‫ﺍﻟﺘﻌﻴﻴﻦ‪C94/C94M - 17a:‬‬

‫ﺍﻟﻤﻮﺍﺻﻔﺎﺕﺍﻟﻘﻴﺎﺳﻴﺔ ﻝ‬
‫ﺧﺮﺳﺎﻧﺔﺟﺎﻫﺰﺓ‪1‬‬

‫ﺗﻢﺇﺻﺪﺍﺭ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺗﺤﺖ ﺍﻟﺘﺴﻤﻴﺔ ﺍﻟﺜﺎﺑﺘﺔ ‪C94/C94M‬؛ ﻭﻳﺸﻴﺮ ﺍﻟﺮﻗﻢ ﺍﻟﺬﻱ ﻳﻠﻲ ﺍﻟﺘﻌﻴﻴﻦ ﻣﺒﺎﺷﺮﺓ ﺇﻟﻰ ﺳﻨﺔ ﺍﻻﻋﺘﻤﺎﺩ ﺍﻷﺻﻠﻲ‪ ،‬ﺃﻭ ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﻤﺮﺍﺟﻌﺔ‪ ،‬ﺳﻨﺔ‬
‫ﺍﻟﻤﺮﺍﺟﻌﺔﺍﻷﺧﻴﺮﺓ‪ .‬ﻳﺸﻴﺮ ﺍﻟﺮﻗﻢ ﺍﻟﻤﻮﺟﻮﺩ ﺑﻴﻦ ﻗﻮﺳﻴﻦ ﺇﻟﻰ ﺳﻨﺔ ﺇﻋﺎﺩﺓ ﺍﻟﻤﻮﺍﻓﻘﺔ ﺍﻷﺧﻴﺮﺓ‪ .‬ﻳﺸﻴﺮ ﺍﻟﺤﺮﻑ ﺍﻟﻤﺮﺗﻔﻊ ‪ (´) epsilon‬ﺇﻟﻰ ﺣﺪﻭﺙ ﺗﻐﻴﻴﺮ ﺗﺤﺮﻳﺮﻱ ﻣﻨﺬ ﺁﺧﺮ‬
‫ﻣﺮﺍﺟﻌﺔﺃﻭ ﺇﻋﺎﺩﺓ ﻣﻮﺍﻓﻘﺔ‪.‬‬

‫ﺗﻤﺖﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻰ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻣﻦ ﻗﺒﻞ ﻭﻛﺎﻻﺕ ﻭﺯﺍﺭﺓ ﺍﻟﺪﻓﺎﻉ ﺍﻷﻣﺮﻳﻜﻴﺔ‪.‬‬

‫‪1.6‬ﺗﻢ ﺗﻄﻮﻳﺮ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺍﻟﺪﻭﻟﻲ ﻭﻓﻘﺎً ﻟﻠﻤﺒﺎﺩﺉ ﺍﻟﻤﻌﺘﺮﻑ ﺑﻬﺎ ﺩﻭﻟﻴﺎً‬ ‫‪1‬ﻧﻄﺎﻕ*‬
‫ﺑﺸﺄﻥﺍﻟﺘﻘﻴﻴﺲ ﺍﻟﻤﻨﺼﻮﺹ ﻋﻠﻴﻬﺎ ﻓﻲ ﺍﻟﻘﺮﺍﺭ ﺍﻟﻤﺘﻌﻠﻖ ﺑﻤﺒﺎﺩﺉ ﺗﻄﻮﻳﺮ‬ ‫‪1.1‬ﺗﻐﻄﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ ﻓﻲ‬
‫ﺍﻟﻤﻌﺎﻳﻴﺮﻭﺍﻷﺩﻟﺔ ﻭﺍﻟﺘﻮﺻﻴﺎﺕ ﺍﻟﺪﻭﻟﻴﺔ ﺍﻟﺼﺎﺩﺭ ﻋﻦ ﻟﺠﻨﺔ ﺍﻟﻌﻮﺍﺉﻖ ﺍﻟﻔﻨﻴﺔ‬ ‫‪)3.2.2‬ﻣﻼﺣﻈﺔ ‪ .(1‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻣﺘﻄﻠﺒﺎﺕ ﺟﻮﺩﺓ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‬
‫ﻟﻠﺘﺠﺎﺭﺓ)‪ (TBT‬ﺍﻟﺘﺎﺑﻌﺔ ﻟﻤﻨﻈﻤﺔ ﺍﻟﺘﺠﺎﺭﺓ ﺍﻟﻌﺎﻟﻤﻴﺔ‪.‬‬ ‫ﺇﻣﺎﻛﻤﺎ ﻫﻮ ﻣﺬﻛﻮﺭ ﻓﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺃﻭ ﺣﺴﺐ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ‪.‬‬
‫ﻋﻨﺪﻣﺎﺗﺨﺘﻠﻒ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻛﻤﺎ ﻫﻮ ﻣﺬﻛﻮﺭ ﻓﻲ ﺍﻟﻄﻠﺐ‪ ،‬ﻋﻦ ﺗﻠﻚ‬
‫ﺍﻟﻮﺍﺭﺩﺓﻓﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ ،‬ﻓﺈﻥ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﺸﺘﺮﻱ ﻫﻲ ﺍﻟﺘﻲ ﺗﺴﺮﻱ‪.‬‬
‫ﻻﺗﻐﻄﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻭﺿﻊ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺃﻭ ﺗﺪﻋﻴﻤﻬﺎ ﺃﻭ ﻣﻌﺎﻟﺠﺘﻬﺎ ﺃﻭ‬
‫‪.2‬ﺍﻟﻮﺛﺎﺉﻖ ﺍﻟﻤﺮﺟﻌﻴﺔ‬
‫ﺣﻤﺎﻳﺘﻬﺎﺑﻌﺪ ﺗﺴﻠﻴﻤﻬﺎ ﺇﻟﻰ ﺍﻟﻤﺸﺘﺮﻱ‪.‬‬
‫‪2.1‬ﻣﻌﺎﻳﻴﺮ ‪:ASTM‬‬
‫‪3‬‬
‫‪C31/C31M‬ﻣﻤﺎﺭﺳﺔ ﻟﺼﻨﻊ ﻭﻣﻌﺎﻟﺠﺔ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺍﻟﻌﻴﻨﺎﺕﻓﻲ ﺍﻟﻤﻴﺪﺍﻥ‬
‫‪C33/C33M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺮﺳﺎﻧﻲ ‪C39/C39M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‬ ‫ﻥ‪ -1OTE‬ﻳﺘﻢ ﺗﻐﻄﻴﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻨﺘﺠﺔ ﻋﻦ ﻃﺮﻳﻖ ﺍﻟﺨﻠﻂ ﺍﻟﺤﺠﻤﻲ ﻭﺍﻟﺨﻠﻂ ﺍﻟﻤﺴﺘﻤﺮ‬
‫ﻓﻲﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ .C685‬ﻳﺘﻢ ﺗﻐﻄﻴﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺴﻠﺤﺔ ﺑﺎﻷﻟﻴﺎﻑ ﻓﻲ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‬
‫ﻗﻮﺓﺍﻟﻀﻐﻂ ﻟﻸﺳﻄﻮﺍﻧﺔ‪-‬‬ ‫‪.C1116‬‬
‫ﻋﻴﻨﺎﺕﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻓﺔ‬
‫‪1.2‬ﺍﻟﻘﻴﻢ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺇﻣﺎ ﺑﻮﺣﺪﺍﺕ ﺍﻟﻨﻈﺎﻡ ﺍﻟﺪﻭﻟﻲ )‪ ،(SI‬ﺍﻟﻤﺒﻴﻨﺔ ﺑﻴﻦ‬
‫‪C125‬ﺍﻟﻤﺼﻄﻠﺤﺎﺕ ﺍﻟﻤﺘﻌﻠﻘﺔ ﺑﺎﻟﺨﺮﺳﺎﻧﺔ ﻭﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﻗﻮﺳﻴﻦ‪،‬ﺃﻭ ﺑﻮﺣﺪﺍﺕ ﺍﻟﺒﻮﺻﺔ‪/‬ﺍﻟﺮﻃﻞ ﻳﺠﺐ ﺍﻋﺘﺒﺎﺭﻫﺎ ﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ‬
‫ﻏﺮﻳﺘﺲ‬
‫ﻛﻤﻌﻴﺎﺭﻗﻴﺎﺳﻲ‪ .‬ﻗﺪ ﻻ ﺗﻜﻮﻥ ﺍﻟﻘﻴﻢ ﺍﻟﻤﺬﻛﻮﺭﺓ ﻓﻲ ﻛﻞ ﻧﻈﺎﻡ ﻣﻜﺎﻓﺉﺔ ﺗﻤﺎﻣﺎً؛‬
‫‪C138/C138M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻜﺜﺎﻓﺔ )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻭﺍﻹﻧﺘﺎﺟﻴﺔ‬
‫ﻭﻟﺬﻟﻚﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻡ ﻛﻞ ﻧﻈﺎﻡ ﺑﺸﻜﻞ ﻣﺴﺘﻘﻞ ﻋﻦ ﺍﻵﺧﺮ‪ .‬ﻗﺪ ﻳﺆﺩﻱ‬
‫ﻭﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء )ﺍﻟﺜﻘﻠﻴﺔ( ﻟﻠﺨﺮﺳﺎﻧﺔ ‪C143/C143M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‬
‫ﺍﻟﺠﻤﻊﺑﻴﻦ ﺍﻟﻘﻴﻢ ﻣﻦ ﺍﻟﻨﻈﺎﻣﻴﻦ ﺇﻟﻰ ﻋﺪﻡ ﺍﻟﺘﻮﺍﻓﻖ ﻣﻊ ﺍﻟﻤﻌﻴﺎﺭ‪.‬‬
‫ﻫﺒﻮﻁﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ‬
‫ﺃﺳﻤﻨﺖ‬
‫‪C150/C150M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻻﺳﻤﻨﺖ ﺍﻟﺒﻮﺭﺗﻼﻧﺪﻱ ‪C172/C172M‬‬ ‫‪1.3‬ﻛﻤﺎ ﻫﻮ ﻣﺴﺘﺨﺪﻡ ﻓﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ ،‬ﺗﻨﺘﺞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‬
‫ﻣﻤﺎﺭﺳﺔﺃﺧﺬ ﻋﻴﻨﺎﺕ ﻣﻦ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﻄﺎﺯﺟﺔ‬ ‫ﺧﺮﺳﺎﻧﺔﺟﺎﻫﺰﺓ ﺍﻟﺨﻠﻂ‪ .‬ﻳﻘﻮﻡ ﺍﻟﻤﺸﺘﺮﻱ ﺑﺸﺮﺍء ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‪.‬‬
‫ﻛﺮﻳﺖ‬
‫‪C173/C173M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻠﺨﻠﻄﺔ ﺍﻟﻄﺎﺯﺟﺔ‬ ‫‪1.4‬ﻳﺸﻴﺮ ﻧﺺ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺇﻟﻰ ﺍﻟﻤﻼﺣﻈﺎﺕ ﻭﺍﻟﺤﻮﺍﺷﻲ ﺍﻟﺘﻲ ﺗﻮﻓﺮ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺑﺎﻟﻄﺮﻳﻘﺔ ﺍﻟﺤﺠﻤﻴﺔ‬ ‫ﻣﺎﺩﺓﺗﻮﺿﻴﺤﻴﺔ‪ .‬ﻭﻻ ﺗﻌﺘﺒﺮ ﻫﺬﻩ ﺍﻟﻤﻼﺣﻈﺎﺕ ﻭﺍﻟﺤﻮﺍﺷﻲ )ﺑﺎﺳﺘﺜﻨﺎء ﺗﻠﻚ‬
‫‪C231/C231M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻠﺨﻠﻄﺔ ﺍﻟﻄﺎﺯﺟﺔ‬ ‫ﺍﻟﻮﺍﺭﺩﺓﻓﻲ ﺍﻟﺠﺪﺍﻭﻝ ﻭﺍﻷﺷﻜﺎﻝ( ﻣﻦ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻌﻴﺎﺭ‪.‬‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺑﻄﺮﻳﻘﺔ ﺍﻟﻀﻐﻂ‬
‫‪C260/C260M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﺘﻲ ﺗﺤﺒﺲ ﺍﻟﻬﻮﺍء‬
‫‪1.5‬ﻻ ﻳﻬﺪﻑ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺇﻟﻰ ﻣﻌﺎﻟﺠﺔ ﻛﺎﻓﺔ ﺍﻟﻤﺨﺎﻭﻑ ﺍﻟﻤﺘﻌﻠﻘﺔ‬
‫ﻟﻠﺨﺮﺳﺎﻧﺔ‬
‫ﺑﺎﻟﺴﻼﻣﺔ‪،‬ﺇﻥ ﻭﺟﺪﺕ‪ ،‬ﻭﺍﻟﻤﺮﺗﺒﻄﺔ ﺑﺎﺳﺘﺨﺪﺍﻣﻪ‪ .‬ﺗﻘﻊ ﻋﻠﻰ ﻋﺎﺗﻖ ﻣﺴﺘﺨﺪﻡ‬
‫‪C330/C330M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺮﻛﺎﻡ ﺧﻔﻴﻒ ﺍﻟﻮﺯﻥ‬
‫ﻫﺬﺍﺍﻟﻤﻌﻴﺎﺭ ﻣﺴﺆﻭﻟﻴﺔ ﺇﻧﺸﺎء ﻣﻤﺎﺭﺳﺎﺕ ﺍﻟﺴﻼﻣﺔ ﻭﺍﻟﺼﺤﺔ ﺍﻟﻤﻨﺎﺳﺒﺔ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻬﻴﻜﻠﻴﺔ‬
‫ﻭﺗﺤﺪﻳﺪﺇﻣﻜﺎﻧﻴﺔ ﺗﻄﺒﻴﻖ ﺍﻟﻘﻴﻮﺩ ﺍﻟﺘﻨﻈﻴﻤﻴﺔ ﻗﺒﻞ ﺍﻻﺳﺘﺨﺪﺍﻡ‪).‬ﺗﺤﺬﻳﺮ‪-‬ﺗﻌﺘﺒﺮ‬
‫‪C494/C494M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ‬
‫ﺍﻟﺨﻠﻄﺎﺕﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻴﺔ ﺍﻟﻄﺎﺯﺟﺔ ﻣﺎﺩﺓ ﻛﺎﻭﻳﺔ ﻭﻗﺪ ﺗﺴﺒﺐ‬
‫ﺃﺳﻤﻨﺖ‬
‫ﺣﺮﻭﻗﺎًﻛﻴﻤﻴﺎﺉﻴﺔ ﻟﻠﺠﻠﺪ ﻭﺍﻷﻧﺴﺠﺔ ﻋﻨﺪ ﺍﻻﺳﺘﺨﺪﺍﻡ ﻟﻔﺘﺮﺓ ﻃﻮﻳﻠﺔ‪(2.‬‬
‫‪C567/C567M‬ﻃﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ﻟﺘﺤﺪﻳﺪ ﻛﺜﺎﻓﺔ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ ﺍﻟﻬﻴﻜﻠﻴﺔ‬
‫‪C595/C595M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ ﺍﻟﻤﺨﻠﻮﻁ ‪C618‬‬
‫ﻣﻮﺍﺻﻔﺎﺕﺭﻣﺎﺩ ﺍﻟﻔﺤﻢ ﺍﻟﻤﺘﻄﺎﻳﺮ ﻭﺍﻟﺨﺎﻡ ﺃﻭ ﺍﻟﻤﻜﻠﺲ‬
‫‪1‬ﺗﺨﻀﻊ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻟﺴﻠﻄﺔ ﻟﺠﻨﺔ ‪C09ASTM‬ﻋﻠﻰ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺮﺳﺎﻧﻲ ﻭﻫﻲ‬
‫ﺍﻟﺒﻮﺯﻭﻻﻥﺍﻟﻄﺒﻴﻌﻲ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻓﻲ ﺍﻟﺨﺮﺳﺎﻧﺔ‬ ‫ﺍﻟﻤﺴﺆﻭﻟﻴﺔﺍﻟﻤﺒﺎﺷﺮﺓ ﻟﻠﺠﻨﺔ ﺍﻟﻔﺮﻋﻴﺔ ‪C09.40‬ﻋﻠﻰ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‪.‬‬

‫ﺗﻤﺖﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻰ ﺍﻹﺻﺪﺍﺭ ﺍﻟﺤﺎﻟﻲ ﻓﻲ ‪ 1‬ﺃﻏﺴﻄﺲ ‪ .2017‬ﺗﻢ ﻧﺸﺮﻩ ﻓﻲ ﺃﻏﺴﻄﺲ ‪ .2017‬ﺗﻤﺖ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻴﻪ ﻓﻲ‬
‫‪3‬ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﻣﻌﺎﻳﻴﺮ ‪ ASTM‬ﺍﻟﻤﺮﺟﻌﻴﺔ‪ ،‬ﻗﻢ ﺑﺰﻳﺎﺭﺓ ﻣﻮﻗﻊ ‪ ASTM‬ﺍﻹﻟﻜﺘﺮﻭﻧﻲ‪،‬‬ ‫ﺍﻷﺻﻞﻋﺎﻡ ‪ .1933‬ﺗﻤﺖ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻰ ﺍﻹﺻﺪﺍﺭ ﺍﻟﺴﺎﺑﻖ ﺍﻷﺧﻴﺮ ﻓﻲ ﻋﺎﻡ ‪ 2017‬ﺑﺎﺳﻢ ‪/C0094_C0094M-17A‬‬
‫‪ ،www.astm.org‬ﺃﻭ ﺍﺗﺼﻞ ﺑﺨﺪﻣﺔ ﻋﻤﻼء ‪ ASTM‬ﻋﻠﻰ ‪ . service@astm.org‬ﻝﺍﻟﻜﺘﺎﺏ‬ ‫‪.C94/C94M – 17. DOI: 10.1520‬‬
‫ﺍﻟﺴﻨﻮﻱﻟﻤﻌﺎﻳﻴﺮ ‪ASTM‬ﻣﻌﻠﻮﻣﺎﺕ ﺍﻟﺤﺠﻢ‪ ،‬ﺭﺍﺟﻊ ﺻﻔﺤﺔ ﻣﻠﺨﺺ ﺍﻟﻤﺴﺘﻨﺪﺍﺕ ﺍﻟﺨﺎﺻﺔ ﺑﺎﻟﻤﻌﻴﺎﺭ ﻋﻠﻰ‬ ‫‪2‬ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ ﺍﻟﺨﺎﺹ ﺑﺎﺣﺘﻴﺎﻃﺎﺕ ﺍﻟﺴﻼﻣﺔ‪ ،‬ﺩﻟﻴﻞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺮﻛﺎﻡ ﻭﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﺍﻟﻜﺘﺎﺏ ﺍﻟﺴﻨﻮﻱ‬
‫ﻣﻮﻗﻊ‪ ASTM‬ﺍﻹﻟﻜﺘﺮﻭﻧﻲ‪.‬‬ ‫ﻟﻤﻌﺎﻳﻴﺮ‪ ،ASTM‬ﺍﻟﻤﺠﻠﺪ ‪.04.02‬‬

‫* ﻳﻈﻬﺮ ﻗﺴﻢ ﻣﻠﺨﺺ ﺍﻟﺘﻐﻴﻴﺮﺍﺕ ﻓﻲ ﻧﻬﺎﻳﺔ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ‬


‫ﺣﻘﻮﻕﺍﻟﻄﺒﻊ ﻭﺍﻟﻨﺸﺮ © ‪ .ASTM International، 100 Barr Harbour Drive، PO Box C700، West Conshohocken، PA 19428-2959‬ﺍﻟﻮﻻﻳﺎﺕ ﺍﻟﻤﺘﺤﺪﺓ‬

‫‪1‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫‪3.2.4‬ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﻣﺨﺘﻠﻄﺔ ﺑﺎﻟﺸﺎﺣﻨﺎﺕ‪ ،‬ﻥ ‪-‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‬ ‫‪C637‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺮﻛﺎﻡ ﻟﻠﻮﻗﺎﻳﺔ ﻣﻦ ﺍﻹﺷﻌﺎﻉ‬
‫ﺑﺎﻟﻜﺎﻣﻞﻓﻲ ﺧﻼﻃﺔ ﺍﻟﺸﺎﺣﻨﺔ‪.‬‬ ‫ﺃﺳﻤﻨﺖ‬
‫‪3.2.5‬ﺍﻟﻤﺎء‪ ،‬ﺍﻟﺪﻓﻌﺔ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ‪ ،‬ﻥ‪-‬ﻛﻤﻴﺔ ﺍﻟﻤﺎء ﺍﻟﻤﺮﺍﺩ ﺇﺿﺎﻓﺘﻬﺎ ﺇﻟﻰ‬ ‫‪C685‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺑﺎﻟﺨﻠﻄﺔ ﺍﻟﺤﺠﻤﻴﺔ‪-‬‬
‫ﺍﻟﺪﻓﻌﺔﻣﻦ ﺧﻼﻝ ﻧﻈﺎﻡ ﻗﻴﺎﺱ ﺍﻟﻤﺎء ﺑﻌﺪ ﺗﻌﻮﻳﺾ ﻛﻤﻴﺔ ﺍﻟﺜﻠﺞ‪ ،‬ﺇﺫﺍ ﺗﻢ‬ ‫ﺍﻟﺨﻠﻂﻭﺍﻟﺨﻠﻂ ﺍﻟﻤﺴﺘﻤﺮ‬
‫ﺍﺳﺘﺨﺪﺍﻣﻪ‪،‬ﻭﺍﻟﺮﻃﻮﺑﺔ ﺍﻟﺴﻄﺤﻴﺔ ﻋﻠﻰ ﺍﻟﺮﻛﺎﻡ ﻭﺍﻟﻤﺎء ﻓﻲ ﺍﻟﺨﻠﻄﺎﺕ‪ ،‬ﻋﻨﺪ‬ ‫‪C989/C989M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻷﺳﻤﻨﺖ ﺍﻟﺨﺒﺚ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻓﻲ‬
‫ﺍﻻﻗﺘﻀﺎء‪،‬ﻭﺑﻄﺮﺡ ﻛﻤﻴﺔ ﻣﻦ ﺍﻟﻤﺎء ﺍﻟﻤﺘﻮﻗﻊ ﺃﻥ ﺗﻀﺎﻑ ﺇﻟﻰ ﺍﻟﺪﻓﻌﺔ ﻳﻤﻜﻦ‬ ‫ﺍﻟﺨﺮﺳﺎﻧﺔﻭﻗﺬﺍﺉﻒ ﺍﻟﻬﺎﻭﻥ‬
‫ﺇﺿﺎﻓﺘﻬﺎﻓﻲ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ ﺃﻭ ﺃﺛﻨﺎء ﺍﻟﻨﻘﻞ ﻟﻀﺒﻂ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ‬ ‫‪C1017/C1017M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ‬
‫ﻓﻲﺩﻓﻌﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬ ‫ﺍﺳﺘﺨﺪﺍﻣﻬﺎﻓﻲ ﺇﻧﺘﺎﺝ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺘﺪﻓﻘﺔ ‪C1064/C1064M‬‬
‫ﻃﺮﻳﻘﺔﺍﺧﺘﺒﺎﺭ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﻄﺎﺯﺝ‬
‫ﺧﺮﺳﺎﻧﺔﺃﺳﻤﻨﺘﻴﺔ ﻫﻴﺪﺭﻭﻟﻴﻜﻴﺔ ﻣﺨﺘﻠﻄﺔ‬
‫‪.4‬ﺃﺳﺎﺱ ﺍﻟﺸﺮﺍء‬ ‫‪C1077‬ﻣﻤﺎﺭﺳﺔ ﻟﻠﻮﻛﺎﻻﺕ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺍﻟﻤﺠﺎﻣﻴﻊﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ ﺍﻟﺒﻨﺎء ﻭﻣﻌﺎﻳﻴﺮ ﺗﻘﻴﻴﻢ ﻭﻛﺎﻟﺔ ﺍﻻﺧﺘﺒﺎﺭ‬
‫‪4.1‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺃﺳﺎﺱ ﺍﻟﺸﺮﺍء ﻫﻮ ﻳﺎﺭﺩﺓ ﻣﻜﻌﺒﺔ ﺃﻭ ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻦ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻄﺎﺯﺟﺔ ﺍﻟﺘﻲ ﺗﻢ ﺗﻔﺮﻳﻐﻬﺎ ﻣﻦ ﻭﺣﺪﺓ ﺍﻟﻨﻘﻞ‪.‬‬ ‫‪C1116‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺴﻠﺤﺔ ﺑﺎﻷﻟﻴﺎﻑ ﻭ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻤﺮﺷﻮﺷﺔ‬

‫‪4.2‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﻓﻲ ﺩﻓﻌﺔ ﻣﻌﻴﻨﺔ ﻣﻦ ﺍﻟﻜﺘﻠﺔ‬ ‫‪C1157/C1157M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻷﺩﺍء ﻟﻠﻬﻴﺪﺭﻭﻟﻴﻜﻲ‬
‫ﺍﻹﺟﻤﺎﻟﻴﺔﻟﻠﺨﻠﻄﺔ ﻣﻘﺴﻮﻣﺔ ﻋﻠﻰ ﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ .‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﺍﻟﻜﺘﻠﺔ‬ ‫ﻳﺒﻨﻲ‬
‫ﺍﻹﺟﻤﺎﻟﻴﺔﻟﻠﺪﻓﻌﺔ ﻋﻠﻰ ﺃﻧﻬﺎ ﺍﻟﻜﺘﻠﺔ ﺍﻟﺼﺎﻓﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺍﻟﺪﻓﻌﺔ ﻛﻤﺎ ﺗﻢ‬ ‫‪C1240‬ﻣﻮﺍﺻﻔﺎﺕ ﺃﺑﺨﺮﺓ ﺍﻟﺴﻴﻠﻴﻜﺎ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ ﺍﻷﺳﻤﻨﺖ‬
‫ﺗﺴﻠﻴﻤﻬﺎ‪،‬ﺑﻤﺎ ﻓﻲ ﺫﻟﻚ ﺇﺟﻤﺎﻟﻲ ﻣﻴﺎﻩ ﺍﻟﺨﻠﻂ ﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ ﻓﻲ‪ .9.3‬ﻳﺘﻢ‬ ‫ﻣﺨﺎﻟﻴﻂ‬
‫ﺗﺤﺪﻳﺪﺍﻟﻜﺜﺎﻓﺔ ﻭﻓﻘﺎً ﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ‪ .C138/C138M‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﺍﻟﻌﺎﺉﺪ‬ ‫‪C1602/C1602M‬ﻣﻮﺍﺻﻔﺎﺕ ﺧﻠﻂ ﺍﻟﻤﻴﺎﻩ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ‬
‫ﻋﻠﻰﺃﻧﻪ ﻣﺘﻮﺳﻂ ﺛﻼﺛﺔ ﻗﻴﺎﺳﺎﺕ ﻋﻠﻰ ﺍﻷﻗﻞ‪ ،‬ﻭﺍﺣﺪ ﻣﻦ ﻛﻞ ﻭﺣﺪﺓ ﻣﻦ‬ ‫ﺇﻧﺘﺎﺝﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻴﺔ ‪C1611/C1611M‬ﻃﺮﻳﻘﺔ‬
‫ﻭﺣﺪﺍﺕﺍﻟﻨﻘﻞ ﺍﻟﺜﻼﺙ ﺍﻟﻤﺨﺘﻠﻔﺔ ﺍﻟﺘﻲ ﺗﻢ ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﻣﻨﻬﺎ ﻭﻓﻘﺎً ﻟﻠﻤﻤﺎﺭﺳﺔ‬ ‫ﺍﺧﺘﺒﺎﺭﻫﺒﻮﻁ ﺍﻟﺘﺪﻓﻖ ﺍﻟﺬﺍﺗﻲ‬
‫‪.C172/C172M‬‬ ‫ﺗﻮﺣﻴﺪﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫‪C1798/C1798M‬ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﺍﻟﻤﺮﺗﺠﻌﺔ‬
‫ﻟﻼﺳﺘﺨﺪﺍﻡﻓﻲ ﺩﻓﻌﺔ ﺟﺪﻳﺪﺓ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‬
‫‪2.2‬ﻭﺛﺎﺉﻖ ﺍﻟﻤﺠﻠﺲ ﺍﻟﺪﻭﻟﻲ ﻟﻠﻤﻄﺎﺭﺍﺕ‪:‬‬
‫ﻥ‪-2OTE‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻣﻔﻬﻮﻣﺎ ﺃﻥ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺘﺼﻠﺪﺓ ﻗﺪ ﻳﻜﻮﻥ‪ ،‬ﺃﻭ ﻳﺒﺪﻭ ﺃﻧﻪ‪،‬‬
‫‪4‬‬

‫ﺃﻗﻞﻣﻦ ﺍﻟﻤﺘﻮﻗﻊ ﺑﺴﺒﺐ ﺍﻟﻬﺪﺭ ﻭﺍﻻﻧﺴﻜﺎﺑﺎﺕ‪ ،‬ﺃﻭ ﺍﻹﻓﺮﺍﻁ ﻓﻲ ﺍﻟﺤﻔﺮ‪ ،‬ﺃﻭ ﺍﻧﺘﺸﺎﺭ ﺍﻷﺷﻜﺎﻝ‪،‬‬ ‫ﺇﻳﻪﺳﻲ ﺁﻱ ‪211.1‬ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻻﺧﺘﻴﺎﺭ ﺍﻟﻨﺴﺐ ﻝ‬
‫ﺃﻭﻓﻘﺪﺍﻥ ﺑﻌﺾ ﺍﻟﻬﻮﺍء ﺍﻟﻤﺤﺒﻮﺱ‪ ،‬ﺃﻭ ﺗﺴﻮﻳﺔ ﺍﻟﺨﻼﺉﻂ ﺍﻟﺮﻃﺒﺔ‪ ،‬ﻻ ﺷﻲء ﻣﻦ ﻫﺬﺍ‪ .‬ﻭﺍﻟﺘﻲ‬ ‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻌﺎﺩﻳﺔ ﻭﺍﻟﺜﻘﻴﻠﺔ ﻭﺍﻟﻜﺘﻠﺔ‬
‫ﻫﻲﻣﺴﺆﻭﻟﻴﺔ ﺍﻟﻤﻨﺘﺞ‪.‬‬ ‫ﺁﻱﺳﻲ ﺁﻱ ‪211.2‬ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻻﺧﺘﻴﺎﺭ ﺍﻟﻨﺴﺐ ﻝ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ ﺍﻟﻬﻴﻜﻠﻴﺔ‬
‫‪.5‬ﺍﻟﻤﻮﺍﺩ‬ ‫ﺍﻳﻪﺳﻲ ﺁﻱ ‪301‬ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻹﻧﺸﺎﺉﻴﺔ ﺇﻳﻪ‬
‫‪5.1‬ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﻣﻮﺍﺻﻔﺎﺕ ﻣﺤﺪﺩﺓ ﻟﻠﻤﻮﺍﺩ ﻗﺎﺑﻠﺔ ﻟﻠﺘﻄﺒﻴﻖ‪،‬‬ ‫ﺳﻲﺁﻱ ‪ 305‬ﺁﺭﺩﻟﻴﻞ ﻟﻠﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺍﻟﻄﻘﺲ ﺍﻟﺤﺎﺭ ﺇﻳﻪ ﺳﻲ ﺁﻱ ‪306‬‬
‫ﻳﺠﺐﺍﺳﺘﺨﺪﺍﻡ ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬ ‫ﺁﺭﺩﻟﻴﻞ ﻟﻠﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺍﻟﻄﻘﺲ ﺍﻟﺒﺎﺭﺩ‬
‫ﺍﻳﻪﺳﻲ ﺁﻱ ‪318‬ﻣﺘﻄﻠﺒﺎﺕ ﻛﻮﺩ ﺍﻟﺒﻨﺎء ﻟﻺﻧﺸﺎءﺍﺕ ﺍﻹﻧﺸﺎﺉﻴﺔ‬
‫ﻛﺮﻳﺖﻭﺍﻟﺘﻌﻠﻴﻖ‬
‫‪5.2‬ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ‪:‬‬
‫‪2.3‬ﻭﺛﺎﺉﻖ ﺃﺧﺮﻯ‪5:‬‬
‫‪5.2.1‬ﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ—ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ‬
‫ﻧﻴﺴﺖ‪1-105‬ﺍﻟﻤﻌﻬﺪ ﺍﻟﻮﻃﻨﻲ ﻟﻠﻤﻌﺎﻳﻴﺮ ﻭﺍﻟﺘﻜﻨﻮﻟﻮﺟﻴﺎ‬
‫ﻣﻄﺎﺑﻘﺎ ًﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ ،C150/C150M‬ﺗﺨﺼﻴﺺ‪ ،C595/C595M‬ﺃﻭ‬
‫ﻛﺘﻴﺐ‬
‫ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.C1157/C1157M‬‬
‫‪5.2.2‬ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﺘﻜﻤﻴﻠﻴﺔ —ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺭﻣﺎﺩ ﺍﻟﻔﺤﻢ‬ ‫‪.3‬ﺍﻟﻤﺼﻄﻠﺤﺎﺕ‬
‫ﺍﻟﻤﺘﻄﺎﻳﺮﺃﻭ ﺍﻟﺒﻮﺯﻭﻻﻥ ﺍﻟﻄﺒﻴﻌﻲ ﻣﻄﺎﺑﻘﺎ ًﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ .C618‬ﻳﺠﺐ ﺃﻥ‬
‫ﻳﻜﻮﻥﺍﻷﺳﻤﻨﺖ ﺍﻟﺨﺒﺚ ﻣﻄﺎﺑﻘﺎ ًﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ .C989/C989M‬ﻳﺠﺐ ﺃﻥ‬ ‫‪3.1‬ﺗﻌﺮﻳﻔﺎﺕ‪-‬ﻳﺘﻢ ﺗﻌﺮﻳﻒ ﺍﻟﻤﺼﻄﻠﺤﺎﺕ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ ﻫﺬﻩ‬
‫ﻳﻜﻮﻥﺩﺧﺎﻥ ﺍﻟﺴﻴﻠﻴﻜﺎ ﻣﻄﺎﺑﻘﺎً ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪.C1240‬‬ ‫ﺍﻟﻤﻮﺍﺻﻔﺎﺕﻓﻲ ﺍﻟﻤﺼﻄﻠﺤﺎﺕ‪.C125‬‬

‫‪5.3‬ﺗﺠﻤﻌﺎﺕ‪-‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻣﺠﺎﻣﻴﻊ ﺍﻟﻮﺯﻥ ﺍﻟﻄﺒﻴﻌﻲ ﻣﻄﺎﺑﻘﺔ‬ ‫‪3.2‬ﺗﻌﺮﻳﻔﺎﺕ ﺍﻟﻤﺼﻄﻠﺤﺎﺕ ﺍﻟﺨﺎﺻﺔ ﺑﻬﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ‪:‬‬
‫ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ .C33/C33M‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺮﻛﺎﻡ ﺧﻔﻴﻒ ﺍﻟﻮﺯﻥ ﻣﻄﺎﺑﻘﺎ ً‬ ‫‪3.2.1‬ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﻣﺨﺘﻠﻄﺔ ﻣﺮﻛﺰﻳﺎ‪ ،‬ﻥ ‪-‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‬
‫ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪C330/C330M‬ﻭﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺜﻘﻴﻞ ﻣﻄﺎﺑﻘﺎ ً‬ ‫ﺑﺎﻟﻜﺎﻣﻞﻓﻲ ﺧﻼﻃﺔ ﺛﺎﺑﺘﺔ‪.‬‬
‫ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪.C637‬‬ ‫‪3.2.2‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ‪ ،‬ﻥ‪-‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻭﺗﺴﻠﻴﻤﻬﺎ ﻟﻠﻤﺸﺘﺮﻱ‬
‫ﻓﻲﺣﺎﻟﺔ ﺟﺪﻳﺪﺓ‪.‬‬
‫‪5.4‬ﻣﺎء‪-‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﻤﻴﺎﻩ ﻣﻄﺎﺑﻘﺔ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪/ C1602M‬‬
‫‪.C1602‬‬ ‫‪3.2.3‬ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﺍﻟﻤﺨﻠﻮﻃﺔ‪ ،‬ﻥ ‪-‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﺟﺰﺉﻴﺎ ً‬
‫ﻓﻲﺧﻼﻃﺔ ﺛﺎﺑﺘﺔ ﻣﻊ ﺍﺳﺘﻜﻤﺎﻝ ﺍﻟﺨﻠﻂ ﻓﻲ ﺧﻼﻃﺔ ﺍﻟﺸﺎﺣﻨﺔ‪.‬‬
‫‪5.5‬ﺍﻟﻤﻮﺍﺩ ﺍﻟﻤﻀﺎﻓﺔ ﻟﻠﻬﻮﺍء —ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻣﻀﺎﻓﺎﺕ ﺳﺤﺐ ﺍﻟﻬﻮﺍء‬
‫ﻣﻄﺎﺑﻘﺔﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪)C260/C260M‬ﻣﻼﺣﻈﺔ ‪.(3‬‬
‫‪5.6‬ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ‪-‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ‬
‫ﻣﻄﺎﺑﻘﺔﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪C494/C494M‬ﺃﻭ‪C1017/C1017M‬ﺣﺴﺐ‬ ‫‪4‬ﻣﺘﺎﺡ ﻣﻦ ‪9094، Farmington Hills، MI 48333-9094، http://www.concrete.org‬‬
‫‪.American Concrete Institute )ACI(، PO Box‬‬
‫ﺍﻻﻗﺘﻀﺎء)ﻣﻼﺣﻈﺔ ‪.(3‬‬ ‫‪5‬ﺩﻟﻴﻞ ‪) NIST 105-1‬ﺗﻤﺖ ﻣﺮﺍﺟﻌﺘﻪ ﻋﺎﻡ ‪" ،(1990‬ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻭﺍﻟﺘﺴﺎﻣﺤﺎﺕ ﻟﻠﻤﻌﺎﻳﻴﺮ‬
‫ﻥ‪ -3OTE‬ﻓﻲ ﺃﻱ ﺣﺎﻟﺔ ﻣﻌﻴﻨﺔ‪ ،‬ﻗﺪ ﺗﺨﺘﻠﻒ ﺍﻟﺠﺮﻋﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻣﻦ ﻣﻀﺎﻓﺎﺕ ﺍﺣﺘﺠﺎﺯ‬ ‫ﺍﻟﻤﺮﺟﻌﻴﺔﻭﺍﻷﻭﺯﺍﻥ ﻭﺍﻟﻤﻘﺎﻳﻴﺲ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ‪ .1-‬ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻭﺍﻟﺘﻔﺎﻭﺗﺎﺕ ﻟﻸﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ‬
‫ﺍﻟﻬﻮﺍء‪،‬ﻭﺍﻟﺘﺴﺮﻳﻊ‪ ،‬ﻭﺍﻟﺘﺜﺒﻴﻂ‪ .‬ﻭﻟﺬﻟﻚ‪ ،‬ﻳﻨﺒﻐﻲ ﺍﻟﺴﻤﺎﺡ ﺑﻤﺠﻤﻮﻋﺔ ﻣﻦ ﺍﻟﺠﺮﻋﺎﺕ‪ ،‬ﻭﺍﻟﺘﻲ‬ ‫ﺍﻟﻤﻴﺪﺍﻧﻴﺔ)‪ ،"(NIST Class F‬ﺍﻟﻤﻌﻬﺪ ﺍﻟﻮﻃﻨﻲ ﻟﻠﻤﻌﺎﻳﻴﺮ ﻭﺍﻟﺘﻜﻨﻮﻟﻮﺟﻴﺎ‪ ،.‬ﻭﺯﺍﺭﺓ ﺍﻟﺘﺠﺎﺭﺓ ﺍﻷﻣﺮﻳﻜﻴﺔ‪pdf ،‬‬
‫ﺳﻮﻑﺗﺴﻤﺢ ﺑﺎﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﺘﺄﺛﻴﺮ ﺍﻟﻤﻄﻠﻮﺏ‪.‬‬ ‫‪.http://www.nist.gov/pml/wmd/upload/105-1.‬‬
‫ﻥ‪ -4OTE‬ﺗﺒﺎﺩﻝ ﺍﻷﻧﻮﺍﻉ ﺃﻭ ﺍﻟﺨﺼﺎﺉﺺ ﺃﻭ ﺍﻷﻧﻮﺍﻉ ﺃﻭ ﺍﻷﺻﻨﺎﻑ ﺃﻭ ﺍﻟﺪﺭﺟﺎﺕ‬

‫‪2‬‬
‫ﺃ‪C94/C94M - 17‬‬
‫ﻥ‪ -7OTE‬ﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﻫﻲ ﺍﻟﻜﺜﺎﻓﺔ ﺍﻟﻮﺣﻴﺪﺓ ﺍﻟﻘﺎﺑﻠﺔ ﻟﻠﻘﻴﺎﺱ ﻟﻠﺨﺮﺳﺎﻧﺔ‬ ‫ﻣﻦﺍﻟﻤﻮﺍﺩ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻬﺎ ﻓﻲ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻗﺪ ﺗﻨﺘﺞ ﺧﺮﺳﺎﻧﺔ ﺫﺍﺕ ﺧﺼﺎﺉﺺ‬
‫ﺧﻔﻴﻔﺔﺍﻟﻮﺯﻥ ﻭﻗﺖ ﺍﻟﺘﺴﻠﻴﻢ‪ .‬ﺗﻜﻮﻥ ﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﺩﺍﺉﻤﺎً ﺃﻋﻠﻰ ﻣﻦ ﺍﻟﻜﺜﺎﻓﺔ‬ ‫ﻣﺨﺘﻠﻔﺔ‪.‬‬
‫ﺍﻟﻤﺘﻮﺍﺯﻧﺔﺃﻭ ﺍﻟﺠﺎﻓﺔ ﺑﺎﻟﻔﺮﻥ‪ .‬ﻭﻟﺬﻟﻚ‪ ،‬ﻟﻘﺒﻮﻝ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ ﻋﻠﻰ ﺃﺳﺎﺱ ﺍﻟﻜﺜﺎﻓﺔ‬
‫ﻓﻲﻭﻗﺖ ﺍﻟﺘﺴﻠﻴﻢ‪ ،‬ﻳﺠﺐ ﺇﻧﺸﺎء ﻋﻼﻗﺔ ﺑﻴﻦ ﻛﺜﺎﻓﺔ ﺍﻟﺘﻮﺍﺯﻥ ﻭﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‪.‬‬
‫‪5.7‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﺍﻟﻤﻌﺎﺩﺓ —ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‬
‫ﻳﺘﻢﺗﻐﻄﻴﺔ ﺍﻟﺘﻌﺎﺭﻳﻒ ﻭﻃﺮﻕ ﺗﺤﺪﻳﺪ ﺃﻭ ﺣﺴﺎﺏ ﺍﻟﺘﻮﺍﺯﻥ ﻭﺍﻟﻜﺜﺎﻓﺔ ﺍﻟﺠﺎﻓﺔ ﺑﺎﻟﻔﺮﻥ ﻣﻦ‬ ‫ﺍﻟﻤﻌﺎﺩﺓ‪،‬ﻋﻨﺪﻣﺎ ﻳﺴﻤﺢ ﺑﻬﺎ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻣﻄﺎﺑﻘﺔ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪/C1798M‬‬
‫ﺧﻼﻝﻃﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ‪.C567/C567M‬‬ ‫‪.C1798‬‬
‫ﻥ‪-5OTE‬ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪C1798/C1798M‬ﻳﻮﻓﺮ ﻣﺘﻄﻠﺒﺎﺕ ﺍﺳﺘﺨﺪﺍﻡ ﻭﻗﻴﺎﺱ ﻭﺇﻋﺪﺍﺩ‬
‫ﺍﻟﺘﻘﺎﺭﻳﺮﻋﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﺍﻟﻤﺮﺗﺠﻌﺔ‪ .‬ﻫﺬﻩ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﻫﻲ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺗﻠﻚ‬
‫‪6.1.7‬ﻋﻨﺪ ﺗﺤﺪﻳﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺫﺍﺕ ﺍﻟﻜﺜﺎﻓﺔ ﺍﻟﻌﺎﻟﻴﺔ ﺃﻭ ﺍﻟﻮﺯﻥ ﺍﻟﺜﻘﻴﻞ‪ ،‬ﻳﺘﻢ‬ ‫ﺍﻟﻤﺬﻛﻮﺭﺓﻓﻲ ﻫﺬﻩ ﺍﻟﻮﺛﻴﻘﺔ‪ .‬ﻳﻤﻜﻦ ﻟﻠﻤﺸﺘﺮﻱ ﺃﻥ ﻳﻮﺿﺢ ﺃﻳﻀﺎً ﺃﻱ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺿﻤﻦ‬
‫ﺗﺤﺪﻳﺪﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‪ ،‬ﻭ‬ ‫ﺍﻟﻄﻠﺐ‪،‬ﻣﺜﻞ ﺍﻟﻤﺨﺎﻟﻴﻂ ﺃﻭ ﺍﻟﺘﻄﺒﻴﻘﺎﺕ ﺍﻟﻤﺤﺪﺩﺓ‪ ،‬ﻗﺪ ﺗﺘﻀﻤﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‬
‫ﺍﻟﻤﻌﺎﺩﺓ‪.‬‬
‫ﻥ‪ -8OTE‬ﺗﺤﺘﻮﻱ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻋﺎﻟﻴﺔ ﺍﻟﻜﺜﺎﻓﺔ ﺃﻭ ﺍﻟﻮﺯﻥ ﺍﻟﺜﻘﻴﻞ ﻋﺎﺩﺓ ﻋﻠﻰ ﺭﻛﺎﻡ ﺑﻜﺜﺎﻓﺔ‬
‫ﻧﺴﺒﻴﺔﺗﺒﻠﻎ ‪ 3.3‬ﺃﻭ ﺃﻛﺜﺮ ﻣﻄﺎﺑﻘﺔ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪ .C637‬ﻳﺘﻢ ﺍﺳﺘﺨﺪﺍﻡ ﻫﺬﻩ ﺍﻟﺨﺮﺳﺎﻧﺔ‬ ‫‪.6‬ﻃﻠﺐ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ‬
‫ﻟﻠﺤﻤﺎﻳﺔﻣﻦ ﺍﻹﺷﻌﺎﻉ ﺃﻭ ﺍﻟﺘﻄﺒﻴﻘﺎﺕ ﺍﻷﺧﺮﻯ ﺍﻟﺘﻲ ﺗﺘﻄﻠﺐ ﻛﺜﺎﻓﺔ ﺃﻋﻠﻰ ﺣﺴﺐ ﺍﻟﺘﺼﻤﻴﻢ‪.‬‬
‫ﻟﻘﺒﻮﻝﺍﻟﻜﺜﺎﻓﺔ ﻓﻲ ﻭﻗﺖ ﺍﻟﺘﺴﻠﻴﻢ‪ ،‬ﻳﺠﺐ ﺇﻧﺸﺎء ﻋﻼﻗﺔ ﺑﻴﻦ ﺍﻟﻜﺜﺎﻓﺔ ﺍﻟﻄﺎﺯﺟﺔ ﻭﻛﺜﺎﻓﺔ‬
‫‪6.1‬ﻓﻲ ﺣﺎﻟﺔ ﻋﺪﻡ ﻭﺟﻮﺩ ﻣﻮﺍﺻﻔﺎﺕ ﻋﺎﻣﺔ ﻣﻌﻤﻮﻝ ﺑﻬﺎ‪ ،‬ﻳﺠﺐ ﺃﻥ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻤﺘﺼﻠﺒﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﺣﺴﺐ ﺍﻟﺘﺼﻤﻴﻢ‪.‬‬ ‫ﻳﺘﻀﻤﻦﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ ﻣﺎ ﻳﻠﻲ‪:‬‬

‫‪6.1.1‬ﺍﻟﺤﺠﻢ ﺃﻭ ﺍﻷﺣﺠﺎﻡ ﺍﻟﻤﻌﻴﻨﺔ ﻟﻠﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ‪،‬‬


‫‪،6.1.8‬ﺇﺫﺍ ﺭﻏﺒﺖ ﻓﻲ ﺫﻟﻚ‪ ،‬ﺃﻱ ﻣﻦ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻻﺧﺘﻴﺎﺭﻳﺔ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ﺍﻟﺠﺪﻭﻝ‬
‫‪6.1.2‬ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﺍﻟﻤﺮﻏﻮﺏ ﻓﻴﻪ ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﺴﻠﻴﻢ )ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ‪7‬‬
‫‪2‬ﻓﻲ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.C1602/C1602M‬‬
‫ﻟﻠﺘﺴﺎﻣﺢﻣﻘﺒﻮﻝ(‪،‬‬
‫‪6.1.9‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺃﻥ ﻳﺬﻛﺮ ﺃﻱ ﺣﺪ ﻟﺪﻭﺭﺓ ﺍﻷﺳﻄﻮﺍﻧﺔ ﻓﻴﻤﺎ‬
‫‪6.1.3‬ﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ‪ ،‬ﺃﻭ ﺍﻟﺘﺪﻓﻘﺎﺕ‪ ،‬ﺍﻟﻤﺮﻏﻮﺑﺔ ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﺴﻠﻴﻢ )‬
‫ﻳﺘﻌﻠﻖﺑﺎﻟﻮﻗﺖ ﺍﻟﺬﻱ ﻳﺠﺐ ﺃﻥ ﻳﺒﺪﺃ ﻓﻴﻪ ﺗﻔﺮﻳﻎ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ .‬ﺇﺫﺍ ﻟﻢ ﻳﺬﻛﺮ‬
‫ﺍﻧﻈﺮﺍﻟﻘﺴﻢ‪7‬ﻟﻠﺘﺴﺎﻣﺢ ﻣﻘﺒﻮﻝ(‪،‬‬
‫ﺍﻟﻤﺸﺘﺮﻱﺣﺪﺍً ﻟﺜﻮﺭﺓ ﺍﻷﺳﻄﻮﺍﻧﺔ‪ ،‬ﻓﻴﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺗﺤﺪﻳﺪ‬
‫‪6.1.4‬ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﺴﻠﻴﻢ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ‬
‫ﺍﻟﺤﺪﻭﺇﺑﻼﻏﻪ ﺇﻟﻰ ﺍﻟﻤﺸﺘﺮﻱ ﻗﺒﻞ ﺍﻟﺘﺴﻠﻴﻢ‪.‬‬
‫ﺳﺘﺘﻌﺮﺽﻟﺪﻭﺭﺍﺕ ﺍﻟﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ ﺃﻭ ﺍﻟﺘﻌﺮﺽ ﺍﻟﻤﺘﻮﻗﻊ ﻟﻠﺨﺮﺳﺎﻧﺔ )‬
‫‪6.2‬ﻓﻲ ﺣﺎﻟﺔ ﺗﻄﺒﻴﻖ ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﻤﺸﺮﻭﻉ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻀﻤﻦ ﺍﻷﻣﺮ‬ ‫ﺍﻧﻈﺮﺍﻟﻘﺴﻢ‪8‬ﻷﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ ﻻﺧﺘﺒﺎﺭﺍﺕ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻭﺍﻟﺘﻔﺎﻭﺗﺎﺕ(‪.‬‬
‫ﺍﻟﻤﺘﻄﻠﺒﺎﺕﺍﻟﻤﻄﺒﻘﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﺳﻴﺘﻢ ﺇﻧﺘﺎﺟﻬﺎ ﻭﻓﻘﺎً ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪.‬‬
‫ﻥ‪-6OTE‬ﺍﻟﺠﺪﻭﻝ ‪1‬ﻳﻮﻓﺮ ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻳﺎﺕ ﺍﻟﻬﻮﺍء ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﺗﺨﺘﻠﻒ ﺣﺴﺐ‬
‫‪6.3‬ﺇﺫﺍ ﻛﺎﻥ ﻧﻮﻉ ﺃﻭ ﻧﻮﻉ ﺃﻭ ﻓﺉﺔ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻲ‬ ‫ﺣﺎﻟﺔﺍﻟﺘﻌﺮﺽ ﻭﺍﻟﺤﺠﻢ ﺍﻟﻜﻠﻲ‪ .‬ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻳﺎﺕ ﺍﻟﻬﻮﺍء ﺃﻗﻞ ﻣﻦ ﺗﻠﻚ ﺍﻟﻤﺒﻴﻨﺔ ﻓﻲ‬
‫ﺍﻟﺠﺪﻭﻝ‪1‬ﻳﻤﻜﻦ ﺗﺤﺪﻳﺪﻫﺎ ﺃﻭ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻻ ﺗﺨﻀﻊ ﻟﻠﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ‪.‬‬
‫‪5.2.1‬ﻭ‪5.2.2‬ﻟﻢ ﻳﺘﻢ ﺗﺤﺪﻳﺪﻫﺎ ﻣﻦ ﻗﺒﻞ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻳﺴُﻤﺢ ﺑﺎﺳﺘﺨﺪﺍﻡ‬
‫ﻳﻤﻜﻦﺍﻟﻘﻴﺎﻡ ﺑﺬﻟﻚ ﻟﺘﺤﺴﻴﻦ ﻗﺎﺑﻠﻴﺔ ﺍﻟﺘﺸﻐﻴﻞ ﻭﺍﻟﺘﻤﺎﺳﻚ‪ ،‬ﺃﻭ ﺗﻘﻠﻴﻞ ﻣﻌﺪﻝ ﺍﻟﻨﺰﻳﻒ‪ ،‬ﺃﻭ‬
‫ﺍﻟﻤﻮﺍﺩﺍﻷﺳﻤﻨﺘﻴﺔ ﻓﻲ ﺍﻟﺨﻠﻄﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﻴﺔ ﺍﻟﺘﻲ ﺗﻠﺒﻲ ﺧﺼﺎﺉﺺ‬ ‫ﺗﻘﻠﻴﻞﻣﺤﺘﻮﻯ ﺍﻟﻤﺎء ﻟﺘﻨﺎﺳﻖ ﻣﻌﻴﻦ‪ ،‬ﺃﻭ ﺗﺤﻘﻴﻖ ﻛﺜﺎﻓﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ ﺍﻟﻤﻄﻠﻮﺑﺔ‪.‬‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﻭﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﺸﺘﺮﻱ ﺍﻷﺧﺮﻯ ﺣﺴﺐ ﺍﻟﻄﻠﺐ‪.‬‬ ‫ﺇﺟﻤﺎﻟﻲﻣﺤﺘﻮﻳﺎﺕ ﺍﻟﻬﻮﺍء ﺍﻟﻤﺤﺪﺩﺓ ﺃﻋﻠﻰ ﻣﻦ ﺗﻠﻚ ﺍﻟﻤﻮﺿﺤﺔ ﻓﻲﺍﻟﺠﺪﻭﻝ ‪1‬ﻗﺪ ﻳﻘﻠﻞ ﻣﻦ‬
‫ﺍﻟﻘﻮﺓﺩﻭﻥ ﺃﻱ ﺗﺤﺴﻴﻦ ﺇﺿﺎﻓﻲ ﻟﻠﻤﺘﺎﻧﺔ‪.‬‬

‫‪6.4‬ﺍﻟﺨﻴﺎﺭ ﺃ‪:‬‬ ‫ﻇﺮﻭﻑﺍﻟﺘﻌﺮﺽ ﻟﺒﻴﺉﺎﺕ ﺍﻟﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ ﻓﻲﺍﻟﺠﺪﻭﻝ ‪ 1‬ﺗﺘﻮﺍﻓﻖ ﻣﻊ ﻣﺎ ﻳﻠﻲ‪:‬‬


‫‪6.4.1‬ﻋﻨﺪﻣﺎ ﻳﻄﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ ﻣﻦ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺗﺤﻤﻞ‬
‫ﺍﻟﺘﻌﺮﺽﺍﻟﻤﻌﺘﺪﻝ—ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻌﺮﺿﺔ ﻟﺪﻭﺭﺍﺕ ﺍﻟﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ ﻭﻟﻜﻦ ﻟﻴﺴﺖ‬
‫ﺍﻟﻤﺴﺆﻭﻟﻴﺔﺍﻟﻜﺎﻣﻠﺔ ﻋﻦ ﺍﺧﺘﻴﺎﺭ ﺍﻟﻨﺴﺐ ﻟﻠﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ )ﺍﻟﻤﻼﺣﻈﺔ ‪،(9‬‬
‫ﻋﻠﻰﺍﺗﺼﺎﻝ ﺑﺎﻷﺭﺽ ﺃﻭ ﻣﻊ ﺗﻌﺮﺽ ﻣﺤﺪﻭﺩ ﻟﻠﻤﻴﺎﻩ‪ ،‬ﻣﻤﺎ ﻳﺤﺪ ﻣﻦ ﺍﻟﻘﺪﺭﺓ ﻋﻠﻰ ﺍﻟﺘﺴﺒﺐ‬
‫ﻳﺠﺐﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺃﻳﻀﺎً ﺗﺤﺪﻳﺪ ﻣﺎ ﻳﻠﻲ‪:‬‬ ‫ﻓﻲﺗﺸﺒﻊ ﺟﺰء ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻗﺒﻞ ﺍﻟﺘﺠﻤﻴﺪ‪ .‬ﻳﺠﺐ ﺃﻻ ﺗﺘﻠﻘﻰ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺃﻣﻼﺡ ﺍﻟﺘﺬﻭﻳﺐ‬
‫ﺃﻭﻏﻴﺮﻫﺎ ﻣﻦ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ ﺍﻟﻌﺪﻭﺍﻧﻴﺔ‪ .‬ﺗﺸﻤﻞ ﺍﻷﻣﺜﻠﺔ‪ :‬ﺍﻟﻌﻮﺍﺭﺽ ﺍﻟﺨﺎﺭﺟﻴﺔ‪،‬‬
‫‪6.4.1.1‬ﺗﻢ ﺗﻘﻴﻴﻢ ﻣﺘﻄﻠﺒﺎﺕ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﺤﺪﺩ ﻓﻲ‬ ‫ﻭﺍﻷﻋﻤﺪﺓ‪،‬ﻭﺍﻟﺠﺪﺭﺍﻥ‪ ،‬ﻭﺍﻟﻌﻮﺍﺭﺽ‪ ،‬ﻭﺍﻟﻘﻮﺍﻋﺪ ﺍﻟﻤﻮﺟﻮﺩﺓ ﺃﺳﻔﻞ ﺧﻂ ﺍﻟﺼﻘﻴﻊ‪ ،‬ﺃﻭ ﺍﻷﻟﻮﺍﺡ‬
‫ﺍﻟﻤﺮﺗﻔﻌﺔﺣﻴﺚ ﻻ ﻳﺘُﻮﻗﻊ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻠﺢ ﺇﺯﺍﻟﺔ ﺍﻟﺠﻠﻴﺪ‪ .‬ﺗﺘﻮﺍﻓﻖ ﻣﺘﻄﻠﺒﺎﺕ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‬
‫ﺍﻟﻌﻴﻨﺎﺕﺍﻟﻤﺄﺧﻮﺫﺓ ﻣﻦ ﻭﺣﺪﺓ ﺍﻟﻨﻘﻞ ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﻔﺮﻳﻎ ﻭﻓﻘﺎً ﻟﻠﻘﺴﻢ‪.18‬‬
‫ﻟﻬﺬﺍﺍﻟﺘﻌﺮﺽ ﻣﻊ ﻣﺘﻄﻠﺒﺎﺕ ﻓﺉﺔ ﺍﻟﺘﻌﺮﺽ ‪ F1‬ﻣﻦ ‪.ACI 318‬‬
‫ﻳﺠﺐﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺗﺤﺪﻳﺪ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﻣﻦ ﺣﻴﺚ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻟﻠﻌﻴﻨﺎﺕ‬
‫ﺍﻟﻘﻴﺎﺳﻴﺔﺍﻟﻤﻌﺎﻟﺠﺔ ﻓﻲ ﻇﻞ ﻇﺮﻭﻑ ﻣﻌﻤﻠﻴﺔ ﻗﻴﺎﺳﻴﺔ ﻟﻠﻤﻌﺎﻟﺠﺔ ﺍﻟﺮﻃﺒﺔ )‬ ‫ﺍﻟﺘﻌﺮﺽﺍﻟﺸﺪﻳﺪ—ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻌﺮﺿﺔ ﻟﺪﻭﺭﺍﺕ ﺍﻟﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ ﺃﺛﻨﺎء ﻣﻼﻣﺴﺘﻬﺎ‬
‫ﺍﻧﻈﺮﺍﻟﻘﺴﻢ‪ .(18‬ﻣﺎ ﻟﻢ ﻳﻨﺺ ﻋﻠﻰ ﺧﻼﻑ ﺫﻟﻚ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﻟﻌﻤﺮ ﻋﻨﺪ‬ ‫ﻟﻸﺭﺽﺃﻭ ﻋﻨﺪ ﺗﻌﺮﺿﻬﺎ ﺍﻟﻤﺘﻜﺮﺭ ﻟﻠﻤﺎء‪ ،‬ﻣﻤﺎ ﻗﺪ ﻳﺘﺴﺒﺐ ﻓﻲ ﺗﺸﺒﻊ ﺟﺰء ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺍﻻﺧﺘﺒﺎﺭ‪ 28‬ﻳﻮﻣﺎً‪.‬‬ ‫ﻗﺒﻞﺍﻟﺘﺠﻤﻴﺪ‪ .‬ﻗﺪ ﺗﺘﻠﻘﻰ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﻮﺍﺩ ﻛﻴﻤﻴﺎﺉﻴﺔ ﻣﺬﻳﺒﺔ ﺃﻭ ﻣﻮﺍﺩ ﻛﻴﻤﻴﺎﺉﻴﺔ ﻋﺪﻭﺍﻧﻴﺔ‬
‫ﺃﺧﺮﻯ‪.‬ﺗﺸﻤﻞ ﺍﻷﻣﺜﻠﺔ‪ :‬ﺍﻷﺭﺻﻔﺔ‪ ،‬ﺃﻭ ﺃﺳﻄﺢ ﺍﻟﺠﺴﻮﺭ‪ ،‬ﺃﻭ ﺍﻷﺭﺻﻔﺔ‪ ،‬ﺃﻭ ﺍﻟﻤﺰﺍﺭﻳﺐ‪ ،‬ﺃﻭ‬
‫ﺍﻷﺭﺻﻔﺔ‪،‬ﺃﻭ ﺑﻄﺎﻧﺎﺕ ﺍﻟﻘﻨﻮﺍﺕ‪ ،‬ﺃﻭ ﺧﺰﺍﻧﺎﺕ ﺃﻭ ﺃﺣﻮﺍﺽ ﺍﻟﻤﻴﺎﻩ ﺍﻟﺨﺎﺭﺟﻴﺔ‪ .‬ﺗﺘﻮﺍﻓﻖ‬
‫ﻥ‪ -9OTE‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻋﻨﺪ ﺍﺧﺘﻴﺎﺭ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻟﺘﻲ ﻳﺘﺤﻤﻞ ﻣﺴﺆﻭﻟﻴﺘﻬﺎ‪ ،‬ﺃﻥ‬ ‫ﻣﺘﻄﻠﺒﺎﺕﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻬﺬﺍ ﺍﻟﺘﻌﺮﺽ ﻣﻊ ﻣﺘﻄﻠﺒﺎﺕ ﻓﺉﺘﻲ ﺍﻟﺘﻌﺮﺽ ‪ F2‬ﻭ‪ F3‬ﻓﻲ‬
‫ﻳﺄﺧﺬﻓﻲ ﺍﻻﻋﺘﺒﺎﺭ ﻣﺘﻄﻠﺒﺎﺕ ﻗﺎﺑﻠﻴﺔ ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﻭﻗﺎﺑﻠﻴﺔ ﺍﻟﻮﺿﻊ‪ ،‬ﻭﺍﻟﻤﺘﺎﻧﺔ‪ ،‬ﻭﻣﻠﻤﺲ‬ ‫‪.ACI318‬‬
‫ﺍﻟﺴﻄﺢ‪،‬ﻭﺍﻟﻜﺜﺎﻓﺔ‪ ،‬ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﺘﺼﻤﻴﻢ ﺍﻹﻧﺸﺎﺉﻲ‪ .‬ﺗﺘﻢ ﺇﺣﺎﻟﺔ ﺍﻟﻤﺸﺘﺮﻱ‬
‫ﺇﻟﻰ‪ Standard Practice ACI 211.1‬ﻭ ‪ Standard Practice ACI 211.2‬ﻻﺧﺘﻴﺎﺭ‬ ‫‪6.1.5‬ﺃﻱ ﻣﻦ ﺍﻟﺨﻴﺎﺭﺍﺕ )ﺃ( ﺃﻭ )ﺏ( ﺃﻭ )ﺝ( ﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻣﻪ ﻛﺄﺳﺎﺱ‬
‫ﺍﻟﻨﺴﺐﺍﻟﺘﻲ ﺳﺘﺆﺩﻱ ﺇﻟﻰ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺧﺮﺳﺎﻧﺔ ﻣﻨﺎﺳﺒﺔ ﻷﻧﻮﺍﻉ ﻣﺨﺘﻠﻔﺔ ﻣﻦ ﺍﻟﻬﻴﺎﻛﻞ‬ ‫ﻟﺘﺤﺪﻳﺪﻧﺴﺐ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻹﻧﺘﺎﺝ ﺍﻟﺠﻮﺩﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ‪،‬‬
‫ﻭﻇﺮﻭﻑﺍﻟﺘﻌﺮﺽ‪ .‬ﻻ ﻳﻤﻜﻦ ﺗﺤﺪﻳﺪ ﻧﺴﺒﺔ ﺍﻟﻤﺎء ﺇﻟﻰ ﺍﻷﺳﻤﻨﺖ ﻓﻲ ﻣﻌﻈﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺍﻟﻬﻴﻜﻠﻴﺔﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ ﺑﺪﻗﺔ ﻛﺎﻓﻴﺔ ﻻﺳﺘﺨﺪﺍﻣﻬﺎ ﻛﺄﺳﺎﺱ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪.‬‬
‫‪6.1.6‬ﻋﻨﺪ ﺗﺤﺪﻳﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺧﻔﻴﻔﺔ ﺍﻟﻮﺯﻥ‪ ،‬ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﻛﺜﺎﻓﺔ ﺍﻟﺘﻮﺍﺯﻥ‪،‬‬

‫ﺍﻟﺠﺪﻭﻝ‪ 1‬ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺤﺒﻮﺳﺔ ﺑﺎﻟﻬﻮﺍء ﺍﻟﻤﻌﺮﺿﺔ ﻟﺪﻭﺭﺍﺕ ﺍﻟﺘﺠﻤﻴﺪ ﻭﺍﻟﺬﻭﺑﺎﻥ‬
‫ﺇﺟﻤﺎﻟﻲﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‪% ،‬‬
‫ﺍﻟﺤﺪﺍﻷﻗﺼﻰ ﻟﻸﺣﺠﺎﻡ ﺍﻻﺳﻤﻴﺔ ﻟﻠﺮﻛﺎﻡ‪ ،‬ﻣﻢ ]ﺑﻮﺻﺔ[‬ ‫ﺍﻟﺘﻌﺮﺽ‬
‫‪[3]75.0‬‬ ‫‪[2]50.0‬‬ ‫‪[2⁄11]37.5‬‬ ‫‪[1]25.0‬‬ ‫‪[4⁄3]19.0‬‬ ‫‪[2⁄1]12.5‬‬ ‫‪[8⁄3]9.5‬‬ ‫ﺣﺎﻟﺔ‬
‫)ﻳﺮﻯﻣﻼﺣﻈﺔ ‪(6‬‬
‫‪3.5‬‬ ‫‪4.0‬‬ ‫‪4.5‬‬ ‫‪4.5‬‬ ‫‪5.0‬‬ ‫‪5.5‬‬ ‫‪6.0‬‬ ‫ﻣﻌﺘﺪﻝ‬
‫‪4.5‬‬ ‫‪5.0‬‬ ‫‪5.5‬‬ ‫‪6.0‬‬ ‫‪6.0‬‬ ‫‪7.0‬‬ ‫‪7.5‬‬ ‫ﺷﺪﻳﺪ‬

‫‪3‬‬
‫ﺃ‪C94/C94M - 17‬‬
‫ﺍﻟﻤﻤﺎﺭﺳﺔﺍﻟﻘﻴﺎﺳﻴﺔ ‪ 211.2‬ﺍﻟﻤﺸﺎﺭ ﺇﻟﻴﻬﺎ ﻓﻲﺍﻟﻤﻼﺣﻈﺔ ‪.9‬‬ ‫‪6.4.2‬ﺑﻨﺎء ﻋﻠﻰ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‪ ،‬ﻗﺒﻞ‬
‫‪6.6.2‬ﺑﻨﺎء ﻋﻠﻰ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‪ ،‬ﻗﺒﻞ‬ ‫ﺍﻟﺘﺴﻠﻴﻢﺍﻟﻔﻌﻠﻲ ﻟﻠﺨﺮﺳﺎﻧﺔ‪ ،‬ﺗﻘﺪﻳﻢ ﺑﻴﺎﻥ ﺇﻟﻰ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻣﻊ ﺇﻋﻄﺎء ﺍﻟﻜﺘﻞ‬
‫ﺍﻟﺘﺴﻠﻴﻢﺍﻟﻔﻌﻠﻲ ﻟﻠﺨﺮﺳﺎﻧﺔ‪ ،‬ﺗﻘﺪﻳﻢ ﺑﻴﺎﻥ ﺇﻟﻰ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻣﻊ ﺇﻋﻄﺎء ﺍﻟﻜﺘﻞ‬ ‫ﺍﻟﺠﺎﻓﺔﻣﻦ ﺍﻷﺳﻤﻨﺖ ﻭﺍﻟﻜﺘﻞ ﺍﻟﺠﺎﻓﺔ ﺍﻟﺴﻄﺤﻴﺔ ﺍﻟﻤﺸﺒﻌﺔ ﻣﻦ ﺍﻟﺮﻛﺎﻡ‬
‫ﺍﻟﺠﺎﻓﺔﻣﻦ ﺍﻷﺳﻤﻨﺖ ﻭﺍﻟﻜﺘﻞ ﺍﻟﺠﺎﻓﺔ ﺍﻟﺴﻄﺤﻴﺔ ﺍﻟﻤﺸﺒﻌﺔ ﻣﻦ ﺍﻟﺮﻛﺎﻡ‬ ‫ﺍﻟﻨﺎﻋﻢﻭﺍﻟﺨﺸﻦ ﻭﺍﻟﻜﻤﻴﺎﺕ ﻭﻧﻮﻉ ﻭﺍﺳﻢ ﺍﻟﺨﻠﻄﺎﺕ )ﺇﻥ ﻭﺟﺪﺕ( ﻭﻛﻤﻴﺔ ﺍﻟﻤﺎء‬
‫ﺍﻟﻨﺎﻋﻢﻭﺍﻟﺨﺸﻦ ﻭﺍﻟﻜﻤﻴﺎﺕ‪ ،‬ﻧﻮﻉ ﻭﺍﺳﻢ ﺍﻟﺨﻠﻴﻂ )ﺇﻥ ﻭﺟﺪ( ﻭﻛﻤﻴﺔ ﺍﻟﻤﺎء ﻟﻜﻞ‬ ‫ﻟﻜﻞﻳﺎﺭﺩﺓ ﻣﻜﻌﺒﺔ ﺃﻭ ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﺳﻴﺘﻢ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ‬
‫ﻳﺎﺭﺩﺓﻣﻜﻌﺒﺔ ﺃﻭ ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﺳﻴﺘﻢ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻓﻲ‬ ‫ﻓﻲﺗﺼﻨﻴﻊ ﻛﻞ ﻓﺉﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻳﻄﻠﺒﻬﺎ ﺍﻟﻤﺸﺘﺮﻱ‪ .‬ﻳﺠﺐ ﻋﻠﻰ‬
‫ﺗﺼﻨﻴﻊﻛﻞ ﻓﺉﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻳﻄﻠﺒﻬﺎ ﺍﻟﻤﺸﺘﺮﻱ‪ .‬ﻭﻳﺠﺐ ﻋﻠﻴﻪ ﺃﻳﻀﺎً‬ ‫ﺍﻟﺸﺮﻛﺔﺍﻟﻤﺼﻨﻌﺔ ﺃﻳﻀﺎً ﺗﻘﺪﻳﻢ ﺩﻟﻴﻞ ﻣﻘﻨﻊ ﻟﻠﻤﺸﺘﺮﻱ ﻋﻠﻰ ﺃﻥ ﺍﻟﻤﻮﺍﺩ‬
‫ﺗﻘﺪﻳﻢﺩﻟﻴﻞ ﻣﻘﻨﻊ ﻟﻠﻤﺸﺘﺮﻱ ﻋﻠﻰ ﺃﻥ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺘﻲ ﺳﻴﺘﻢ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ‬ ‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔﻭﺍﻟﻨﺴﺐ ﺍﻟﻤﺨﺘﺎﺭﺓ ﺳﺘﻨﺘﺞ ﺧﺮﺳﺎﻧﺔ ﺑﺎﻟﺠﻮﺩﺓ ﺍﻟﻤﺤﺪﺩﺓ‪.‬‬
‫ﻭﺍﻟﻨﺴﺐﺍﻟﻤﺨﺘﺎﺭﺓ ﺳﺘﻨﺘﺞ ﺧﺮﺳﺎﻧﺔ ﺑﺎﻟﺠﻮﺩﺓ ﺍﻟﻤﺤﺪﺩﺓ‪ .‬ﻭﻣﻬﻤﺎ ﻛﺎﻧﺖ ﻧﻘﺎﻁ‬
‫ﺍﻟﻘﻮﺓﺍﻟﺘﻲ ﺗﻢ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻴﻬﺎ ﻓﺈﻥ ﻛﻤﻴﺔ ﺍﻷﺳﻤﻨﺖ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻳﺠﺐ ﺃﻻ‬
‫ﺗﻘﻞﻋﻦ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﺍﻟﻤﺤﺪﺩ‪.‬‬ ‫‪6.5‬ﺍﻟﺨﻴﺎﺭ ﺏ‪:‬‬
‫‪6.5.1‬ﻋﻨﺪﻣﺎ ﻳﺘﺤﻤﻞ ﺍﻟﻤﺸﺘﺮﻱ ﻣﺴﺆﻭﻟﻴﺔ ﻧﺴﺐ ﺍﻟﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ‪،‬‬
‫ﻳﺠﺐﻋﻠﻴﻪ ﺃﻳﻀﺎً ﺗﺤﺪﻳﺪ ﻣﺎ ﻳﻠﻲ‪:‬‬
‫‪6.7‬ﻳﺠﺐ ﺗﻌﻴﻴﻦ ﺍﻟﻨﺴﺐ ﺍﻟﺘﻲ ﺗﻢ ﺍﻟﺘﻮﺻﻞ ﺇﻟﻴﻬﺎ ﺑﻮﺍﺳﻄﺔ ﺍﻟﺨﻴﺎﺭﺍﺕ )ﺃ(‬
‫ﺃﻭ)ﺏ( ﺃﻭ )ﺝ( ﻟﻜﻞ ﻓﺉﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﺍﻟﻤﻌﺘﻤﺪﺓ ﻟﻼﺳﺘﺨﺪﺍﻡ ﻓﻲ‬ ‫‪6.5.1.1‬ﻣﺤﺘﻮﻯ ﺍﻷﺳﻤﻨﺖ ﺑﺎﻟﻜﻴﻠﻮ ﺟﺮﺍﻡ ﻟﻜﻞ ﻣﺘﺮ ﻣﻜﻌﺐ ]ﺭﻃﻞ ﻟﻜﻞ‬
‫ﺍﻟﻤﺸﺮﻭﻉﺑﺘﺴﻤﻴﺔ ﻟﺘﺴﻬﻴﻞ ﺗﺤﺪﻳﺪ ﻛﻞ ﺧﻠﻴﻂ ﺧﺮﺳﺎﻧﻲ ﻳﺘﻢ ﺗﺴﻠﻴﻤﻪ‬ ‫ﻳﺎﺭﺩﺓﻣﻜﻌﺒﺔ[ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‪،‬‬
‫ﻟﻠﻤﺸﺮﻭﻉ‪.‬ﻭﻫﺬﺍ ﻫﻮ ﺍﻟﺘﻌﻴﻴﻦ ﺍﻟﻤﻄﻠﻮﺏ ﻓﻲ‪14.1.7‬ﻭﻳﻘﺪﻡ ﻣﻌﻠﻮﻣﺎﺕ ﻋﻦ‬ ‫‪6.5.1.2‬ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻤﺤﺘﻮﻯ ﺍﻟﻤﺎء ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﺑﺎﻟﻠﺘﺮ ﻟﻜﻞ ﻣﺘﺮ‬
‫ﺍﻟﻨﺴﺐﺍﻟﻤﻠﻤﻮﺳﺔ ﻋﻨﺪﻣﺎ ﻻ ﻳﺘﻢ ﺗﻘﺪﻳﻤﻬﺎ ﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ ﻓﻲ ﻛﻞ ﺗﺬﻛﺮﺓ‬ ‫ﻣﻜﻌﺐ]ﺟﺎﻟﻮﻥ ﻟﻜﻞ ﻳﺎﺭﺩﺓ ﻣﻜﻌﺒﺔ[ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﺑﻤﺎ ﻓﻲ ﺫﻟﻚ ﺍﻟﺮﻃﻮﺑﺔ‬
‫ﺗﺴﻠﻴﻢﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ‪ .14.2‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻧﺴﺨﺔ ﻣﺼﺪﻗﺔ ﻣﻦ‬ ‫ﺍﻟﺴﻄﺤﻴﺔﻋﻠﻰ ﺍﻟﺮﻛﺎﻡ‪ ،‬ﻭﻟﻜﻦ ﺑﺎﺳﺘﺜﻨﺎء ﻣﺎء ﺍﻻﻣﺘﺼﺎﺹ )ﺍﻟﻤﻼﺣﻈﺔ ‪ ،(9‬ﻭ‬
‫ﺟﻤﻴﻊﺍﻟﻨﺴﺐ ﺍﻟﻤﺤﺪﺩﺓ ﻓﻲ ﺍﻟﺨﻴﺎﺭﺍﺕ ‪ A‬ﺃﻭ ‪ B‬ﺃﻭ ‪ C‬ﻣﺴﺠﻠﺔ ﻓﻲ ﻣﺼﻨﻊ‬
‫ﺍﻟﺨﻠﻂ‪.‬‬ ‫‪6.5.1.3‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﻨﺎﻙ ﺣﺎﺟﺔ ﺇﻟﻰ ﻣﻮﺍﺩ ﺇﺿﺎﻓﻴﺔ‪ ،‬ﻧﻮﻋﻬﺎ ﻭﺍﺳﻤﻬﺎ‬
‫ﻭﺍﻟﺠﺮﻋﺔﺍﻟﻤﺴﺘﺨﺪﻣﺔ‪ .‬ﻭﻻ ﻳﺠﻮﺯ ﺗﻘﻠﻴﻞ ﻣﺤﺘﻮﻯ ﺍﻷﺳﻤﻨﺖ ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ‬
‫ﺍﻟﺨﻠﻄﺎﺕﺑﻤﻮﺟﺐ ﻫﺬﺍ ﺍﻟﺨﻴﺎﺭ ﺩﻭﻥ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻣﻮﺍﻓﻘﺔ ﻛﺘﺎﺑﻴﺔ ﻣﻦ‬
‫‪6.8‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﺗﺰﻭﻳﺪ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺑﻨﺴﺦ‬
‫ﺍﻟﻤﺸﺘﺮﻱ‪.‬‬
‫ﻣﻦﺟﻤﻴﻊ ﺗﻘﺎﺭﻳﺮ ﺍﻻﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﺘﻲ ﺗﻢ ﺇﺟﺮﺍﺅﻫﺎ ﻋﻠﻰ ﻋﻴﻨﺎﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫‪6.5.2‬ﺑﻨﺎء ًﻋﻠﻰ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‪ ،‬ﻗﺒﻞ‬
‫ﺍﻟﻤﺄﺧﻮﺫﺓﻟﺘﺤﺪﻳﺪ ﻣﺪﻯ ﻣﻄﺎﺑﻘﺘﻬﺎ ﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ .‬ﻳﺠﺐ ﺗﻘﺪﻳﻢ‬
‫ﺍﻟﺘﺴﻠﻴﻢﺍﻟﻔﻌﻠﻲ ﻟﻠﺨﺮﺳﺎﻧﺔ‪ ،‬ﺗﻘﺪﻳﻢ ﺑﻴﺎﻥ ﺇﻟﻰ ﺍﻟﻤﺸﺘﺮﻱ ﻳﻮﺿﺢ ﻣﺼﺎﺩﺭ‬
‫ﺍﻟﺘﻘﺎﺭﻳﺮﻓﻲ ﺍﻟﻮﻗﺖ ﺍﻟﻤﻨﺎﺳﺐ‪.‬‬
‫ﻭﻛﺜﺎﻓﺎﺕﻭﺗﺤﻠﻴﻼﺕ ﺍﻟﻐﺮﺑﺎﻝ ﻟﻠﺮﻛﺎﻡ ﻭﺍﻟﻜﺘﻞ ﺍﻟﺠﺎﻓﺔ ﻣﻦ ﺍﻷﺳﻤﻨﺖ ﻭﺍﻟﻤﻮﺍﺩ‬
‫‪6.9‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺇﺫﻥ ﺍﻟﻤﺸﺘﺮﻱ ﻟﺪﻣﺞ‬ ‫ﺍﻟﻤﺸﺒﻌﺔ‪.‬ﺍﻟﻜﺘﻞ ﺍﻟﺴﻄﺤﻴﺔ ﺍﻟﺠﺎﻓﺔ ﻣﻦ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻨﺎﻋﻢ ﻭﺍﻟﺨﺸﻦ ﻭﻛﻤﻴﺎﺗﻪ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻄﺎﺯﺟﺔ ﺍﻟﻤﻌﺎﺩﺓ‪.‬‬ ‫ﻭﻧﻮﻉﻭﺍﺳﻢ ﺍﻟﺨﻠﻴﻂ )ﺇﻥ ﻭﺟﺪ( ﻭﺍﻟﻤﺎء ﻟﻜﻞ ﻳﺎﺭﺩﺓ ﻣﻜﻌﺒﺔ ﺃﻭ ﻣﺘﺮ ﻣﻜﻌﺐ ﻣﻦ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﺘﻲ ﺳﻴﺘﻢ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻓﻲ ﺗﺼﻨﻴﻊ ﻛﻞ ﻓﺉﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ‬
‫‪.7‬ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﻓﻲ ﺍﻟﺘﺪﻓﻖ‬ ‫ﻳﻄﻠﺒﻬﺎﺍﻟﻤﺸﺘﺮﻱ‪.‬‬
‫‪7.1‬ﻣﺎ ﻟﻢ ﻳﺤﺪﺩ ﺍﻟﻤﺸﺘﺮﻱ ﺗﻔﺎﻭﺗﺎﺕ ﺃﺧﺮﻯ‪ ،‬ﻳﺠﺐ ﺗﻄﺒﻴﻖ ﻣﺎ ﻳﻠﻲ‪.‬‬

‫‪7.1.1‬ﻋﻨﺪﻣﺎ ﻳﺬُﻛﺮ ﺍﻟﻬﺒﻮﻁ ﺑﺎﻋﺘﺒﺎﺭﻩ ﻣﻄﻠﺐ "ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ" ﺃﻭ "ﻋﺪﻡ‬ ‫‪6.6‬ﺍﻟﺨﻴﺎﺭ ﺝ‪:‬‬
‫ﺍﻟﺘﺠﺎﻭﺯ"‪:‬‬ ‫‪6.6.1‬ﻋﻨﺪﻣﺎ ﻳﻄﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ ﻣﻦ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺃﻥ ﺗﺘﺤﻤﻞ‬
‫ﺍﻟﺘﺴﺎﻣﺢﻣﻊ "ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ" ﺃﻭ "ﻋﺪﻡ ﺗﺠﺎﻭﺯ" ﺍﻟﻬﺒﻮﻁ‬
‫ﻣﺴﺆﻭﻟﻴﺔﺍﺧﺘﻴﺎﺭ ﺍﻟﻨﺴﺐ ﻟﻠﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ ﻣﻊ ﺗﺤﺪﻳﺪ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‬
‫ﺍﻟﻤﺴﻤﻮﺡﺑﻪ ﻣﻦ ﻣﺤﺘﻮﻯ ﺍﻷﺳﻤﻨﺖ )ﻣﻼﺣﻈﺔ ‪ ،(10‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ‬
‫ﺗﺴﺎﻣﺢ‬ ‫ﻟﻠﺮﻛﻮﺩﻣﻦ‪:‬‬ ‫ﺃﻳﻀﺎًﺗﺤﺪﻳﺪ ﻣﺎ ﻳﻠﻲ‪:‬‬
‫‪ 0 +‬ﻭ – ‪ 40‬ﻣﻠﻢ ]‪2⁄11‬ﻓﻲ‪[.‬‬ ‫‪75‬ﻣﻢ ]‪ 3‬ﺑﻮﺻﺔ[ ﺃﻭ ﺃﻗﻞ ﺃﻛﺜﺮ‬
‫‪ 0 +‬ﻭ – ‪ 65‬ﻣﻠﻢ ]‪2⁄12‬ﻓﻲ‪[.‬‬ ‫ﻣﻦ‪ 75‬ﻣﻢ ]‪ 3‬ﺑﻮﺻﺔ[‬ ‫‪6.6.1.1‬ﺗﻢ ﺗﻘﻴﻴﻢ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﺤﺪﺩ ﻓﻲ‬
‫‪7.1.1.1‬ﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﺃﻭ ﻋﺪﻡ ﺗﺠﺎﻭﺯ ﺷﺮﻁ ﺍﻟﻬﺒﻮﻁ‬ ‫ﺍﻟﻌﻴﻨﺎﺕﺍﻟﻤﺄﺧﻮﺫﺓ ﻣﻦ ﻭﺣﺪﺓ ﺍﻟﻨﻘﻞ ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﻔﺮﻳﻎ ﻭﻓﻘﺎً ﻟﻠﻘﺴﻢ‪.18‬‬
‫ﻓﻘﻂﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺗﺴﻤﺢ ﺑﺈﺿﺎﻓﺔ ﺍﻟﻤﺎء ﻓﻲ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ ﻭﻓﻘﺎً‬ ‫ﻳﺠﺐﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺗﺤﺪﻳﺪ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﻮﺓ ﻓﻴﻤﺎ ﻳﺘﻌﻠﻖ ﺑﺎﺧﺘﺒﺎﺭﺍﺕ‬
‫ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪.12.7‬‬ ‫ﺍﻟﻌﻴﻨﺎﺕﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻌﺎﻟﺠﺔ ﻓﻲ ﻇﻞ ﻇﺮﻭﻑ ﻣﻌﻤﻠﻴﺔ ﻗﻴﺎﺳﻴﺔ ﻟﻠﻤﻌﺎﻟﺠﺔ‬
‫ﺍﻟﺮﻃﺒﺔ)ﺍﻧﻈﺮ ﺍﻟﻘﺴﻢ‪ .(18‬ﻣﺎ ﻟﻢ ﻳﻨﺺ ﻋﻠﻰ ﺧﻼﻑ ﺫﻟﻚ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ‬
‫‪7.1.2‬ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺫﻛﺮ ﺍﻟﺮﻛﻮﺩ ﻛﻬﺪﻑ ﺃﻭ ﺭﻛﻮﺩ ﺍﺳﻤﻲ‪:‬‬
‫ﺍﻟﻌﻤﺮﻋﻨﺪ ﺍﻻﺧﺘﺒﺎﺭ ‪ 28‬ﻳﻮﻣﺎً‪.‬‬
‫ﺍﻟﺘﺴﺎﻣﺢﻣﻊ ﺍﻻﻧﺨﻔﺎﺿﺎﺕ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ﺃﻭ ﺍﻻﺳﻤﻴﺔ‬

‫ﺗﺴﺎﻣﺢ‬ ‫ﻟﻠﺮﻛﻮﺩﻣﻦ‪:‬‬ ‫‪6.6.1.2‬ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻟﻤﺤﺘﻮﻯ ﺍﻷﺳﻤﻨﺖ ﺑﺎﻟﻜﻴﻠﻮ ﺟﺮﺍﻡ ﻟﻜﻞ ﻣﺘﺮ ﻣﻜﻌﺐ‬
‫]ﺭﻃﻞ ﻟﻜﻞ ﻳﺎﺭﺩﺓ ﻣﻜﻌﺒﺔ[ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬
‫‪ 15 ±‬ﻣﻠﻢ ]‪2⁄1‬ﻓﻲ‪[.‬‬ ‫‪50‬ﻣﻠﻢ ]‪ 2‬ﺑﻮﺻﺔ[ ﻭﺃﻗﻞ‬
‫‪ ±25‬ﻣﻠﻢ ]‪ 1‬ﺑﻮﺻﺔ[‬ ‫ﺃﻛﺜﺮﻣﻦ ‪ 50‬ﺇﻟﻰ ‪ 100‬ﻣﻠﻢ ]‪ 2‬ﺇﻟﻰ ‪ 4‬ﺑﻮﺻﺎﺕ[ ﺃﻛﺜﺮ ﻣﻦ‬ ‫‪6.6.1.3‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﻨﺎﻙ ﺣﺎﺟﺔ ﺇﻟﻰ ﻣﻮﺍﺩ ﺇﺿﺎﻓﻴﺔ‪ ،‬ﻧﻮﻋﻬﺎ ﻭﺍﺳﻤﻬﺎ‬
‫‪ ±40‬ﻣﻠﻢ ]‪2⁄11‬ﻓﻲ‪[.‬‬ ‫‪100‬ﻣﻠﻢ ]‪ 4‬ﺑﻮﺻﺎﺕ[‬ ‫ﻭﺍﻟﺠﺮﻋﺔﺍﻟﻤﺴﺘﺨﺪﻣﺔ‪ .‬ﻻ ﻳﺠﻮﺯ ﺗﻘﻠﻴﻞ ﻣﺤﺘﻮﻯ ﺍﻷﺳﻤﻨﺖ ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ‬
‫‪7.1.3‬ﻋﻨﺪﻣﺎ ﻳﺬﻛﺮ ﺍﻟﻤﺸﺘﺮﻱ ﻣﺘﻄﻠﺒﺎﺕ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺫﺍﺗﻴﺔ‬ ‫ﺍﻟﺨﻠﻄﺎﺕ‪.‬‬
‫ﺍﻟﺪﻣﺞ‪:‬‬ ‫ﻥ‪ -10OTE‬ﻳﻤﻜﻦ ﺃﻥ ﻳﻜﻮﻥ ﺍﻟﺨﻴﺎﺭ ‪ C‬ﻣﻤﻴﺰﺍً ﻭﻣﻔﻴﺪﺍً ﻓﻘﻂ ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﺍﻟﻤﻌﻴﻦ‬
‫ﺍﻟﺘﺴﺎﻣﺢﻣﻊ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ‬ ‫ﻟﻤﺤﺘﻮﻯﺍﻷﺳﻤﻨﺖ ﻋﻨﺪ ﻧﻔﺲ ﺍﻟﻤﺴﺘﻮﻯ ﺍﻟﺬﻱ ﺳﻴﻜﻮﻥ ﻣﻄﻠﻮﺑﺎً ﻋﺎﺩﺓ ًﻟﻠﻘﻮﺓ‪ ،‬ﻭﺣﺠﻢ‬
‫ﺍﻟﺮﻛﺎﻡ‪،‬ﻭﺍﻟﺘﺪﻓﻖ ﺍﻟﻤﺤﺪﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ‪ .‬ﻭﻓﻲ ﺍﻟﻮﻗﺖ ﻧﻔﺴﻪ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﻜﻤﻴﺔ ﻛﺎﻓﻴﺔ‬
‫ﺗﺴﺎﻣﺢ‬ ‫ﻟﺘﺪﻓﻖﺍﻟﺮﻛﻮﺩ‬ ‫ﻟﻀﻤﺎﻥﺍﻟﻤﺘﺎﻧﺔ ﻓﻲ ﻇﻞ ﻇﺮﻭﻑ ﺍﻟﺨﺪﻣﺔ ﺍﻟﻤﺘﻮﻗﻌﺔ‪ ،‬ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﻠﻤﺲ ﺍﻟﺴﻄﺢ‬
‫ﻭﻛﺜﺎﻓﺘﻪﺍﻟﻤﺮُﺿﻴﺔ‪ ،‬ﻓﻲ ﺣﺎﻟﺔ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ ﻣﻌﻬﺎ‪ .‬ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ‬
‫‪ ±40‬ﻣﻠﻢ ]‪2⁄11‬ﺑﻮﺻﺔ‪[.‬‬ ‫ﺃﻗﻞﻣﻦ ﺃﻭ ﻳﺴﺎﻭﻱ ‪ 550‬ﻣﻠﻢ ]‪ 22‬ﺑﻮﺻﺔ[ ﺃﻛﺜﺮ ﻣﻦ‬ ‫ﻣﻌﻠﻮﻣﺎﺕﺇﺿﺎﻓﻴﺔ‪ ،‬ﺭﺍﺟﻊ ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ‪ ACI 211.1‬ﻭ‬
‫‪ 65±‬ﻣﻢ ]‪2⁄12‬ﻓﻲ‪[.‬‬ ‫‪550‬ﻣﻠﻢ ]‪ 22‬ﺑﻮﺻﺔ[‬

‫‪4‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫‪ 4%‬ﺯﻳﺎﺩﺓ‪ .‬ﻋﻨﺪﻣﺎ ﻳﻄﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ ﻃﺮﻗﺎً ﺑﺪﻳﻠﺔ ﻟﻘﻴﺎﺱ ﺍﻟﻤﻮﺍﺩ‬ ‫‪7.1.4‬ﺗﻨﻄﺒﻖ ﺍﻟﺘﻔﺎﻭﺗﺎﺕ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻬﺎ ﻟﻠﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﻋﻠﻰ ﺍﻟﻘﻴﻢ‬
‫ﺍﻷﺳﻤﻨﺘﻴﺔ‪،‬ﻳﺠﺐ ﺫﻛﺮ ﻃﺮﻕ ﺍﻟﻘﻴﺎﺱ ﻭﺇﻋﺪﺍﺩ ﺍﻟﺘﻘﺎﺭﻳﺮ ﻓﻲ ﺍﻟﻄﻠﺐ )ﺍﻧﻈﺮ‬ ‫ﺍﻟﻤﺬﻛﻮﺭﺓﻓﻲ ﺍﻟﺘﺮﺗﻴﺐ ﻋﻨﺪ ﺇﺟﺮﺍء ﺍﻟﺘﻌﺪﻳﻼﺕ ﻭﻓﻘﺎً ﻟـ‬
‫ﺍﻟﻤﻼﺣﻈﺔ‪.(12‬‬ ‫‪12.7‬ﻭ‪12.8‬ﻣﺴﻤﻮﺡ‪.‬‬
‫ﻥ‪ -12OTE‬ﻳﺠﻮﺯ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻲ ﺍﻷﻛﻴﺎﺱ ﻋﻨﺪ ﻃﻠﺐ‬ ‫‪7.2‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﺘﺎﺣﺔ ﺿﻤﻦ ﺍﻟﻨﻄﺎﻕ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﻣﻦ‬
‫ﺍﻟﻤﺸﺘﺮﻱﺃﻭ ﺳﻤﺎﺣﻪ ﺑﺬﻟﻚ‪.‬‬ ‫ﺍﻟﺮﻛﻮﺩﺃﻭ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﻟﻤﺪﺓ ‪ 30‬ﺩﻗﻴﻘﺔ ﺗﺒﺪﺃ ﺇﻣﺎ ﻋﻨﺪ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ﻣﻮﻗﻊ‬
‫‪2.9‬ﻳﺠﺐ ﻗﻴﺎﺱ ﺍﻟﺮﻛﺎﻡ ﺑﺎﻟﻜﺘﻠﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻤﻮﺯﻭﻧﺔ‬ ‫ﺍﻟﻌﻤﻞﺃﻭ ﺑﻌﺪ ﺗﻌﺪﻳﻞ ﺍﻟﺮﻛﻮﺩ ﺍﻷﻭﻟﻲ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﻓﻲ‪ ،12.7‬ﺃﻳﻬﻤﺎ ﻓﻲ‬
‫ﻫﻲﺍﻟﻜﺘﻠﺔ ﺍﻟﺠﺎﻓﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻯ ﺍﻟﺮﻃﻮﺑﺔ )‬ ‫ﻭﻗﺖﻻﺣﻖ‪ .‬ﺍﻷﻭﻝ ﻭﺍﻷﺧﻴﺮ‪4⁄1‬ﻡ‪3‬‬

‫ﺍﻟﻤﻤﺘﺼﺔﻭﺍﻟﺴﻄﺤﻴﺔ( ﻟﻠﺮﻛﺎﻡ‪.‬‬ ‫]‪4⁄1‬ﻳﺎﺭﺩﺓ‪ [3‬ﺍﻟﻤﻌﻔﺎﺓ ﻣﻦ ﻫﺬﺍ ﺍﻟﺸﺮﻁ‪ .‬ﺇﺫﺍ ﻟﻢ ﻳﻜﻦ ﺍﻟﻤﺴﺘﺨﺪﻡ ﻣﺴﺘﻌﺪﺍً‬
‫‪9.2.1‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻮﺣﺪﺍﺕ ﺍﻟﻮﺯﻥ ﺍﻟﻔﺮﺩﻳﺔ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ‬ ‫ﻟﺘﻔﺮﻳﻎﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﻦ ﺍﻟﺴﻴﺎﺭﺓ‪ ،‬ﻓﻠﻦ ﻳﻜﻮﻥ ﺍﻟﻤﻨﺘﺞ ﻣﺴﺆﻭﻻ ًﻋﻦ ﺗﺤﺪﻳﺪ ﺍﻟﺤﺪ‬
‫ﺍﻟﻤﻮﺯﻭﻥﻓﻲ ﺣﺪﻭﺩﻫﺎ‪ 2%6‬ﻣﻦ ﺍﻟﻜﺘﻠﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ؛ ﺇﻻ ﺇﺫﺍ ﻛﺎﻧﺖ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ‬ ‫ﺍﻷﺩﻧﻰﻣﻦ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﺍﻟﻬﺎﺑﻂ ﺑﻌﺪ ﺍﻧﻘﻀﺎء ‪ 30‬ﺩﻗﻴﻘﺔ ﺑﺪءﺍً ﻣﻦ‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔﺃﻗﻞ ﻣﻦ ‪ %15‬ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ‪ ،‬ﻓﻴﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ‬ ‫ﻭﺻﻮﻝﺍﻟﺴﻴﺎﺭﺓ ﺇﻟﻰ ﺍﻟﻮﺟﻬﺔ ﺍﻟﻤﺤﺪﺩﺓ ﺃﻭ ﻋﻨﺪ ﺍﻟﺘﺴﻠﻴﻢ ﺍﻟﻤﻄﻠﻮﺏ ﺍﻟﻮﻗﺖ‪،‬‬
‫ﺍﻟﻤﻮﺯﻭﻧﺔﻓﻲ ﺣﺪﻭﺩﻫﺎ‪ 0.3%6‬ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ‪.‬‬ ‫ﺃﻳﻬﻤﺎﻳﺄﺗﻲ ﻻﺣﻘﺎ‪.‬‬

‫‪9.2.2‬ﺑﺎﻟﻨﺴﺒﺔ ﻵﻻﺕ ﺧﻠﻂ ﺍﻟﻮﺯﻥ ﺍﻟﺘﺮﺍﻛﻤﻲ‪ ،‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻜﻤﻴﺔ‬ ‫‪.8‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺤﺒﻮﺳﺔ ﺑﺎﻟﻬﻮﺍء‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔﻣﻦ ﺍﻟﺮﻛﺎﻡ ﺗﺴﺎﻭﻱ ﺃﻭ ﺗﺰﻳﺪ ﻋﻦ ‪ %30‬ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ‪ ،‬ﻓﻴﺠﺐ‬
‫ﺃﻥﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻤﻮﺯﻭﻧﺔ ﺿﻤﻦ ‪ 1%6‬ﻣﻦ ﺍﻟﻜﺘﻠﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻋﻨﺪ ﻛﻞ‬ ‫‪8.1‬ﻣﺎ ﻟﻢ ﻳﻨﺺ ﻋﻠﻰ ﺧﻼﻑ ﺫﻟﻚ‪ ،‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺤﺒﻮﺳﺔ‬
‫ﻭﺯﻧﺔﻣﺘﺘﺎﻟﻴﺔ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻤﻄﻠﻮﺑﺔ ﺃﻗﻞ ﻣﻦ ‪ %30‬ﻣﻦ ﺳﻌﺔ‬ ‫ﺑﺎﻟﻬﻮﺍء‪،‬ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻳﺎﺕ ﺍﻟﻬﻮﺍء ﻓﻴﻬﺎﺍﻟﺠﺪﻭﻝ ‪1‬ﺳﻴﺘﻢ ﺗﻄﺒﻴﻘﻪ ﺑﻨﺎء ًﻋﻠﻰ‬
‫ﺍﻟﻤﻴﺰﺍﻥﻓﻴﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻤﻮﺯﻭﻧﺔ ﻓﻲ ﺣﺪﻭﺩﻫﺎ ‪ 0.3%6‬ﻣﻦ‬ ‫ﺣﺎﻟﺔﺍﻟﺘﻌﺮﺽ ﺍﻟﻤﻨﺼﻮﺹ ﻋﻠﻴﻬﺎ ﻓﻲ ﺃﻣﺮ ﺍﻟﺸﺮﺍء‪ .‬ﻳﺴُﻤﺢ ﺑﺘﻘﻠﻴﻞ ﻗﻴﻢ‬
‫ﺳﻌﺔﺍﻟﻤﻴﺰﺍﻥ ﻋﻨﺪ ﻛﻞ ﻋﻤﻠﻴﺔ ﻭﺯﻥ ﻣﺘﺘﺎﻟﻴﺔ‪.‬‬ ‫ﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء ﺍﻹﺟﻤﺎﻟﻲ ﻓﻴﻬﺎﺍﻟﺠﺪﻭﻝ ‪1‬ﺑﻤﻘﺪﺍﺭ ﻧﻘﻄﺔ ﻣﺉﻮﻳﺔ ﻭﺍﺣﺪﺓ‬
‫ﻟﻠﺨﺮﺳﺎﻧﺔﺫﺍﺕ ﻗﻮﺓ ﺿﻐﻂ ﻣﺤﺪﺩﺓ ﺃﻛﺒﺮ ﻣﻦ ﺃﻭ ﺗﺴﺎﻭﻱ ‪ 35‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‬
‫‪5000‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‪ .‬ﺇﺟﻤﺎﻟﻲ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﺍﻟﺬﻱ ﻳﺨﺘﻠﻒ ﻋﻦ‬
‫ﻥ‪—13OTE‬ﻳﺤﺪﺩ ﺣﺪ ﺩﻗﺔ ﺍﻟﺨﻠﻂ ﺍﻟﺒﺎﻟﻎ ‪ %0.3‬ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ ﺣﺪﺍً ﺃﺩﻧﻰ ﻣﻌﻘﻮﻻً‬ ‫ﺍﻟﻘﻴﻢﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻴﻪﺍﻟﺠﺪﻭﻝ ‪1‬ﻳﺴﻤﺢ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻻ ﺗﺘﻌﺮﺽ ﻟﺪﻭﺭﺍﺕ‬
‫ﻟﺘﺤﻤﻞﺍﻟﻮﺯﻥ ﺑﺸﻜﻞ ﻣﺴﺘﻘﻞ ﻋﻦ ﻛﻤﻴﺔ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺘﻲ ﻳﺘﻢ ﻭﺯﻧﻬﺎ‪.‬‬
‫ﺍﻟﺘﺠﻤﻴﺪﻭﺍﻟﺬﻭﺑﺎﻥ )ﻣﻼﺣﻈﺔ ‪.(6‬‬

‫‪3.9‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻜﻮﻥ ﻣﺎء ﺍﻟﺨﻠﻂ ﻣﻦ ﻣﺎء ﺍﻟﺪﻓﻌﺔ )ﺍﻟﻤﺎء ﺍﻟﺬﻱ ﻳﺘﻢ ﻭﺯﻧﻪ‬
‫ﺃﻭﻗﻴﺎﺳﻪ ﻓﻲ ﺍﻟﻤﺼﻨﻊ(‪ ،‬ﻭﺍﻟﺜﻠﺞ‪ ،‬ﻭﺍﻟﺮﻃﻮﺑﺔ ﺍﻟﺤﺮﺓ ﻋﻠﻰ ﺍﻟﺮﻛﺎﻡ‪ ،‬ﻭﻣﺎء‬ ‫‪8.2‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺤﺒﻮﺳﺔ ﺑﺎﻟﻬﻮﺍء ﻋﻨﺪ‬
‫ﺍﻟﻐﺴﻴﻞﺍﻟﻤﺤﺘﺠﺰ ﻓﻲ ﺍﻟﺨﻼﻁ ﻗﺒﻞ ﺍﻟﺨﻠﻂ‪ ،‬ﻭﺍﻟﻤﺎء ﺍﻟﻤﻀﺎﻑ ﻓﻲ ﻣﻮﻗﻊ‬ ‫ﺃﺧﺬﺍﻟﻌﻴﻨﺎﺕ ﻣﻦ ﻭﺣﺪﺓ ﺍﻟﻨﻘﻞ ﻋﻨﺪ ﻧﻘﻄﺔ ﺍﻟﺘﻔﺮﻳﻎ ﺿﻤﻦ ﻧﻄﺎﻕ ﺍﻟﺘﺴﺎﻣﺢ‪6‬‬
‫ﺍﻟﻌﻤﻞﻭﻓﻘﺎً ﻟـ‪12.7‬ﺃﻭ ﻋﻦ ﻃﺮﻳﻖ ﻧﻈﺎﻡ ﺧﻠﻂ ﺍﻟﺸﺎﺣﻨﺎﺕ ﺍﻵﻟﻲ ﻭﻓﻘﺎً ﻟـ‪12.8‬‬ ‫‪1.5‬ﻣﻦ ﺍﻟﻘﻴﻤﺔ ﺍﻟﻤﺤﺪﺩﺓ‪.‬‬
‫ﻭﺍﻟﻤﺎءﺍﻟﻤﻀﺎﻑ ﻣﻦ ﺍﻟﻤﺨﺎﻟﻴﻂ ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﻀﺎﻓﺔ ﺗﺰﻳﺪ ﻧﺴﺒﺔ‬ ‫‪8.3‬ﻋﻨﺪ ﺃﺧﺬ ﻋﻴﻨﺔ ﺃﻭﻟﻴﺔ ﺧﻼﻝ ﺍﻟﺤﺪﻭﺩ ﺍﻟﺰﻣﻨﻴﺔ‪12.7‬ﻭﻗﺒﻞ ﺍﻟﺘﻔﺮﻳﻎ‬
‫ﺍﻟﻤﺎءﺇﻟﻰ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺑﺄﻛﺜﺮ ﻣﻦ ‪) 0.01‬ﻣﻼﺣﻈﺔ ‪ .(14‬ﻳﺠﺐ ﻗﻴﺎﺱ‬ ‫ﻟﻮﺿﻌﻪﻳﻈﻬﺮ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﺃﻗﻞ ﻣﻦ ﺍﻟﻤﺴﺘﻮﻯ ﺍﻟﻤﺤﺪﺩ ﺑﺄﻛﺜﺮ ﻣﻦ‬
‫ﺍﻟﻤﺎءﺍﻟﺪﻓﻌﻲ ﺑﺎﻟﻜﺘﻠﺔ ﺃﻭ ﺍﻟﺤﺠﻢ ﺑﺪﻗﺔ‪ 1%6‬ﻣﻦ ﻣﺎء ﺍﻟﺨﻠﻂ ﺍﻟﻤﻘﺮﺭ ﺑﻨﺴﺐ‬ ‫ﺍﻟﺘﺴﺎﻣﺢﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﻭﻓﻘﺎ‪ ،8.2‬ﻗﺪ ﺗﺴﺘﺨﺪﻡ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺧﻠﻴﻄﺎً‬
‫ﺍﻟﺨﻠﻄﺔﺍﻟﻤﺼﻤﻤﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻘﺎﺱ ﺍﻟﺠﻠﻴﺪ ﺑﺎﻟﻜﺘﻠﺔ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺧﻼﻃﺎﺕ‬ ‫ﺇﺿﺎﻓﻴﺎًﻟﺤﺒﺲ ﺍﻟﻬﻮﺍء ﻟﺘﺤﻘﻴﻖ ﻣﺴﺘﻮﻯ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﺍﻟﻤﻄﻠﻮﺏ‪ ،‬ﻳﻠﻴﻪ ﻣﺎ‬
‫ﺍﻟﺸﺎﺣﻨﺎﺕ‪،‬ﻳﺠﺐ ﻗﻴﺎﺱ ﺃﻱ ﻣﻴﺎﻩ ﻏﺴﻴﻞ ﻣﺤﺘﻔﻆ ﺑﻬﺎ ﻓﻲ ﺍﻟﺒﺮﻣﻴﻞ‬ ‫ﻻﻳﻘﻞ ﻋﻦ ‪ 30‬ﺩﻭﺭﺓ ﻓﻲ ﺳﺮﻋﺔ ﺍﻟﺨﻠﻂ‪ ،‬ﻃﺎﻟﻤﺎ ﺃﻥ ﺣﺪ ﺍﻟﺜﻮﺭﺓ ﻫﻮ‪6.1.9‬ﻟﻢ‬
‫ﻻﺳﺘﺨﺪﺍﻣﻬﺎﻓﻲ ﺍﻟﺪﻓﻌﺔ ﺍﻟﺘﺎﻟﻴﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ؛ ﺇﺫﺍ ﺛﺒﺖ ﺃﻥ ﺫﻟﻚ ﻏﻴﺮ‬ ‫ﻳﺘﻢﺗﺠﺎﻭﺯﻩ )ﺍﻧﻈﺮﻣﻼﺣﻈﺔ ‪.(11‬‬
‫ﻋﻤﻠﻲﺃﻭ ﻣﺴﺘﺤﻴﻞ‪ ،‬ﻓﻴﺠﺐ ﺗﺼﺮﻳﻒ ﻣﻴﺎﻩ ﺍﻟﻐﺴﻴﻞ ﻗﺒﻞ ﺗﺤﻤﻴﻞ ﺍﻟﺪﻓﻌﺔ‬
‫ﺍﻟﺘﺎﻟﻴﺔﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﻣﺎء ﺍﻟﺨﻠﻂ ﺩﻗﻴﻘﺔ ﻟﻠﺪﺍﺧﻞ ‪%6‬‬
‫‪3‬ﻣﻦ ﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﻘﺮﺭﺓ ﺑﻨﺴﺐ ﺍﻟﺨﻠﻄﺔ ﺍﻟﻤﺼﻤﻤﺔ‪.‬‬ ‫ﻥ‪ -11OTE‬ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﺍﻟﻘﺒﻮﻝ ﻭﺍﺧﺘﺒﺎﺭﻫﺎ ﻃﺒﻘﺎ ًﻟﻠﻤﻤﺎﺭﺳﺔ ‪C172/C172M‬ﻭﻻ ﻳﻨﻔﻲ‬
‫ﻫﺬﺍﺍﻟﺤﻜﻢ‪ .‬ﻗﺪ ﺗﺆﺩﻱ ﺯﻳﺎﺩﺓ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﺇﻟﻰ ﺯﻳﺎﺩﺓ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ‪.‬‬

‫‪.9‬ﻣﻮﺍﺩ ﺍﻟﻘﻴﺎﺱ‬
‫‪9.1‬ﺑﺎﺳﺘﺜﻨﺎء ﻣﺎ ﻫﻮ ﻣﺴﻤﻮﺡ ﺑﻪ ﻋﻠﻰ ﻭﺟﻪ ﺍﻟﺘﺤﺪﻳﺪ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻘﺎﺱ‬
‫ﻥ‪ -14OTE‬ﻣﺎء ﺍﻟﺨﻠﻂ ﻫﻮ ﻣﺠﻤﻮﻉ ﻛﻤﻴﺔ ﺍﻟﻤﺎء ﻓﻲ ﺍﻟﺪﻓﻌﺔ ﻧﺎﻗﺺ ﺍﻟﻤﺎء ﺍﻟﺬﻱ ﺗﻤﺘﺼﻪ‬
‫ﺍﻟﻤﻮﺍﺩﺍﻷﺳﻤﻨﺘﻴﺔ ﺑﺎﻟﻜﺘﻠﺔ‪ .‬ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻮﺍﺩ ﺍﺳﻤﻨﺘﻴﺔ ﺗﻜﻤﻴﻠﻴﺔ ﻓﻲ‬
‫ﺍﻟﺮﻛﺎﻡ‪.‬ﻳﺴﺘﺨﺪﻡ ﻣﺎء ﺍﻟﺨﻠﻂ ﻟﺤﺴﺎﺏ ﻧﺴﺒﺔ ﺍﻟﻤﺎء ﺇﻟﻰ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ )ﺙ‪/‬ﺳﻢ(‪.‬‬
‫ﺍﻟﺨﻠﻄﺎﺕﺍﻟﺨﺮﺳﺎﻧﻴﺔ‪ ،‬ﻳﺴُﻤﺢ ﺑﻘﻴﺎﺱ ﺍﻟﻜﺘﻠﺔ ﺍﻟﺘﺮﺍﻛﻤﻴﺔ ﺑﺎﺳﺘﺨﺪﺍﻡ‬
‫ﺍﻷﺳﻤﻨﺖﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ‪ ،‬ﻭﻟﻜﻦ ﻓﻲ ﻗﺎﺩﻭﺱ ﺍﻟﺪﻓﻌﺔ ﻭﻋﻠﻰ ﻣﻘﻴﺎﺱ‬
‫‪4.9‬ﺗﻘﺎﺱ ﺍﻟﻤﻀﺎﻓﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ ﻓﻲ ﺻﻮﺭﺓ ﻣﺴﺤﻮﻕ ﺑﺎﻟﻜﺘﻠﺔ‪ .‬ﻳﺘﻢ‬
‫ﻣﻨﻔﺼﻞﻭﻣﺘﻤﻴﺰ ﻋﻦ ﺗﻠﻚ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﻤﻮﺍﺩ ﺍﻷﺧﺮﻯ‪ .‬ﻳﺠﺐ ﻗﻴﺎﺱ ﻛﺘﻠﺔ‬
‫ﺧﻠﻂﺍﻟﻤﻀﺎﻓﺎﺕ ﺍﻟﻜﻴﻤﻴﺎﺉﻴﺔ ﺍﻟﺴﺎﺉﻠﺔ ﺣﺴﺐ ﺍﻟﻜﺘﻠﺔ ﺃﻭ ﺍﻟﺤﺠﻢ‪ .‬ﻳﺠﺐ ﺃﻥ‬
‫ﺍﻷﺳﻤﻨﺖﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ ﻗﺒﻞ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﺘﻜﻤﻴﻠﻴﺔ‪ .‬ﻋﻨﺪﻣﺎ ﺗﺘﺠﺎﻭﺯ‬
‫ﻳﺘﻢﺧﻠﻂ ﺍﻟﻤﺨﺎﻟﻴﻂ ﺍﻟﻤﻘﺎﺳﺔ ﺑﺎﻟﻜﺘﻠﺔ ﺃﻭ ﺍﻟﺤﺠﻢ ﺑﺪﻗﺔ ﺗﺒﻠﻎ‪ 3%6‬ﻣﻦ‬
‫ﻛﻤﻴﺔﺍﻟﻤﺎﺩﺓ ﺍﻷﺳﻤﻨﺘﻴﺔ ‪ %30‬ﻣﻦ ﺍﻟﺴﻌﺔ ﺍﻟﻜﺎﻣﻠﺔ ﻟﻠﻤﻴﺰﺍﻥ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ‬
‫ﺇﺟﻤﺎﻟﻲﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﺃﻭ ﺯﺍﺉﺪ ﺃﻭ ﻧﺎﻗﺺ ﺍﻟﻜﻤﻴﺔ ﺃﻭ ﺍﻟﺠﺮﻋﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻟـ‬
‫ﺍﻟﻜﻤﻴﺔﺍﻟﻤﻘﺎﺳﺔ ﻟﻸﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ ﻓﻲ ﺣﺪﻭﺩ ‪6‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ‬
‫‪50‬ﻛﺠﻢ ]‪ 100‬ﺭﻃﻞ[ ﻣﻦ ﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ‪ ،‬ﺃﻳﻬﻤﺎ ﺃﻛﺒﺮ‪.‬‬
‫ﻧﺴﺒﺔ‪ %1‬ﻣﻦ ﺍﻟﻜﺘﻠﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻭﺍﻟﻜﻤﻴﺔ ﺍﻟﺘﺮﺍﻛﻤﻴﺔ ﺍﻟﻤﻘﺎﺳﺔ ﻟﻸﺳﻤﻨﺖ‬
‫ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻹﺿﺎﻓﻴﺔ ﺿﻤﻦ ﺣﺪﻭﺩ‪1%6‬‬
‫ﻣﻦﺍﻟﻜﺘﻠﺔ ﺍﻟﺘﺮﺍﻛﻤﻴﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻋﻨﺪ ﻛﻞ ﻭﺯﻥ ﻣﺘﻮﺳﻂ‪ .‬ﻟﻠﺪﻓﻌﺎﺕ ﺍﻟﺼﻐﻴﺮﺓ‬
‫ﻥ‪ -15OTE‬ﻳﻮﺻﻰ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﻮﺯﻋﺎﺕ ﺍﻟﺨﻠﻄﺎﺕ ﻣﻦ ﺍﻟﻨﻮﻉ ﺍﻟﻤﻴﻜﺎﻧﻴﻜﻲ ﺍﻟﻘﺎﺩﺭﺓ ﻋﻠﻰ‬ ‫ﺇﻟﻰﻣﺎ ﻻ ﻳﻘﻞ ﻋﻦ ‪ 1‬ﻡ‪ 1]3‬ﻳﺎﺭﺩﺓ‪ ،[3‬ﻳﺠﺐ ﺃﻻ ﺗﻘﻞ ﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﻘﺎﺳﺔ‬
‫ﺍﻟﺘﻌﺪﻳﻞﻟﺘﻐﻴﺮ ﺍﻟﺠﺮﻋﺔ ﻭﺍﻟﻤﻌﺎﻳﺮﺓ ﺍﻟﺒﺴﻴﻄﺔ‪.‬‬ ‫ﻟﻸﺳﻤﻨﺖﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ ﻭﺍﻟﻜﻤﻴﺔ ﺍﻟﺘﺮﺍﻛﻤﻴﺔ ﺍﻟﻤﻘﺎﺳﺔ ﻟﻸﺳﻤﻨﺖ‬
‫ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﺍﻟﺘﻜﻤﻴﻠﻴﺔ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻋﻦ‬
‫ﺍﻟﻜﻤﻴﺔﺍﻟﻤﻄﻠﻮﺑﺔ ﻭﻻ ﺗﺰﻳﺪ ﻋﻦ‬
‫‪.10‬ﻣﺼﻨﻊ ﺍﻟﺨﻠﻂ‬
‫‪10.1‬ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﺻﻨﺎﺩﻳﻖ ﺫﺍﺕ ﺣﺠﻴﺮﺍﺕ ﻣﻨﻔﺼﻠﺔ ﻛﺎﻓﻴﺔ ﻓﻲ ﻣﺤﻄﺔ‬
‫ﺍﻟﺨﻠﻂﻟﻠﻐﺮﺍﻣﺔ ﻭﻟﻜﻞ ﻣﺎ ﻫﻮ ﻣﻄﻠﻮﺏ‬

‫‪5‬‬
‫ﺃ‪C94/C94M - 17‬‬
‫ﺗﻔﻲﺷﻬﺎﺩﺓ ﻣﺼﻨﻊ ﺭﺍﺑﻄﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺑﻤﺘﻄﻠﺒﺎﺕ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.‬‬ ‫ﺣﺠﻢﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ‪ .‬ﻳﺠﺐ ﺗﺼﻤﻴﻢ ﻛﻞ ﺣﺠﺮﺓ ﺣﺎﻭﻳﺔ ﻭﺗﺸﻐﻴﻠﻬﺎ ﺑﺤﻴﺚ‬
‫ﻳﺘﻢﺗﻔﺮﻳﻐﻬﺎ ﺑﻜﻔﺎءﺓ ﻭﺣﺮﻳﺔ‪ ،‬ﻣﻊ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ ﺍﻟﻔﺼﻞ‪ ،‬ﻓﻲ ﻗﺎﺩﻭﺱ‬
‫ﺍﻟﻮﺯﻥ‪.‬ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﻭﺳﺎﺉﻞ ﺍﻟﺘﺤﻜﻢ ﺑﺤﻴﺚ ﻳﺘﻢ ﺇﻏﻼﻕ ﺍﻟﻤﺎﺩﺓ ﺑﺪﻗﺔ ﻋﻨﺪ‬
‫‪.11‬ﺍﻟﺨﻼﻃﺎﺕ ﻭﺍﻟﻤﻘﻠﺒﺎﺕ‬ ‫ﺍﻗﺘﺮﺍﺏﺍﻟﻜﻤﻴﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻓﻲ ﻗﺎﺩﻭﺱ ﺍﻟﻮﺯﻥ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﺼُﻨﻊ ﻗﻮﺍﺩﻳﺲ‬
‫‪11.1‬ﺗﺸﻤﻞ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ ﺃﻭ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ‪ .‬ﻳﺸﻤﻞ‬ ‫ﺍﻟﻮﺯﻥﺑﻄﺮﻳﻘﺔ ﺗﻤﻨﻊ ﺗﺮﺍﻛﻢ ﺍﻟﻤﻮﺍﺩ ﺍﻟﻔﺎﺭﻏﺔ ﻭﺗﻔﺮﻏﻬﺎ ﺑﺎﻟﻜﺎﻣﻞ‪.‬‬
‫ﺍﻟﻤﺤﺮﺿﻮﻥﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ ﺃﻭ ﻣﺤﺮﺿﻲ ﺍﻟﺸﺎﺣﻨﺎﺕ‪.‬‬
‫‪11.1.1‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ ﻣﺰﻭﺩﺓ ﺑﻠﻮﺣﺔ ﺃﻭ ﺻﻔﺎﺉﺢ‬
‫ﻣﻌﺪﻧﻴﺔﻳﺸُﺎﺭ ﺇﻟﻴﻬﺎ ﺑﻮﺿﻮﺡ ﺑﺴﺮﻋﺔ ﺧﻠﻂ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺃﻭ ﺍﻟﻤﺠﺎﺫﻳﻒ‪،‬‬
‫ﻭﺍﻟﺴﻌﺔﺍﻟﻘﺼﻮﻯ ﻣﻦ ﺣﻴﺚ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ‪ .‬ﻓﻲ ﺣﺎﻟﺔ‬ ‫‪10.2‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺃﺟﻬﺰﺓ ﺍﻹﺷﺎﺭﺓ ﻣﺮﺉﻴﺔ ﺑﺎﻟﻜﺎﻣﻞ ﻭﻗﺮﻳﺒﺔ ﺑﻤﺎ ﻳﻜﻔﻲ‬
‫ﺍﺳﺘﺨﺪﺍﻣﻬﺎﻟﻠﺨﻠﻂ ﺍﻟﻜﺎﻣﻞ ﻟﻠﺨﺮﺳﺎﻧﺔ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ‬ ‫ﻟﻴﺘﻤﻜﻦﺍﻟﻤﺸﻐﻞ ﻣﻦ ﻗﺮﺍءﺗﻬﺎ ﺑﺪﻗﺔ ﺃﺛﻨﺎء ﺷﺤﻦ ﺍﻟﻘﺎﺩﻭﺱ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻤﺘﻊ‬
‫ﻣﺠﻬﺰﺓﺑﺠﻬﺎﺯ ﺗﻮﻗﻴﺖ ﻣﻘﺒﻮﻝ ﻻ ﻳﺴﻤﺢ ﺑﺘﻔﺮﻳﻎ ﺍﻟﺪﻓﻌﺔ ﺇﻻ ﺑﻌﺪ ﺍﻧﻘﻀﺎء‬ ‫ﺍﻟﻤﺸﻐﻞﺑﺈﻣﻜﺎﻧﻴﺔ ﺍﻟﻮﺻﻮﻝ ﺑﺴﻬﻮﻟﺔ ﺇﻟﻰ ﺟﻤﻴﻊ ﺃﺩﻭﺍﺕ ﺍﻟﺘﺤﻜﻢ‪.‬‬
‫ﻭﻗﺖﺍﻟﺨﻠﻂ ﺍﻟﻤﺤﺪﺩ‪.‬‬
‫‪10.3‬ﺗﻌﺘﺒﺮ ﺍﻟﻤﻮﺍﺯﻳﻦ ﺩﻗﻴﻘﺔ ﺇﺫﺍ ﺗﻢ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺩﻗﺘﻬﺎ ﻣﻦ ﺧﻼﻝ ﺍﻟﺴﻌﺔ‬
‫‪11.1.2‬ﻳﺠﺐ ﺃﻥ ﻳﻌﻠﻖ ﻛﻞ ﺧﻼﻁ ﺃﻭ ﺧﻼﻁ ﺷﺎﺣﻨﺔ ﺑﻪ ﻓﻲ ﻣﻜﺎﻥ ﺑﺎﺭﺯ‬ ‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔﻋﺎﺩﺓ ًﻭﻓﻘﺎً ﻟﻤﺎ ﻳﻠﻲ‪ :‬ﺍﻟﺠﺪﻭﻝ ‪2‬ﻭﺍﻟﺤﻤﻞ ﺍﻟﻤﺸﺎﺭ ﺇﻟﻴﻪ ﺑﺎﻟﻨﺴﺒﺔ‬
‫ﻟﻮﺣﺔﺃﻭ ﺻﻔﺎﺉﺢ ﻣﻌﺪﻧﻴﺔ ﻳﺤُﺪﺩ ﻋﻠﻴﻬﺎ ﺑﻮﺿﻮﺡ ﺍﻟﺤﺠﻢ ﺍﻹﺟﻤﺎﻟﻲ‬ ‫ﺇﻟﻰﺣﻤﻞ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻤﻄﺒﻖ ﻣﻮﺟﻮﺩ ﻓﻲ ﺍﻟﺪﺍﺧﻞ ‪ 0.15%6‬ﻣﻦ ﺇﺟﻤﺎﻟﻲ‬
‫ﻟﻸﺳﻄﻮﺍﻧﺔ‪،‬ﻭﺳﻌﺔ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺃﻭ ﺍﻟﺤﺎﻭﻳﺔ ﻣﻦ ﺣﻴﺚ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ‬ ‫ﺳﻌﺔﺍﻟﻤﻴﺰﺍﻥ ﺃﻭ ‪ %0.4‬ﻣﻦ ﺻﺎﻓﻲ ﺍﻟﺤﻤﻞ ﺍﻟﻤﻄﺒﻖ‪ ،‬ﺃﻳﻬﻤﺎ ﺃﻛﺒﺮ‪ .‬ﻳﺠﺐ ﺃﻥ‬
‫ﺍﻟﻤﺨﺘﻠﻄﺔ‪،‬ﻭ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻭﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﺴﺮﻋﺎﺕ ﺍﻟﺨﻠﻂ ﻟﺪﻭﺭﺍﻥ‬ ‫ﻳﺘﻮﺍﻓﻖﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻟﻜﻤﻴﺔ ﻭﺗﺴﻠﺴﻞ ﺃﺣﻤﺎﻝ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻤﻄﺒﻘﺔ‬
‫ﺍﻷﺳﻄﻮﺍﻧﺔﺃﻭ ﺍﻟﺸﻔﺮﺍﺕ ﺃﻭ ﺍﻟﻤﺠﺎﺫﻳﻒ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﺨﺘﻠﻄﺔ‬ ‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔﻟﻠﺘﺤﻘﻖ ﻣﻦ ﻣﻮﺍﺯﻳﻦ ﺍﻟﻤﻮﺍﺩ ﻣﻊﺍﻟﺠﺪﻭﻝ ‪2‬ﻭﻣﻼﺣﻈﺎﺗﻪ‪.‬‬
‫ﺑﺎﻟﺸﺎﺣﻨﺎﺕﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ‪12.5‬ﺃﻭ ﻳﺘﻘﻠﺺ ﻣﺨﺘﻠﻄﺎً ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ‬
‫ﻓﻲ‬
‫‪10.4‬ﻳﺠﺐ ﺃﻥ ﺗﻈﻞ ﺟﻤﻴﻊ ﻧﻘﺎﻁ ﺍﻻﺭﺗﻜﺎﺯ ﻭﺍﻟﺸﻘﻮﻕ ﻭﺃﺟﺰﺍء ﺍﻟﻌﻤﻞ‬
‫‪12.4‬ﻳﺠﺐ ﺃﻻ ﻳﺘﺠﺎﻭﺯ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ ‪ %63‬ﻣﻦ ﺍﻟﺤﺠﻢ‬
‫ﺍﻟﻤﻤﺎﺛﻠﺔﻧﻈﻴﻔﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﻤﻮﺍﺯﻳﻦ ﺫﺍﺕ ﺍﻟﻌﻮﺍﺭﺽ ﻣﺠﻬﺰﺓ ﺑﻤﺆﺷﺮ‬
‫ﺍﻹﺟﻤﺎﻟﻲﻟﻠﻄﺒﻞ ﺃﻭ ﺍﻟﺤﺎﻭﻳﺔ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﺮﻛﺰﻳﺔ ﺍﻟﺨﻠﻂ ﻛﻤﺎ ﻫﻮ‬
‫ﺗﻮﺍﺯﻥﺣﺴﺎﺱ ﺑﺪﺭﺟﺔ ﻛﺎﻓﻴﺔ ﻹﻇﻬﺎﺭ ﺍﻟﺤﺮﻛﺔ ﻋﻨﺪ ﻭﺿﻊ ﻭﺯﻥ ﻳﺴﺎﻭﻱ ‪%0.1‬‬
‫ﻣﻮﺿﺢﻓﻲ‪12.3‬ﻳﺠﺐ ﺃﻻ ﻳﺘﺠﺎﻭﺯ ﺣﺠﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺍﻟﺨﻼﻃﺔ ﺃﻭ ﺍﻟﻤﺤﺮﺽ‬
‫ﻣﻦﺍﻟﺴﻌﺔ ﺍﻻﺳﻤﻴﺔ ﻟﻠﻤﻴﺰﺍﻥ ﻓﻲ ﻗﺎﺩﻭﺱ ﺍﻟﺪﻓﻌﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺗﺤﺮﻙ‬
‫‪ %80‬ﻣﻦ ﺍﻟﺤﺠﻢ ﺍﻹﺟﻤﺎﻟﻲ ﻟﻸﺳﻄﻮﺍﻧﺔ ﺃﻭ ﺍﻟﺤﺎﻭﻳﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ‬
‫ﺍﻟﻤﺆﺷﺮ‪ %5‬ﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﺍﻟﺴﻌﺔ ﺍﻟﻤﻘﺪﺭﺓ ﺍﻟﺼﺎﻓﻴﺔ ﻷﻛﺒﺮ ﻋﺎﺭﺿﺔ ﻭﺯﻥ‬
‫ﺍﻟﺨﻼﻃﺎﺕﻭﺍﻟﻤﻘﻠﺒﺎﺕ ﻓﻲ ﺍﻟﺸﺎﺣﻨﺎﺕ ﻣﺠﻬﺰﺓ ﺑﻮﺳﺎﺉﻞ ﻟﻠﺘﺤﻘﻖ ﺑﺴﻬﻮﻟﺔ‬
‫ﻟﻨﻘﺺﺍﻟﻮﺯﻥ ﻭ‪ %4‬ﻟﻠﻮﺯﻥ ﺍﻟﺰﺍﺉﺪ‪.‬‬
‫ﻣﻦﻋﺪﺩ ﺩﻭﺭﺍﺕ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺃﻭ ﺍﻟﺸﻔﺮﺍﺕ ﺃﻭ ﺍﻟﻤﺠﺎﺫﻳﻒ‪.‬‬

‫‪11.2‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ ﻭﺍﻟﺸﺎﺣﻨﺎﺕ ﻗﺎﺩﺭﺓ ﻋﻠﻰ ﺇﻧﺘﺎﺝ‬ ‫‪5.10‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺟﻬﺎﺯ ﻗﻴﺎﺱ ﺍﻟﻤﺎء ﺍﻟﻤﻀﺎﻑ ﻗﺎﺩﺭﺍ ًﻋﻠﻰ ﺇﻳﺼﺎﻝ‬
‫ﺧﺮﺳﺎﻧﺔﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ ﺧﻼﻝ ﺍﻟﻮﻗﺖ ﺍﻟﻤﺤﺪﺩ‬ ‫ﺍﻟﻜﻤﻴﺔﺍﻟﻤﻄﻠﻮﺑﺔ ﻟﻠﺪﻓﻌﺔ ﺑﺎﻟﺪﻗﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻓﻲ‪ .9.3‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺗﺮﺗﻴﺐ‬
‫‪12.3‬ﺃﻭ ﺍﻟﻌﺪﺩ ﺍﻟﻤﺤﺪﺩ ﻣﻦ ﺍﻟﺜﻮﺭﺍﺕ ﻓﻲ‪ .12.5‬ﻳﺠﺐ ﺗﺤﺪﻳﺪ ﺍﻟﻘﺪﺭﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺠﻬﺎﺯﺑﺤﻴﺚ ﻻ ﺗﺘﺄﺛﺮ ﺍﻟﻘﻴﺎﺳﺎﺕ ﺑﺎﻟﻀﻐﻮﻁ ﺍﻟﻤﺘﻐﻴﺮﺓ ﻓﻲ ﺧﻂ ﺇﻣﺪﺍﺩ‬
‫ﺇﻧﺘﺎﺝﻭﺗﻔﺮﻳﻎ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﻠﻮﻃﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ ﻭﻓﻘﺎ ًﻟﻤﺎ ﻳﻠﻲ‪:‬ﺍﻟﻤﻠﺤﻖ ﺃ‪،1‬‬ ‫ﺍﻟﻤﻴﺎﻩ‪.‬ﻳﺠﺐ ﺃﻥ ﺗﺠﻬﺰ ﺧﺰﺍﻧﺎﺕ ﺍﻟﻘﻴﺎﺱ ﺑﺼﻨﺎﺑﻴﺮ ﻭﺻﻤﺎﻣﺎﺕ ﺧﺎﺭﺟﻴﺔ‬
‫ﺇﺫﺍﻟﺰﻡ ﺍﻷﻣﺮ‪.‬‬ ‫ﻟﻔﺤﺺﻣﻌﺎﻳﺮﺗﻬﺎ ﻣﺎ ﻟﻢ ﻳﺘﻢ ﺗﻮﻓﻴﺮ ﻭﺳﺎﺉﻞ ﺃﺧﺮﻯ ﻟﺘﺤﺪﻳﺪ ﻛﻤﻴﺔ ﺍﻟﻤﺎء ﻓﻲ‬
‫ﻥ‪ -17OTE‬ﺳﻴﻜﻮﻥ ﻟﺘﺴﻠﺴﻞ ﺃﻭ ﻃﺮﻳﻘﺔ ﺷﺤﻦ ﺍﻟﺨﻼﻁ ﺗﺄﺛﻴﺮ ﻣﻬﻢ ﻋﻠﻰ ﺗﺠﺎﻧﺲ‬ ‫ﺍﻟﺨﺰﺍﻥﺑﺴﻬﻮﻟﺔ ﻭﺩﻗﺔ‪.‬‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬

‫‪11.3‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﻟﻤﺤﺮﺽ ﻗﺎﺩﺭﺍ ًﻋﻠﻰ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﺍﻟﺨﺮﺳﺎﻧﺔ‬


‫ﺍﻟﻤﺨﺘﻠﻄﺔﻓﻲ ﺣﺎﻟﺔ ﺧﻠﻂ ﻣﻮﺣﺪﺓ‪ .‬ﺍﻟﻘﺪﺭﺓ ﻋﻠﻰ‬ ‫ﻥ‪—16OTE‬ﺣﺪﻭﺩ ﺩﻗﺔ ﺍﻟﻤﻘﻴﺎﺱ ﻟﻠﺨﻠﻄﺔ ﺍﻟﻮﻃﻨﻴﺔ ﺍﻟﺠﺎﻫﺰﺓ‬

‫ﺍﻻﺧﺘﺒﺎﺭﺃ‬ ‫ﺍﻟﺠﺪﻭﻝ‪ :2‬ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻭﺃﺣﻤﺎﻝ‬


‫ﺍﻟﺤﺪﺍﻷﺩﻧﻰ‬
‫)ﻣﻦ ﺣﻴﺚ ﺳﻌﺔ ﺍﻟﺠﻬﺎﺯ(‬
‫ﺍﻟﺤﺪﺍﻷﺩﻧﻰ ﻣﻦ ﺍﻷﺣﻤﺎﻝ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺩﻗﺔ ﺍﻟﻤﻘﻴﺎﺱ‬ ‫ﺳﻌﺔﺍﻟﺠﻬﺎﺯ‬
‫ﺍﻟﻤﻌﻴﺎﺭﺍﻟﻤﻴﺪﺍﻧﻲ‬
‫ﺃﺣﻤﺎﻝﺍﻻﺧﺘﺒﺎﺭﺝ‬
‫ﺍﻷﻭﺯﺍﻥ‬
‫‪0‬ﺇﻟﻰ ‪ 2000‬ﻛﺠﻢ‬
‫‪100%‬‬ ‫‪100%‬‬
‫]‪ 0‬ﺇﻟﻰ ‪ 4000‬ﺭﻃﻞ[‬

‫ﺍﻷﻭﺯﺍﻥﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﺃﻭ ﺍﻟﺤﻤﻞ ﺍﻻﺧﺘﺒﺎﺭﻱ ﻟﻠﺴﻌﺔ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ‪ ،‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺃﻛﺒﺮ ﻣﻦ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‬ ‫ﺃﻋﻈﻢﻣﻦﺏ‬ ‫‪2001‬ﺇﻟﻰ ‪ 20000‬ﻛﺠﻢ ]‬
‫ﺍﻟﻤﺤﺪﺩ‪.‬‬ ‫‪ 10%‬ﺃﻭ ‪ 500‬ﻛﺠﻢ‬ ‫‪4001‬ﺇﻟﻰ ‪ 40000‬ﺭﻃﻞ[‬
‫‪50%‬ﺩ‬ ‫]‪ 1000‬ﺭﻃﻞ[‬
‫ﺍﺧﺘﺒﺎﺭﺍﺕﺍﻟﺤﻤﻞ ﺍﻻﻧﻔﻌﺎﻟﻲﻩﻳﺴُﻤﺢ ﺑﺎﺳﺘﺨﺪﺍﻣﻬﺎ ﻓﻮﻕ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ ﺣﻤﻞ ﺍﻻﺧﺘﺒﺎﺭ‪ .‬ﺃﺛﻨﺎء ﺍﻟﺘﺤﻘﻖ ﺍﻷﻭﻟﻲ‪،‬‬
‫ﻳﺠﺐﺍﺧﺘﺒﺎﺭ ﺍﻟﻤﻴﺰﺍﻥ ﺣﺘﻰ ﻳﺼﻞ ﺇﻟﻰ ﻃﺎﻗﺘﻪ ﺍﻟﻜﺎﻣﻠﺔ‪.‬‬
‫ﺃﺇﺫﺍ ﻛﺎﻥ ﺗﻜﻮﻳﻦ ﻧﻈﺎﻡ ﺍﻟﻤﻴﺰﺍﻥ ﻭﺇﻋﺪﺍﺩﻩ ﻳﻤﻨﻊ ﺍﻟﻮﺻﻮﻝ ﺃﻭ ﺗﻄﺒﻴﻖ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﺍﻟﻜﺎﻓﻴﺔ ﺃﻭ ﺇﺫﺍ ﺗﻢ ﺇﻧﺸﺎء ﺣﺎﻟﺔ ﻏﻴﺮ ﺁﻣﻨﺔ ﻣﻦ ﺧﻼﻝ ﻋﻤﻠﻴﺔ ﺍﻟﺘﺤﻘﻖ‪ ،‬ﻓﻴﺠﺐ ﺍﻟﺘﻮﻗﻒ ﻋﻦ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻴﺰﺍﻥ ﻓﻮﻕ ﺍﻟﻤﻮﺿﻊ ﺍﻟﺬﻱ ﺗﻢ‬
‫ﺍﻟﺘﺤﻘﻖﻣﻨﻪ ﺣﺘﻰ ﻳﺘﻢ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺍﻹﺟﺮﺍءﺍﺕ ﺍﻟﺘﺼﺤﻴﺤﻴﺔ‪.‬‬
‫ﺏﻳﺠﺐ ﺃﻥ ﺗﺘﻮﺍﻓﻖ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻓﻲ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺩﻗﺔ ﺃﺟﻬﺰﺓ ﺍﻟﻮﺯﻥ ﻣﻊ ﻣﺘﻄﻠﺒﺎﺕ ﺩﻟﻴﻞ ‪.NIST 105-1‬‬
‫ﺝﻣﺼﻄﻠﺢ "ﺣﻤﻞ ﺍﻻﺧﺘﺒﺎﺭ" ﻳﻌﻨﻲ ﻣﺠﻤﻮﻉ ﻣﺠﻤﻮﻋﺔ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﻭﺃﻱ ﺣﻤﻞ ﻣﻄﺒﻖ ﺁﺧﺮ ﻳﺴﺘﺨﺪﻡ ﻓﻲ ﺇﺟﺮﺍء ﺍﻻﺧﺘﺒﺎﺭ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻃﺮﻕ ﺍﺧﺘﺒﺎﺭ ﺍﻻﺳﺘﺒﺪﺍﻝ‪ .‬ﺍﺧﺘﺒﺎﺭ ﺍﻻﺳﺘﺒﺪﺍﻝ ‪ -‬ﻓﻲ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺍﻻﺳﺘﺒﺪﺍﻝ‪ ،‬ﻳﺘﻢ‬
‫ﺍﺳﺘﺒﺪﺍﻝﺍﻟﻤﻮﺍﺩ ﺃﻭ ﺍﻟﻜﺎﺉﻨﺎﺕ ﺑﺎﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ‪ ،‬ﺃﻭ ﻣﺠﻤﻮﻋﺔ ﻣﻦ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﻭﺍﻟﻤﻮﺍﺩ ﺃﻭ ﺍﻟﻜﺎﺉﻨﺎﺕ ﺍﻟﻤﺤﺪﺩﺓ ﻣﺴﺒﻘﺎً‪ ،‬ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻘﻴﺎﺱ ﻗﻴﺪ ﺍﻻﺧﺘﺒﺎﺭ ﻛﻤﻘﺎﺭﻧﺔ‪ .‬ﻳﻤﻜﻦ ﺇﺿﺎﻓﺔ ﺃﻭﺯﺍﻥ ﺍﺧﺘﺒﺎﺭ ﺇﺿﺎﻓﻴﺔ‬
‫ﺃﻭﺃﺣﻤﺎﻝ ﺍﺧﺘﺒﺎﺭ ﻣﻌﺮﻭﻓﺔ ﺃﺧﺮﻯ ﺇﻟﻰ ﺣﻤﻞ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻤﻌﺮﻭﻑ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺩﻗﺔ ﻧﻄﺎﻗﺎﺕ ﺍﻟﻮﺯﻥ ﺍﻷﻋﻠﻰ ﻋﻠﻰ ﺍﻟﻤﻴﺰﺍﻥ‪.‬‬

‫ﺩﻳﺠﺐ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻤﻴﺰﺍﻥ ﻣﻦ ﺻﻔﺮ ﺇﻟﻰ ‪ %10‬ﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ‪ ،‬ﺛﻢ ﺇﻟﻰ ‪ %50‬ﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ ﺑﺎﺳﺘﺨﺪﺍﻡ ﺳﻠﺴﻠﺔ ﻣﻦ ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻷﺣﻤﺎﻝ ﺍﻟﺒﺪﻳﻠﺔ ﺍﻟﺘﻲ ﺗﺴﺘﺨﺪﻡ‬
‫ﺃﻭﺯﺍﻥﻗﻴﺎﺳﻴﺔ ﻣﻴﺪﺍﻧﻴﺔ ﺗﻌﺎﺩﻝ ‪ %10‬ﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ ‪.‬‬
‫ﻩﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺣﻤﻞ ﺍﻹﺟﻬﺎﺩ ﻟﻠﺘﺤﻘﻖ ﻣﻦ ﺍﻟﺪﻗﺔ ﻣﻦ ‪ %50‬ﻣﻦ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ ﺇﻟﻰ ﺍﻟﺴﻌﺔ ﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﻤﻴﺰﺍﻥ‪ .‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺣﻤﻞ ﻭﺍﺣﺪ ﻋﻠﻰ ﺍﻷﻗﻞ ﻓﻲ ﻛﻞ ﺭﺑﻊ ﺳﻌﺔ ﺍﻟﻤﻴﺰﺍﻥ‪ .‬ﺍﺧﺘﺒﺎﺭ ﺣﻤﻞ ﺍﻻﻧﻔﻌﺎﻝ ‪ -‬ﻓﻲ ﺇﺟﺮﺍء‬
‫ﺍﺧﺘﺒﺎﺭﺣﻤﻞ ﺍﻻﻧﻔﻌﺎﻝ‪ ،‬ﻳﺘﻢ ﺍﺳﺘﺨﺪﺍﻡ ﻛﻤﻴﺔ ﻏﻴﺮ ﻣﻌﺮﻭﻓﺔ ﻣﻦ ﺍﻟﻤﻮﺍﺩ ﺃﻭ ﺍﻷﺷﻴﺎء ﻹﻧﺸﺎء ﺣﻤﻞ ﻣﺮﺟﻌﻲ ﺃﻭ ﺍﻟﻔﺎﺭﻍ ﺍﻟﺬﻱ ﺗﻀﺎﻑ ﺇﻟﻴﻪ ﺍﻷﻭﺯﺍﻥ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﺃﻭ ﺃﺣﻤﺎﻝ ﺍﺧﺘﺒﺎﺭ ﺍﻻﺳﺘﺒﺪﺍﻝ‪.‬‬

‫‪6‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫‪12.3.2‬ﺇﺫﺍ ﺗﻢ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺃﺩﺍء ﺍﻟﺨﻼﻁ ﻭﻓﻘﺎً ﻟـﺍﻟﻤﻠﺤﻖ ﺃ‪ ،1‬ﻳﺴُﻤﺢ‬ ‫ﻳﺠﺐﺃﻥ ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﺻﻴﺎﻧﺔ ﻭﺗﻔﺮﻳﻎ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﻠﻮﻃﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ‬
‫ﺑﺘﺨﻔﻴﺾﻭﻗﺖ ﺍﻟﺨﻠﻂ ﺍﻟﻤﻘﺒﻮﻝ ﺇﻟﻰ ﺍﻟﻮﻗﺖ ﺍﻟﻤﺴﺎﻭ ٍﺃﻭ ﺍﻷﻛﺒﺮ ﻣﻦ ﺍﻟﻮﻗﺖ‬ ‫ﻭﻓﻘﺎ ًﻟﻤﺎ ﻳﻠﻲ‪:‬ﺍﻟﻤﻠﺤﻖ ﺃ‪ ،1‬ﺇﺫﺍ ﻟﺰﻡ ﺍﻷﻣﺮ‪.‬‬
‫ﺍﻟﻤﺴﺘﺨﺪﻡﻓﻲ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺘﺄﻫﻴﻞ‪ .‬ﺇﺫﺍ ﺗﻢ ﺗﻘﻠﻴﻞ ﻭﻗﺖ ﺍﻟﺨﻠﻂ ﺇﻟﻰ ﻫﺬﺍ ﺍﻟﺤﺪ‪،‬‬
‫‪11.4‬ﻳﻤﻜﻦ ﺍﺳﺘﺨﺪﺍﻡ ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﺮﻛﻮﺩ ﻟﻠﻌﻴﻨﺎﺕ ﺍﻟﻔﺮﺩﻳﺔ ﻟﺘﻮﻓﻴﺮ ﻓﺤﺺ‬
‫ﻓﻴﺠﺐﺃﻻ ﻳﺘﺠﺎﻭﺯ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻮﻗﺖ ﺍﻟﺨﻠﻂ ﻫﺬﺍ ﺍﻟﻮﻗﺖ ﺍﻟﻤﺨﻔﺾ ﺑﺄﻛﺜﺮ‬
‫ﺳﺮﻳﻊﻟﺪﺭﺟﺔ ﺍﻟﺘﺠﺎﻧﺲ ﺍﻟﻤﺤﺘﻤﻠﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ ﻭﺍﻻﺧﺘﺒﺎﺭ‬
‫ﻣﻦ‪ 60‬ﺛﺎﻧﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻬﻮﺍﺉﻴﺔ‪ .‬ﻳﺠﺐ ﺗﻜﺮﺍﺭ ﺍﺧﺘﺒﺎﺭﺍﺕ ﺃﺩﺍء ﺍﻟﺨﻼﻁ ﻋﻨﺪ‬
‫ﻭﻓﻘﺎﻝﺍﻟﻤﻠﺤﻖ ﺃ‪ .1‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻔﺮﻕ ﻓﻲ ﺍﻟﺮﻛﻮﺩ ﻳﺘﺠﺎﻭﺯ ﺍﻟﺤﺪﻭﺩ ﻓﻲﺍﻟﻤﻠﺤﻖ ﺃ‪1‬‬
‫ﻇﻬﻮﺭﺍﻟﺨﺮﺳﺎﻧﺔ ﺃﻭ ﻣﻘﺎﺭﻧﺔ ﻣﺤﺘﻮﻯ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﻟﻌﻴﻨﺎﺕ ﻣﻨﻔﺼﻠﺔ ﻛﻤﺎ‬
‫ﻻﻳﺠﻮﺯ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﺨﻼﻁ ﺃﻭ ﺍﻟﻤﺤﺮﺽ ﺇﻻ ﺑﻌﺪ ﺗﺼﺤﻴﺢ ﺍﻟﺤﺎﻟﺔ ﺑﺎﺳﺘﺜﻨﺎء ﻣﺎ‬
‫ﻫﻮﻣﻮﺿﺢ ﻓﻲﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﻳﺸﻴﺮ ﺇﻟﻰ ﺃﻧﻪ ﻟﻢ ﻳﺘﻢ ﺇﻧﺠﺎﺯ ﺍﻟﺨﻠﻂ ﺍﻟﻤﻨﺎﺳﺐ‪.‬‬
‫ﻫﻮﻣﻨﺼﻮﺹ ﻋﻠﻴﻪ ﻓﻲ‪.11.5‬‬

‫‪11.5‬ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻤﻄﺎﺑﻘﺔ ﻟﻠﻤﻮﺍﺻﻔﺎﺕ‪11.2‬ﻳﺴُﻤﺢ ﺑﻪ ﺇﺫﺍ‬


‫ﺗﻢﺗﺸﻐﻴﻠﻪ ﻣﻊ ﻭﻗﺖ ﺧﻠﻂ ﺃﻃﻮﻝ‪ ،‬ﺃﻭ ﺣﻤﻞ ﺃﺻﻐﺮ‪ ،‬ﺃﻭ ﺗﺴﻠﺴﻞ ﺷﺤﻦ ﺃﻛﺜﺮ‬
‫‪12.4‬ﺗﻘﻠﻴﺺ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ—ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ‬ ‫ﻛﻔﺎءﺓ‪.‬ﺇﺫﺍ ﻟﺰﻡ ﺍﻷﻣﺮ‪ ،‬ﻳﺠﺐ ﺗﻘﻴﻴﻢ ﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﻓﻘﺎ ﻝﺍﻟﻤﻠﺤﻖ ﺃ‪.1‬‬
‫ﻳﺘﻢﺧﻠﻄﻬﺎ ﺟﺰﺉﻴﺎ ًﺃﻭﻻ ًﻓﻲ ﺧﻼﻃﺔ ﺛﺎﺑﺘﺔ‪ ،‬ﻭﻣﻦ ﺛﻢ ﺧﻠﻄﻬﺎ ﺑﺎﻟﻜﺎﻣﻞ ﻓﻲ‬
‫ﺧﻼﻃﺔﺷﺎﺣﻨﺔ‪ ،‬ﻣﻄﺎﺑﻘﺔ ﻟﻤﺎ ﻳﻠﻲ‪ :‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺯﻣﻦ ﺍﻟﺨﻠﻂ ﺍﻟﺠﺰﺉﻲ ﻫﻮ‬
‫ﺃﻗﻞﻭﻗﺖ ﻣﻄﻠﻮﺏ ﻟﺨﻠﻂ ﺍﻟﻤﻜﻮﻧﺎﺕ‪ .‬ﺑﻌﺪ ﺍﻟﻨﻘﻞ ﺇﻟﻰ ﺧﻼﻁ ﺍﻟﺸﺎﺣﻨﺔ‪،‬‬
‫ﻳﺠﺐﺃﻥ ﺗﻜﻮﻥ ﻛﻤﻴﺔ ﺍﻟﺨﻠﻂ ﻋﻨﺪ ﺳﺮﻋﺔ ﺍﻟﺨﻠﻂ ﺍﻟﻤﺤﺪﺩﺓ ﺿﺮﻭﺭﻳﺔ ﻟﺘﻠﺒﻴﺔ‬ ‫‪11.6‬ﻳﺠﺐ ﻓﺤﺺ ﺍﻟﺨﻼﻃﺎﺕ ﻭﺍﻟﻤﺤﺮﺿﺎﺕ ﺃﻭ ﺗﺤﺪﻳﺪ ﻛﺘﻠﺘﻬﺎ ﺑﺸﻜﻞ‬
‫ﻣﺘﻄﻠﺒﺎﺕﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲﺍﻟﻤﻠﺤﻖ ﺃ‪ .1‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ‬ ‫ﻣﺘﻜﺮﺭﺣﺴﺐ ﺍﻟﻀﺮﻭﺭﺓ ﻟﻠﻜﺸﻒ ﻋﻦ ﺍﻟﺘﻐﻴﺮﺍﺕ ﻓﻲ ﺍﻟﺤﺎﻟﺔ ﺑﺴﺒﺐ‬
‫ﺍﻟﺪﻭﺭﺍﻥﺍﻹﺿﺎﻓﻲ ﻟﻠﺨﻼﻁ‪ ،‬ﺇﻥ ﻭﺟﺪ‪ ،‬ﺑﺴﺮﻋﺔ ﺗﻘﻠﻴﺐ ﻣﺤﺪﺩﺓ‪.‬‬ ‫ﺗﺮﺍﻛﻤﺎﺕﺍﻟﺨﺮﺳﺎﻧﺔ ﺃﻭ ﺍﻟﻤﻼﻁ ﺍﻟﻤﺘﺼﻠﺐ ﻭﻓﺤﺼﻬﺎ ﻟﻠﻜﺸﻒ ﻋﻦ ﺗﺂﻛﻞ‬
‫ﺍﻟﺸﻔﺮﺍﺕ‪.‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻫﺬﻩ ﺍﻟﺤﺎﻻﺕ ﺗﻌﺘﺒﺮ ﻭﺍﺳﻌﺔ ﺑﻤﺎ ﻳﻜﻔﻲ ﻟﻠﺘﺄﺛﻴﺮ ﻋﻠﻰ‬
‫ﺃﺩﺍءﺍﻟﺨﻼﻁ‪ ،‬ﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﻳﻀﻊ ﺍﻷﺳﺎﺱ ﻟﺘﺤﺪﻳﺪ ﻣﺎ ﺇﺫﺍ ﻛﺎﻥ ﺗﺼﺤﻴﺢ ﺃﻭﺟﻪ‬
‫ﺍﻟﻘﺼﻮﺭﻣﻄﻠﻮﺑﺎً ﺃﻭ ﻣﺎ ﺇﺫﺍ ﻛﺎﻥ ﺗﺼﺤﻴﺢ ﺃﻭﺟﻪ ﺍﻟﻘﺼﻮﺭ ﻛﺎﻓﻴﺎً‪.‬‬
‫‪12.5‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ ﺑﺎﻟﺸﺎﺣﻨﺎﺕ—ﻳﺠﺐ ﺃﻥ ﺗﻨﺘﺞ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ‬
‫ﻳﺘﻢﺧﻠﻄﻬﺎ ﺑﺎﻟﻜﺎﻣﻞ ﻓﻲ ﺧﻼﻁ ﺍﻟﺸﺎﺣﻨﺔ ﻟﻤﺪﺓ ‪ 70‬ﺇﻟﻰ ‪ 100‬ﺩﻭﺭﺓ ﺑﺴﺮﻋﺔ‬
‫ﺍﻟﺨﻠﻂﺍﻟﻤﺤﺪﺩﺓ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺧﺮﺳﺎﻧﺔ ﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ‬
‫ﻣﻮﺣﺪﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ ﻓﻲﺍﻟﻤﻠﺤﻖ ﺃ‪ .1‬ﺗﻜﻮﻥ ﺑﺪﺍﻳﺔ ﺍﻟﺨﻠﻂ ﺑﻌﺪ ﺗﺤﻤﻴﻞ ﺟﻤﻴﻊ‬ ‫‪.12‬ﺍﻟﺨﻠﻂ ﻭﺍﻟﺘﺴﻠﻴﻢ‬
‫ﺍﻟﻤﻮﺍﺩﻓﻲ ﺍﻟﺨﻼﻁ‪ .‬ﺇﺫﺍ ﺗﻢ ﺍﻹﺷﺎﺭﺓ ﺇﻟﻰ ﻣﺘﻄﻠﺒﺎﺕ ﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ‬
‫ﺍﻟﻤﻠﺤﻖﺃ‪1‬ﻻ ﻳﺘﻢ ﺍﺳﺘﻴﻔﺎء ‪ 100‬ﺩﻭﺭﺓ ﻣﻦ ﺍﻟﺨﻠﻂ ﻓﻼ ﻳﺠﻮﺯ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫‪12.1‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻭﺗﺴﻠﻴﻤﻬﺎ ﺇﻟﻰ ﺍﻟﻨﻘﻄﺔ ﺍﻟﺘﻲ ﻳﺤﺪﺩﻫﺎ‬
‫ﺍﻟﺨﻼﻁﺣﺘﻰ ﻳﺘﻢ ﺗﺼﺤﻴﺢ ﺍﻟﺤﺎﻟﺔ‪ ،‬ﺑﺎﺳﺘﺜﻨﺎء ﻣﺎ ﻫﻮ ﻣﻨﺼﻮﺹ ﻋﻠﻴﻪ ﻓﻲ‪11.5‬‬ ‫ﺍﻟﻤﺸﺘﺮﻱﻋﻦ ﻃﺮﻳﻖ ﺇﺣﺪﻯ ﻣﺠﻤﻮﻋﺎﺕ ﺍﻟﻌﻤﻠﻴﺎﺕ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬
‫‪.‬ﺇﺫﺍ ﺗﻢ ﺍﻟﻌﺜﻮﺭ ﻋﻠﻰ ﺃﺩﺍء ﻣﺮﺽ ٍﻓﻲ ﺧﻼﻃﺔ ﺷﺎﺣﻨﺔ ﻭﺍﺣﺪﺓ‪ ،‬ﻓﻴﻤﻜﻦ ﺍﻋﺘﺒﺎﺭ‬
‫ﺃﺩﺍءﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺘﻲ ﻟﻬﺎ ﻧﻔﺲ ﺍﻟﺘﺼﻤﻴﻢ ﻭﺣﺎﻟﺔ ﺍﻟﺸﻔﺮﺍﺕ ﻣﺮﺿﻴﺎً‪ .‬ﻳﺠﺐ‬ ‫‪12.1.1‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ‪.‬‬
‫ﺃﻥﺗﻜﻮﻥ ﺍﻟﺪﻭﺭﺍﺕ ﺍﻹﺿﺎﻓﻴﺔ ﻟﻠﺨﻼﻁ ﺍﻟﺘﻲ ﺗﺘﺠﺎﻭﺯ ﺍﻟﻌﺪﺩ ﺍﻟﻤﻮﺟﻮﺩ ﻹﻧﺘﺎﺝ‬ ‫‪12.1.2‬ﺗﻘﻠﻴﺺ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ‪.‬‬
‫ﺍﻟﺘﺠﺎﻧﺲﺍﻟﻤﻄﻠﻮﺏ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺑﺴﺮﻋﺔ ﺗﻘﻠﻴﺐ ﻣﺤﺪﺩﺓ‪.‬‬ ‫‪12.1.3‬ﺷﺎﺣﻨﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ‪.‬‬
‫‪12.2‬ﻳﺠﺐ ﺗﺸﻐﻴﻞ ﺍﻟﺨﻼﻃﺎﺕ ﻭﺍﻟﻤﻘﻠﺒﺎﺕ ﺿﻤﻦ ﺣﺪﻭﺩ ﺍﻟﻘﺪﺭﺓ ﻭﺳﺮﻋﺔ‬
‫ﺍﻟﺪﻭﺭﺍﻥﺍﻟﺘﻲ ﺗﺤﺪﺩﻫﺎ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻟﻠﻤﻌﺪﺍﺕ‪.‬‬

‫ﻥ‪ -19OTE‬ﺗﻢ ﺍﺧﺘﺒﺎﺭ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ ﺫﺍﺕ ﺍﻟﺘﺼﻤﻴﻢ ﺍﻟﻤﻤﺎﺛﻞ ﻭﺍﻟﺘﻲ ﺗﺤﻤﻞ ﻟﻮﺣﺔ‬
‫ﺗﻘﻴﻴﻢﺍﻷﺩﺍء ﺍﻟﺨﺎﺻﺔ ﺑﻤﻜﺘﺐ ﻣﺼﻨﻌﻲ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ ﻟﻘﺪﺭﺗﻬﺎ ﻋﻠﻰ ﺇﻧﺘﺎﺝ ﺧﺮﺳﺎﻧﺔ‬
‫‪12.3‬ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺮﻛﺰﻳﺔ ﺍﻟﻤﺨﺘﻠﻄﺔ—ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻳﺘﻢ ﺧﻠﻄﻬﺎ‬
‫ﻣﺨﺘﻠﻄﺔﺑﺸﻜﻞ ﻣﻮﺣﺪ ﻭﻓﻘﺎً ﻟـﺍﻟﻤﻠﺤﻖ ﺃ‪.1‬‬ ‫ﺑﺎﻟﻜﺎﻣﻞﻓﻲ ﺧﻼﻃﺔ ﺛﺎﺑﺘﺔ ﻭﺗﻨﻘﻞ ﺇﻟﻰ ﻧﻘﻄﺔ ﺍﻟﺘﺴﻠﻴﻢ ﺇﻣﺎ ﻓﻲ ﺷﺎﺣﻨﺔ ﺧﻠﻂ‪،‬‬
‫ﺃﻭﺧﻼﻃﺔ ﺷﺎﺣﻨﺔ ﺗﻌﻤﻞ ﺑﺴﺮﻋﺔ ﺍﻟﺨﻠﻂ‪ ،‬ﺃﻭ ﻓﻲ ﻣﻌﺪﺍﺕ ﻏﻴﺮ ﺧﻠﻂ ﻣﻌﺘﻤﺪﺓ‬
‫ﻣﻦﻗﺒﻞ ﺍﻟﻤﺸﺘﺮﻱ ﻭﺗﻠﺒﻲ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﺴﻢ‪13‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻣﻄﺎﺑﻘﺎ ًﻟﻤﺎ‬
‫‪12.6‬ﻋﻨﺪﻣﺎ ﻳﺘﻢ ﺍﺳﺘﺨﺪﺍﻡ ﺧﻼﻃﺔ ﺷﺎﺣﻨﺔ ﺃﻭ ﺷﺎﺣﻨﺔ ﺗﻘﻠﻴﺐ ﻟﻨﻘﻞ‬
‫ﻳﻠﻲ‪:‬ﻳﺘﻢ ﺣﺴﺎﺏ ﺯﻣﻦ ﺍﻟﺨﻠﻂ ﻣﻦ ﻭﻗﺖ ﻭﺟﻮﺩ ﺟﻤﻴﻊ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺼﻠﺒﺔ ﻓﻲ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﺘﻲ ﺗﻢ ﺧﻠﻄﻬﺎ ﺑﺎﻟﻜﺎﻣﻞ ﻓﻲ ﺧﻼﻃﺔ ﺛﺎﺑﺘﺔ‪ ،‬ﻓﺈﻥ ﺃﻱ ﺩﻭﺭﺍﻥ ﺃﺛﻨﺎء‬
‫ﺍﻟﺒﺮﻣﻴﻞ‪.‬ﻳﺠﺐ ﺗﺤﻤﻴﻞ ﺍﻟﺪﻓﻌﺔ ﻓﻲ ﺍﻟﺨﻼﻁ ﺑﺤﻴﺚ ﻳﺪﺧﻞ ﺑﻌﺾ ﺍﻟﻤﺎء ﻗﺒﻞ‬
‫ﺍﻟﻨﻘﻞﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺑﺎﻟﺴﺮﻋﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‬
‫ﺍﻷﺳﻤﻨﺖﻭﺍﻟﺮﻛﺎﻡ ﻭﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻣﻴﺎﻩ ﺍﻟﺪﻓﻌﺔ ﺍﻟﻤﺴﺘﻬﺪﻓﺔ ﻓﻲ‬
‫ﻟﻠﻤﻌﺪﺍﺕﻛﺴﺮﻋﺔ ﺗﻘﻠﻴﺐ‪.‬‬
‫ﺍﻷﺳﻄﻮﺍﻧﺔﺑﻨﻬﺎﻳﺔ ﺍﻟﺮﺑﻊ ﺍﻷﻭﻝ ﻣﻦ ﻭﻗﺖ ﺍﻟﺨﻠﻂ ﺍﻟﻤﺤﺪﺩ؛ ﺃﻭ ﻭﻓﻘﺎً ﻟﺘﺴﻠﺴﻞ‬
‫ﺍﻟﺸﺤﻦﺍﻟﻤﻮﺻﻰ ﺑﻪ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻟﺨﻼﻃﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫‪12.7‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﺴﻠﻴﻤﻬﺎ ﻓﻲ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ‪ ،‬ﻻ‬ ‫ﺍﻟﻤﺮﻛﺰﻳﺔ‪.‬‬
‫ﻳﺠﻮﺯﺇﺿﺎﻓﺔ ﺃﻱ ﻣﺎء ﻣﻦ ﻧﻈﺎﻡ ﻣﻴﺎﻩ ﺍﻟﺸﺎﺣﻨﺔ ﺃﻭ ﺃﻱ ﻣﻜﺎﻥ ﺁﺧﺮ ﺑﻌﺪ ﺍﻹﺩﺧﺎﻝ‬
‫ﺍﻷﻭﻟﻲﻟﻠﻤﻴﺎﻩ ﺃﺛﻨﺎء ﺍﻟﺨﻠﻂ‪ ،‬ﺑﺎﺳﺘﺜﻨﺎء ﻣﺎ ﻫﻮ ﻣﺴﻤﻮﺡ ﺑﻪ ﻓﻲ‪ ،12.8‬ﻭﺇﺫﺍ ﻛﺎﻥ‬
‫ﻣﻦﺍﻟﻀﺮﻭﺭﻱ ﺯﻳﺎﺩﺓ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﻋﻨﺪ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ‬
‫ﻟﻠﺘﻮﺍﻓﻖﻣﻊ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻨﺼﻮﺹ ﻋﻠﻴﻬﺎ ﻓﻲ ﺃﻣﺮ ﺍﻟﺸﺮﺍء‪ .‬ﻣﺎ ﻟﻢ ﻳﻨﺺ‬ ‫‪12.3.1‬ﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺃﺩﺍء ﺍﻟﺨﻼﻁ‪ ،‬ﻓﺈﻥ ﻭﻗﺖ ﺍﻟﺨﻠﻂ‬
‫ﻋﻠﻰﺧﻼﻑ ﺫﻟﻚ‪ ،‬ﺍﺣﺼﻞ ﻋﻠﻰ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺍﻟﻤﻄﻠﻮﺏ ﺿﻤﻦ‬ ‫ﺍﻟﻤﻘﺒﻮﻝﻟﻠﺨﻼﻃﺎﺕ ﺫﺍﺕ ﺍﻟﺴﻌﺎﺕ ‪ 0.76‬ﻡ‪ 1]3‬ﻳﺎﺭﺩﺓ‪ [3‬ﺃﻭ ﺃﻗﻞ ﻳﺠﺐ ﺃﻥ ﻻ‬
‫ﺍﻟﺘﻔﺎﻭﺗﺎﺕﺍﻟﻤﺴﻤﻮﺡ ﺑﻬﺎ ﺍﻟﻤﺬﻛﻮﺭﺓ ﻓﻲ‬ ‫ﺗﻘﻞﻋﻦ ‪ 1‬ﺩﻗﻴﻘﺔ‪ .‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺨﻼﻃﺎﺕ ﺫﺍﺕ ﺍﻟﺴﻌﺔ ﺍﻷﻛﺒﺮ‪ ،‬ﻳﺠﺐ ﺯﻳﺎﺩﺓ‬
‫‪ ،7.1.2,7.1.1‬ﺃﻭ‪7.1.3‬ﺑﺈﺿﺎﻓﺔ ﺍﻟﻤﺎء ﺃﻭ ﺍﻟﻤﺨﻠﻮﻁ ﺍﻟﻤﺨﻔﻒ ﻟﻠﻤﺎء ﺃﻭ‬ ‫ﻫﺬﺍﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﺑﻤﻘﺪﺍﺭ ‪ 15‬ﺛﺎﻧﻴﺔ ﻟﻜﻞ ﻣﺘﺮ ﻣﻜﻌﺐ ]ﻳﺎﺭﺩ ﻣﻜﻌﺐ[ ﺃﻭ ﺟﺰء‬
‫ﻛﻠﻴﻬﻤﺎ‪.‬ﻳﺠﺐ ﺃﻥ ﺗﺤﺪﺩ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻜﻤﻴﺔ ﺍﻟﻤﺎء ﺃﻭ‬ ‫ﻣﻨﻪﻣﻦ ﺍﻟﺴﻌﺔ ﺍﻹﺿﺎﻓﻴﺔ )ﺍﻧﻈﺮﺍﻟﻤﻼﺣﻈﺔ ‪.(18‬‬
‫ﺍﻟﻤﻀﺎﻓﺎﺕﺍﻟﻤﺨﻔﻀﺔ ﻟﻠﻤﺎء ﺍﻟﺘﻲ ﻳﻤﻜﻦ ﺇﺿﺎﻓﺘﻬﺎ ﻓﻲ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ ﻭﻳﺠﺐ‬
‫ﺃﻻﺗﺘﺠﺎﻭﺯ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻤﺤﺘﻮﻯ ﺍﻟﻤﺎء ﻟﻠﺪﻓﻌﺔ ﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ ﺑﻮﺍﺳﻄﺔ‬
‫ﻧﺴﺐﺍﻟﺨﻠﻴﻂ ﺍﻟﻤﺼﻤﻤﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺗﻌﺪﻳﻞ ﺍﻟﺨﻠﻄﺔ ﺍﻟﺨﺮﺳﺎﻧﻴﺔ ﺑﺎﻟﻤﺎء‬ ‫ﻥ‪—18OTE‬ﺗﻢ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ ﺫﺍﺕ ﺍﻟﺘﺼﻤﻴﻢ ﺍﻟﻤﻤﺎﺛﻞ ﻭﺍﻟﺘﻲ ﺗﺤﻤﻞ ﻟﻮﺣﺔ‬
‫ﺗﻘﻴﻴﻢﺍﻷﺩﺍء ﺍﻟﺨﺎﺻﺔ ﺑﻤﻜﺘﺐ ﻣﺼﻨﻌﻲ ﻣﺼﺎﻧﻊ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻟﻘﺪﺭﺗﻬﺎ ﻋﻠﻰ ﺇﻧﺘﺎﺝ ﺧﺮﺳﺎﻧﺔ‬
‫ﺃﻭﺍﻟﺨﻠﻄﺔ ﺍﻟﻤﺨﻔﻔﺔ ﻟﻠﻤﺎء ﻗﺒﻞ ﺗﺼﺮﻳﻒ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺇﻻ ﻋﻨﺪ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ‬ ‫ﻣﺨﺘﻠﻄﺔﺑﺸﻜﻞ ﻣﻮﺣﺪ ﻭﻓﻘﺎً ﻟـ ﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﻟﻠﻬﺒﻮﻁ ﺍﻟﻤﻨﺨﻔﺾ )>‪ 50‬ﻣﻢ ]‪ 2‬ﺑﻮﺻﺔ[(‬
‫ﻣﻮﺍﻓﻘﺔﺃﻭﻟﻴﺔ‬ ‫ﻭﺍﻟﻬﺒﻮﻁﺍﻟﻄﺒﻴﻌﻲ )‪ 150-100‬ﻣﻢ ]‪ 6-4‬ﺑﻮﺻﺔ[( ﻟﻠﺨﺮﺳﺎﻧﺔ ﻓﻲ ﻭﻗﺖ ﺧﻠﻂ ﻳﺘﺮﺍﻭﺡ ﺑﻴﻦ‬
‫‪30‬ﻭ‪ 90‬ﺛﺎﻧﻴﺔ‪.‬‬

‫‪7‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﻃﺎﻭﻟﺔ‪).‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﺸﺘﺮﻱ ﺇﺑﻼﻍ ﺍﻟﻤﻨﺘﺞ ﺑﻨﻮﻉ ﺍﻟﺒﻨﺎء ﺍﻟﻤﺨﺼﺺ‬ ‫ﻋﻴﻨﺔﻭﻓﻘﺎ ﻝ‪ .17.6‬ﻳﺠﺐ ﺣﻘﻦ ﺍﻟﻤﺎء ﺍﻹﺿﺎﻓﻲ ﻓﻲ ﺍﻟﺨﻼﻁ ﺗﺤﺖ ﺍﻟﻀﻐﻂ‬
‫ﻟﻠﺨﺮﺳﺎﻧﺔ‪(.‬‬ ‫ﻭﺍﺗﺠﺎﻩﺍﻟﺘﺪﻓﻖ ﻟﻠﺴﻤﺎﺡ ﺑﺎﻟﺘﻮﺯﻳﻊ ﺍﻟﻤﻨﺎﺳﺐ ﺩﺍﺧﻞ ﺍﻟﺨﻼﻁ‪ .‬ﺑﻌﺪ ﺍﻹﺿﺎﻓﺎﺕ‪،‬‬
‫ﺍﻟﺤﺪﺍﻷﺩﻧﻰ ﻟﺪﺭﺟﺔ ﺣﺮﺍﺭﺓ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻋﻨﺪ ﻭﺿﻌﻬﺎ‬ ‫ﻳﺠﺐﺃﻥ ﺗﺪﻭﺭ ﺍﻷﺳﻄﻮﺍﻧﺔ ‪ 30‬ﺩﻭﺭﺓ ﻋﻠﻰ ﺍﻷﻗﻞ ﺑﺴﺮﻋﺔ ﺍﻟﺨﻠﻂ‪ .‬ﻭﻳﺠﺐ‬
‫ﺗﺴﺠﻴﻞﻛﻤﻴﺔ ﺍﻟﻤﺎء ﺃﻭ ﺍﻟﻤﺨﻠﻮﻁ ﺍﻟﻤﺨﻔﺾ ﻟﻠﻤﺎء ﺍﻟﻤﻀﺎﻑ‪.‬‬
‫ﺩﺭﺟﺔﺍﻟﺤﺮﺍﺭﺓ‪ ،‬ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‪ ،‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ ]ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﻳﺖ[‬ ‫ﺣﺠﻢﺍﻟﻘﺴﻢ‪ ،‬ﻣﻢ ]ﺑﻮﺻﺔ[‬

‫‪[55]13‬‬ ‫>‪[12>] 300‬‬


‫‪[50]10‬‬ ‫‪[36–12] 900–300‬‬
‫‪[45]7‬‬ ‫‪[72–36] 1800–900‬‬ ‫‪12.8‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﺨﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ ﺍﻟﻤﺰﻭﺩﺓ ﺑﻘﻴﺎﺱ ﺁﻟﻲ ﻟﻠﻤﻴﺎﻩ ﺃﻭ‬
‫‪[40]5‬‬ ‫< ‪[72<] 1800‬‬ ‫ﺍﺧﺘﺰﺍﻝﺍﻟﻤﺎء ﻭﻣﻌﺪﺍﺕ ﻣﺮﺍﻗﺒﺔ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﺍﻟﻤﺤﺪﺩﺓ ﻓﻲ‪12.8.1‬‬
‫ﻳﺠﺐﺃﻻ ﺗﺘﺠﺎﻭﺯ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻘﺼﻮﻯ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻨﺘﺠﺔ ﺑﺎﻟﺮﻛﺎﻡ‬ ‫ﻭﺇﺫﺍﺳﻤﺢ ﺍﻟﻤﺸﺘﺮﻱ ﺑﺬﻟﻚ‪ ،‬ﻳﻤﻜﻦ ﺇﺿﺎﻓﺔ ﺍﻟﻤﺎء ﺃﻭ ﺍﻟﻤﺨﻠﻮﻁ ﺍﻟﻤﺨﻔﺾ‬
‫ﺍﻟﺴﺎﺧﻦﺃﻭ ﺍﻟﻤﺎء ﺍﻟﺴﺎﺧﻦ ﺃﻭ ﻛﻠﻴﻬﻤﺎ ﻓﻲ ﺃﻱ ﻭﻗﺖ ﺃﺛﻨﺎء ﺇﻧﺘﺎﺟﻬﺎ ﺃﻭ ﻧﻘﻠﻬﺎ‬ ‫ﻟﻠﻤﺎءﺃﻭ ﻛﻠﻴﻬﻤﺎ ﺃﺛﻨﺎء ﺍﻟﻨﻘﻞ ﺇﻟﻰ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ‪ .‬ﻭﻳﺠﺐ ﺣﻘﻦ ﻫﺬﺍ ﺍﻟﻤﺎء‬
‫‪32‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ ]‪ 90‬ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﻳﺖ(‪.‬‬ ‫ﺍﻹﺿﺎﻓﻲﻓﻲ ﺍﻟﺨﻼﻁ ﺗﺤﺖ ﻫﺬﺍ ﺍﻟﻀﻐﻂ ﻭﺍﺗﺠﺎﻩ ﺍﻟﺘﺪﻓﻖ ﻟﻠﺴﻤﺎﺡ ﺑﺎﻟﺘﻮﺯﻳﻊ‬
‫ﺍﻟﻤﻨﺎﺳﺐﺩﺍﺧﻞ ﺍﻟﺨﻼﻁ‪ .‬ﻳﺠﺐ ﺃﻻ ﻳﺘﺠﺎﻭﺯ ﺍﻟﻤﺤﺘﻮﻯ ﺍﻟﻤﺎﺉﻲ ﻟﻠﺪﻓﻌﺔ ﻣﺎ‬
‫ﻥ‪ -21OTE‬ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﺎء ﺍﻟﺴﺎﺧﻦ ﻗﺪ ﻳﺤﺪﺙ ﺗﺼﻠﺐ ﺳﺮﻳﻊ ﺇﺫﺍ ﺗﻢ ﻣﻼﻣﺴﺔ‬
‫ﺍﻟﻤﺎءﺍﻟﺴﺎﺧﻦ ﺑﺸﻜﻞ ﻣﺒﺎﺷﺮ ﻟﻸﺳﻤﻨﺖ‪ .‬ﺗﻮﺟﺪ ﻣﻌﻠﻮﻣﺎﺕ ﺇﺿﺎﻓﻴﺔ ﺣﻮﻝ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ‬ ‫ﺗﺤﺪﺩﻩﻧﺴﺐ ﺍﻟﺨﻠﻴﻂ ﺍﻟﻤﺼﻤﻤﺔ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﺇﺿﺎﻓﺔ ﺍﻟﻤﺎء ﺃﻭ ﺧﻠﻴﻂ ﻣﺨﻔﺾ‬
‫ﺍﻟﻄﻘﺲﺍﻟﺒﺎﺭﺩ ﻓﻲ ‪.ACI 306R‬‬ ‫ﻟﻠﻤﺎء‪،‬ﻳﺠﺐ ﺗﺪﻭﻳﺮ ﺍﻟﺨﻼﻁ ‪ 30‬ﺩﻭﺭﺓ ﻋﻠﻰ ﺍﻷﻗﻞ ﺑﺴﺮﻋﺔ ﺍﻟﺨﻠﻂ‪ .‬ﻭﻳﺠﺐ ﺃﻥ‬
‫‪12.12‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﻨﺘﺞ ﺗﺴﻠﻴﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﺃﺛﻨﺎء ﺍﻟﻄﻘﺲ‬ ‫ﻳﺘﻢﺍﻟﺨﻠﻂ ﺍﻟﻤﺬﻛﻮﺭ ﺑﻌﺪ ﺁﺧﺮ ﺇﺿﺎﻓﺔ ﻟﻠﻤﺎء ﺃﻭ ﻣﺨﻠﻮﻁ ﻣﺨﻔﺾ ﻟﻠﻤﺎء ﻭﻟﻜﻦ‬
‫ﺍﻟﺤﺎﺭﻋﻨﺪ ﺩﺭﺟﺎﺕ ﺣﺮﺍﺭﺓ ﻣﻨﺨﻔﻀﺔ ﻗﺪﺭ ﺍﻹﻣﻜﺎﻥ‪ ،‬ﺑﺸﺮﻁ ﻣﻮﺍﻓﻘﺔ ﺍﻟﻤﺸﺘﺮﻱ‪.‬‬ ‫ﻗﺒﻞﺑﺪء ﺍﻟﺘﺼﺮﻳﻒ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻗﺒﻮﻝ ﺃﻭ ﺭﻓﺾ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻋﻠﻰ ﺃﺳﺎﺱ‬
‫ﺍﻟﺮﻛﻮﺩﺃﻭ ﺍﻟﺠﺮﻳﺎﻥ ﺍﻟﻬﺎﺑﻂ ﻭﻓﻘﺎ ًﻟﻠﻘﺴﻢ‪.17‬‬

‫ﻥ‪ -22OTE‬ﻓﻲ ﺑﻌﺾ ﺍﻟﻤﻮﺍﻗﻒ ﻗﺪ ﺗﺘﻢ ﻣﻮﺍﺟﻬﺔ ﺍﻟﺼﻌﻮﺑﺔ ﻋﻨﺪﻣﺎ ﺗﻘﺘﺮﺏ ﺩﺭﺟﺎﺕ‬
‫ﺣﺮﺍﺭﺓﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﻦ ‪ 32‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ ]‪ 90‬ﺩﺭﺟﺔ ﻓﻬﺮﻧﻬﺎﻳﺖ(‪ .‬ﻳﻤﻜﻦ ﺍﻟﻌﺜﻮﺭ ﻋﻠﻰ‬
‫ﻣﻌﻠﻮﻣﺎﺕﺇﺿﺎﻓﻴﺔ ﻓﻲ ‪.ACI 305R‬‬

‫‪.13‬ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻤﺰﻋﺠﺔ‬ ‫‪12.8.1‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻣﻌﺪﺍﺕ ﻣﺮﺍﻗﺒﺔ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﺍﻵﻟﻲ ﻗﺎﺩﺭﺓ‬
‫ﻋﻠﻰﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻗﻴﺎﺱ ﻓﻴﺰﻳﺎﺉﻲ ﻭﺍﺣﺪ ﺃﻭ ﺃﻛﺜﺮ ﻋﻠﻰ ﺧﻼﻁ ﺍﻟﺸﺎﺣﻨﺔ‬
‫‪13.1‬ﺇﺫﺍ ﺗﻤﺖ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻰ ﺍﺳﺘﺨﺪﺍﻡ ﻣﻌﺪﺍﺕ ﺍﻟﻨﻘﻞ ﻏﻴﺮ ﺍﻟﻘﺎﺑﻠﺔ‬
‫ﻓﻴﻤﺎﻳﺘﻌﻠﻖ ﺑﻬﺒﻮﻁ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺃﻭ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﻭﺗﻮﻓﻴﺮ ﻣﺆﺷﺮ ﻋﻠﻰ ﺍﻟﺮﻛﻮﺩ ﺃﻭ‬
‫ﻟﻠﺘﺤﺮﻳﻚﻣﻦ ﻗﺒﻞ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻓﻴﺠﺐ ﺗﺼﻨﻴﻊ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ ﻣﺼﻨﻊ ﺧﻠﻂ‬
‫ﺍﻟﺘﺪﻓﻖﺍﻟﺮﻛﻮﺩ ﺑﻨﺎء ًﻋﻠﻰ ﺍﻻﺭﺗﺒﺎﻃﺎﺕ ﺍﻟﻤﺤﺪﺩﺓ ﻣﺴﺒﻘﺎً‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻘﻮﻡ‬
‫ﻣﺮﻛﺰﻱ‪.‬ﺗﻄﺒﻖ ﺍﻟﻘﻴﻮﺩ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬
‫ﻣﻌﺪﺍﺕﻗﻴﺎﺱ ﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﺑﺎﻹﺑﻼﻍ ﻣﻦ ﺣﻴﺚ ﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ‬
‫‪13.2‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺃﺟﺴﺎﻡ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻘﺎﺑﻠﺔ ﻟﻠﺘﺤﺮﻳﻚ ﻋﺒﺎﺭﺓ ﻋﻦ‬ ‫ﺃﻭﺍﻟﺮﻛﻮﺩ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺟﻬﺎﺯ ﻗﻴﺎﺱ ﺍﻟﻤﻴﺎﻩ ﺩﻗﻴﻘﺎً‪ 3%6‬ﻣﻦ ﺍﻟﻤﺒﻠﻎ‬
‫ﺣﺎﻭﻳﺎﺕﻣﻌﺪﻧﻴﺔ ﻧﺎﻋﻤﺔ ﻭﻣﺎﻧﻌﺔ ﻟﻠﻤﺎء ﻭﻣﺠﻬﺰﺓ ﺑﺒﻮﺍﺑﺎﺕ ﺗﺴﻤﺢ ﺑﺎﻟﺘﺤﻜﻢ ﻓﻲ‬ ‫ﺍﻟﻤﻀﺎﻑﻣﻊ ﺍﻟﺠﻬﺎﺯ ﺍﻟﻤﺬﻛﻮﺭ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺟﻬﺎﺯ ﻗﻴﺎﺱ ﺍﻟﻤﺨﻠﻮﻁ‬
‫ﺗﺼﺮﻳﻒﺍﻟﺨﺮﺳﺎﻧﺔ‪ .‬ﻳﺠﺐ ﺗﻮﻓﻴﺮ ﺍﻷﻏﻄﻴﺔ ﻟﻠﺤﻤﺎﻳﺔ ﻣﻦ ﺍﻟﻄﻘﺲ ﺇﺫﺍ ﻃﻠﺐ‬ ‫ﺍﻟﻤﺨﻔﺾﻟﻠﻤﺎء ﺩﻗﻴﻘﺎ ًﻷﻛﺒﺮ ﻣﻨﻬﺎ‪ 3%6‬ﻣﻦ ﺍﻟﻤﺒﻠﻎ ﺍﻟﻤﻀﺎﻑ ﺃﻭ‪ 306‬ﻣﻞ ]‪6‬‬
‫ﺍﻟﻤﺸﺘﺮﻱﺫﻟﻚ‪.‬‬ ‫‪1‬ﺃﻭﻧﺼﺔ ﺳﺎﺉﻠﺔ[‪ .‬ﺑﻨﺎء ﻋﻠﻰ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ‪ ،‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ‬
‫ﺍﻟﻤﺼﻨﻌﺔﺗﻘﺪﻳﻢ ﺑﻴﺎﻧﺎﺕ ﻻ ﻳﺰﻳﺪ ﻋﻤﺮﻫﺎ ﻋﻦ ‪ 6‬ﺃﺷﻬﺮ ﺗﺜﺒﺖ ﺩﻗﺔ ﺍﻷﺟﻬﺰﺓ‬
‫‪13.3‬ﻳﺠﺐ ﺗﺴﻠﻴﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺇﻟﻰ ﻣﻮﻗﻊ ﺍﻟﻌﻤﻞ ﺑﺪﺭﺟﺔ ﻣﺮﺿﻴﺔ ﻣﻦ‬ ‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔﻟﻘﻴﺎﺱ ﺍﻟﻤﺎء ﺃﻭ ﺧﻠﻴﻂ ﺗﻘﻠﻴﻞ ﺍﻟﻤﺎء‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﺤﺘﻮﻱ‬
‫ﺍﻟﺘﺠﺎﻧﺲ‪.‬ﻳﺘﻢ ﺗﻌﺮﻳﻒ ﺩﺭﺟﺔ ﻣﺮﺿﻴﺔ ﻣﻦ ﺍﻟﺘﻮﺣﻴﺪ ﻓﻲﺍﻟﻤﻠﺤﻖ ﺃ‪.1‬‬ ‫ﺍﻟﻤﻌﺪﺍﺕﻋﻠﻰ ﺿﻮﺍﺑﻂ ﻟﻤﻨﻊ ﺗﺼﺮﻳﻒ ﺍﻟﻤﻴﺎﻩ ﻋﻨﺪ ﺍﻟﺤﺪﻭﺩ ﺍﻟﻤﺤﺪﺩﺓ ﻣﺴﺒﻘﺎً‬
‫ﻟﺘﺠﻨﺐﺗﺠﺎﻭﺯ ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﻤﺤﺘﻮﻯ ﺍﻟﻤﺎء ﻟﻠﺪﻓﻌﺔ ﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ‬
‫ﺑﻮﺍﺳﻄﺔﻧﺴﺐ ﺍﻟﺨﻠﻴﻂ ﺍﻟﻤﺼﻤﻤﺔ‪.‬‬
‫‪13.4‬ﺗﻢ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﺮﻛﻮﺩ ﻟﻠﻌﻴﻨﺎﺕ ﺍﻟﻔﺮﺩﻳﺔ ﻭﺍﺧﺘﺒﺎﺭﻫﺎ‬
‫ﻭﻓﻘﺎًﻟـﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﻳﻤﻜﻦ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ ﻟﻠﺘﺤﻘﻖ ﺍﻟﺴﺮﻳﻊ ﻣﻦ ﺩﺭﺟﺔ ﺍﻟﺘﻮﺣﻴﺪ‬
‫ﺍﻟﻤﺤﺘﻤﻠﺔ‪.‬ﻓﺈﺫﺍ ﺍﺧﺘﻠﻔﺖ ﻫﺬﻩ ﺍﻟﻬﺒﻮﻃﺎﺕ ﺑﺄﻛﺜﺮ ﻣﻦ ﺍﻟﺤﺪﻭﺩ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻓﻴﻬﺎ‬
‫ﺍﻟﺠﺪﻭﻝﺃ‪ ،1.1‬ﻻ ﻳﺠﻮﺯ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻘﺎﺑﻠﺔ ﻟﻠﺘﺤﺮﻳﻚ ﺇﻻ ﺇﺫﺍ ﺗﻢ‬
‫ﺗﺼﺤﻴﺢﺍﻟﺸﺮﻭﻁ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﻤﻨﺼﻮﺹ ﻋﻠﻴﻪ ﻓﻲ‪.13.5‬‬ ‫‪12.9‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺍﻻﻧﺘﻬﺎء ﻣﻦ ﺗﻔﺮﻳﻎ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺧﻼﻝ ‪1‬‬
‫‪2⁄1‬ﺡ ﺑﻌﺪ ﺇﺩﺧﺎﻝ ﻣﺎء ﺍﻟﺨﻠﻂ ﺇﻟﻰ ﺍﻷﺳﻤﻨﺖ ﻭﺍﻟﺮﻛﺎﻡ ﺃﻭ ﺇﺩﺧﺎﻝ ﺍﻷﺳﻤﻨﺖ‬
‫‪13.5‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻣﺘﻄﻠﺒﺎﺕﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﻻ ﻳﺘﻢ ﺍﺳﺘﻴﻔﺎء ﻫﺬﻩ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ‬ ‫ﺇﻟﻰﺍﻟﺮﻛﺎﻡ‪ .‬ﻳﺠﻮﺯ ﻟﻠﻤﺸﺘﺮﻱ ﺍﻟﺘﻨﺎﺯﻝ ﻋﻦ ﻫﺬﺍ ﺍﻟﻘﻴﺪ ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﻋﻨﺪﺗﺸﻐﻴﻞ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻤﺘﺤﺮﻛﺔ ﻷﻗﺼﻰ ﻭﻗﺖ ﻟﻠﻨﻘﻞ‪ ،‬ﻭﻣﻊ ﺧﻠﻂ‬ ‫ﺗﻌﺎﻧﻲﻣﻦ ﻫﺬﺍ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﺍﻟﻤﻨﺨﻔﺾ ﺑﻌﺪ ‪-2⁄11‬ﺣﺎﻥ ﺍﻟﻮﻗﺖ ﺍﻟﺬﻱ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﻷﺩﻧﻰ ﺣﺪ ﻣﻦ ﺍﻟﻮﻗﺖ‪ ،‬ﻳﺠﺐ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻤﻌﺪﺍﺕ ﻓﻘﻂ ﻋﻨﺪ‬ ‫ﻳﻤﻜﻦﻓﻴﻪ ﻭﺿﻌﻪ ﺩﻭﻥ ﺇﺿﺎﻓﺔ ﺍﻟﻤﺎء ﺇﻟﻰ ﺍﻟﺪﻓﻌﺔ‪ .‬ﻓﻲ ﺍﻟﻄﻘﺲ ﺍﻟﺤﺎﺭ‪ ،‬ﺃﻭ‬
‫ﺗﺸﻐﻴﻠﻬﺎﺑﺎﺳﺘﺨﺪﺍﻡ ﻋﻤﻠﻴﺎﺕ ﻧﻘﻞ ﺃﻗﺼﺮ‪ ،‬ﺃﻭ ﺃﻭﻗﺎﺕ ﺧﻠﻂ ﺃﻃﻮﻝ‪ ،‬ﺃﻭ‬ ‫ﻓﻲﻇﻞ ﺍﻟﻈﺮﻭﻑ ﺍﻟﺘﻲ ﺗﺴﺎﻫﻢ ﻓﻲ ﺗﺼﻠﺐ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺑﺴﺮﻋﺔ‪ ،‬ﺯﻣﻦ ﺃﻗﻞ‬
‫ﻣﺠﻤﻮﻋﺎﺕﻣﻨﻬﺎ ﺗﺆﺩﻱ ﺇﻟﻰ ﻣﺘﻄﻠﺒﺎﺕﺍﻟﻤﻠﺤﻖ ﺃ‪1‬ﺍﻟﺬﻱ ﺗﻢ ﻟﻘﺎﺅﻩ‪.‬‬ ‫ﻣﻦ‪.2⁄11‬ﻣﺴﻤﻮﺡ ﻟﻠﻤﺸﺘﺮﻱ ﺑﺘﺤﺪﻳﺪﻩ ‪h‬‬

‫‪.14‬ﻣﻌﻠﻮﻣﺎﺕ ﺍﻟﺘﺬﻛﺮﺓ ﺍﻟﻤﺠﻤﻌﺔ‬ ‫‪12.10‬ﺇﺫﺍ ﻛﺎﻥ ﺣﺪ ﺛﻮﺭﺓ ﺍﻟﻄﺒﻞ )‪ (6.1.9‬ﻟﺒﺪء ﺍﻟﺘﻔﺮﻳﻎ ﺍﻟﻤﺤﺪﺩ ﻣﻦ ﻗﺒﻞ‬
‫‪14.1‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺃﻥ ﺗﺰﻭﺩ ﺍﻟﻤﺸﺘﺮﻱ ﻣﻊ‬ ‫ﺍﻟﻤﺸﺘﺮﻱ‪،‬ﻳﺠﺐ ﺃﻥ ﻳﺤﻜﻢ ﻫﺬﺍ ﺍﻟﺤﺪ‪.‬‬
‫ﻛﻞﺩﻓﻌﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻗﺒﻞ ﺍﻟﺘﻔﺮﻳﻎ ﻓﻲ ﺍﻟﻤﻮﻗﻊ‪ ،‬ﺑﺘﺬﻛﺮﺓ ﺗﺴﻠﻴﻢ ﺗﺤﺘﻮﻱ‬
‫ﻥ‪—20OTE‬ﺍﻋﺘﻤﺎﺩﺍً ﻋﻠﻰ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﺸﺮﻭﻉ‪ ،‬ﺗﺘﻮﻓﺮ ﺍﻟﺘﻜﻨﻮﻟﻮﺟﻴﺎ ﻟﻠﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ‬
‫ﻋﻠﻰﻣﻌﻠﻮﻣﺎﺕ ﺗﺘﻌﻠﻖ ﺑﺎﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺬﻛﻮﺭﺓ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﺘﺎﻟﻲ‪:‬‬ ‫ﻟﺘﻐﻴﻴﺮﺧﺼﺎﺉﺺ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ )ﻣﺜﻞ ﻭﻗﺖ ﺍﻹﻋﺪﺍﺩ‪ ،‬ﻭﺍﻟﺘﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺮﻛﻮﺩ‪،‬‬
‫ﻭﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء(‪ .‬ﻓﻲ ﺑﻌﺾ ﺍﻟﻤﺸﺎﺭﻳﻊ‪ ،‬ﻗﺪ ﺗﻄﻠﺐ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺇﺟﺮﺍء ﺗﻐﻴﻴﺮﺍﺕ‬
‫‪14.1.1‬ﺍﺳﻢ ﺷﺮﻛﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻭﻣﺼﻨﻊ ﺍﻟﺨﻠﻂ‪ ،‬ﺃﻭ ﺭﻗﻢ ﻣﺼﻨﻊ‬ ‫ﻋﻠﻰﺑﻌﺾ ﺧﺼﺎﺉﺺ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ ﺑﺴﺒﺐ ﺍﻟﻤﺴﺎﻓﺔ ﺃﻭ ﻭﻗﺖ ﺍﻟﻨﻘﻞ ﺍﻟﻤﺘﻮﻗﻊ ﺑﻴﻦ‬
‫ﺍﻟﺨﻠﻂ‪،‬‬ ‫ﻣﺼﻨﻊﺍﻟﺨﻠﻂ ﻭﻧﻘﻄﺔ ﺍﻟﺘﺴﻠﻴﻢ‪.‬‬
‫‪14.1.2‬ﺍﻟﺮﻗﻢ ﺍﻟﺘﺴﻠﺴﻠﻲ ﻟﻠﺘﺬﻛﺮﺓ‪،‬‬
‫‪14.1.3‬ﺍﻟﺘﺎﺭﻳﺦ‪،‬‬ ‫‪12.11‬ﻳﺠﺐ ﺃﻥ ﺗﺘﻤﺘﻊ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺘﻲ ﻳﺘﻢ ﺗﺴﻠﻴﻤﻬﺎ ﻓﻲ ﺍﻟﻄﻘﺲ‬
‫‪14.1.4‬ﺭﻗﻢ ﺍﻟﺸﺎﺣﻨﺔ‪،‬‬ ‫ﺍﻟﺒﺎﺭﺩﺑﺪﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﺪﻧﻴﺎ ﺍﻟﻤﻄﺒﻘﺔ ﻭﺍﻟﻤﻮﺿﺤﺔ ﻓﻴﻤﺎ ﻳﻠﻲ‬

‫‪8‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫‪16.1.4‬ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‪-‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪ ;C138/C138M‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‬ ‫‪14.1.5‬ﺍﺳﻢ ﺍﻟﻤﺸﺘﺮﻱ‪،‬‬


‫‪C173/C173M‬ﺃﻭ ﻃﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ‪.C231/C231M‬‬ ‫‪14.1.6‬ﺍﻟﺘﻌﻴﻴﻦ ﺍﻟﻤﺤﺪﺩ ﻟﻠﻮﻇﻴﻔﺔ )ﺍﻻﺳﻢ ﻭﺍﻟﻤﻮﻗﻊ(‪،‬‬
‫‪16.1.5‬ﺍﻟﺮﻛﻮﺩ —ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪.C143/C143M‬‬ ‫‪14.1.7‬ﻓﺉﺔ ﺃﻭ ﺗﺴﻤﻴﺔ ﻣﺤﺪﺩﺓ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺑﻤﺎ ﻳﺘﻮﺍﻓﻖ ﻣﻊ ﺗﻠﻚ‬
‫‪16.1.6‬ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ —ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪.C1611/C1611M‬‬ ‫ﺍﻟﻤﺴﺘﺨﺪﻣﺔﻓﻲ ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﻌﻤﻞ‪،‬‬
‫‪16.1.7‬ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ—ﻳﻤﺎﺭﺱ‪.C172/C172M‬‬ ‫‪14.1.8‬ﻛﻤﻴﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺑﺎﻟﺴﺎﺣﺎﺕ ﺍﻟﻤﻜﻌﺒﺔ )ﺃﻭ ﺍﻷﻣﺘﺎﺭ ﺍﻟﻤﻜﻌﺒﺔ(‪،‬‬
‫‪16.1.8‬ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ‪-‬ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪.C1064/C1064M‬‬ ‫‪14.1.9‬ﻭﻗﺖ ﺍﻟﺘﺤﻤﻴﻞ ﺃﻭ ﻭﻗﺖ ﺍﻟﺨﻠﻂ ﺍﻷﻭﻝ ﻟﻸﺳﻤﻨﺖ ﻭﺍﻟﺮﻛﺎﻡ‬
‫‪16.2‬ﻳﺠﺐ ﻋﻠﻰ ﻭﻛﺎﻟﺔ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﺘﻲ ﺗﺠﺮﻱ ﺍﺧﺘﺒﺎﺭﺍﺕ ﻗﺒﻮﻝ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺃﻥﺗﺴﺘﻮﻓﻲ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻤﺎﺭﺳﺔ‪.C1077‬‬ ‫‪14.1.10‬ﻛﻤﻴﺔ ﺍﻟﻤﻴﺎﻩ ﺍﻟﻤﻀﺎﻓﺔ ﺑﻨﺎء ﻋﻠﻰ ﻃﻠﺐ ﺍﻟﻤﺸﺘﺮﻱ ﺃﻭ ﻣﻤﺜﻞ‬
‫ﺍﻟﻤﺸﺘﺮﻱﺍﻟﻤﻌﻴﻦ ﻭﺍﻷﺣﺮﻑ ﺍﻷﻭﻟﻰ ﻣﻦ ﺍﺳﻤﻪ‪.‬‬
‫‪16.3‬ﻳﺠﺐ ﺃﻥ ﺗﺘﻀﻤﻦ ﺗﻘﺎﺭﻳﺮ ﻭﻛﺎﻟﺔ ﺍﻻﺧﺘﺒﺎﺭ ﻋﻦ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺍﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﺘﺤﺪﻳﺪ ﺍﻻﻣﺘﺜﺎﻝ ﻟﻬﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺑﻴﺎﻧﺎً ﺑﺄﻥ ﺟﻤﻴﻊ‬ ‫‪14.1.11‬ﻧﻮﻉ ﻭﻛﻤﻴﺔ ﺍﻟﺨﻠﻴﻂ ﺃﻭ ﺍﻟﺘﻌﺪﻳﻼﺕ ﺍﻷﺧﺮﻯ ﺍﻟﺘﻲ ﻳﺘﻢ ﺇﺟﺮﺍﺅﻫﺎ‬
‫ﺍﻻﺧﺘﺒﺎﺭﺍﺕﺍﻟﺘﻲ ﺃﺟﺮﺗﻬﺎ ﻭﻛﺎﻟﺔ ﺍﻻﺧﺘﺒﺎﺭ ﺃﻭ ﻭﻛﻼﺉﻬﺎ ﻛﺎﻧﺖ ﻣﺘﻮﺍﻓﻘﺔ ﻣﻊ‬ ‫ﻋﻠﻰﺍﻟﺪﻓﻌﺔ ﺑﻌﺪ ﺍﻟﺨﻠﻂ‪.‬‬
‫ﻃﺮﻕﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻤﻄﺒﻘﺔ ﺃﻭ ﻳﺠﺐ ﺃﻥ ﺗﻼﺣﻆ ﺟﻤﻴﻊ ﺍﻻﻧﺤﺮﺍﻓﺎﺕ ﺍﻟﻤﻌﺮﻭﻓﺔ‬ ‫‪14.1.12‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺸﺎﺣﻨﺎﺕ ﺍﻟﻤﺠﻬﺰﺓ ﺑﺄﺟﻬﺰﺓ ﻗﻴﺎﺱ ﺃﻭﺗﻮﻣﺎﺗﻴﻜﻴﺔ‬
‫ﻋﻦﺍﻹﺟﺮﺍءﺍﺕ ﺍﻟﻤﻨﺼﻮﺹ ﻋﻠﻴﻬﺎ )ﺍﻟﻤﻼﺣﻈﺔ ‪ .(23‬ﻭﻳﺠﺐ ﺃﻥ ﺗﺪﺭﺝ‬ ‫ﻟﻠﻤﻴﺎﻩﺃﻭ ﺍﺧﺘﺰﺍﻝ ﺍﻟﻤﺎء ﻭﻣﻌﺪﺍﺕ ﻣﺮﺍﻗﺒﺔ ﺍﻟﺘﺪﻓﻖ ﺃﻭ ﺍﻟﺮﻛﻮﺩ ﻛﻤﺎ ﻫﻮ ﻣﺤﺪﺩ‬
‫ﺍﻟﺘﻘﺎﺭﻳﺮﺃﻳﻀﺎً ﺃﻱ ﺟﺰء ﻣﻦ ﻃﺮﻕ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﺘﻲ ﻟﻢ ﺗﻨﻔﺬﻫﺎ ﻭﻛﺎﻟﺔ ﺍﻻﺧﺘﺒﺎﺭ‪.‬‬ ‫ﻓﻲ‪ ،12.8.1‬ﺇﺟﻤﺎﻟﻲ ﻛﻤﻴﺔ ﺍﻟﻤﺎء ﺃﻭ ﺧﻠﻴﻂ ﺗﻘﻠﻴﻞ ﺍﻟﻤﺎء ﺍﻟﻤﻀﺎﻓﺔ ﺑﻮﺍﺳﻄﺔ‬
‫ﺍﻟﻤﻌﺪﺍﺕﺍﻟﻤﺬﻛﻮﺭﺓ‪.‬‬
‫ﻥ‪ -23OTE‬ﻗﺪ ﻳﺆﺛﺮ ﺍﻻﻧﺤﺮﺍﻑ ﻋﻦ ﻃﺮﻕ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻘﻴﺎﺳﻴﺔ ﺳﻠﺒﺎً ﻋﻠﻰ ﻧﺘﺎﺉﺞ ﺍﻻﺧﺘﺒﺎﺭ‪.‬‬ ‫‪14.1.13‬ﺣﺪ ﺍﻟﺜﻮﺭﺓ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﺬﻱ ﺗﺤﺪﺩﻩ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻭﻓﻘﺎً ﻟـ‬
‫‪.6.1.9‬‬
‫ﻥ‪—24OTE‬ﺍﻻﻧﺤﺮﺍﻑ ﻋﻦ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻟﻠﺮﻃﻮﺑﺔ ﻭﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ‬
‫‪C31/C31M‬ﻏﺎﻟﺒﺎً ﻣﺎ ﻳﻜﻮﻥ ﺳﺒﺒﺎً ﻻﻧﺨﻔﺎﺽ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ‪ .‬ﻗﺪ ﺗﺆﺩﻱ ﻣﺜﻞ ﻫﺬﻩ‬ ‫‪14.2‬ﻳﺠﺐ ﺗﻘﺪﻳﻢ ﻣﻌﻠﻮﻣﺎﺕ ﺇﺿﺎﻓﻴﺔ ﻷﻏﺮﺍﺽ ﺍﻻﻋﺘﻤﺎﺩ ﻋﻠﻰ ﺍﻟﻨﺤﻮ‬
‫ﺍﻻﻧﺤﺮﺍﻓﺎﺕﺇﻟﻰ ﺇﺑﻄﺎﻝ ﺍﺳﺘﺨﺪﺍﻡ ﻧﺘﺎﺉﺞ ﺍﻻﺧﺘﺒﺎﺭ ﻫﺬﻩ ﻛﺄﺳﺎﺱ ﻟﺮﻓﺾ ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬ ‫ﺍﻟﺬﻱﻳﺤﺪﺩﻩ ﺍﻟﻤﺸﺘﺮﻱ ﻭﺗﺘﻄﻠﺒﻬﺎ ﻣﻮﺍﺻﻔﺎﺕ ﺍﻟﻮﻇﻴﻔﺔ ﻋﻨﺪ ﺍﻟﻄﻠﺐ؛‬
‫ﻣﻌﻠﻮﻣﺎﺕﻣﺜﻞ‪:‬‬
‫‪14.2.1‬ﻗﺮﺍءﺓ ﻋﺪﺍﺩ ﺍﻟﺪﻭﺭﺍﻥ ﻋﻨﺪ ﺃﻭﻝ ﺇﺿﺎﻓﺔ ﻟﻠﻤﺎء‪،‬‬
‫‪.17‬ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﻭﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‬
‫‪17.1‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﻤﻘﺎﻭﻝ ﺃﻥ ﻳﻮﻓﺮ ﻟﻠﻤﻔﺘﺶ ﻛﻞ ﺳﺒﻞ ﺍﻟﻮﺻﻮﻝ‬ ‫‪14.2.2‬ﻧﻮﻉ ﺍﻷﺳﻤﻨﺖ ﻭﻋﻼﻣﺘﻪ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺘﻪ‬
‫ﻭﺍﻟﻤﺴﺎﻋﺪﺓﺍﻟﻤﻌﻘﻮﻟﺔ‪ ،‬ﺩﻭﻥ ﻣﻘﺎﺑﻞ‪ ،‬ﻟﺸﺮﺍء ﻋﻴﻨﺎﺕ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‬ ‫‪14.2.3‬ﺍﻟﻔﺉﺔ ﻭﺍﻟﻌﻼﻣﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺔ ﺍﻟﺮﻣﺎﺩ ﺍﻟﻤﺘﻄﺎﻳﺮ ﻟﻠﻔﺤﻢ ﺃﻭ‬
‫ﻓﻲﻭﻗﺖ ﻭﺿﻌﻬﺎ ﻟﺘﺤﺪﻳﺪ ﻣﺪﻯ ﻣﻄﺎﺑﻘﺘﻬﺎ ﻟﻬﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.‬‬ ‫ﺍﻟﺒﻮﺯﻭﻻﻥﺍﻟﻄﺒﻴﻌﻲ ﺍﻟﺨﺎﻡ ﺃﻭ ﺍﻟﻤﻜﻠﺲ‪،‬‬
‫‪14.2.4‬ﺍﻟﺪﺭﺟﺔ ﻭﺍﻟﻌﻼﻣﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺔ ﺍﻷﺳﻤﻨﺖ ﺍﻟﺨﺒﺚ‪،‬‬
‫‪17.2‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻟﺘﺤﺪﻳﺪ ﻣﺪﻯ‬ ‫‪14.2.5‬ﺍﻟﻨﻮﻉ ﻭﺍﻟﻌﻼﻣﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺔ ﺩﺧﺎﻥ ﺍﻟﺴﻴﻠﻴﻜﺎ‪،‬‬
‫ﻣﻄﺎﺑﻘﺘﻬﺎﻟﻬﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺑﻮﺍﺳﻄﺔ ﻓﻨﻲ ﻣﻌﺘﻤﺪ ﻭﻓﻘﺎً ﻟﻠﻤﻤﺎﺭﺳﺔ‪.C1077‬‬ ‫‪14.2.6‬ﻧﻮﻉ ﺍﻟﺨﻠﻄﺎﺕ ﻭﻋﻼﻣﺘﻬﺎ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺘﻬﺎ‬
‫‪14.2.7‬ﺍﻟﻨﻮﻉ ﻭﺍﻟﻌﻼﻣﺔ ﺍﻟﺘﺠﺎﺭﻳﺔ ﻭﻛﻤﻴﺔ ﺗﻘﻮﻳﺔ ﺍﻷﻟﻴﺎﻑ‪،‬‬
‫‪14.2.8‬ﻣﺼﺪﺭ ﻭﻛﻤﻴﺔ ﻛﻞ ﻣﻴﺎﻩ ﻳﺘﻢ ﻗﻴﺎﺳﻬﺎ ﺃﻭ ﻭﺯﻧﻬﺎ‪،‬‬
‫‪17.3‬ﻳﺠﺐ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻋﻴﻨﺎﺕ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﻓﻘﺎ ًﻟﻠﻤﻤﺎﺭﺳﺔ‬
‫‪ ،C172/C172M‬ﺑﺎﺳﺘﺜﻨﺎء ﺍﻟﺤﺎﻻﺕ ﺍﻟﺘﻲ ﻳﺘﻢ ﻓﻴﻬﺎ ﺗﺤﺪﻳﺪ ﺗﺠﺎﻧﺲ‬
‫‪14.2.9‬ﺍﻟﻤﻌﻠﻮﻣﺎﺕ ﺍﻟﻼﺯﻣﺔ ﻟﺤﺴﺎﺏ ﻣﺎء ﺍﻟﺨﻠﻂ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ‪9.3‬‬
‫ﺍﻟﻬﺒﻮﻁﺿﻤﻦ ﺃﻱ ﺩﻓﻌﺔ ﺃﻭ ﺣﻤﻮﻟﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ )‪ ،13.4,11.4‬ﻭﺍﻟﻤﻠﺤﻖ ﺃ‪1‬‬
‫‪,‬‬
‫(‪.‬‬
‫‪14.2.10‬ﺍﻟﺤﺪ ﺍﻷﻗﺼﻰ ﻟﺤﺠﻢ ﺍﻟﺮﻛﺎﻡ‪،‬‬
‫‪17.4‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﺮﻛﻮﺩ ﺃﻭ ﺍﻟﺘﺪﻓﻖ ﻭﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻭﺍﻟﻜﺜﺎﻓﺔ‬ ‫‪14.2.11‬ﻛﺘﻠﺔ )ﻛﻤﻴﺔ( ﺍﻟﺮﻛﺎﻡ ﺍﻟﻨﺎﻋﻢ ﻭﺍﻟﺨﺸﻦ‪،‬‬
‫ﻭﺩﺭﺟﺔﺍﻟﺤﺮﺍﺭﺓ ﻓﻲ ﻭﻗﺖ ﺍﻟﺘﻔﺮﻳﻎ ﺣﺴﺐ ﺍﺧﺘﻴﺎﺭ ﺍﻟﻤﻔﺘﺶ ﻛﻠﻤﺎ ﻛﺎﻥ ﺫﻟﻚ‬ ‫‪14.2.12‬ﺍﻟﻤﻜﻮﻧﺎﺕ ﺍﻟﻤﻌﺘﻤﺪﺓ ﻋﻠﻰ ﺃﻧﻬﺎ ﻣﻌﺘﻤﺪﺓ ﻣﺴﺒﻘﺎً‪ ،‬ﻭ‬
‫ﺿﺮﻭﺭﻳﺎًﻟﻔﺤﻮﺻﺎﺕ ﺍﻟﻤﺮﺍﻗﺒﺔ‪ .‬ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺫﻟﻚ‪ ،‬ﻳﺠﺐ ﺇﺟﺮﺍء ﻫﺬﻩ‬
‫ﺍﻻﺧﺘﺒﺎﺭﺍﺕﻋﻨﺪ ﺗﺤﺪﻳﺪﻫﺎ ﻭﺩﺍﺉﻤﺎً ﻋﻨﺪ ﺇﺟﺮﺍء ﻋﻴﻨﺎﺕ ﺍﻟﻘﻮﺓ‪.‬‬ ‫‪14.2.13‬ﺍﻟﺘﻮﻗﻴﻊ ﺃﻭ ﺍﻷﺣﺮﻑ ﺍﻷﻭﻟﻰ ﻣﻦ ﺍﺳﻢ ﻣﻤﺜﻞ ﺍﻟﻤﻨﺘﺞ‪.‬‬

‫‪17.5‬ﻳﺠﺐ ﻋﻤﻮﻣﺎً ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﻘﻮﺓ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﺍﺧﺘﺒﺎﺭﺍﺕ‬ ‫‪.15‬ﺗﻔﺘﻴﺶ ﺍﻟﻤﺼﻨﻊ‬
‫ﺍﻻﻧﺤﺪﺍﺭﺃﻭ ﺍﻻﻧﺤﺪﺍﺭ ﻓﻲ ﺍﻟﺠﺮﻳﺎﻥ ﻭﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﻭﺍﻟﻜﺜﺎﻓﺔ ﻭﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‬ ‫‪15.1‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﺃﻥ ﺗﺘﻴﺢ ﻟﻠﻤﻔﺘﺶ ﺇﻣﻜﺎﻧﻴﺔ ﺍﻟﻮﺻﻮﻝ‬
‫ﺑﺘﻜﺮﺍﺭﻻ ﻳﻘﻞ ﻋﻦ ﺍﺧﺘﺒﺎﺭ ﻭﺍﺣﺪ ﻟﻜﻞ ‪ 115‬ﻣﺘﺮﺍً‪3.‬‬ ‫ﺍﻟﻤﻌﻘﻮﻟﺔ‪،‬ﺩﻭﻥ ﻣﻘﺎﺑﻞ‪ ،‬ﻹﺟﺮﺍء ﺍﻟﻔﺤﻮﺻﺎﺕ ﺍﻟﻼﺯﻣﺔ ﻟﻤﺮﺍﻓﻖ ﺍﻹﻧﺘﺎﺝ‬
‫]‪ 150‬ﻳﺎﺭﺩﺓ‪ .[3‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﻛﻞ ﺍﺧﺘﺒﺎﺭ ﻣﻦ ﺩﻓﻌﺔ ﻣﻨﻔﺼﻠﺔ‪ .‬ﻓﻲ ﻛﻞ ﻳﻮﻡ‬ ‫ﻭﻟﺘﺄﻣﻴﻦﺍﻟﻌﻴﻨﺎﺕ ﺍﻟﻼﺯﻣﺔ ﻟﺘﺤﺪﻳﺪ ﻣﺎ ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻳﺘﻢ ﺇﻧﺘﺎﺟﻬﺎ ﻭﻓﻘﺎً‬
‫ﻳﺘﻢﻓﻴﻪ ﺗﺴﻠﻴﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﻭﺍﺣﺪ ﻋﻠﻰ ﺍﻷﻗﻞ ﻟﻜﻞ‬ ‫ﻟﻬﺬﻩﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ .‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺟﻤﻴﻊ ﺍﻻﺧﺘﺒﺎﺭﺍﺕ ﻭﺍﻟﺘﻔﺘﻴﺶ ﺑﺤﻴﺚ ﻻ‬
‫ﻓﺉﺔﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬ ‫ﺗﺘﺪﺍﺧﻞﺑﺸﻜﻞ ﻏﻴﺮ ﺿﺮﻭﺭﻱ ﻣﻊ ﺗﺼﻨﻴﻊ ﻭﺗﺴﻠﻴﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ‪.‬‬
‫‪17.6‬ﻓﻲ ﺣﺎﻟﺔ ﺇﺟﺮﺍء ﻓﺤﻮﺻﺎﺕ ﺃﻭﻟﻴﺔ ﻟﻠﺮﻛﻮﺩ ﺃﻭ ﺗﺪﻓﻖ ﺍﻟﺮﻛﻮﺩ ﺃﻭ‬
‫ﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء‪ ،‬ﻳﺠﺐ ﺃﺧﺬ ﻋﻴﻨﺔ ﻭﺍﺣﺪﺓ ﺑﻌﺪ ﺗﻔﺮﻳﻎ ﻣﺎ ﻻ ﻳﻘﻞ ﻋﻦ‪4⁄1‬ﻡ‪3‬ﺃﻭ ‪⁄‬‬
‫‪4 1‬‬

‫ﻳﺎﺭﺩﺓ‪ .3‬ﺟﻤﻴﻊ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻷﺧﺮﻯ‪C172/C172M‬ﻳﺠﺐ‬


‫ﺍﻻﺣﺘﻔﺎﻅﺑﻬﺎ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻘﻴﺎﺱ ﺍﻷﻭﻟﻲ ﻟﻠﺮﻛﻮﺩ )‪ (12.7‬ﺃﻭ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء )‬ ‫‪.16‬ﺍﻟﻤﻤﺎﺭﺳﺎﺕ ﻭﻃﺮﻕ ﺍﻻﺧﺘﺒﺎﺭ ﻭﺇﻋﺪﺍﺩ ﺍﻟﺘﻘﺎﺭﻳﺮ‬
‫‪ (8.3‬ﻳﻘﻊ ﺧﺎﺭﺝ ﺍﻟﺤﺪﻭﺩ ﺍﻟﻤﺤﺪﺩﺓ‪ ،‬ﺍﻟﻌﻨﻮﺍﻥ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ﺍﻟﻘﺴﻢ‬ ‫‪16.1‬ﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻭﻓﻘﺎ ًﻟﻠﻄﺮﻕ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬

‫‪17.6.1‬ﺃﻭ‪17.6.2‬ﺣﺴﺐ ﺍﻻﻗﺘﻀﺎء‪.‬‬ ‫‪16.1.1‬ﻋﻴﻨﺎﺕ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻀﻐﻂ —ﻳﻤﺎﺭﺱ‪C31/C31M‬ﺑﺎﺳﺘﺨﺪﺍﻡ‬


‫‪17.6.1‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻻﻧﺤﺪﺍﺭ ﺍﻟﻤﻘﺎﺱ ﺃﻭ ﺗﺪﻓﻖ ﺍﻻﻧﺤﺪﺍﺭ‪ ،‬ﺃﻭ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‪،‬‬ ‫ﺍﻟﻤﻌﺎﻟﺠﺔﺍﻟﺮﻃﺒﺔ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻭﻓﻘﺎً ﻷﺣﻜﺎﻡ ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻤﻌﻤﻮﻝ ﺑﻬﺎ‪/C31M‬‬
‫ﺃﻭﻛﻠﻴﻬﻤﺎ ﺃﻛﺒﺮ ﻣﻦ ﺍﻟﺤﺪ ﺍﻷﻋﻠﻰ ﺍﻟﻤﺤﺪﺩ‪ ،‬ﻓﻴﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﻓﺤﺺ ﻓﻮﺭﺍً‬ ‫‪.C31‬‬
‫ﻋﻠﻰﻋﻴﻨﺔ ﺍﺧﺘﺒﺎﺭ ﺟﺪﻳﺪﺓ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﻓﺸﻞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻔﺤﺺ‪ ،‬ﺗﻌﺘﺒﺮ ﺍﻟﺨﺮﺳﺎﻧﺔ‬ ‫‪16.1.2‬ﺍﺧﺘﺒﺎﺭﺍﺕ ﺍﻟﻀﻐﻂ —ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪.C39/C39M‬‬
‫ﻗﺪﻓﺸﻠﺖ ﻓﻲ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.‬‬ ‫‪16.1.3‬ﺍﻟﻌﺎﺉﺪ‪ ،‬ﺍﻟﻜﺘﻠﺔ ﻟﻜﻞ ﻗﺪﻡ ﻣﻜﻌﺐ—ﻃﺮﻳﻘﺔ ﺍﺧﺘﺒﺎﺭ‪/C138M‬‬
‫‪.C138‬‬

‫‪9‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﺍﻟﻤﻮﻗﻊﻓﻲ ﺍﻟﻌﻤﻞ ﺍﻟﺬﻱ ﻳﺘﻢ ﻓﻴﻪ ﺇﻳﺪﺍﻉ ﻛﻞ ﺣﻤﻞ ﻳﻤﺜﻠﻪ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ‪.‬‬ ‫‪17.6.2‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻻﻧﺤﺪﺍﺭ ﺍﻟﻤﻘﺎﺱ ﺃﻭ ﺗﺪﻓﻖ ﺍﻻﻧﺤﺪﺍﺭ‪ ،‬ﺃﻭ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء‪،‬‬
‫ﺃﻭﻛﻠﻴﻬﻤﺎ ﺃﻗﻞ ﻣﻦ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ‪ ،‬ﻓﻴﺠﺐ ﺍﻟﺴﻤﺎﺡ ﺑﺎﻟﺘﻌﺪﻳﻼﺕ ﻭﻓﻘﺎً ﻟﻤﺎ ﻳﻠﻲ‪:‬‬
‫‪18.4‬ﻟﻠﺘﻮﺍﻓﻖ ﻣﻊ ﻣﺘﻄﻠﺒﺎﺕ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺔ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﺴﺘﻮﻓﻲ‬ ‫‪12.7‬ﺃﻭ‪8.3‬ﺃﻭ ﻛﻠﻴﻬﻤﺎ‪ ،‬ﺣﺴﺐ ﺍﻻﻗﺘﻀﺎء‪ ،‬ﻭﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻋﻴﻨﺔ ﺟﺪﻳﺪﺓ‪.‬‬
‫ﺍﺧﺘﺒﺎﺭﺍﺕﺍﻟﻘﻮﺓ ﺍﻟﺘﻲ ﺗﻤﺜﻞ ﻛﻞ ﻓﺉﺔ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺘﻄﻠﺒﻴﻦ ﺍﻟﺘﺎﻟﻴﻴﻦ )‬ ‫ﻓﻲﺣﺎﻟﺔ ﻓﺸﻞ ﻋﻴﻨﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻌﺪﻟﺔ‪ ،‬ﻳﺠﺐ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﻓﺤﺺ ﻓﻮﺭﺍً‬
‫ﺍﻟﻤﻼﺣﻈﺔ‪:(26‬‬ ‫ﻋﻠﻰﻋﻴﻨﺔ ﺟﺪﻳﺪﺓ ﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻌﺪﻟﺔ‪ .‬ﻓﻲ ﺣﺎﻟﺔ ﻓﺸﻞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻔﺤﺺ‪،‬‬
‫‪18.4.1‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻣﺘﻮﺳﻂ ﺃﻱ ﺛﻼﺛﺔ ﺍﺧﺘﺒﺎﺭﺍﺕ ﻗﻮﺓ ﻣﺘﺘﺎﻟﻴﺔ‬ ‫ﺗﻌﺘﺒﺮﺍﻟﺨﺮﺳﺎﻧﺔ ﻗﺪ ﻓﺸﻠﺖ ﻓﻲ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.‬‬
‫ﻣﺴﺎﻭﻳﺎ ًﺃﻭ ﺃﻛﺒﺮ ﻣﻦ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ‪F '،‬ﺝ‪ ،‬ﻭ‬
‫‪18.4.2‬ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ ‪ 35‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‪ 5000‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ‬
‫ﻣﺮﺑﻌﺔ[ ﺃﻭ ﺃﻗﻞ‪ ،‬ﻳﺠﺐ ﺃﻻ ﻳﻜﻮﻥ ﺃﻱ ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﻓﺮﺩﻱ )ﻣﺘﻮﺳﻂ ﺍﺧﺘﺒﺎﺭﻳﻦ ﻟﻸﺳﻄﻮﺍﻧﺔ(‬
‫ﺃﻗﻞﻣﻦ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ ﺑﺄﻛﺜﺮ ﻣﻦ ‪ 3.5‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‪ 500‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‪F '،‬ﺝ‬ ‫‪.18‬ﺍﻟﻘﻮﺓ‬
‫‪.‬‬ ‫‪18.1‬ﻋﻨﺪ ﺍﺳﺘﺨﺪﺍﻡ ﺍﻟﻘﻮﺓ ﻛﺄﺳﺎﺱ ﻟﻘﺒﻮﻝ ﺍﻟﺨﺮﺳﺎﻧﺔ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ‬
‫ﻥ‪ -26OTE‬ﻧﻈﺮﺍً ﻟﻼﺧﺘﻼﻓﺎﺕ ﻓﻲ ﺍﻟﻤﻮﺍﺩ ﻭﺍﻟﻌﻤﻠﻴﺎﺕ ﻭﺍﻻﺧﺘﺒﺎﺭﺍﺕ‪ ،‬ﻓﺈﻥ ﻣﺘﻮﺳﻂ‬ ‫ﻋﻤﻞﺍﻟﻌﻴﻨﺎﺕ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻃﺒﻘﺎ ًﻟﻠﻤﻤﺎﺭﺳﺔ‪ .C31/C31M‬ﻳﺠﺐ ﻣﻌﺎﻟﺠﺔ‬
‫ﺍﻟﻘﻮﺓﺍﻟﻼﺯﻣﺔ ﻟﺘﻠﺒﻴﺔ ﻫﺬﻩ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﺳﻴﻜﻮﻥ ﺃﻋﻠﻰ ﺑﻜﺜﻴﺮ ﻣﻦ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ‪ .‬ﻳﻌﺘﻤﺪ‬ ‫ﺍﻟﻌﻴﻨﺎﺕﻓﻲ ﻇﻞ ﻇﺮﻭﻑ ﺍﻟﺮﻃﻮﺑﺔ ﻭﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻘﻴﺎﺳﻴﺔ ﻭﻓﻘﺎً ﻷﺣﻜﺎﻡ‬
‫ﺍﻟﻤﺒﻠﻎﺍﻷﻋﻠﻰ ﻋﻠﻰ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ ﻟﻨﺘﺎﺉﺞ ﺍﻻﺧﺘﺒﺎﺭ ﻭﺍﻟﺪﻗﺔ ﺍﻟﺘﻲ ﻳﻤﻜﻦ ﺑﻬﺎ ﺗﻘﺪﻳﺮ‬ ‫ﺍﻟﻤﻤﺎﺭﺳﺔﺍﻟﻤﻌﻤﻮﻝ ﺑﻬﺎ‪ .C31/C31M‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺍﻋﺘﻤﺎﺩ ﺍﻟﻔﻨﻲ ﺍﻟﺬﻱ‬
‫ﺗﻠﻚﺍﻟﻘﻴﻤﺔ ﻣﻦ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﺴﺎﺑﻘﺔ ﻛﻤﺎ ﻫﻮ ﻣﻮﺿﺢ ﻓﻲ ‪6ACI 214R‬ﻭ‪ .ACI 301‬ﻭﺗﺮﺩ‬
‫ﻳﻘﻮﻡﺑﺈﺟﺮﺍء ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ ﺑﺎﻋﺘﺒﺎﺭﻩ ﻓﻨﻲ ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﻦ ‪ ،ACI‬ﺃﻭ‬
‫ﺍﻟﺒﻴﺎﻧﺎﺕﺫﺍﺕ ﺍﻟﺼﻠﺔ ﻓﻲﺍﻟﻤﻠﺤﻖ ‪.X1‬‬
‫ﻓﻨﻲﺍﺧﺘﺒﺎﺭ ﻣﺨﺘﺒﺮ ﺍﻟﺨﺮﺳﺎﻧﺔ ‪ -‬ﺍﻟﺪﺭﺟﺔ ﺍﻟﺜﺎﻧﻴﺔ ﺃﻭ ﻣﻦ ﺧﻼﻝ ﺑﺮﻧﺎﻣﺞ ﺍﺧﺘﺒﺎﺭ‬
‫ﻛﺘﺎﺑﻲﻭﺃﺩﺍء ﻣﻜﺎﻓﺊ ﻳﻐﻄﻲ ﻃﺮﻕ ﺍﻻﺧﺘﺒﺎﺭ ﺫﺍﺕ ﺍﻟﺼﻠﺔ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻘﺒﻮﻝ‬
‫‪18.4.3‬ﻋﻨﺪﻣﺎ ﺗﻜﻮﻥ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ ﺃﻛﺒﺮ ﻣﻦ ‪ 35‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‪5000‬‬
‫ﻳﻌﺘﻤﺪﻋﻠﻰ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﺍﻟﻀﻐﻂ‪ ،‬ﻓﺴﻴﺘﻢ ﺍﺳﺘﻴﻔﺎء ﻣﺘﻄﻠﺒﺎﺕ‬
‫ﺭﻃﻞﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‪ ،‬ﻳﺠﺐ ﺃﻻ ﻳﻘﻞ ﺃﻱ ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﻓﺮﺩﻱ )ﻣﺘﻮﺳﻂ‬
‫ﺍﻟﺸﻬﺎﺩﺓﻣﻦ ﺧﻼﻝ ﺍﻻﻋﺘﻤﺎﺩ ﻛﻔﻨﻲ ﺍﺧﺘﺒﺎﺭ ﻣﺨﺘﺒﺮ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﻦ ‪- ACI‬‬
‫ﺍﺧﺘﺒﺎﺭﺍﺳﻄﻮﺍﻧﺘﻴﻦ( ﻋﻦ ‪'F0.90‬ﺝ‪.‬‬
‫ﺍﻟﺪﺭﺟﺔﺍﻷﻭﻟﻰ ﺃﻭ ﻣﻦ ﺧﻼﻝ ﺑﺮﻧﺎﻣﺞ ﺍﺧﺘﺒﺎﺭ ﻣﻜﺘﻮﺏ ﻭﺃﺩﺍء ﻣﻜﺎﻓﺊ‪.‬‬
‫‪.19‬ﺍﻟﻔﺸﻞ ﻓﻲ ﺗﻠﺒﻴﺔ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﻮﺓ‬
‫‪19.1‬ﻓﻲ ﺣﺎﻟﺔ ﺍﺧﺘﺒﺎﺭ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻃﺒﻘﺎ ًﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﺴﻢ‪18‬ﺇﺫﺍ ﻓﺸﻠﺖ‬
‫ﻓﻲﺗﻠﺒﻴﺔ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﻮﺓ ﻟﻬﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪ ،‬ﻳﺠﺐ ﻋﻠﻰ ﺍﻟﺸﺮﻛﺔ‬
‫ﺍﻟﻤﺼﻨﻌﺔﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﺠﺎﻫﺰﺓ ﻭﺍﻟﻤﺸﺘﺮﻱ ﺃﻥ ﻳﺘﺸﺎﻭﺭﺍ ﻟﺘﺤﺪﻳﺪ ﻣﺎ ﺇﺫﺍ ﻛﺎﻥ‬ ‫‪18.2‬ﺑﺎﻟﻨﺴﺒﺔ ﻻﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﻋﻤﻞ ﻋﻴﻨﺘﻴﻦ ﺍﺧﺘﺒﺎﺭﻳﺘﻴﻦ‬
‫ﻣﻦﺍﻟﻤﻤﻜﻦ ﺍﻟﺘﻮﺻﻞ ﺇﻟﻰ ﺍﺗﻔﺎﻕ ﺑﺸﺄﻥ ﺍﻟﺘﻌﺪﻳﻞ ﺃﻭ ﺍﻟﺘﻌﺪﻳﻼﺕ‪ ،‬ﺇﻥ‬ ‫ﻗﻴﺎﺳﻴﺘﻴﻦﻋﻠﻰ ﺍﻷﻗﻞ ﻣﻦ ﻋﻴﻨﺔ ﻣﺮﻛﺒﺔ ﻣﺆﻣﻨﺔ ﻛﻤﺎ ﻫﻮ ﻣﻄﻠﻮﺏ ﻓﻲ ﺍﻟﻘﺴﻢ‪.‬‬
‫ﻭﺟﺪﺕ‪،‬ﺍﻟﺘﻲ ﻳﺠﺐ ﺇﺟﺮﺍﺅﻫﺎ ﻋﻠﻰ ﻧﺴﺐ ﺍﻟﺨﻠﻴﻂ ﺃﻭ ﻋﻤﻠﻴﺔ ﺍﻹﻧﺘﺎﺝ ﺃﻭ‬ ‫‪ .17‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﻻﺧﺘﺒﺎﺭ ﻫﻮ ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻌﻴﻨﺎﺕ ﺍﻟﺘﻲ ﺗﻢ ﺍﺧﺘﺒﺎﺭﻫﺎ‬
‫ﺇﺟﺮﺍءﺍﺕﺍﻻﺧﺘﺒﺎﺭ‪.‬‬ ‫ﻓﻲﺍﻟﻌﻤﺮ ﺍﻟﻤﺤﺪﺩ ﻓﻲ‪6.4.1.1‬ﺃﻭ‪)6.6.1.1‬ﺍﻟﻤﻼﺣﻈﺔ ‪ .(25‬ﺇﺫﺍ ﺃﻇﻬﺮﺕ‬
‫ﺍﻟﻌﻴﻨﺔﺩﻟﻴﻼ ًﻗﺎﻃﻌﺎً ﺑﺨﻼﻑ ﺍﻟﻘﻮﺓ ﺍﻟﻤﻨﺨﻔﻀﺔ‪ ،‬ﻋﻠﻰ ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﺃﻭ ﻗﻮﻟﺒﺔ ﺃﻭ‬
‫ﻥ‪.OTE‬ﻳﺘﻨﺎﻭﻻﻥ ﻣﺘﻰ ﻭﻛﻴﻒ ﻳﻤﻜﻦ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ ﺍﻟﻤﻨﺨﻔﻀﺔ (‬ ‫ﻣﻨﺎﻭﻟﺔﺃﻭ ﻣﻌﺎﻟﺠﺔ ﺃﻭ ﺍﺧﺘﺒﺎﺭ ﻏﻴﺮ ﺻﺤﻴﺢ‪ ،‬ﻓﻴﺠﺐ ﺍﻟﺘﺨﻠﺺ ﻣﻨﻬﺎ ﻭﻳﺠﺐ‬
‫ﺍﻟﺘﻌﻠﻴﻖ) ‪R26.12.4‬ﺍﻟﻘﺴﻤﺎﻥ ‪ 26.12.4‬ﻭ ‪27—ACI 318-14،‬‬ ‫ﺍﻋﺘﺒﺎﺭﻗﻮﺓ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺍﻟﻤﺘﺒﻘﻴﺔ ﻧﺘﻴﺠﺔ ﺍﻻﺧﺘﺒﺎﺭ‪.‬‬
‫‪.20‬ﺍﻟﻜﻠﻤﺎﺕ ﺍﻟﺮﺉﻴﺴﻴﺔ‬

‫ﺩﻗﺔ‪20.1‬؛ ﺍﻷﺳﻤﻨﺖ ﺍﻟﻬﻴﺪﺭﻭﻟﻴﻜﻲ ﺍﻟﻤﺨﻠﻮﻁ ﺷﻬﺎﺩﺓ؛ ﺧﺮﺳﺎﻧﺔ ﺟﺎﻫﺰﺓ؛‬ ‫ﻥ‪ -25OTE‬ﻗﺪ ﻳﺘﻢ ﺇﺟﺮﺍء ﺍﺧﺘﺒﺎﺭﺍﺕ ﺇﺿﺎﻓﻴﺔ ﻓﻲ ﺃﻋﻤﺎﺭ ﺃﺧﺮﻯ ﻟﻠﺤﺼﻮﻝ ﻋﻠﻰ ﻣﻌﻠﻮﻣﺎﺕ‬
‫ﻟﺘﺤﺪﻳﺪﻭﻗﺖ ﺇﺯﺍﻟﺔ ﺍﻟﻨﻤﻮﺫﺝ ﺃﻭ ﻣﺘﻰ ﻳﻤﻜﻦ ﻭﺿﻊ ﺍﻟﻬﻴﻜﻞ ﻓﻲ ﺍﻟﺨﺪﻣﺔ‪ .‬ﻳﺘﻢ ﻣﻌﺎﻟﺠﺔ‬
‫ﻣﻘﺎﻳﻴﺲ؛ﺍﺧﺘﺒﺎﺭﺍﺕ‬ ‫ﺍﻟﻌﻴﻨﺎﺕﺍﻟﺨﺎﺻﺔ ﺑﻬﺬﻩ ﺍﻻﺧﺘﺒﺎﺭﺍﺕ ﻭﻓﻘﺎً ﻟﻠﻘﺴﻢ ﺍﻟﺨﺎﺹ ﺑﺎﻟﻤﻌﺎﻟﺠﺔ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ ﻋﻤﻠﻴﺎً‬
‫‪.C31/C31M‬‬
‫‪.6‬ﺻﻔﺤﺔ ‪، www.concrete.org، 2011، 16‬ﺩﻟﻴﻞ ﺗﻘﻴﻴﻢ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ ﻗﻮﺓ ﺍﻟﺨﺮﺳﺎﻧﺔ"‪ ،‬ﻣﺘﺎﺡ‬
‫ﻣﻦﻣﻌﻬﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻷﻣﺮﻳﻜﻲ‪ ،‬ﻓﺎﺭﻣﻨﺠﺘﻮﻥ ﻫﻴﻠﺰ‪ ،‬ﻣﻴﺸﻴﻐﺎﻥ" ‪ACI 214R-11،‬‬ ‫‪18.3‬ﻳﺠﺐ ﻋﻠﻰ ﻣﻤﺜﻞ ﺍﻟﻤﺸﺘﺮﻱ ﺍﻟﺘﺄﻛﺪ ﻣﻦ ﻭﺗﺴﺠﻴﻞ ﺭﻗﻢ ﺗﺬﻛﺮﺓ‬
‫ﺍﻟﺘﺴﻠﻴﻢﻟﻠﺨﺮﺳﺎﻧﺔ ﻭﺍﻟﺪﻗﻴﻘﺔ‬

‫ﺍﻟﻤﺮﻓﻖ‬

‫)ﻣﻌﻠﻮﻣﺎﺕ ﺇﻟﺰﺍﻣﻴﺔ(‬

‫ﺃ‪.1‬ﻣﺘﻄﻠﺒﺎﺕ ﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ‬

‫ﺃ‪1.1.2‬ﻟﺘﺴﻠﺴﻞ ﻭﻃﺮﻳﻘﺔ ﺷﺤﻦ ﺍﻟﺨﻼﻃﺎﺕ ﺗﺄﺛﻴﺮ ﻛﺒﻴﺮ ﻋﻠﻰ ﺍﻟﻘﺪﺭﺓ ﻋﻠﻰ‬ ‫ﺍﻷﻫﻤﻴﺔﻭﺍﻻﺳﺘﺨﺪﺍﻡ ‪A1.1‬‬
‫ﺇﻧﺘﺎﺝﺧﺮﺳﺎﻧﺔ ﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ‪ .‬ﻳﻤﻜﻦ ﺃﻳﻀﺎً ﺍﺳﺘﺨﺪﺍﻡ ﺍﻹﺟﺮﺍءﺍﺕ‬ ‫ﺃ‪1.1.1‬ﻳﻮﻓﺮ ﻫﺬﺍ ﺍﻟﻤﻠﺤﻖ ﺇﺟﺮﺍءﺍﺕ ﻟﺘﻘﻴﻴﻢ ﻗﺪﺭﺓ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ‬
‫ﺍﻟﻮﺍﺭﺩﺓﻓﻲ ﻫﺬﺍ ﺍﻟﻤﻠﺤﻖ ﻟﺘﻘﻴﻴﻢ ﺗﺄﺛﻴﺮ ﺗﺴﻠﺴﻞ ﺍﻟﺨﻠﻂ ﻟﺸﺤﻦ ﺃﻭ ﺗﺤﻤﻴﻞ‬ ‫ﻭﺍﻟﺸﺎﺣﻨﺎﺕﻋﻠﻰ ﺇﻧﺘﺎﺝ ﺧﺮﺳﺎﻧﺔ ﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ‪ .‬ﻳﻤﻜﻦ ﺃﻳﻀﺎً‬
‫ﺍﻟﺨﻼﻃﺎﺕﺫﺍﺕ ﺍﻟﺤﺎﻟﺔ ﺍﻟﻤﻘﺒﻮﻟﺔ‪.‬‬ ‫ﺍﺳﺘﺨﺪﺍﻡﺍﻹﺟﺮﺍءﺍﺕ ﺍﻟﻤﻮﺿﺤﺔ ﻫﻨﺎ ﻟﺘﺤﺪﻳﺪ ﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﺍﻟﻤﻄﻠﻮﺏ ﻣﻦ‬
‫ﺩﻭﺭﺍﺕﺍﻟﺨﻠﻂ ﻓﻲ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺨﻠﻮﻃﺔ ﺍﻟﻤﻨﻜﻤﺸﺔ‬
‫ﻟﻴﺲﺍﻟﻤﻘﺼﻮﺩ ﺇﺟﺮﺍء ﻫﺬﺍ ﺍﻟﺘﻘﻴﻴﻢ ﺍﻟﻜﺎﻣﻞ ﻋﻠﻰ ﺍﻟﺨﻼﻃﺎﺕ ﺑﺘﺮﺩﺩ‬ ‫ﻭﻟﺘﻘﻴﻴﻢﺗﺠﺎﻧﺲ ﺍﻟﺨﻼﺉﻂ ﺍﻟﺨﺮﺳﺎﻧﻴﺔ ﺍﻟﻤﺴﻠﻤﺔ ﻓﻲ ﻣﻌﺪﺍﺕ ﻏﻴﺮ ﻗﺎﺑﻠﺔ‬
‫ﻣﺤﺪﺩ‪.‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﻤﻌﺪﺍﺕ ﻗﻴﺪ ﺍﻟﺘﺸﻐﻴﻞ‪ ،‬ﻳﺘﻢ ﺇﺟﺮﺍء ﻓﺤﺺ ﺑﺼﺮﻱ ﻟﺤﺎﻟﺔ‬ ‫ﻟﻠﺘﺤﺮﻳﻚ‪.‬‬
‫ﺍﻟﺠﻬﺎﺯ‪A1.1.3‬‬

‫‪10‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﺍﻻﺧﺘﺒﺎﺭﺍﺕﻋﻠﻰ ﺍﻟﻔﻮﺭ‪ .‬ﻭﻳﺠﺐ ﺗﺠﻨﺐ ﺍﻟﻔﺼﻞ ﺃﺛﻨﺎء ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ‬ ‫ﻳﻤﻜﻦﺇﺟﺮﺍء ﺧﻼﻁ ﻻﺭﺗﺪﺍء ﺍﻟﺸﻔﺮﺓ ﻭﺗﺮﺍﻛﻢ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﺘﺼﻠﺒﺔ ﻛﺒﺪﻳﻞ‪ .‬ﺇﺫﺍ‬
‫ﻭﺍﻟﻤﻨﺎﻭﻟﺔ‪.‬ﻳﺠﺐ ﺗﻐﻄﻴﺔ ﻛﻞ ﻋﻴﻨﺔ ﻟﻤﻨﻊ ﻓﻘﺪﺍﻥ ﺍﻟﺮﻃﻮﺑﺔ ﺃﻭ ﺍﻟﺘﻠﻮﺙ‪ .‬ﺃﻋﺪ‬ ‫ﺗﻢﺗﻘﻴﻴﻢ ﺧﻼﻃﺔ ﻭﺍﺣﺪﺓ ﺫﺍﺕ ﺗﺼﻤﻴﻢ ﻣﺤﺪﺩ ﻣﻦ ﺧﻼﻝ ﺍﻹﺟﺮﺍءﺍﺕ ﺍﻟﻮﺍﺭﺩﺓ‬
‫ﻣﺰﺝﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﺍﻟﻼﺯﻡ ﻗﺒﻞ ﺇﺟﺮﺍء ﺍﻻﺧﺘﺒﺎﺭﺍﺕ‪.‬‬ ‫ﻓﻲﻫﺬﺍ ﺍﻟﻤﻠﺤﻖ‪ ،‬ﻓﻴﻤﻜﻦ ﺍﻻﻓﺘﺮﺍﺽ ﺃﻥ ﺍﻟﺨﻼﻃﺎﺕ ﺫﺍﺕ ﻧﻔﺲ ﺍﻟﺘﺼﻤﻴﻢ‬
‫ﺑﺸﻜﻞﺃﺳﺎﺳﻲ ﻭﺑﺄﺣﺠﺎﻡ ﻣﺨﺘﻠﻔﺔ ﺳﺘﻨﺘﺞ ﺃﻳﻀﺎً ﺧﺮﺳﺎﻧﺔ ﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ‬
‫ﺃ‪1.3.2‬ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ ﻣﻦ ﺍﻟﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ —ﻳﺠﺐ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ‬ ‫ﻣﻮﺣﺪ‪.‬ﻳﻤﻜﻦ ﺃﻳﻀﺎً ﺇﺟﺮﺍء ﺟﺰء ﻣﺤﺪﺩ ﻣﻦ ﻫﺬﺍ ﺍﻟﺘﻘﻴﻴﻢ‪ ،‬ﻣﺜﻞ ﻣﻘﺎﺭﻧﺔ‬
‫ﻋﻴﻨﺎﺕﻣﻦ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻣﺒﺎﺷﺮﺓ ﺑﻌﺪ ﺍﻧﺘﻬﺎء ﻣﺪﺓ ﺍﻟﺨﻠﻂ‪ ،‬ﻭﺫﻟﻚ ﻭﻓﻖ ﺃﺣﺪ‬ ‫ﻣﺤﺘﻮﻯﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﺃﻭ ﺍﻟﺮﻛﻮﺩ‪ ،‬ﻛﻤﺆﺷﺮ ﺳﺮﻳﻊ ﻋﻠﻰ ﺗﺠﺎﻧﺲ ﺍﻟﺨﻠﻄﺎﺕ‬
‫ﺍﻹﺟﺮﺍءﺍﺕﺍﻟﺘﺎﻟﻴﺔ‪:‬‬ ‫ﺍﻟﺨﺮﺳﺎﻧﻴﺔ‪.‬‬

‫ﺃ‪1.3.2.1‬ﺍﻹﺟﺮﺍء ﺍﻟﺒﺪﻳﻞ ‪-1‬ﻳﺠﺐ ﺇﻳﻘﺎﻑ ﺍﻟﺨﻼﻁ ﻭﺇﺯﺍﻟﺔ ﺍﻟﻌﻴﻨﺎﺕ‬ ‫ﺧﻠﻴﻂﺍﻟﺨﺮﺳﺎﻧﺔ ﻭﺣﺠﻢ ﺍﻟﺘﺤﻤﻴﻞ ﻭﺍﻟﺨﻠﻂ ‪A1.2‬‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔﺑﺄﻱ ﻭﺳﻴﻠﺔ ﻣﻨﺎﺳﺒﺔ ﻣﻦ ﺍﻟﺨﻼﻁ ﻋﻠﻰ ﻣﺴﺎﻓﺎﺕ ﻣﺘﺴﺎﻭﻳﺔ ﺗﻘﺮﻳﺒﺎ ً‬
‫ﻣﻦﺍﻟﺠﺰء ﺍﻷﻣﺎﻣﻲ ﻭﺍﻟﺨﻠﻔﻲ ﻣﻦ ﺍﻟﺒﺮﻣﻴﻞ‪ ،‬ﺃﻭ‬ ‫ﺃ‪1.2.1‬ﻣﺎ ﻟﻢ ﻳﻜﻦ ﺍﻟﻘﺼﺪ ﻫﻮ ﺗﻘﻴﻴﻢ ﺣﺎﻻﺕ ﺍﻟﻤﺸﺮﻭﻉ ﺍﻟﺨﺎﺻﺔ ﺃﻭ‬
‫ﺍﻟﺨﻠﻄﺎﺕﺍﻟﺨﺮﺳﺎﻧﻴﺔ‪ ،‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﺍﻟﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ ﺍﻟﻤﺴﺘﺨﺪﻡ ﻓﻲ‬
‫ﺃ‪1.3.2.2‬ﺍﻹﺟﺮﺍء ﺍﻟﺒﺪﻳﻞ ‪-2‬ﺃﺛﻨﺎء ﺗﻔﺮﻳﻎ ﺍﻟﺨﻼﻁ‪ ،‬ﻳﺠﺐ ﺃﺧﺬ ﻋﻴﻨﺎﺕ‬ ‫ﻫﺬﺍﺍﻟﺘﻘﻴﻴﻢ ﻧﻤﻮﺫﺟﻴﺎً ﻟﻠﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ ﺍﻟﻤﻨﺘﺞ ﻓﻲ ﻣﻨﺸﺄﺓ ﺍﻹﻧﺘﺎﺝ‪.‬‬
‫ﻓﺮﺩﻳﺔﺑﻌﺪ ﺗﻔﺮﻳﻎ ﺣﻮﺍﻟﻲ ‪ %15‬ﻭ‪ %85‬ﻣﻦ ﺍﻟﺤﻤﻮﻟﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﺗﻮﻓﺮ ﻃﺮﻳﻘﺔ‬ ‫ﺗﺸﻤﻞﺧﺼﺎﺉﺺ ﺍﻟﺨﻠﻴﻂ ﺍﻟﻤﻮﺻﻰ ﺑﻬﺎ ﻣﺎ ﻳﻠﻲ‪:‬‬
‫ﺃﺧﺬﺍﻟﻌﻴﻨﺎﺕ ﺍﻟﻌﻴﻨﺎﺕ ﺍﻟﺘﻲ ﻳﺘﻢ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻴﻬﺎ ﻣﻦ ﺃﺟﺰﺍء ﻣﺘﺒﺎﻋﺪﺓ ﻋﻠﻰ‬
‫ﻧﻄﺎﻕﻭﺍﺳﻊ‪ ،‬ﻭﻟﻜﻦ ﻟﻴﺲ ﻣﻦ ﺃﻃﺮﺍﻑ ﺍﻟﺪﻓﻌﺔ )ﻣﻼﺣﻈﺔ ﺃ‪.(1.2‬‬ ‫ﺃ‪1.2.1.1‬ﻣﺤﺘﻮﻯ ﺍﻟﻤﻮﺍﺩ ﺍﻷﺳﻤﻨﺘﻴﺔ ﻣﻦ ‪ 300‬ﺇﻟﻰ ‪ 350‬ﻛﺠﻢ‪/‬ﻡ‪500]3‬‬
‫ﺇﻟﻰ‪ 600‬ﺭﻃﻞ‪/‬ﻳﺎﺭﺩﺓ‪،[3‬‬
‫ﺃ‪1.2.1.2‬ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﻣﻘﺎﺱ ﺭﻗﻢ ‪ 57‬ﺃﻭ ﺭﻗﻢ ‪ 67‬ﻣﻦ ﺍﻟﻤﻮﺍﺻﻔﺔ‬
‫‪,C33/C33M‬‬
‫ﺃ‪1.3.3‬ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ ﻣﻦ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ —ﻳﺠﺐ ﺃﻥ ﻳﺘﻢ ﺗﻔﺮﻳﻎ‬ ‫ﺃ‪1.2.1.3‬ﻣﻌﺎﻣﻞ ﺩﻗﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺪﻗﻴﻖ ﻣﻦ ‪ 2.5‬ﺇﻟﻰ ‪ ،3.0‬ﺃ‪ 1.2.1.4‬ﺍﻻﻧﺤﺪﺍﺭ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔﺑﻤﻌﺪﻝ ﺍﻟﺘﺸﻐﻴﻞ ﺍﻟﻄﺒﻴﻌﻲ ﻟﻠﺨﻼﻁ ﺍﻟﺬﻱ ﻳﺘﻢ ﺍﺧﺘﺒﺎﺭﻩ‪ ،‬ﻣﻊ‬ ‫ﺍﻟﻤﺴﺘﻬﺪﻑﻣﻦ ‪ 100‬ﺇﻟﻰ ‪ 150‬ﻣﻠﻢ ]‪ 4‬ﺇﻟﻰ ‪ 6‬ﺑﻮﺻﺎﺕ[ ﺃﻭ ﻟﻌﻤﻠﻴﺎﺕ‬
‫ﺍﻟﺤﺮﺹﻋﻠﻰ ﻋﺪﻡ ﻋﺮﻗﻠﺔ ﺃﻭ ﺗﺄﺧﻴﺮ ﺍﻟﺘﻔﺮﻳﻎ‪ .‬ﺧﻼﻝ ﺍﻟﻔﺘﺮﺓ ﺍﻟﻔﺎﺻﻠﺔ ﺑﻴﻦ‬ ‫ﺍﻟﺮﺻﻒﻋﻨﺪ ‪ 25‬ﺇﻟﻰ ‪ 50‬ﻣﻠﻢ ]‪ 1‬ﺇﻟﻰ ‪ 2‬ﺑﻮﺻﺔ[‪ ،‬ﻭ‬
‫ﺍﻟﺤﺼﻮﻝﻋﻠﻰ ﺍﻟﻌﻴﻨﺎﺕ‪ ،‬ﻳﺠﺐ ﺇﺩﺍﺭﺓ ﺍﻟﺨﻼﻁ ﻓﻲ ﺍﺗﺠﺎﻩ ﺍﻟﺨﻠﻂ ﺑﺴﺮﻋﺔ‬ ‫ﺃ‪1.2.1.5‬ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻣﻦ ‪ 4‬ﺇﻟﻰ ‪.%6‬‬
‫ﺍﻟﺘﻘﻠﻴﺐ‪.‬ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺍﻟﻌﻴﻨﺎﺕ ﻋﻦ ﻃﺮﻳﻖ ﺍﻋﺘﺮﺍﺽ ﺗﻴﺎﺭ ﺍﻟﺘﻔﺮﻳﻎ ﺍﻟﻜﺎﻣﻞ‬
‫ﻣﻦﺍﻟﻤﺰﻟﻖ ﺩﻭﻥ ﺗﻮﻗﻒ ﻭﺑﺪء ﺍﻟﺘﻔﺮﻳﻎ ﺃﺛﻨﺎء ﺟﻤﻊ ﺍﻟﻌﻴﻨﺔ‪.‬‬ ‫ﻳﺠﺐﺃﻥ ﻳﻜﻮﻥ ﺣﺠﻢ ﺍﻟﺘﺤﻤﻴﻞ ﺍﻟﻤﺴﺘﺨﺪﻡ ﻟﻬﺬﺍ ﺍﻟﺘﻘﻴﻴﻢ ﻓﻲ ﺣﺪﻭﺩ ‪A1.2.2‬‬
‫– ‪ 20%‬ﻭ‪ %10+‬ﻣﻦ ﻗﺪﺭﺓ ﺍﻟﺨﻠﻂ ﺍﻟﻤﻘﺪﺭﺓ ﻟﻠﺨﻼﻁ‪.‬‬
‫ﺃ‪1.2.3‬ﺍﺳﺘﺨﺪﻡ ﺗﺴﻠﺴﻞ ﺧﻠﻂ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺨﺮﺳﺎﻧﻴﺔ ﺍﻟﺘﻲ ﺗﻢ ﺍﺳﺘﺨﺪﺍﻣﻬﺎ‬
‫ﺃ‪1.3.4‬ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ ﻣﻦ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻤﺘﺤﺮﻛﺔ —ﺍﺣﺼﻞ ﻋﻠﻰ‬ ‫ﺳﺎﺑﻘﺎًﺑﻨﺠﺎﺡ ﺃﻭ ﻭﻓﻘﺎً ﻟﺘﻮﺻﻴﺔ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻟﻠﺨﻼﻁ‪ .‬ﺍﺳﺘﺨﺪﻡ‬
‫ﺍﻟﻌﻴﻨﺘﻴﻦﻣﻦ ﺣﻮﺍﻟﻲ ‪ %15‬ﻭ‪ %85‬ﻣﻦ ﺍﻟﺘﻔﺮﻳﻎ ﻣﻦ ﺍﻟﻤﻌﺪﺍﺕ ﻏﻴﺮ ﺍﻟﻘﺎﺑﻠﺔ‬ ‫ﺇﺟﺮﺍءﺍﺕﺑﺪﻳﻠﺔ ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﻐﺮﺽ ﻫﻮ ﺗﻘﻴﻴﻢ ﺗﺄﺛﻴﺮ ﺗﺴﻠﺴﻞ ﺍﻟﺨﻠﻂ‪.‬‬
‫ﻟﻠﺘﺤﺮﻳﻚﻭﻓﻘﺎً ﻟﻠﻤﻤﺎﺭﺳﺔ‪ .C172/C172M‬ﺧﻠﻂ ﺍﻷﺟﺰﺍء ﺍﻟﺘﻲ ﺗﻢ ﺍﻟﺤﺼﻮﻝ‬
‫ﻋﻠﻴﻬﺎﻣﻦ ﻛﻞ ﻣﻮﻗﻊ ﺇﻟﻰ ﻋﻴﻨﺎﺕ ﻣﺨﺘﻠﻄﺔ ﺑﺸﻜﻞ ﻣﻮﺣﺪ‪.‬‬
‫ﻥ‪.OTE‬ﺗﻮﺻﻴﺎﺕ ﺑﺸﺄﻥ ﺗﺴﻠﺴﻞ ﺍﻟﺨﻠﻂ ‪، CPMB 100،‬ﻭﻣﻜﺘﺐ ﻣﺼﻨﻌﻲ ﻣﺼﺎﻧﻊ‬
‫ﺍﻟﺨﺮﺳﺎﻧﺔ‪، TMMB 100‬ﺗﻮﻓﺮ ﻣﻌﺎﻳﻴﺮ ﻣﻜﺘﺐ ﻣﺼﻨﻌﻲ ﺧﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ — ‪A1.1‬‬
‫ﻥ‪OTE‬ﺃ‪ - 1.2‬ﻻ ﻳﻨﺒﻐﻲ ﺃﺧﺬ ﻋﻴﻨﺎﺕ ﻗﺒﻞ ‪ %10‬ﺃﻭ ﺑﻌﺪ ﺗﻔﺮﻳﻎ ‪ %90‬ﻣﻦ ﺍﻟﺪﻓﻌﺔ‪ .‬ﻧﻈﺮﺍً‬
‫ﻟﺼﻌﻮﺑﺔﺗﺤﺪﻳﺪ ﺍﻟﻜﻤﻴﺔ ﺍﻟﻔﻌﻠﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻤﻔﺮﻏﺔ‪ ،‬ﻓﺈﻥ ﺍﻟﻬﺪﻑ ﻫﻮ ﺗﻘﺪﻳﻢ ﻋﻴﻨﺎﺕ ﺗﻤﺜﻞ‬
‫ﺍﻷﺟﺰﺍءﺍﻟﻤﻨﻔﺼﻠﺔ ﻋﻠﻰ ﻧﻄﺎﻕ ﻭﺍﺳﻊ‪ ،‬ﻭﻟﻜﻦ ﻟﻴﺲ ﺑﺪﺍﻳﺔ ﺍﻟﺤﻤﻞ ﻭﻧﻬﺎﻳﺘﻪ‪.‬‬ ‫ﺃ‪1.2.4‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ‪ ،‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺑﺴﺮﻋﺔ ﺍﻟﺨﻠﻂ‬
‫ﻭﺑﺎﻟﻤﺪﺓﺍﻟﺪﻧﻴﺎ ﺍﻟﻤﻮﺻﻰ ﺑﻬﺎ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ ﺍﻟﻤﺼﻨﻌﺔ ﻟﻠﺨﻼﻁ‪ .‬ﻳﺠﺐ ﺃﻥ‬
‫ﺗﻜﻮﻥﺑﺪﺍﻳﺔ ﺯﻣﻦ ﺍﻟﺨﻠﻂ ﻣﻦ ﻭﻗﺖ ﻭﺟﻮﺩ ﺟﻤﻴﻊ ﺍﻟﻤﻮﺍﺩ ﺍﻟﺼﻠﺒﺔ ﻓﻲ ﺍﻟﺨﻼﻁ‪.‬‬
‫ﺍﻟﺮﻛﻮﺩ‪A1.4‬‬ ‫ﻳﺘﻢﺃﺧﺬ ﻭﻗﺖ ﺍﻟﺨﻠﻂ ﻋﻠﻰ ﺃﻧﻪ ﺃﻳﻬﻤﺎ ﺃﺳﺒﻖ ﻋﻨﺪ ﺇﻳﻘﺎﻑ ﺍﻟﺨﻼﻁ ﺃﻭ ﻋﻨﺪ‬
‫ﺗﻔﺮﻳﻎﺍﻟﻤﺎﺩﺓ ﺍﻷﻭﻟﻰ‪ .‬ﺍﺳﺘﺨﺪﻡ ﺟﻬﺎﺯ ﺗﻮﻗﻴﺖ ﻣﻨﺎﺳﺐ‪ ،‬ﺩﻗﻴﻖ ﺣﺘﻰ ‪ 1‬ﺛﺎﻧﻴﺔ‪،‬‬
‫ﺇﺟﺮﺍءﺍﺧﺘﺒﺎﺭ ﺍﻟﺮﻛﻮﺩ ﻋﻠﻰ ﻛﻞ ﻋﻴﻨﺔ ﻭﻓﻘﺎً ﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ‪A1.4.1‬‬ ‫ﻟﻘﻴﺎﺱﻭﺗﺴﺠﻴﻞ ﺍﻟﻤﺪﺓ ﺍﻟﺰﻣﻨﻴﺔ ﻟﻠﺨﻠﻂ‪.‬‬
‫‪ .C143/C143M‬ﺑﺪء ﺍﺧﺘﺒﺎﺭ ﺍﻟﺮﻛﻮﺩ ﻓﻲ ﻏﻀﻮﻥ ‪ 5‬ﺩﻗﺎﺉﻖ ﺑﻌﺪ ﺍﻟﺤﺼﻮﻝ‬
‫ﻋﻠﻰﺍﻟﻌﻴﻨﺔ‪.‬‬
‫ﺃ‪1.2.5‬ﺑﺎﻟﻨﺴﺒﺔ ﻟﺨﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ‪ ،‬ﻳﺘﻢ ﺧﻠﻂ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺑﺴﺮﻋﺔ ﺧﻠﻂ‬
‫ﺍﻟﻜﺜﺎﻓﺔ)ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻭﺍﻹﻧﺘﺎﺟﻴﺔ ‪A1.5‬‬ ‫ﺗﺰﻳﺪﻋﻦ ‪ 12‬ﺩﻭﺭﺓ ‪ /‬ﺩﻗﻴﻘﺔ ﺃﻭ ﺑﺎﻟﺴﺮﻋﺔ ﺍﻟﻤﻮﺻﻰ ﺑﻬﺎ ﻣﻦ ﻗﺒﻞ ﺍﻟﺸﺮﻛﺔ‬
‫ﺗﺤﺪﻳﺪﻛﺜﺎﻓﺔ ﻛﻞ ﻋﻴﻨﺔ ﻭﻓﻘﺎً ﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ‪.C138/C138MA1.5.1‬‬ ‫ﺍﻟﻤﺼﻨﻌﺔ‪.‬ﺧﻠﻂ ﻛﺎﻣﻞ ﺑﺎﺳﺘﺨﺪﺍﻡ ﻣﺎ ﺑﻴﻦ ‪ 70‬ﻭ ‪ 100‬ﺩﻭﺭﺓ ﻟﻸﺳﻄﻮﺍﻧﺔ‬
‫ﺍﺳﺘﺨﺪﻡﺍﻟﻤﻘﻴﺎﺱ ﻟﻘﻴﺎﺱ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﺑﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ‪/C231M‬‬ ‫ﺑﺴﺮﻋﺔﺍﻟﺨﻠﻂ‪ .‬ﻟﺘﺤﺪﻳﺪ ﺩﻭﺭﺍﺕ ﺃﺳﻄﻮﺍﻧﺔ ﺍﻟﺨﻼﻁ ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺑﺪﺍﻳﺔ‬
‫‪C231‬ﻣﺎ ﻟﻢ ﺗﺤﺘﻮﻱ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻋﻠﻰ ﺭﻛﺎﻡ ﺧﺸﻦ ﺃﻗﺼﻰ ﺣﺠﻢ ﺍﺳﻤﻲ ﺃﻛﺒﺮ‬ ‫ﺍﻟﺨﻠﻂﺑﻌﺪ ﺗﺤﻤﻴﻞ ﺟﻤﻴﻊ ﺍﻟﻤﻮﺍﺩ ﻓﻲ ﺍﻟﺨﻼﻁ‪ .‬ﺳﺠﻞ ﻋﺪﺩ ﺍﻟﺜﻮﺭﺍﺕ ﻓﻲ‬
‫ﻣﻤﺎﻫﻮ ﻣﻨﺎﺳﺐ ﻟﻬﺬﺍ ﺍﻟﻘﻴﺎﺱ‪.‬‬ ‫ﺳﺮﻋﺔﺍﻟﺨﻠﻂ‪.‬‬

‫‪:‬ﺍﺣﺴﺐﺍﻟﻜﺜﺎﻓﺔ )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻟﻜﻞ ﻋﻴﻨﺔ ﻋﻠﻰ ﺍﻟﻨﺤﻮ ﺍﻟﺘﺎﻟﻲ ‪A1.5.2‬‬ ‫ﺃ‪1.3‬ﺃﺧﺬ ﺍﻟﻌﻴﻨﺎﺕ‬
‫ﻋﻴﻨﺎﺕﻣﻨﻔﺼﻠﺔ‪ ،‬ﺗﺘﻜﻮﻥ ﻛﻞ ﻣﻨﻬﺎ ﻣﻦ ﺣﻮﺍﻟﻲ ‪ 0.1‬ﻣﺘﺮ ‪2]3A1.3.1‬‬
‫ﻡ‬ ‫ﻗﺪﻡ‪ [3‬ﻳﺠﺐ ﺃﻥ ﺗﺆﺧﺬ ﺑﻌﺪ ﺗﻔﺮﻳﻎ ﻣﺎ ﻳﻘﺮﺏ ﻣﻦ ‪ %15‬ﻭ ‪ %85‬ﻣﻦ‬
‫)ﺃ‪(1.1‬‬ ‫ﺩ‪5‬‬
‫ﺍﻟﺨﺎﻣﺲ‬ ‫ﺍﻟﺤﻤﻮﻟﺔ)ﻣﻼﺣﻈﺔ ﺃ‪ .(1.2‬ﻭﻳﺠﺐ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻫﺬﻩ ﺍﻟﻌﻴﻨﺎﺕ ﺧﻼﻝ ﻓﺘﺮﺓ‬
‫ﺯﻣﻨﻴﺔﻻ ﺗﺰﻳﺪ ﻋﻦ ‪ 15‬ﺩﻗﻴﻘﺔ‪ .‬ﻭﻳﺠﺐ ﺗﺄﻣﻴﻦ ﺍﻟﻌﻴﻨﺎﺕ ﻭﻓﻘﺎ ًﻟﻠﻤﻤﺎﺭﺳﺔ‬
‫ﺃﻳﻦ‪:‬‬
‫‪C172/C172M‬ﻭﻟﻜﻦ ﻳﺠﺐ ﺃﻥ ﺗﻈﻞ ﻣﻨﻔﺼﻠﺔ ﻟﺘﻤﺜﻴﻞ ﻧﻘﺎﻁ ﻣﺤﺪﺩﺓ ﻓﻲ‬
‫= ﺍﻟﻜﺜﺎﻓﺔﺍﻟﻤﻘﺎﺳﺔ )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ(‪ ،‬ﻛﺠﻢ‪/‬ﻡ‪]3‬ﺭﻃﻞ‪/‬ﻗﺪﻡ‪[3‬‬ ‫ﺩ‬ ‫ﺍﻟﺪﻓﻌﺔﺑﺪﻻ ًﻣﻦ ﺩﻣﺠﻬﺎ ﻟﺘﻜﻮﻳﻦ ﻋﻴﻨﺔ ﻣﺮﻛﺒﺔ‪ .‬ﻳﺠﺐ ﺃﻥ ﻳﻜﻮﻥ ﻫﻨﺎﻙ ﻋﺪﺩ‬
‫= ﺍﻟﻜﺘﻠﺔﺍﻟﺼﺎﻓﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺑﺎﻟﻤﻘﻴﺎﺱ‪ ،‬ﻛﺠﻢ ]ﺭﻃﻞ[‪ ،‬ﻭﺣﺠﻢ‬ ‫ﻡ‬ ‫ﻛﺎﻑﻣﻦ ﺍﻟﻤﻮﻇﻔﻴﻦ ﻟﻠﻘﻴﺎﻡ ﺑﺎﻟﻤﻄﻠﻮﺏ‬
‫= ﺍﻟﻤﻘﻴﺎﺱ‪،‬ﻡ‪]3‬ﻗﺪﻡ‪.[3‬‬ ‫ﺍﻟﺨﺎﻣﺲ‬

‫‪11‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﻋﻼﺝﺍﻟﻌﻴﻨﺎﺕ ﻭﻓﻘﺎ ﻟﻠﻤﻤﺎﺭﺳﺔ‪C31/C31M‬ﺑﺎﺳﺘﺜﻨﺎء ﺃﻧﻪ ﻳﺠﺐ ﻏﻤﺮ‬ ‫ﻣﻦﻣﺘﻮﺳﻂ ﺍﻟﻜﺜﺎﻓﺔ )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻟﻠﻌﻴﻨﺘﻴﻦ‪ ،‬ﺍﺣﺴﺐ ﺇﻧﺘﺎﺟﻴﺔ ﺍﻟﺪﻓﻌﺔ‬
‫ﺍﻷﺳﻄﻮﺍﻧﺎﺕﻓﻲ ﺍﻟﻤﺎء ﻣﺒﺎﺷﺮﺓ ﺑﻌﺪ ﺍﻟﺼﺐ ﻣﻊ ﺍﻟﺤﻔﺎﻅ ﻋﻠﻰ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ‬ ‫ﻭﻓﻘﺎًﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ‪.C138/C138MA1.5.3‬‬
‫ﺑﻴﻦﺣﺪﻭﺩ ﺩﺭﺟﺔ ﺍﻟﺤﺮﺍﺭﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻟﻠﻤﻌﺎﻟﺠﺔ ﺍﻷﻭﻟﻴﺔ ﻹﺟﺮﺍءﺍﺕ ﺍﻟﻤﻌﺎﻟﺠﺔ‬
‫ﺍﻟﻘﻴﺎﺳﻴﺔﻓﻲ ﺍﻟﻤﻤﺎﺭﺳﺔ ﺍﻟﻌﻤﻠﻴﺔ‪C31/C31M‬ﻷﻭﻝ ‪ 24‬ﺳﺎﻋﺔ‪ .‬ﻧﻘﻞ‬
‫ﺍﻻﺳﻄﻮﺍﻧﺎﺕﺇﻟﻰ ﻣﺮﺍﻓﻖ ﺍﻟﻤﺨﺘﺒﺮ ﺑﻌﺪ ‪ 24‬ﺳﺎﻋﺔ ﻭﻋﻼﺟﻬﺎ ﻭﻓﻘﺎ ﻹﺟﺮﺍءﺍﺕ‬ ‫ﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء ‪A1.6‬‬
‫ﺍﻟﻤﻌﺎﻟﺠﺔﺍﻟﻘﻴﺎﺳﻴﺔ ﺍﻟﻤﺘﺒﻌﺔ‪.C31/C31M‬‬ ‫ﺃ‪1.6.1‬ﻗﻴﺎﺱ ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻜﻞ ﻋﻴﻨﺔ ﻭﻓﻘﺎً ﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ‪/C231M‬‬
‫‪ .C231‬ﺍﺳﺘﺨﺪﺍﻡ ﻃﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ‪C173/C173M‬ﺇﺫﺍ ﻛﺎﻧﺖ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﻣﺼﻨﻮﻋﺔﻣﻦ ﺭﻛﺎﻡ ﺧﻔﻴﻒ ﺍﻟﻮﺯﻥ ﺃﻭ ﺇﺫﺍ ﻛﺎﻥ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﻓﻲ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﻳﺤﺘﻮﻱﻋﻠﻰ ﻋﺎﻣﻞ ﺗﺼﺤﻴﺢ ﻟﻠﺮﻛﺎﻡ ﺃﻛﺒﺮ ﻣﻦ ‪ ٪0.5‬ﻋﻨﺪ ﺗﺤﺪﻳﺪﻩ ﻭﻓﻘﺎً‬
‫ﺍﺧﺘﺒﺎﺭﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﻭﻓﻘﺎً ﻟﻄﺮﻳﻘﺔ ﺍﻻﺧﺘﺒﺎﺭ ‪C39/C39M A1.9.2‬ﻓﻲ‬ ‫ﻟﻄﺮﻳﻘﺔﺍﻻﺧﺘﺒﺎﺭ‪.C231/C231M‬‬
‫ﻋﻤﺮﺳﺒﻌﺔ ﺃﻳﺎﻡ‪ .‬ﺇﺫﺍ ﻛﺎﻧﺖ ﻗﻮﺓ ﺍﻷﺳﻄﻮﺍﻧﺔ ﺍﻟﻔﺮﺩﻳﺔ ﺗﺨﺘﻠﻒ ﻋﻦ ﻣﺘﻮﺳﻂ‬
‫ﻗﻮﺓﺃﻱ ﻣﻦ ﺍﻟﻌﻴﻨﺘﻴﻦ ﺑﺄﻛﺜﺮ ﻣﻦ ‪ ،%9.5‬ﻓﻴﻤﻜﻦ ﺗﺠﺎﻫﻞ ﻫﺬﻩ ﺍﻟﻘﻴﻤﺔ‬
‫ﻟﺘﺤﺪﻳﺪﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻌﻴﻨﺔ‪.‬‬ ‫ﺍﻟﻜﺜﺎﻓﺔﺍﻟﺨﺎﻟﻴﺔ ﻣﻦ ﺍﻟﻬﻮﺍء )ﻭﺯﻥ ﺍﻟﻮﺣﺪﺓ( ‪A1.7‬‬
‫‪:‬ﺍﺣﺴﺐﺍﻟﻜﺜﺎﻓﺔ ﺍﻟﺨﺎﻟﻴﺔ ﻣﻦ ﺍﻟﻬﻮﺍء )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻟﻜﻞ ﻋﻴﻨﺔ ﻋﻠﻰ ﺍﻟﻨﺤﻮ‬
‫ﺃ‪1.9.3‬ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﻣﻦ ﻛﻞ ﻋﻴﻨﺔ ﻭﺍﻟﺘﻌﺒﻴﺮ ﻋﻦ ﺗﻠﻚ‬ ‫ﺍﻟﺘﺎﻟﻲ‪A1.7.1‬‬
‫ﺍﻟﻘﻴﻤﺔﻛﻨﺴﺒﺔ ﻣﺉﻮﻳﺔ ﻣﻦ ﻣﺘﻮﺳﻂ ﺟﻤﻴﻊ ﺍﻷﺳﻄﻮﺍﻧﺎﺕ ﺍﻟﻤﺼﻨﻮﻋﺔ ﻣﻦ‬ ‫ﺩ‬
‫ﺗﻠﻚﺍﻟﺪﻓﻌﺔ‪ .‬ﺍﺣﺴﺐ ﺍﻟﻔﺮﻕ ﻓﻲ ﺍﻟﻘﻮﺓ ﺑﻴﻦ ﻛﻞ ﻋﻴﻨﺔ ﻛﻨﺴﺒﺔ ﻣﺉﻮﻳﺔ ﻣﻦ‬ ‫)ﺃ‪(1.2‬‬ ‫‪1003‬‬ ‫ﺍﻟﻜﺜﺎﻓﺔﺍﻟﺨﺎﻟﻴﺔ ﻣﻦ ﺍﻟﻬﻮﺍء=‬
‫‪2100‬ﺃ‬
‫ﺍﻟﻤﺘﻮﺳﻂﺍﻟﻌﺎﻡ‪.‬‬
‫ﺃﻳﻦ‪:‬‬
‫= ﺍﻟﻜﺜﺎﻓﺔﺍﻟﻤﻘﺎﺳﺔ‪ ،‬ﻛﺠﻢ‪/‬ﻡ‪]3‬ﺭﻃﻞ‪/‬ﻗﺪﻡ‪ ،[3‬ﻭﻗﻴﺎﺱ‬ ‫ﺩ‬
‫ﺗﻘﺮﻳﺮﺃ‪1.10‬‬ ‫= ﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء ﻓﻲ ﺗﻠﻚ ﺍﻟﻌﻴﻨﺔ‪.% ،‬‬ ‫ﺃ‬
‫ﺃ‪1.10.1‬ﻗﻢ ﺑﺎﻹﺑﻼﻍ ﻋﻦ ﺍﻟﻤﻌﻠﻮﻣﺎﺕ ﺍﻟﺘﺎﻟﻴﺔ‪:‬‬ ‫ﺍﻟﻤﺤﺘﻮﻯﺍﻟﻜﻠﻲ ﺍﻟﺨﺸﻦ ‪A1.8‬‬
‫ﺃ‪1.10.1.1‬ﺍﻟﻐﺮﺽ ﻣﻦ ﺍﻟﺘﻘﻴﻴﻢ‪.‬‬ ‫ﺃ‪1.8.1‬ﺗﺴﺘﺨﺪﻡ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺍﻟﻤﻘﻴﺎﺱ ﺍﻟﻤﺴﺘﺨﺪﻡ ﻟﻘﻴﺎﺱ ﺍﻟﻜﺜﺎﻓﺔ )‬
‫‪.‬ﻧﻮﻉﻭﻭﺻﻒ ﺍﻟﺨﻼﻁ ﻭﻗﺪﺭﺓ ﺍﻟﺨﻠﻂ ﺍﻟﻤﻘﺪﺭﺓ ‪A1.10.1.2‬‬ ‫ﻭﺣﺪﺓﺍﻟﻮﺯﻥ( ﻟﺘﺤﺪﻳﺪ ﻣﺤﺘﻮﻯ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ‪ .‬ﺇﺫﺍ ﺗﻢ ﺍﺳﺘﺨﺪﺍﻡ ﺟﺰء‬
‫ﻣﻨﻔﺼﻞﻣﻦ ﺍﻟﻌﻴﻨﺔ‪ ،‬ﻓﻴﺠﺐ ﺃﻥ ﻻ ﻳﻘﻞ ﻭﺯﻥ ﺍﻟﻌﻴﻨﺔ ﺍﻟﺨﺮﺳﺎﻧﻴﺔ ﻋﻦ ‪15‬‬
‫ﺃ‪1.10.1.3‬ﻧﺴﺐ ﺍﻟﺨﻠﻴﻂ ﺍﻟﺨﺮﺳﺎﻧﻲ ﻭﻛﻤﻴﺎﺕ ﺍﻟﺪﻓﻌﺔ ﻭﺍﻟﻜﺜﺎﻓﺔ )ﻭﺣﺪﺓ‬ ‫ﻛﺠﻢ]‪ 35‬ﺭﻃﻼ[ً‪ .‬ﺿﻊ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻓﻲ ﺣﺎﻭﻳﺔ ﺫﺍﺕ ﺣﺠﻢ ﻣﻨﺎﺳﺐ ﻭﺣﺪﺩ‬
‫ﺍﻟﻮﺯﻥ( ﻭﺇﻧﺘﺎﺟﻴﺔ ﺍﻟﺪﻓﻌﺔ‪.‬‬ ‫ﺍﻟﻜﺘﻠﺔﺍﻟﺼﺎﻓﻴﺔ ﻟﻠﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‪.‬‬
‫ﺃ‪1.10.1.4‬ﻣﺪﺓ ﺍﻟﺨﻠﻂ ﻟﻠﺨﻼﻃﺎﺕ ﺍﻟﺜﺎﺑﺘﺔ ﺃﻭ ﻋﺪﺩ ﺍﻟﻠﻔﺎﺕ ﻓﻲ ﺳﺮﻋﺔ‬
‫ﺍﻟﺨﻠﻂﻟﺨﻼﻃﺎﺕ ﺍﻟﺸﺎﺣﻨﺎﺕ‪.‬‬ ‫ﺃ‪1.8.2‬ﺍﻏﺴﻞ ﻛﻞ ﻋﻴﻨﺔ ﻓﻮﻕ ﻣﻨﺨﻞ ﻣﻘﺎﺱ ‪ 4.75‬ﻣﻢ )ﺭﻗﻢ ‪ (4‬ﺑﺪﺭﺟﺔ‬
‫‪.‬ﻫﺒﻮﻁﻛﻞ ﻋﻴﻨﺔ ﻭﺍﻟﻔﺮﻕ ﺑﻴﻦ ﺍﻟﻌﻴﻨﺎﺕ‪ ،‬ﻣﻢ ]ﺑﻮﺻﺔ[ ‪A1.10.1.5‬‬ ‫ﻛﺎﻓﻴﺔﻹﺯﺍﻟﺔ ﺍﻷﺳﻤﻨﺖ ﻭﻣﻌﻈﻢ ﺍﻟﺮﻛﺎﻡ ﺍﻟﻨﺎﻋﻢ‪ .‬ﺗﺤﺪﻳﺪ ﻛﺘﻠﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ‬
‫ﺍﻟﺮﻃﺐ‪،‬ﻭﺗﺨﺰﻳﻨﻪ ﻓﻲ ﻛﻴﺲ ﻣﻦ ﺍﻟﺒﻼﺳﺘﻴﻚ ﻭﻧﻘﻠﻪ ﺇﻟﻰ ﻣﻨﺸﺄﺓ ﺍﻟﻤﺨﺘﺒﺮ‪.‬‬
‫ﺃ‪1.10.1.6‬ﻣﺤﺘﻮﻯ ﺍﻟﻬﻮﺍء ﻟﻜﻞ ﻋﻴﻨﺔ ﻭﺍﻟﻔﺮﻕ ﺑﻴﻦ ﺍﻟﻌﻴﻨﺎﺕ‪.% ،‬‬ ‫ﺟﻔﻒﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﻓﻲ ﻓﺮﻥ ﻋﻠﻰ ﺩﺭﺟﺔ ﺣﺮﺍﺭﺓ ‪ 230‬ﺩﺭﺟﺔ ﻣﺉﻮﻳﺔ ]‪110‬‬
‫ﺩﺭﺟﺔﻓﻬﺮﻧﻬﺎﻳﺖ[ ﻟﻤﺪﺓ ‪ 2 616‬ﺳﺎﻋﺔ‪ .‬ﻳﻨﺨﻞ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﻓﻮﻕ ﻣﻨﺨﻞ‬
‫ﻣﻘﺎﺱ‪ 4.75‬ﻣﻢ )ﺭﻗﻢ ‪ (4‬ﻹﺯﺍﻟﺔ ﺃﻱ ﺟﺰﻳﺉﺎﺕ ﺭﻛﺎﻡ ﺩﻗﻴﻘﺔ‪ .‬ﺗﺤﺪﻳﺪ ﻛﺘﻠﺔ‬
‫ﺍﻟﻜﺜﺎﻓﺔﺍﻟﺨﺎﻟﻴﺔ ﻣﻦ ﺍﻟﻬﻮﺍء )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ( ﻟﻜﻞ ﻋﻴﻨﺔ ﻭﺍﻟﻔﺮﻕ ﺑﻴﻦ‬
‫ﺍﻟﺮﻛﺎﻡﺍﻟﺨﺸﻦ ﺍﻟﺠﺎﻑ ﻓﻲ ﻛﻞ ﻋﻴﻨﺔ‪.‬‬
‫ﺍﻟﻌﻴﻨﺎﺕ‪،‬ﻛﺠﻢ‪/‬ﻡ ‪]3A1.10.1.7‬ﺭﻃﻞ‪/‬ﻗﺪﻡ‪.[3‬‬
‫ﺃ‪1.10.1.8‬ﺍﻟﻤﺤﺘﻮﻯ ﺍﻟﻜﻠﻲ ﺍﻟﺨﺸﻦ ﻟﻜﻞ ﻋﻴﻨﺔ ﻭﺍﻟﻔﺮﻕ ﺑﻴﻦ ﺍﻟﻌﻴﻨﺎﺕ‪.% ،‬‬
‫ﺃ‪1.8.3‬ﻋﺒﺮ ﻋﻦ ﻛﺘﻠﺔ ﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﺍﻟﺠﺎﻑ ﻛﻨﺴﺒﺔ ﻣﺉﻮﻳﺔ ﻣﻦ ﻛﺘﻠﺔ‬
‫ﻋﻴﻨﺔﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻷﺻﻠﻴﺔ‪:‬‬
‫‪.‬ﻭﺍﻟﻨﺴﺒﺔﺍﻟﻤﺉﻮﻳﺔ ﻟﻠﻤﺘﻮﺳﻂ ﺍﻹﺟﻤﺎﻟﻲ ﻟﻜﻞ ﻋﻴﻨﺔ ﻭﻧﺴﺒﺔ ﺍﻟﻔﺮﻕ ﺑﻴﻦ‬
‫ﺍﻟﻌﻴﻨﺎﺕ [‪ ]psi‬ﻣﺘﻮﺳﻂ ﺍﻟﻘﻮﺓ ﺑﺎﻵﻻﻡ ﻭﺍﻟﻜﺮﻭﺏ ﺍﻟﺬﻫﻨﻴﺔ ‪A1.10.1.9‬‬ ‫ﺝ‬
‫)ﺃ‪(1.3‬‬ ‫ﻣﺤﺘﻮﻯﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ‪1003= %‬‬
‫ﻡ‬
‫ﺃﻳﻦ‪:‬‬
‫ﻣﺘﻄﻠﺒﺎﺕﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ ‪A1.11‬‬
‫= ﻛﺘﻠﺔﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ ﺍﻟﺠﺎﻑ‪ ،‬ﻛﺠﻢ ]ﺭﻃﻞ[‪ ،‬ﻭﺍﻟﻜﺘﻠﺔ ﺍﻟﺼﺎﻓﻴﺔ‬ ‫ﺝ‬
‫ﺍﻟﺤﺪﺍﻷﻗﺼﻰ ﻟﻠﻔﺮﻕ ﺍﻟﻤﺴﻤﻮﺡ ﺑﻪ ﻟﻜﻞ ﺧﺎﺻﻴﺔ ﺗﻢ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻴﻬﺎ ﻣﻦ‬ ‫= ﻟﻨﻔﺲﻋﻴﻨﺔ ﺍﻟﺨﺮﺳﺎﻧﺔ ﺍﻟﻄﺎﺯﺟﺔ‪ ،‬ﻛﺠﻢ ]ﺭﻃﻞ[‪.‬‬ ‫ﻡ‬
‫ﺍﻟﻌﻴﻨﺘﻴﻦﺍﻟﻤﺨﺘﻠﻔﺘﻴﻦ ﻟﻨﻔﺲ ﺍﻟﺪﻓﻌﺔ ﻫﻮ ﻛﻤﺎ ﻫﻮ ﻣﻨﺼﻮﺹ ﻋﻠﻴﻪ ﻓﻲ‬
‫‪A1.11.1‬ﺍﻟﺠﺪﻭﻝ ﺃ‪ .1.1‬ﻧﺘﺎﺉﺞ ﺍﻻﺧﺘﺒﺎﺭ ﻣﻄﺎﺑﻘﺔ ﻟﺤﺪﻭﺩ ﺍﻟﺨﺼﺎﺉﺺ‬ ‫ﻗﻮﺓﺍﻟﻀﻐﻂ ‪A1.9‬‬
‫ﺍﻟﺨﻤﺴﺔﺍﻟﻤﺬﻛﻮﺭﺓ ﻓﻲﺍﻟﺠﺪﻭﻝ ﺃ‪1.1‬ﻳﺠﺐ ﺃﻥ ﺗﺸﻴﺮ ﺇﻟﻰ ﺧﺮﺳﺎﻧﺔ ﻣﻮﺣﺪﺓ‬ ‫ﺃ‪1.9.1‬ﻳﺼﻨﻊ ﻋﻠﻰ ﺍﻷﻗﻞ ﺛﻼﺙ ﺃﺳﻄﻮﺍﻧﺎﺕ ﻣﻘﺎﺱ ‪ 300 × 150‬ﻣﻢ ]‪× 6‬‬
‫ﺿﻤﻦﺣﺪﻭﺩ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ‪.‬‬ ‫‪12‬ﺑﻮﺻﺔ[ ﺃﻭ ‪ 200 × 100‬ﻣﻢ ]‪ 8 × 4‬ﺑﻮﺻﺔ[ ﻣﻦ ﻛﻞ ﻋﻴﻨﺔ ﺧﺮﺳﺎﻧﻴﺔ‪.‬‬

‫‪12‬‬
‫ﺃ‪C94/C94M - 17‬‬
‫ﺍﻟﺠﺪﻭﻝﺃ‪ 1.1‬ﻣﺘﻄﻠﺒﺎﺕ ﺗﻮﺣﻴﺪ ﺍﻟﺨﺮﺳﺎﻧﺔ‬
‫ﺃﻗﺼﻰ‬
‫ﻣﺴﻤﻮﺡ‬ ‫ﺍﻣﺘﺤﺎﻥ‬
‫ﺍﺧﺘﻼﻑ‬
‫‪[1.0]16‬‬ ‫ﻛﺜﺎﻓﺔﺍﻟﻬﻮﺍء ﺍﻟﺨﺎﻟﻴﺔ )ﻭﺣﺪﺓ ﺍﻟﻮﺯﻥ(‪ ،‬ﻛﺠﻢ‪/‬ﻡ‪]3‬ﺭﻃﻞ‪/‬ﻗﺪﻡ‪[3‬‬
‫‪1.0‬‬ ‫ﻣﺤﺘﻮﻯﺍﻟﻬﻮﺍء‪% ،‬‬
‫ﺍﻟﺮﻛﻮﺩ‪،‬ﻣﻢ ]ﺑﻮﺻﺔ[‪:‬‬
‫‪[1.0]25‬‬ ‫ﺇﺫﺍﻛﺎﻥ ﻣﺘﻮﺳﻂ ﺍﻻﻧﺤﺪﺍﺭ ﺃﻗﻞ ﻣﻦ ‪ 100‬ﻣﻢ ]‪ 4‬ﺑﻮﺻﺔ[ ﺇﺫﺍ‬
‫‪[1.5]40‬‬ ‫ﻛﺎﻥﻣﺘﻮﺳﻂ ﺍﻻﻧﺤﺪﺍﺭ ‪ 100‬ﺇﻟﻰ ‪ 150‬ﻣﻢ ]‪ 4‬ﺇﻟﻰ ‪ 6‬ﺑﻮﺻﺔ[‬
‫‪6.0‬‬ ‫ﻣﺤﺘﻮﻯﺍﻟﺮﻛﺎﻡ ﺍﻟﺨﺸﻦ‪% ،‬‬
‫ﻣﺘﻮﺳﻂﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻋﻨﺪ ‪ 7‬ﺃﻳﺎﻡ ﻟﻜﻞ ﻋﻴﻨﺔ‪،‬ﺃ‪%‬‬
‫‪7.5‬ﺃ‬

‫ﺃﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻰ ﺍﻟﺨﻼﻁ ﻣﺒﺪﺉﻴﺔ‪ ،‬ﻓﻲ ﺍﻧﺘﻈﺎﺭ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭﺍﺕ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻟﻤﺪﺓ ‪ 7‬ﺃﻳﺎﻡ‪.‬‬

‫ﺯﺍﺉﺪﺓ‬

‫)ﻣﻌﻠﻮﻣﺎﺕ ﻏﻴﺮ ﺇﻟﺰﺍﻣﻴﺔ(‬

‫) ﺣﺴﺎﺏ ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ‪'FX1.‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ(‬


‫ﺿﺮﻭﺭﻱﻟﺘﻠﺒﻴﺔ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﻮﺓ‪18.4‬‬

‫ﻳﺘﻄﻠﺐﺍﻟﺠﺪﻭﻝ ‪ X1.2‬ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻋﻨﺪ ﺍﻟﺒﻴﺎﻧﺎﺕ‬ ‫ﻗﺴﻢ‪18.4X1.1‬ﺗﺤﺘﻮﻱ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻋﻠﻰ ﻧﻔﺲ ﻣﺘﻄﻠﺒﺎﺕ ﺍﻟﻘﻮﺓ‬
‫ﻏﻴﺮﻣﺘﻮﻓﺮﺓ ﻹﻧﺸﺎء ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ‬ ‫ﻛﺘﻠﻚﺍﻟﻮﺍﺭﺩﺓ ﻓﻲ ‪ ACI 318‬ﻭ‪ ،ACI 301‬ﺑﺎﺳﺘﺜﻨﺎء ﺃﻧﻬﺎ ﻻ ﺗﺘﻄﻠﺐ ﺗﻘﺪﻳﻢ‬
‫‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‬ ‫ﻣﺘﻮﺳﻂﺍﻟﻘﻮﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ‪'،‬‬ ‫ﺍﻟﻘﻮﺓﺍﻟﻤﺤﺪﺩﺓ‪،‬‬ ‫ﺍﻟﺒﻴﺎﻧﺎﺕﻭﺣﺴﺎﺏ ﻣﺘﻮﺳﻂ ﺍﻟﻘﻮﺓ‪F '،‬ﺳﺠﻞ ﺗﺠﺎﺭﻱﺍﻟﻼﺯﻣﺔ ﻟﺘﻠﺒﻴﺔ ﺗﻠﻚ‬
‫ﺍﻟﻤﺘﻄﻠﺒﺎﺕ‪.‬ﻻ ﻳﺘﻀﻤﻦ ﻫﺬﺍ ﺍﻟﻤﻠﺤﻖ ﺟﻤﻴﻊ ﺍﻟﻤﺘﻄﻠﺒﺎﺕ ﺍﻟﺘﻔﺼﻴﻠﻴﺔ ﻟﻘﺎﻧﻮﻥ‬
‫ﺭﻃﻞﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬ ‫]ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ[‬ ‫' ‪F‬ﺝ‪ ،‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‬

‫' ‪F‬ﺝ‪1000+‬‬ ‫]' ‪F‬ﺝ‪[7.0+‬‬ ‫> ‪[3000] 21‬‬


‫' ‪F‬ﺝ‪1200+‬‬ ‫]' ‪F‬ﺝ‪[8.3+‬‬ ‫‪21‬ﺇﻟﻰ ‪ 3000] 35‬ﺇﻟﻰ ‪[5000‬‬ ‫ﻭﻣﻮﺍﺻﻔﺎﺕ‪ ACI‬ﺍﻟﺘﻲ ﺳﺘﺤﻜﻢ ﺍﻟﺘﻘﺪﻳﻢ ﻟﻸﻏﺮﺍﺽ ﺍﻟﺨﺎﺻﺔ ﺑﻬﺎ‪ .‬ﺗﻬﺪﻑ‬
‫‪F '1.10‬ﺝ‪700+‬‬ ‫]‪F '1.10‬ﺝ‪[5.0+‬‬ ‫< ‪[5000] 35‬‬ ‫ﺍﻟﻤﻮﺍﺩﺍﻟﺘﺎﻟﻴﺔ ﺇﻟﻰ ﺇﺭﺷﺎﺩ ﻣﺴﺘﺨﺪﻣﻲ ﻫﺬﻩ ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﻋﻨﺪﻣﺎ ﻻ ﻳﻜﻮﻥ‬
‫ﻫﻨﺎﻙﺣﺎﺟﺔ ﺇﻟﻰ ﺗﻘﺪﻳﻢ ﺭﺳﻤﻲ‪.‬‬

‫ﻧﺸﻮﺉﻬﺎﺑﻴﻦ ‪ 1.16‬ﻟﻤﺪﺓ ‪ 15‬ﺍﺧﺘﺒﺎﺭﺍ ﻭ ‪ 1.00‬ﻟﻤﺪﺓ ‪ 30‬ﺍﺧﺘﺒﺎﺭﺍ‪ .‬ﻭﻳﻨﺒﻐﻲ‬


‫ﺍﻟﺤﺼﻮﻝﻋﻠﻰ ﺳﺠﻞ ﺍﻻﺧﺘﺒﺎﺭ ﻣﻦ ﺧﻠﻴﻂ ﻣﻤﺎﺛﻞ ﺑﻘﻮﺓ ﻣﺤﺪﺩﺓ ﺿﻤﻦ ‪7‬‬ ‫‪X1.1.1‬ﺍﻟﺠﺪﻭﻝ ‪X1.1‬ﻳﻮﻓﺮ ﺍﻟﺼﻴﻎ ﺍﻹﺣﺼﺎﺉﻴﺔ ﻟﺤﺴﺎﺏ ﻣﺘﻮﺳﻂ‬
‫ﻣﻴﺠﺎﺑﺎﺳﻜﺎﻝ ]‪ 1000‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[ ﻣﻦ ﺍﻟﻘﻮﺓ ﺍﻟﻤﺤﺪﺩﺓ‬ ‫ﺍﻟﻘﻮﺓﺍﻟﻤﻄﻠﻮﺑﺔ' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱﻋﻨﺪﻣﺎ ﺗﺘﻮﻓﺮ ﺳﺠﻼﺕ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ ﻣﻦ‬
‫ﻟﻠﻤﺸﺮﻭﻉﺍﻟﺠﺪﻳﺪ ﺍﻟﺬﻱ ﻳﺘﻢ ﺗﺤﺪﻳﺪ ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻟﻪ‪ .‬ﺗﺮﺗﺒﻂ‬ ‫ﺍﻟﻤﺸﺎﺭﻳﻊﺍﻟﺴﺎﺑﻘﺔ‪ .‬ﻳﺘﻢ ﺍﺳﺘﺨﺪﺍﻡ ﻧﺘﺎﺉﺞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ ﻟﺘﺤﺪﻳﺪ ﺍﻻﻧﺤﺮﺍﻑ‬
‫ﺍﻟﻤﻌﺎﺩﻻﺕﺑﻤﻌﺎﻳﻴﺮ ﻗﺒﻮﻝ ﺍﻟﻘﻮﺓ ﻓﻲ‪18.4‬ﻭﺗﺤﺪﻳﺪ ﻓﺮﺻﺔ ﺃﻗﻞ ﻣﻦ ‪٪1‬‬ ‫ﺍﻟﻤﻌﻴﺎﺭﻱ‪،‬ﺱ‪ .‬ﻣﻄﻠﻮﺏ ﻣﺎ ﻻ ﻳﻘﻞ ﻋﻦ ‪ 30‬ﻧﺘﻴﺠﺔ ﺍﺧﺘﺒﺎﺭ ﻣﺘﺘﺎﻟﻴﺔ ﻟﻠﺤﺼﻮﻝ‬
‫ﻟﻠﻔﺸﻞﻓﻲ ﻫﺬﻩ ﺍﻟﻤﻌﺎﻳﻴﺮ ﺇﺫﺍ ﺗﻢ ﺇﻧﺘﺎﺝ ﺍﻟﺨﺮﺳﺎﻧﺔ ﻟﺘﺤﻘﻴﻖ ﻣﺘﻮﺳﻂ ﺍﻟﻘﻮﺓ‬ ‫ﻋﻠﻰﺗﻘﺪﻳﺮ ﻗﻮﻱ ﻟﻼﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ‪ .‬ﺇﺫﺍ ﻛﺎﻥ ﻋﺪﺩ ﺍﻻﺧﺘﺒﺎﺭﺍﺕ ﺑﻴﻦ ‪15‬‬
‫ﺍﻟﻤﻄﻠﻮﺑﺔﺑﻨﻔﺲ ﺩﺭﺟﺔ ﺍﻟﺘﺒﺎﻳﻦ ﺍﻟﺘﻲ ﻳﺸﻴﺮ ﺇﻟﻴﻬﺎ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ‬ ‫ﻭ‪،30‬ﻳﺘﻢ ﺿﺮﺏ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ ﺍﻟﻤﺤﺴﻮﺏ ﺑﻌﺎﻣﻞ ﻟﻠﺴﻤﺎﺡ ﺑﻌﺪﻡ‬
‫ﺍﻟﻤﺴﺘﺨﺪﻡ‪.‬ﻷﻥ ﺍﻟﻘﻮﺓ ﻣﺘﻮﺳﻄﺔ' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‪ ،‬ﻳﺠﺐ ﺃﻥ ﺗﻜﻮﻥ ﻋﺎﻟﻴﺔ ﺑﻤﺎ‬ ‫ﺍﻟﻴﻘﻴﻦﺑﺸﺄﻥ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ ﺍﻟﻤﻘﺪﺭ‪ .‬ﺍﻟﻌﺎﻣﻞ ﻫﻮ ﺍﻻﺳﺘﻴﻔﺎء ﺍﻟﺨﻄﻲ‬
‫ﻳﻜﻔﻲﻟﺘﺘﻮﺍﻓﻖ ﻣﻊ ﻣﺘﻮﺳﻄﺎﺕ ﻧﺘﺎﺉﺞ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﺜﻼﺛﺔ ﺍﻟﻤﺘﺘﺎﻟﻴﺔ‬
‫ﻭﻣﺘﻄﻠﺒﺎﺕﺍﻟﺤﺪ ﺍﻷﺩﻧﻰ ﻣﻦ ﻗﻮﺓ ﻧﺘﻴﺠﺔ ﺍﻻﺧﺘﺒﺎﺭ ﺍﻟﻔﺮﺩﻳﺔ‪ ،‬ﻭﺃﻋﻠﻰ ﻣﺘﻮﺳﻂ‬
‫ﻗﻮﺓ)' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ( ﻳﺤﺪﺩ ﻣﻦ ﻫﺎﺗﻴﻦ ﺍﻟﻤﻌﺎﺩﻟﺘﻴﻦ ﻳﺤﻜﻢ‪ .‬ﺗﺘﻮﻓﺮ ﺇﺭﺷﺎﺩﺍﺕ‬
‫ﺃﻛﺜﺮﺗﻔﺼﻴﻼ ًﺣﻮﻝ ﻫﺬﺍ ﺍﻟﻤﻮﺿﻮﻉ ﻓﻲ ‪6.ACI 214R‬‬ ‫ﻳﺘﻄﻠﺐﺍﻟﺠﺪﻭﻝ ‪ X1.1‬ﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﻋﻨﺪ ﺍﻟﺒﻴﺎﻧﺎﺕ‬
‫ﻣﺘﺎﺣﺔﻟﺘﺤﺪﻳﺪ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ‬
‫ﻣﺘﻮﺳﻂﺍﻟﻘﻮﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ‪F '،‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‬ ‫‪F‬ﺝ‬ ‫ﺍﻟﻘﻮﺓﺍﻟﻤﺤﺪﺩﺓ‪'،‬‬
‫ﺍﺳﺘﺨﺪﻡﺍﻷﻛﺒﺮ ﻣﻦ ﺍﻟﻤﻌﺎﺩﻟﺔ ‪ X1.1‬ﻭ[‪:X1.2 ]X1.2M‬‬ ‫‪#‬‬
‫‪35‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‪ 5000‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‬

‫(‪)X1.1‬‬ ‫' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ=' ‪F‬ﺝ‪1.34+‬ﺳﺎﺩﺱ '‬

‫ﺇﺫﺍﻛﺎﻥ ﺧﻠﻴﻄﺎً ﺟﺪﻳﺪﺍً ﺃﻭ ﻣﺴﺘﻮﻯ ﻗﻮﺓ ﻭﻟﻢ ﻳﻜﻦ ﺳﺠﻞ ﺍﺧﺘﺒﺎﺭ ﺍﻟﻘﻮﺓ‬ ‫(‪)X1.2‬‬ ‫ﺳﺠﻞ‬ ‫ﺳﺠﻞﺗﺠﺎﺭﻱ=' ‪F‬ﺝ‪2.33+‬ﺱ‪F '] 500-‬‬

‫ﻣﺘﺎﺣﺎًﻟﺘﺤﺪﻳﺪ ﺍﻻﻧﺤﺮﺍﻑ ﺍﻟﻤﻌﻴﺎﺭﻱ‪ ،‬ﻓﻌﻨﺪﺉﺬ ٍ‪X1.1.2‬ﺍﻟﺠﺪﻭﻝ ‪X1.2‬ﻳﻮﻓﺮ‬


‫[‪]X1.2M‬‬ ‫ﺗﺠﺎﺭﻱ=' ‪F‬ﺝ‪2.33+‬ﺱ‪[3.5-‬‬
‫ﺍﺳﺘﺨﺪﻡﺍﻷﻛﺒﺮ ﻣﻦ ‪ Eq X1.1‬ﻭ‪:X1.3‬‬
‫ﻣﺴﺘﻮﻳﺎﺕﺍﻓﺘﺮﺍﺿﻴﺔ ﻟﻠﻘﻮﺓ ﻓﻲ ﺍﻟﺘﺼﻤﻴﻢ ﺍﻟﺰﺍﺉﺪ‪.‬‬
‫< ‪ 35‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ ]‪ 5000‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ[‬

‫(‪)X1.1‬‬ ‫' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ=' ‪F‬ﺝ‪1.34+‬ﺳﺎﺩﺱ '‬


‫(‪)X1.3‬‬ ‫ﺳﺠﻞﺗﺠﺎﺭﻱ=‪F '0.90‬ﺝ‪2.33+‬ﺱ‬

‫‪X1.1.3‬ﺍﻟﺠﺪﻭﻝ ‪X1.3‬ﻳﻮﻓﺮ ﺍﻟﻘﻴﻢ ﺍﻟﻤﺤﺴﻮﺑﺔ ﻟﻠﺘﺼﻤﻴﻢ ﺍﻟﺰﺍﺉﺪ‬ ‫ﺃﻳﻦ‪:‬‬


‫ﻗﻮﺓﺍﻟﻀﻐﻂ ﺍﻟﻤﺤﺪﺩﺓ‪ ،‬ﻭﻣﺘﻮﺳﻂ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﺍﻟﻤﻄﻠﻮﺑﺔ‪،‬‬
‫ﻭﻣﺘﻮﺳﻂﺍﻟﻘﻮﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ ﻟﻼﻧﺤﺮﺍﻓﺎﺕ ﺍﻟﻤﻌﻴﺎﺭﻳﺔ ﺍﻟﻤﺤﺪﺩﺓ ﻭﻣﺴﺘﻮﻳﺎﺕ‬ ‫ﻭﺍﻻﻧﺤﺮﺍﻑﺍﻟﻤﻌﻴﺎﺭﻱ‪.‬‬
‫=‬
‫=‬
‫' ‪F‬ﺝ‬

‫ﺍﻟﻘﻮﺓﺍﻟﻤﺤﺪﺩﺓ ﺍﻟﺘﻲ ﻳﻤﻜﻦ ﺍﻋﺘﺒﺎﺭﻫﺎ ﻧﻤﻮﺫﺟﻴﺔ‪ .‬ﻳﺘﻢ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻗﻴﻢ ﺃﻛﺜﺮ‬
‫‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‬ ‫'‬

‫=‬ ‫ﺱ‬
‫ﺩﻗﺔﻣﻦ‪.X1.1.2‬‬

‫‪13‬‬
‫ﺍﻟﺠﺪﻭﻝ‪ X1.3‬ﺍﻟﺘﺼﻤﻴﻢ ﺍﻟﺰﺍﺉﺪ ﺿﺮﻭﺭﻱ ﻟﻠﺘﻮﺍﻓﻖ ﻣﻊ ﻗﻮﺓ ﺍﻟﻀﻐﻂ ﺍﻟﻤﺤﺪﺩﺓ‬
‫ﻭﺣﺪﺍﺕ‪SI‬‬ ‫ﺍﻟﺘﺼﻤﻴﻢﺍﻟﺰﺍﺉﺪ ﻣﻄﻠﻮﺏ‬ ‫ﻭﺣﺪﺍﺕﺑﻮﺻﺔ‪-‬ﺭﻃﻞ‬
‫ﻻﻳﻮﺟﺪﺑﻴﺎﻧﺎﺕ‬ ‫ﺍﻻﻧﺤﺮﺍﻑﺍﻟﻤﻌﻴﺎﺭﻱ ﻋﻦ ﺳﺠﻞ ﺍﻻﺧﺘﺒﺎﺭ‪MPa ،‬‬ ‫ﻻﻳﻮﺟﺪﺑﻴﺎﻧﺎﺕ‬ ‫ﺍﻻﻧﺤﺮﺍﻑﺍﻟﻤﻌﻴﺎﺭﻱ ﻋﻦ ﺳﺠﻞ ﺍﻻﺧﺘﺒﺎﺭ‪ ،‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬ ‫ﻣﺤﺪﺩ‬
‫ﻣﺤﺪﺩ‬
‫ﻏﻴﺮﻣﻌﺮﻭﻑ ‪SD‬‬ ‫‪5.0‬‬ ‫‪4.0‬‬ ‫‪3.5‬‬ ‫‪2.5‬‬ ‫‪2.0‬‬ ‫ﻏﻴﺮﻣﻌﺮﻭﻑ ‪SD‬‬ ‫‪700‬‬ ‫‪600‬‬ ‫‪500‬‬ ‫‪400‬‬ ‫‪300‬‬ ‫ﻗﻮﺓ‪F '،‬ﺝ‪,‬‬
‫ﻗﻮﺓ‪F '،‬ﺝ‪ ,‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ‬
‫‪F‬ﺝ‬ ‫ﺍﻟﺘﺼﻤﻴﻢﺍﻟﺰﺍﺉﺪ ﺃﻋﻼﻩ'‬ ‫ﺍﻟﺘﺼﻤﻴﻢﺍﻟﺰﺍﺉﺪ ﺃﻋﻼﻩ' ‪F‬ﺝ‬ ‫ﺭﻃﻞﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬

‫‪7.0‬‬ ‫>‪21‬‬ ‫‪1000‬‬ ‫>‪3000‬‬


‫‪8.3‬‬ ‫‪8.2‬‬ ‫‪5.8‬‬ ‫‪4.7‬‬ ‫‪3.4‬‬ ‫‪2.7‬‬ ‫‪20‬‬ ‫‪1200‬‬ ‫‪1130‬‬ ‫‪810‬‬ ‫‪670‬‬ ‫‪540‬‬ ‫‪400‬‬ ‫‪3000‬‬
‫‪8.3‬‬ ‫‪8.2‬‬ ‫‪5.8‬‬ ‫‪4.7‬‬ ‫‪3.4‬‬ ‫‪2.7‬‬ ‫‪30‬‬ ‫‪1200‬‬ ‫‪1130‬‬ ‫‪810‬‬ ‫‪670‬‬ ‫‪540‬‬ ‫‪400‬‬ ‫‪4000‬‬
‫‪8.3‬‬ ‫‪8.2‬‬ ‫‪5.8‬‬ ‫‪4.7‬‬ ‫‪3.4‬‬ ‫‪2.7‬‬ ‫‪35‬‬ ‫‪1200‬‬ ‫‪1130‬‬ ‫‪810‬‬ ‫‪670‬‬ ‫‪540‬‬ ‫‪400‬‬ ‫‪5000‬‬

‫‪14‬‬
‫‪9.0‬‬ ‫‪7.7‬‬ ‫‪5.8‬‬ ‫‪4.7‬‬ ‫‪3.4‬‬ ‫‪2.7‬‬ ‫‪40‬‬ ‫‪1300‬‬ ‫‪1030‬‬ ‫‪800‬‬ ‫‪670‬‬ ‫‪540‬‬ ‫‪400‬‬ ‫‪6000‬‬
‫ﺍﻟﻘﻮﺓﺍﻟﻤﺘﻮﺳﻄﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ‬
‫ﻻﻳﻮﺟﺪﺑﻴﺎﻧﺎﺕ‬ ‫ﺍﻻﻧﺤﺮﺍﻑﺍﻟﻤﻌﻴﺎﺭﻱ ﻋﻦ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ‪MPa ،‬‬ ‫ﻻﻳﻮﺟﺪﺑﻴﺎﻧﺎﺕ‬ ‫ﺍﻻﻧﺤﺮﺍﻑﺍﻟﻤﻌﻴﺎﺭﻱ ﻋﻦ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻴﺪﺍﻧﻴﺔ‪ ،‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬ ‫ﻣﺤﺪﺩ‬
‫ﻣﺤﺪﺩ‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﻏﻴﺮﻣﻌﺮﻭﻑ ‪SD‬‬ ‫‪5.0‬‬ ‫‪4.0‬‬ ‫‪3.5‬‬ ‫‪2.5‬‬ ‫‪2.0‬‬ ‫ﻏﻴﺮﻣﻌﺮﻭﻑ ‪SD‬‬ ‫‪700‬‬ ‫‪600‬‬ ‫‪500‬‬ ‫‪400‬‬ ‫‪300‬‬ ‫ﻗﻮﺓ‪F '،‬ﺝ‪,‬‬
‫ﻗﻮﺓ‪F '،‬ﺝ‪ ,‬ﻣﻴﺠﺎ ﺑﺎﺳﻜﺎﻝ‬
‫' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‪ ،‬ﺍﻟﻘﻮﺓ ﺍﻟﻤﺘﻮﺳﻄﺔ ﺍﻟﻤﻄﻠﻮﺑﺔ‪MPa ،‬‬ ‫' ‪F‬ﺳﺠﻞ ﺗﺠﺎﺭﻱ‪ ،‬ﻣﺘﻮﺳﻂ ﺍﻟﻘﻮﺓ ﺍﻟﻤﻄﻠﻮﺑﺔ‪ ،‬ﺭﻃﻞ ﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬ ‫ﺭﻃﻞﻟﻜﻞ ﺑﻮﺻﺔ ﻣﺮﺑﻌﺔ‬

‫' ‪F‬ﺝ‪7.0+‬‬ ‫>‪21‬‬ ‫' ‪F‬ﺝ‪1000+‬‬ ‫>‪3000‬‬


‫‪28.3‬‬ ‫‪28.2‬‬ ‫‪25.8‬‬ ‫‪24.7‬‬ ‫‪23.4‬‬ ‫‪22.7‬‬ ‫‪20‬‬ ‫‪4200‬‬ ‫‪4130‬‬ ‫‪3810‬‬ ‫‪3670‬‬ ‫‪3540‬‬ ‫‪3400‬‬ ‫‪3000‬‬
‫‪38.3‬‬ ‫‪38.2‬‬ ‫‪35.8‬‬ ‫‪34.7‬‬ ‫‪33.4‬‬ ‫‪32.7‬‬ ‫‪30‬‬ ‫‪5200‬‬ ‫‪5130‬‬ ‫‪4810‬‬ ‫‪4670‬‬ ‫‪4540‬‬ ‫‪4400‬‬ ‫‪4000‬‬
‫‪43.3‬‬ ‫‪43.2‬‬ ‫‪40.8‬‬ ‫‪39.7‬‬ ‫‪38.4‬‬ ‫‪37.7‬‬ ‫‪35‬‬ ‫‪6200‬‬ ‫‪6130‬‬ ‫‪5810‬‬ ‫‪5670‬‬ ‫‪5540‬‬ ‫‪5400‬‬ ‫‪5000‬‬
‫‪49.0‬‬ ‫‪47.7‬‬ ‫‪45.8‬‬ ‫‪44.7‬‬ ‫‪43.4‬‬ ‫‪42.7‬‬ ‫‪40‬‬ ‫‪7300‬‬ ‫‪7030‬‬ ‫‪6800‬‬ ‫‪6670‬‬ ‫‪6540‬‬ ‫‪6400‬‬ ‫‪6000‬‬
‫ﺃ‪C94/C94M - 17‬‬

‫ﻣﻠﺨﺺﺍﻟﺘﻐﻴﺮﺍﺕ‬

‫ﺣﺪﺩﺕﺍﻟﻠﺠﻨﺔ ‪ C09‬ﻣﻮﻗﻊ ﺍﻟﺘﻐﻴﻴﺮﺍﺕ ﺍﻟﻤﺤﺪﺩﺓ ﻋﻠﻰ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﻣﻨﺬ ﺍﻹﺻﺪﺍﺭ ﺍﻷﺧﻴﺮ )‪ (C94/C94M – 17‬ﻭﺍﻟﺘﻲ ﻗﺪ ﺗﺆﺛﺮ ﻋﻠﻰ‬
‫ﺍﺳﺘﺨﺪﺍﻡﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ‪) .‬ﺗﻤﺖ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻴﻪ ﻓﻲ ‪ 1‬ﺃﻏﺴﻄﺲ ‪(.2017‬‬

‫)‪(3‬ﺗﻤﺖ ﺇﺿﺎﻓﺔ ﻣﻼﺣﻈﺔ ‪ 5‬ﺟﺪﻳﺪﺓ ﻭﺇﻋﺎﺩﺓ ﺗﺮﻗﻴﻢ ﺍﻟﻤﻼﺣﻈﺎﺕ ﺍﻟﻼﺣﻘﺔ‬ ‫)‪(1‬ﺍﻟﻤﻮﺍﺻﻔﺎﺕ ﺍﻟﻤﻀﺎﻓﺔ‪C1798/C1798M‬ﺇﻟﻰ ﻗﺎﺉﻤﺔ ﺍﻟﻮﺛﺎﺉﻖ‬
‫ﻭﻓﻘﺎًﻟﺬﻟﻚ‪.‬‬ ‫ﺍﻟﻤﺮﺟﻌﻴﺔ‪ ASTM‬ﻓﻲ ‪.2.1‬‬
‫)‪(2‬ﺗﻤﺖ ﺍﻹﺿﺎﻓﺔ ‪.6.9 ،5.7‬‬

‫ﺣﺪﺩﺕﺍﻟﻠﺠﻨﺔ ‪ C09‬ﻣﻮﻗﻊ ﺍﻟﺘﻐﻴﻴﺮﺍﺕ ﺍﻟﻤﺤﺪﺩﺓ ﻋﻠﻰ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﻣﻨﺬ ﺍﻹﺻﺪﺍﺭ ﺍﻷﺧﻴﺮ )‪ (C94/C94M–16b‬ﻭﺍﻟﺘﻲ ﻗﺪ ﺗﺆﺛﺮ ﻋﻠﻰ‬
‫ﺍﺳﺘﺨﺪﺍﻡﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ‪) .‬ﺗﻤﺖ ﺍﻟﻤﻮﺍﻓﻘﺔ ﻋﻠﻴﻪ ﻓﻲ ‪ 1‬ﻣﺎﺭﺱ ‪(.2017‬‬

‫)‪(4‬ﻣﺮﺍﺟﻌﺔ ﻭﺍﺳﻌﺔ ﺍﻟﻨﻄﺎﻕ ﻝﺍﻟﻤﻠﺤﻖ ﺃ‪.1‬‬ ‫)‪(1‬ﺗﻤﺖ ﺍﻹﺿﺎﻓﺔ‪.7.1.1.1‬‬


‫)‪(5‬ﻣﺮُﺍﺟﻊﺍﻟﻤﻼﺣﻈﺔ ‪.27‬‬ ‫)‪(2‬ﻣﺮُﺍﺟﻊ‪9.2.2 - 9.2‬ﻭﻣﻼﺣﻈﺔ ‪.13‬‬
‫)‪(3‬ﻣﺮُﺍﺟﻊ‪ ،12.5,12.4,12.3.2,11.6-11.2‬ﻭ‪.13.4-13.1‬‬

‫ﻻﺗﺘﺨﺬ ‪ ASTM International‬ﺃﻱ ﻣﻮﻗﻒ ﻓﻴﻤﺎ ﻳﺘﻌﻠﻖ ﺑﺼﻼﺣﻴﺔ ﺃﻱ ﺣﻘﻮﻕ ﺑﺮﺍءﺓ ﺍﺧﺘﺮﺍﻉ ﻣﺆﻛﺪﺓ ﻓﻴﻤﺎ ﻳﺘﻌﻠﻖ ﺑﺄﻱ ﺑﻨﺪ ﻣﺬﻛﻮﺭ ﻓﻲ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ‪ .‬ﻳﻨُﺼﺢ‬
‫ﻣﺴﺘﺨﺪﻣﻮﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺻﺮﺍﺣﺔ ًﺑﺄﻥ ﺗﺤﺪﻳﺪ ﺻﺤﺔ ﺃﻱ ﻣﻦ ﺣﻘﻮﻕ ﺑﺮﺍءﺍﺕ ﺍﻻﺧﺘﺮﺍﻉ ﻫﺬﻩ‪ ،‬ﻭﺧﻄﺮ ﺍﻧﺘﻬﺎﻙ ﻫﺬﻩ ﺍﻟﺤﻘﻮﻕ‪ ،‬ﻳﻘﻊ ﻋﻠﻰ ﻋﺎﺗﻘﻬﻢ ﺑﺎﻟﻜﺎﻣﻞ‪.‬‬

‫ﻳﺨﻀﻊﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﻟﻠﻤﺮﺍﺟﻌﺔ ﻓﻲ ﺃﻱ ﻭﻗﺖ ﻣﻦ ﻗﺒﻞ ﺍﻟﻠﺠﻨﺔ ﺍﻟﻔﻨﻴﺔ ﺍﻟﻤﺴﺆﻭﻟﺔ ﻭﻳﺠﺐ ﻣﺮﺍﺟﻌﺘﻪ ﻛﻞ ﺧﻤﺲ ﺳﻨﻮﺍﺕ‪ ،‬ﻭﺇﺫﺍ ﻟﻢ ﻳﺘﻢ ﺗﻨﻘﻴﺤﻪ‪ ،‬ﺗﺘﻢ ﺇﻋﺎﺩﺓ ﺍﻟﻤﻮﺍﻓﻘﺔ‬
‫ﻋﻠﻴﻪﺃﻭ ﺳﺤﺒﻪ‪ .‬ﺇﻥ ﺗﻌﻠﻴﻘﺎﺗﻜﻢ ﻣﺪﻋﻮﺓ ﺇﻣﺎ ﻟﻤﺮﺍﺟﻌﺔ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﺃﻭ ﻟﻠﻤﻌﺎﻳﻴﺮ ﺍﻹﺿﺎﻓﻴﺔ ﻭﻳﻨﺒﻐﻲ ﺗﻮﺟﻴﻬﻬﺎ ﺇﻟﻰ ﺍﻟﻤﻘﺮ ﺍﻟﺮﺉﻴﺴﻲ ﺍﻟﺪﻭﻟﻲ ﻟـ ‪ .ASTM‬ﺳﺘﺤﻈﻰ‬
‫ﺗﻌﻠﻴﻘﺎﺗﻚﺑﺪﺭﺍﺳﺔ ﻣﺘﺄﻧﻴﺔ ﻓﻲ ﺍﺟﺘﻤﺎﻉ ﺍﻟﻠﺠﻨﺔ ﺍﻟﻔﻨﻴﺔ ﺍﻟﻤﺴﺆﻭﻟﺔ‪ ،‬ﻭﺍﻟﺬﻱ ﻳﻤﻜﻨﻚ ﺣﻀﻮﺭﻩ‪ .‬ﺇﺫﺍ ﺷﻌﺮﺕ ﺃﻥ ﺗﻌﻠﻴﻘﺎﺗﻚ ﻟﻢ ﺗﺤﻈﻰ ﺑﺠﻠﺴﺔ ﺍﺳﺘﻤﺎﻉ ﻋﺎﺩﻟﺔ‪ ،‬ﻓﻴﺠﺐ‬
‫ﻋﻠﻴﻚﺗﻘﺪﻳﻢ ﺁﺭﺍﺉﻚ ﺇﻟﻰ ﻟﺠﻨﺔ ﻣﻌﺎﻳﻴﺮ ‪ ،ASTM‬ﻋﻠﻰ ﺍﻟﻌﻨﻮﺍﻥ ﺍﻟﻤﻮﺿﺢ ﺃﺩﻧﺎﻩ‪.‬‬

‫ﻫﺬﺍﺍﻟﻤﻌﻴﺎﺭ ﻣﺤﻤﻲ ﺑﺤﻘﻮﻕ ﺍﻟﻄﺒﻊ ﻭﺍﻟﻨﺸﺮ ﻣﻦ ﻗﺒﻞ ‪، 100 Barr Harbor Drive، PO Box C700، West Conshohocken، PA 19428-2959‬‬
‫‪ ،ASTM International‬ﺍﻟﻮﻻﻳﺎﺕ ﺍﻟﻤﺘﺤﺪﺓ‪ .‬ﻳﻤﻜﻦ ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﻃﺒﻌﺎﺕ ﻓﺮﺩﻳﺔ )ﻧﺴﺦ ﻓﺮﺩﻳﺔ ﺃﻭ ﻣﺘﻌﺪﺩﺓ( ﻣﻦ ﻫﺬﺍ ﺍﻟﻤﻌﻴﺎﺭ ﻋﻦ ﻃﺮﻳﻖ ﺍﻻﺗﺼﺎﻝ ﺑـ ‪ ASTM‬ﻋﻠﻰ‬
‫ﺍﻟﻌﻨﻮﺍﻥﺃﻋﻼﻩ ﺃﻭ ﻋﻠﻰ ‪) 9585-832-610‬ﻫﺎﺗﻒ(‪) 9555-832-610 ،‬ﻓﺎﻛﺲ(‪ ،‬ﺃﻭ‪ -e ) service@astm.org‬ﺑﺮﻳﺪ(؛ ﺃﻭ ﻣﻦ ﺧﻼﻝ ﻣﻮﻗﻊ (‪.ASTM )www.astm.org‬‬
‫ﻳﻤﻜﻦﺃﻳﻀﺎً ﺍﻟﺤﺼﻮﻝ ﻋﻠﻰ ﺣﻘﻮﻕ ﺍﻹﺫﻥ ﺑﻨﺴﺦ ﺍﻟﻤﻌﻴﺎﺭ ﻣﻦ ﻣﺮﻛﺰ ﺗﺨﻠﻴﺺ ﺣﻘﻮﻕ ﺍﻟﻄﺒﻊ ﻭﺍﻟﻨﺸﺮ‪Drive، Danvers، MA 01923، Tel: )978( 646-2600 222 ،‬‬