Professional Documents
Culture Documents
Stop Lamps-01-01
Stop Lamps-01-01
41 32 12 ICU-A
1 3 E15
STOP
B A LAMP
SWITCH
P.103
C.24-4
2 4 E15
A : Close with brake
pedal depressed
0.3R/B
B : Open with brake
pedal depressed
ABS EPS
P.25 18 EM21
C.20-10/ P.69
34 36 E100-AK(G3LA-A/T) 0.3R/B 21-12/ 0.3R/B 0.3R/B
23 12 E100-MB(G3LA-M/T) 22-6/23-8
34 36 E200-AK(G4LA-A/T) 16 E141(G3LA)
23 12 E200-MB(G4LA-M/T) 16 E241(G4LA)
28 29 E300-A(CNG) 9 E100-AA(G3LA-A/T) 16 E341(CNG) 16 E140(G3LA)
30 32 E400-K(D3FB) 9 E200-AA(G4LA-A/T) 16 E441(D3FB) 16 E240(G4LA) 11 M04-C
ECM/PCM ABS ESP Brake IBU
P.22/24 CONTROL CONTROL Switch P.96
C.20-1/2/4/21-1/2/4/ MODULE MODULE C.10-4
22-1/23-1 P.25
C.20-9/21-11
Stop Lamps (2) SD927-2
21 4 62 ICU-B
0.3Y/O
5 FR01
P.121
0.3Y 0.3Y 0.3Y/O 0.5Y 0.3Y/B 0.3Y/B
10 FR01
P.121
GF03 P.120 GF04 P.- GF03 P.120 GF04 P.- GF05 P.119
Stop Lamps (3) SD927-3
1 3 E15
STOP
B A LAMP
SWITCH
P.103
C.24-4
2 4 E15
A : Close with brake 0.3R/B 0.5Y 0.5Y
pedal depressed
B : Open with brake
pedal depressed A
6 EF11 GM02 P.90
To Stop Lamps P.69
(SD927-4)
ABS EPS
34 36 E100-AK(G3LA-A/T)
23 12 E100-MB(G3LA-M/T)
34 36 E200-AK(G4LA-A/T) 9 E100-AA(G3LA-A/T) 16 E141(G3LA) 16 E140(G3LA) 24 E140(G3LA)
23 12 E200-MB(G4LA-M/T) 9 E200-AA(G4LA-A/T) 16 E241(G4LA) 16 E240(G4LA) 24 E240(G4LA)
ECM/PCM ABS ESP ESP
P.22 CONTROL CONTROL HAC ESP CONTROL
C.20-1/2/4/ MODULE MODULE Signal UNIT MODULE
21-1/2/4 P.25 P.25 Out P.25
C.20-10/ C.20-9/ C.20-9/
21-12 21-11 21-11
Stop Lamps (4) SD927-4
0.5Y
0.5Y
5 FR01
P.121
0.5Y 0.5Y 0.5Y 0.5Y 0.5Y 0.5Y
10 FR01
P.121
GF03 P.120 GF04 P.- GF03 P.120 GF04 P.- GF05 P.119
Stop Lamps Service Tips (1)
Circuit Description (With BCM (ETACS))
This system informs the deceleration or stop state of the present vehicle to the
driver of rear vehicle to secure the safety using Stop Lamp and High Mounted
Stop Lamp. Stop Lamp Switch is Double Switch Type (A and B). These two
signals sends opposite values depending on the brake operation. If the brake is
not stepped on, the Stop Lamp Switch B sends the power voltage value while
the Stop Lamp Switch A sends a 0V value. On the other hand, if the brake is
stepped on, the opposite values are output. Stop Lamp Switch A is used for Stop
Lamp and also used as signal for related systems (ECM/PCM, ABS/ESP Control
Module, Integrated body control unit (IBU), IPS Control Module, etc.). While stop
lamp switch B used as signal for stop lamp switch inspection. Stop lamps circuit
Constant Power (F14 10A) → Stop Lamp Switch A "ON" (No. 3, 4) → IPS
Control Module (IPS (2CH), IPS (1CH) Control) → Stop Lamp "ON"