Professional Documents
Culture Documents
Inclined-Retaining-Wall-RCC-Design-3m
Inclined-Retaining-Wall-RCC-Design-3m
Inclined-Retaining-Wall-RCC-Design-3m
1 Preliminary Data
i) Height of Retaining Wall h 2.69 meters
ii) Submerged Soil Density γs 26 KN/cum Dry Density of soil 18 KN/m3
iii) SBC (Assumed) qo 150 KN/sqm Density of Fully saturated soil 36 KN/m3
iv) Angle of repose Ø 15 degrees Submerged Density of soil 26 KN/m3
0.262 radians
v) Surcharge Angle Ө 0 degrees
0.000 radians
vi) Coefficient of friction µ 0.5
vii) Surcharge Load Ws 0 KN/sqm
2 Pressure Coefficients
i) Active Pressure Coefficients Ca 0.589
=(cosӨ-√(cos2Ө-cos2Ø)*cosӨ) /
(cosӨ+√(cos2Ө-cos2Ø))
ii) Passive Pressure Coefficients Cp 1.70
= (1+SinØ) / (1+SinØ)
3 Preliminary Dimensions
Proposed Adopted
i) Thickness of Stem ts min 200mm 0.275 meters
ii) Thickness of footing base slab tb = 0.08 * (h + hs) 0.22 meters 0.30 meters
iii) Length of base slab L = 1.5 * √(Ca/3) * (h + hs) 1.79 meters
4.70 meters
L = 0.6h to 0.65h 2.21 meters
iv) Extra Height of Retaining Wall due to Surcharge hs = W s/γs 0.00 meters
v) Total Height of Retaining Wall due to Surcharge Hs = h+hs 2.69 meters
vi) Extra Height of RW due to inclined back fill hi = (L-ts)* tanӨ 0.71 meters
vii) Total Height of RW due to inclined back fill Hi = h+hi 3.40 meters
Design Constants
i) Grade of concrete 20 MPa
ii) Grade of steel 500 MPa
8 Design
A) Stem
i) Beanding Moment at base of stem M = MODL + MOIL 100 KN/m
B) Base Slab
Force Lever arm from end of stem Moment
i) Force due to backfill+surcharge = (H2-tb)*(L-ts)*γs 275 (L-ts) / 2 2.21 meters 609 KNm
ii) Force due to inclined backfill = hi/2*(L-ts)*γs 41 (L-ts) / 3 1.48 meters 60 KNm
iii) Self Weight of base slab =L *tb*γconc 35 L/2 2.35 meters 83 KNm
∑Ws 351 Md 752 KNm
vi) Upward soil pressure Nup = ((qsh+qmin)/2)*(L-ts) 419 ((qsh+(2*qmin))/(qsh+qmin)) * ((L- 1.97 meters 824 KNm
Upward Pressure is greater ts)/3) Mu 824 KNm
C) Reinforcement Details
FILL