAN library.

LTE: Manage Licenses and Hardware Activation Codes in the LTE RAN library.
(2) For information about IBW, see Radio Node Configurations.

2.2 Passive Antenna

R1+ Y1+ Y2+ Y3+ R2+

L 1 L 5 C 7 R 9 R 3
698 960 1427 2690 1695 2690 1427 2690 698 960

R1– Y1– Y2– Y3– R2–

L 2 L 6 C 8 R 10 R 4
698 960 1427 2690 1695 2690 1427 2690 698 960

Ge22708B

Figure 1 Connection Interface of the Passive Antenna 800442004

The passive antenna has 4.3–10 female connectors.

Table 4 Passive Antenna 800442004


10-Port R1 R2 Y1 Y2 Y3
Antenna
Frequency 698–960 698–960 1427– 1695– 1427–
Range 2690 2690 2690
(MHz)

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 5


Hybrid AIR Description

10-Port R1 R2 Y1 Y2 Y3
Antenna
Dual X X X X X
Polarizatio
n
HPBW 65° 65° 65° 65° 65°
Gain (dBi) 14.7 14.6 17.8 17.7 17.6
Adjust. 2°–14° 2°–14° 2°–12° 2°–12° 2°–12°
Electrical
Downtilt

Y1+ Y2+ R1+ R2+ Y3+ Y4+

L 5 CL 7 L 1 R 3 CR 9 R 11
1427 2690 1695 2690 698 960 698 960 1695 2690 1427 2690

Y1– Y2– R1– R2– Y3– Y4–

L 6 CL 8 L 2 R 4 CR 10 R 12
1427 2690 1695 2690 698 960 698 960 1695 2690 1427 2690

Ge22709C

Figure 2 Connection Interface of the Passive Antenna 800482001

The passive antenna has 4.3–10 female connectors.

Table 5 Passive Antenna 800482001


12-Port R1 R2 Y1 Y2 Y3 Y4
Antenna
Frequenc 698–960 698–960 1427– 1695– 1695– 1427–
y Range 2690 2690 2690 2690
(MHz)
Dual X X X X X X
Polarizati
on
HPBW 65° 65° 65° 65° 65° 65°
Gain 14.6 14.8 17.8 17.4 17.2 17.8
(dBi)
Adjust. 2°–12° 2°–12° 2°–12° 2°–12° 2°–12° 2°–12°
Electrical
Downtilt

6 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

B1+ Y1+ Y2+ R1+ R2+ Y3+ Y4+ B2+

L 5 L 9 CL 11 L 1 R 3 CR 13 R 15 R 7
1427 2180 2490 2690 1695 2690 698 960 698 960 1695 2690 2490 2690 1427 2180

B1– Y1– Y2– R1– R2– Y3– Y4– B2–

L 6 L 10 CL 12 L 2 R 4 CR 14 R 16 R 8
1427 2180 2490 2690 1695 2690 698 960 698 960 1695 2690 2490 2690 1427 2180

Ge20039B

Figure 3 Connection Interface of the Passive Antenna 800482021

The passive antenna has 4.3–10 female connectors.

Table 6 Passive Antenna 800482021


16- R1 R2 B1 B2 Y1 Y2 Y3 Y4
Port
Anten
na
Freque 698– 698– 1427– 1427– 2490– 1695– 1695– 2490–
ncy 960 960 2180 2180 2690 2690 2690 2690
Range
(MHz)
Dual X X X X X X X X
Polariz
ation
HPBW 65° 65° 65° 65° 65° 65° 65° 65°
Gain 14.9 14.9 16.8 16.8 17 17.6 17.6 17
(dBi)
Adjust. 2°– 2°– 2°– 2°– 2°– 2°– 2°– 2°–
Electri 12° 12° 12° 12° 12° 12° 12° 12°
cal
Downt
ilt

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 7


Hybrid AIR Description

Y1+ Y1– Y5+ Y5–

L 5 L 6 R 13 R 14
1695 2690 1695 2690 1695 2690 1695 2690

R1+ Y2+ Y3+ Y4+ Y6+ R2+

L 1 L 7 C 9 C 11 R 15 R 3
698 960 1427 2690 1695 2690 1695 2690 1427 2690 698 960

R1– Y2– Y3– Y4– Y6– R2–

L 2 L 8 C 10 C 12 R 16 R 4
698 960 1427 2690 1695 2690 1695 2690 1427 2690 698 960

Ge23064A

Figure 4 Connection Interface of the Passive Antenna 800442008

The passive antenna has 4.3–10 female connectors.

Table 7 Passive Antenna 800442008


16- R1 R2 Y1 Y2 Y3 Y4 Y5 Y6
Port
Anten
na
Freque 698– 698– 1695– 1427– 1695– 1695– 1695– 1427–
ncy 960 960 2690 2690 2690 2690 2690 2690
Range
(MHz)
Dual X X X X X X X X
Polariz
ation
HPBW 65° 65° 65° 65° 65° 65° 65° 65°
Gain 15.7 15.7 15.9 16.2 16.3 16.3 15.9 16.2
(dBi)
Adjust. 2.5°– 2.5°– 2°– 2°– 2°– 2°– 2°– 2°–
Electri 11.5° 11.5° 12° 12° 12° 12° 12° 12°
cal
Downt
ilt

8 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Left Right
Y1+ Y2+ R1+ R2+ Y3+ Y4+

L 5 CL 7 L 1 R 3 CR 9 R 11
1427 2690 1695 2690 698 960 698 960 1695 2690 1427 2690

Y1– Y2– R1– R2– Y3– Y4–

L 6 CL 8 L 2 R 4 CR 10 R 12
1427 2690 1695 2690 698 960 698 960 1695 2690 1427 2690

Ge23211A

Figure 5 Connection Interface of the Passive Antenna 800482002

The passive antenna has 4.3–10 female connectors.

Table 8 Passive Antenna 800482002


12-Port R1 R2 Y1 Y2 Y3 Y4
Antenna
Frequenc 698–960 698–960 1427– 1695– 1695– 1427–
y Range 2690 2690 2690 2690
(MHz)
Dual X X X X X X
Polarizati
on
HPBW 65° 65° 65° 65° 65° 65°
Gain 15.9 15.8 17.9 17.6 17.5 17.8
(dBi)
Adjust. 2.5°– 2.5°– 2°–12° 2°–12° 2°–12° 2°–12°
Electrical 11.5° 11.5°
Downtilt

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 9


Hybrid AIR Description

2.3 Physical Characteristics

W D

Ge22800B

Figure 6 Hybrid AIR Unit Dimensions

Table 9 Hybrid AIR Unit Dimensions


Unit Type Height (H) mm Width (W) mm Depth (D) mm
Hybrid AIR 3227 B42 2202 448 234
15P2L3M
Hybrid AIR 3227 B43 2202 448 234
15P2L3M
Hybrid AIR 3227 B78T 2202 448 234
15P2L3M
Hybrid AIR 3278 B78K 2280 488 234
15P2L3M
Hybrid AIR 6449 B42 2414 448 234
15P2L3M
Hybrid AIR 6449 B43 2414 448 234
15P2L3M

10 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Unit Type Height (H) mm Width (W) mm Depth (D) mm


Hybrid AIR 6449 B77D 2414 448 234
15P2L3M
Hybrid AIR 6449 B78M 2414 448 234
15P2L3M
Hybrid AIR 3227 B42 2202 488 234
15P2L6M
Hybrid AIR 3227 B43 2202 488 234
15P2L6M
Hybrid AIR 3227 B78T 2202 488 234
15P2L6M
Hybrid AIR 3278 B78K 2280 488 234
15P2L4M
Hybrid AIR 6449 B42 2414 488 234
15P2L6M
Hybrid AIR 6449 B43 2414 488 234
15P2L6M
Hybrid AIR 6449 B77D 2414 488 234
15P2L6M
Hybrid AIR 6449 B78M 2414 488 234
15P2L6M
Hybrid AIR 3227 B42 2202 488 234
15P2L4M
Hybrid AIR 3227 B43 2202 488 234
15P2L4M
Hybrid AIR 3227 B78T 2202 488 234
15P2L4M
Hybrid AIR 3278 B78K 2280 488 234
15P2L6M
Hybrid AIR 6449 B42 2414 488 234
15P2L4M
Hybrid AIR 6449 B43 2414 488 234
15P2L4M
Hybrid AIR 6449 B77D 2414 488 234
15P2L4M
Hybrid AIR 6449 B78M 2414 488 234
15P2L4M
Hybrid AIR 3227 B42 2691 496 412
20P2L4M
Hybrid AIR 3227 B43 2691 496 412
20P2L4M

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 11


Hybrid AIR Description

Unit Type Height (H) mm Width (W) mm Depth (D) mm


Hybrid AIR 3227 B78T 2691 496 412
20P2L4M
Hybrid AIR 3278 B78K 2774 496 412
20P2L4M
Hybrid AIR 6449 B42 2908 496 412
20P2L4M
Hybrid AIR 6449 B43 2908 496 412
20P2L4M
Hybrid AIR 6449 B77D 2908 496 412
20P2L4M
Hybrid AIR 6449 B78M 2908 496 412
20P2L4M
Hybrid AIR 3227 B42 2657 456 412
20P2L6M
Hybrid AIR 3227 B43 2657 456 412
20P2L6M
Hybrid AIR 3227 B78T 2657 456 412
20P2L6M
Hybrid AIR 3278 B78K 2740 456 412
20P2L6M
Hybrid AIR 6449 B42 2874 456 412
20P2L6M
Hybrid AIR 6449 B43 2874 456 412
20P2L6M
Hybrid AIR 6449 B77D 2874 456 412
20P2L6M
Hybrid AIR 6449 B78M 2874 456 412
20P2L6M

12 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Ge23069A

Figure 7 Hybrid AIR Unit Dimensions

Table 10 Hybrid AIR Unit Dimensions


Unit Type Height (A) mm Height (B) mm Height (C) mm
Hybrid AIR 3227 B42 308 1452 443
15P2L3M
Hybrid AIR 3227 B43 308 1452 443
15P2L3M
Hybrid AIR 3227 B78T 308 1452 443
15P2L3M
Hybrid AIR 3278 B78K 308 1530 443
15P2L3M
Hybrid AIR 6449 B42 325 1646 443
15P2L3M
Hybrid AIR 6449 B43 325 1646 443
15P2L3M
Hybrid AIR 6449 B77D 325 1646 443
15P2L3M
Hybrid AIR 6449 B78M 325 1646 443
15P2L3M

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 13


Hybrid AIR Description

Unit Type Height (A) mm Height (B) mm Height (C) mm


Hybrid AIR 3227 B42 308 1452 443
15P2L6M
Hybrid AIR 3227 B43 308 1452 443
15P2L6M
Hybrid AIR 3227 B78T 308 1452 443
15P2L6M
Hybrid AIR 3278 B78K 308 1530 443
15P2L4M
Hybrid AIR 6449 B42 325 1646 443
15P2L6M
Hybrid AIR 6449 B43 325 1646 443
15P2L6M
Hybrid AIR 6449 B77D 325 1646 443
15P2L6M
Hybrid AIR 6449 B78M 325 1646 443
15P2L6M
Hybrid AIR 3227 B42 308 1452 443
15P2L4M
Hybrid AIR 3227 B43 308 1452 443
15P2L4M
Hybrid AIR 3227 B78T 308 1452 443
15P2L4M
Hybrid AIR 3278 B78K 308 1530 443
15P2L6M
Hybrid AIR 6449 B42 325 1646 443
15P2L4M
Hybrid AIR 6449 B43 325 1646 443
15P2L4M
Hybrid AIR 6449 B77D 325 1646 443
15P2L4M
Hybrid AIR 6449 B78M 325 1646 443
15P2L4M
Hybrid AIR 3227 B42 314 1796 543
20P2L4M
Hybrid AIR 3227 B43 314 1796 543
20P2L4M
Hybrid AIR 3227 B78T 314 1796 543
20P2L4M
Hybrid AIR 3278 B78K 314 1875 543
20P2L4M

14 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Unit Type Height (A) mm Height (B) mm Height (C) mm


Hybrid AIR 6449 B42 331 1991 543
20P2L4M
Hybrid AIR 6449 B43 331 1991 543
20P2L4M
Hybrid AIR 6449 B77D 331 1991 543
20P2L4M
Hybrid AIR 6449 B78M 331 1991 543
20P2L4M
Hybrid AIR 3227 B42 314 1830 543
20P2L6M
Hybrid AIR 3227 B43 314 1830 543
20P2L6M
Hybrid AIR 3227 B78T 314 1830 543
20P2L6M
Hybrid AIR 3278 B78K 314 1909 543
20P2L6M
Hybrid AIR 6449 B42 331 2025 543
20P2L6M
Hybrid AIR 6449 B43 33 2025 543
20P2L6M
Hybrid AIR 6449 B77D 331 2025 543
20P2L6M
Hybrid AIR 6449 B78M 331 2025 543
20P2L6M

Table 11 Hybrid AIR Unit Weight


Unit Type Weight without Mounting Kit (1)
Hybrid AIR 3227 B42 15P2L3M 88
Hybrid AIR 3227 B43 15P2L3M 89
Hybrid AIR 3227 B78T 15P2L3M 91
Hybrid AIR 3278 B78K 15P2L3M 94
Hybrid AIR 6449 B42 15P2L3M 104
Hybrid AIR 6449 B43 15P2L3M 104
Hybrid AIR 6449 B77D 15P2L3M 104
Hybrid AIR 6449 B78M 15P2L3M 104
Hybrid AIR 3227 B42 15P2L6M 98

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 15


Hybrid AIR Description

Unit Type Weight without Mounting Kit (1)


Hybrid AIR 3227 B43 15P2L6M 99
Hybrid AIR 3227 B78T 15P2L6M 101
Hybrid AIR 3278 B78K 15P2L6M 104
Hybrid AIR 6449 B42 15P2L6M 114
Hybrid AIR 6449 B43 15P2L6M 114
Hybrid AIR 6449 B77D 15P2L6M 114
Hybrid AIR 6449 B78M 15P2L6M 114
Hybrid AIR 3227 B42 15P2L4M 95
Hybrid AIR 3227 B43 15P2L4M 96
Hybrid AIR 3227 B78T 15P2L4M 98
Hybrid AIR 3278 B78K 15P2L4M 101
Hybrid AIR 6449 B42 15P2L4M 111
Hybrid AIR 6449 B43 15P2L4M 111
Hybrid AIR 6449 B77D 15P2L4M 111
Hybrid AIR 6449 B78M 15P2L4M 111
Hybrid AIR 3227 B42 20P2L4M 106
Hybrid AIR 3227 B43 20P2L4M 107
Hybrid AIR 3227 B43 20P2L4M 109
Hybrid AIR 3278 B78K 20P2L4M 112
Hybrid AIR 6449 B42 20P2L4M 122
Hybrid AIR 6449 B43 20P2L4M 122
Hybrid AIR 6449 B77D 20P2L4M 122
Hybrid AIR 6449 B78M 20P2L4M 122
Hybrid AIR 3227 B42 20P2L6M 65
Hybrid AIR 3227 B43 20P2L6M 66
Hybrid AIR 3227 B78T 20P2L6M 68
Hybrid AIR 3278 B78K 20P2L6M 71
Hybrid AIR 6449 B42 20P2L6M 80
Hybrid AIR 6449 B43 20P2L6M 80
Hybrid AIR 6449 B77D 20P2L6M 80
Hybrid AIR 6449 B78M 20P2L6M 80
(1) Total Weight (kg) without mounting brackets

16 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Table 12 Mounting Kit Weight


Unit Type Product Number Weight (kg)
Mounting Clamps 85010096 5
85010097 9.7
85010101 14.6
Down Tilt Kit 85010099 10.6
Azimuth Adjustment Kit 85010098 3.3

Note: Mounting clamps are used in combination with the down tilt or azimuth
adjustment kit.

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 17


Hybrid AIR Description

2.4 Installation Requirements


The Hybrid AIR unit must be mounted vertically on a pole with XH type
brackets. Use of other mounting brackets is not allowed.

2.5 Installation Alternatives

Ge22561B

Figure 8 Installation Method Alternatives

Table 13 Installation Alternatives


Installation Method Description
A Pole installation (pole with circular
cross section)
Minimum outer dimension Ø 55–380 mm

18 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

1 0 ° – 12 °
2

0 ° – 2.5 ° without uptilt joint


0 ° – 12 ° with uptilt joint
Ge22575C

2.6 Space Requirements


The AIR unit is installed with the cable connections facing down. Allow enough
free space below the Hybrid AIR unit to ensure sufficient working space.

2.7 Wind Load


This section shows the wind load data of the Hybrid AIR unit.

Table 14 Wind Load


Unit Type Wind Load (at 42 m/s) Survival Wind
Speed (m/s)
Frontal 0° Lateral Maximal
(N) 90° (N) 0-45° (N)
Hybrid AIR 3227 B42 840 643 1104 67
15P2L3M

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 19


Hybrid AIR Description

Unit Type Wind Load (at 42 m/s) Survival Wind


Speed (m/s)
Frontal 0° Lateral Maximal
(N) 90° (N) 0-45° (N)
Hybrid AIR 3227 B43 840 643 1104 67
15P2L3M
Hybrid AIR 3227 B78T 840 643 1104 67
15P2L3M
Hybrid AIR 3278 B78K 875 670 1151 67
15P2L3M
Hybrid AIR 6449 B42 933 713 1226 67
15P2L3M
Hybrid AIR 6449 B43 933 713 1226 67
15P2L3M
Hybrid AIR 6449 B78M 933 713 1226 67
15P2L3M
Hybrid AIR 6449 B77D 933 713 1226 67
15P2L3M
Hybrid AIR 3227 B42 1055 644 1194 67
15P2L6M
Hybrid AIR 3227 B43 1055 644 1194 67
15P2L6M
Hybrid AIR 3227 B78T 1055 644 1194 67
15P2L6M
Hybrid AIR 3278 B78K 1105 672 1252 67
15P2L6M
Hybrid AIR 6449 B42 1161 715 1314 67
15P2L6M
Hybrid AIR 6449 B43 1161 715 1314 67
15P2L6M
Hybrid AIR 6449 B78M 1161 715 1314 67
15P2L6M
Hybrid AIR 6449 B77D 1161 715 1314 67
15P2L6M
Hybrid AIR 3227 B42 1055 644 1194 67
15P2L4M
Hybrid AIR 3227 B43 1055 644 1194 67
15P2L4M
Hybrid AIR 3227 B78T 1055 644 1194 67
15P2L4M
Hybrid AIR 3278 B78K 1105 672 1252 67
15P2L4M

20 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Unit Type Wind Load (at 42 m/s) Survival Wind


Speed (m/s)
Frontal 0° Lateral Maximal
(N) 90° (N) 0-45° (N)
Hybrid AIR 6449 B42 1161 715 1314 67
15P2L4M
Hybrid AIR 6449 B43 1161 715 1314 67
15P2L4M
Hybrid AIR 6449 B78M 1161 715 1314 67
15P2L4M
Hybrid AIR 6449 B77D 1161 715 1314 67
15P2L4M
Hybrid AIR 3227 B42 1308 803 1481 67
20P2L4M
Hybrid AIR 3227 B43 1308 803 1481 67
20P2L4M
Hybrid AIR 3227 B78T 1308 803 1481 67
20P2L4M
Hybrid AIR 3278 B78K 1353 830 1533 67
20P2L4M
Hybrid AIR 6449 B42 1424 850 1613 67
20P2L4M
Hybrid AIR 6449 B43 1424 850 1613 67
20P2L4M
Hybrid AIR 6449 B77D 1424 850 1613 67
20P2L4M
Hybrid AIR 6449 B78M 1424 850 1613 67
20P2L4M
Hybrid AIR 3227 B42 1034 790 1359 67
20P2L6M
Hybrid AIR 3227 B43 1034 790 1359 67
20P2L6M
Hybrid AIR 3227 B78T 1034 790 1359 67
20P2L6M
Hybrid AIR 3278 B78K 1070 817 1407 67
20P2L6M
Hybrid AIR 6449 B42 1129 861 1484 67
20P2L6M
Hybrid AIR 6449 B43 1129 861 1484 67
20P2L6M
Hybrid AIR 6449 B77D 1129 861 1484 67
20P2L6M

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 21


Hybrid AIR Description

Unit Type Wind Load (at 42 m/s) Survival Wind


Speed (m/s)
Frontal 0° Lateral Maximal
(N) 90° (N) 0-45° (N)
Hybrid AIR 6449 B78M 1129 861 1484 67
20P2L6M

2.8 Acoustic Noise


The AIR unit has no active cooling components. It can emit low levels of acoustic
noise when operating on low capacity.

The sound pressure level when operating on low capacity is less than 28 dBA at
1-meter distance and hemispherical distribution, and 25 dBA for spherical
distribution.

2.9 Environmental Characteristics


This section contains operating environment data for the Hybrid AIR unit.

2.9.1 Operating Environment


The following are the values for the normal operating environment of the Hybrid
AIR:

Temperature −40 to +55°C


Maximum temperature change 1.0°C/min

2.9.2 Heat Dissipation


The Hybrid AIR unit is convection cooled. Avoid indoor installation in a room
without adequate ventilation and cooling.

Table 15 Heat Dissipation of the AIR Unit


Unit Output Power (W) Maximum Heat
Dissipation (W)
AIR 3227 B42 200 800
AIR 3227 B43 200 800
AIR 3227 B78T 200 800
AIR 3278 B78K 200 800
AIR 6449 B42 320 943
AIR 6449 B43 280 1013

22 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Technical Data

Unit Output Power (W) Maximum Heat


Dissipation (W)
AIR 6449 B77D 320 1013
AIR 6449 B78M 240 1419

Table 16 Heat Dissipation of the Passive Antenna


Passive Antenna Passive Antenna Output Power Maximum Heat
(W) Dissipation (W)
10-Port Passive 800442004 - 200
Antenna
12-Port Passive 800482001 - 210
Antenna
12-Port Passive 800482002 - 280
Antenna
16-Port Passive 800482021 - 230
Antenna
16-Port Passive 800442008 - 270
Antenna

2.9.3 Vibration

The Hybrid AIR unit complies with the following vibration standard.

— ETSI EN 300 019-2-4 class T4.1, severity class 1

— Earthquake zone 4

— GR-63 Chapter 4.4

2.9.4 Materials
All Ericsson products fulfill the legal, market, and Ericsson requirements
regarding the following:

— Material declaration

— Materials' fire resistance, components, wires, and cables

— Recycling

— Restricted and banned material use

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 23


Hybrid AIR Description

2.10 Power Supply Characteristics


For details on the power supply requirements, power consumption, and fuse and
circuit breaker recommendations for the AIR units see Antenna Integrated Radio
Unit Description in the Hardware Antenna System, Battery, Enclosure, Power,
Radio, RAN Compute library.

2.11 System Characteristics


This section describes the system characteristics of the Hybrid AIR unit.

2.11.1 Software
For information on software dependencies, see Radio Software Support in the
Ericsson Radio System Hardware - Antenna System, Enclosure, Integrated Site
Solutions, Network Synchronization, Power, Radio, RAN Compute and RBS
library collection.

24 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Hardware Architecture

3 Hardware Architecture

This section describes the Hybrid AIR unit hardware structure regardless of
configuration.

3.1 Hybrid AIR Unit Parts

Ge22829A

Figure 9 Hybrid AIR Unit Parts

Table 17 Hybrid AIR Unit Parts


Position Component
A Radome
B Passive Antenna
C AIR Unit

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 25


Hybrid AIR Description

4 Connection Interfaces

For more information on the power supply, optical, sync, EV light, and TX monitor
interface, and optical indicators see Install Antenna Integrated Radio Units in the
Hardware Antenna System, Battery, Enclosure, Power, Radio, RAN Compute
library.

4.1 Grounding Interface


The AIR units and the spine must be grounded to protect it from overvoltage and
lightning strikes. The grounding interface on the AIR units and the spine accepts
a dual M6, C-C 15.88 mm lug on a coated cable.

26 298/1551-LZA 701 6001/1 Uen H | 2021-03-16


Standards and Regulations

5 Standards and Regulations

This section presents a brief overview of standards, regulatory product approval,


and declaration of conformity.

Declaration of Conformity
"Hereby, Ericsson AB, declares that this Product is in compliance with the
essential requirements and other relevant provisions of Directive 2014/53/EU
and 2011/65/EU."

5.1 Regulatory Approval


The product complies with the following regulatory requirements:

Table 18 Regulatory Approvals

Corrosion IEC/UL60950-22
ISO 21207 method B
UV Resistance IEC 60950-22
Impact Test IEC/UL60950-22
Flammability UL94-HB
Passive Inter Modulation IM3

5.1.1 Environmental Standards Compliance


The product complies with the following environmental standard:

Europe

— Restriction of Hazardous Substances in Electrical and Electronic Equipment


(RoHS) Directive (2011/65/EU)

5.1.2 Safety Standards Compliance


In accordance with market requirements, the product complies with the following
product safety standards and directives:

International

— IEC 62368-1

298/1551-LZA 701 6001/1 Uen H | 2021-03-16 27


Hybrid AIR Description

— UL 62368-1

5.2 Other Standards and Regulations


The standards and regulations in this section are not regulatory approved.

5.2.1 Spare Parts


The product adheres to the Ericsson Serviceability and Spare Part Strategy.

5.2.2 Surface Quality


The surface quality of the Hybrid AIR units is according to Ericsson standard
class A5.

28 298/1551-LZA 701 6001/1 Uen H | 2021-03-16

You might also like