Fixing of Bridge Length:

1) From Hydraulic calculations:


i) Cross-sectinal area-Bed Slope Method:
Discharge Calculated: = 97.71 m3/s

Calculated Regime width for discharge of 97.71 m3/s = 47.5 m


Ref.: Cl.-6.2.1,IRC:SP:13-2004
Regime width considering a restriction of 33% = 31.8 m

2) Existing Bridge:
i) There is no existing bridge at the proposed Bridge location.

3) Bank to bank distance:


Bank to bank distance: = 70 m

4) Skew Crossing Angle: = 0°


Linear waterway required: = 31.8 m

From the above three data and also considering the suitable abutment location and site condition,the proposed
bridge has been fixed as the details given below:
Span Arrangement = RCC T Beam 16 mX 2
Type of structure = RCC. T-Girder Bridge.
Total Bridge length = 34.34 m

Fixation of formation level

For Navigation (vertical clearance) = 0.900 m


Depth of girder with deck slab = 1.675 m
Wearing course at middle = 0.075 m
Afflux = 0.05 m
FRL = H.F.L+Vertical Clearance+Depth of Superstructure+Wearing Course at deck mid
= 99.845 + 0.9 + 1.675 + 0.075+0.05 = 102.545 m