Professional Documents
Culture Documents
A_Study_on_the_Improvement_of_Connection_Method_fo
A_Study_on_the_Improvement_of_Connection_Method_fo
A_Study_on_the_Improvement_of_Connection_Method_fo
net/publication/275306946
CITATIONS READS
2 179
3 authors, including:
Sang-Joon Ma
Korea Institute of Civil Engineering and Building Technology
23 PUBLICATIONS 31 CITATIONS
SEE PROFILE
All content following this page was uploaded by Sang-Joon Ma on 20 July 2017.
1
마 상 준 Ma, Sang-Joon
2
길 후 정 Gil, Hu-Jeong
3
김 동 민 Kim, Dong-Min
Abstract
This paper introduces the improvement of connection method for segment in tunnel lining system using prestressed
steel cable and presents the results of real-scale tests. It conducted a study about the applicability and mechanical
behaviour analysis of the new method that connects segment tunnel lining using prestressed steel cable by real-scale
test. Through the research, it was found that the new method has stronger connection than conventional assembling
methods. Also, the new method can be expected to have integrated behavior and stability increase of shield tunnel lining.
It is considered that the new method is much more effective than conventional assembling methods.
요 지
본 논문에서는 현재 개발 중인 쉴드터널의 강연선 체결 방식에 대해 소개하고 두 번에 걸친 실대형 세그먼트 체결시
험 결과를 나타내었다. 실대형 세그먼트 체결시험을 통해 기존 볼트 체결 방식과 강선을 이용한 체결 방식을 비교하여
체결재로써의 강연선 적용 가능성에 대한 검토를 수행하고, 강연선 체결 방식 적용 시 세그먼트에 발생하는 체결력의
역학적 거동을 분석하였다. 연구를 통해 기존 세그먼트 체결장치와 비교하여 높은 체결력을 얻을 수 있으며, 터널
세그먼트 전체의 일체화 거동 및 구조적인 안정성 증가를 기대할 수 있음을 확인하였다. 또한, 볼트 체결 대비 강연선
체결 방식이 세그먼트 체결에 더 효과 적일 수 있으며, 강연선이 세그먼트 체결 장치로서의 적용성도 좋은 것으로
사료된다.
Keywords : Shield, Prestressed steel cable, Real-scale test, Tensile force, Assembling system
1 정회원, 한국건설기술연구원 연구위원 (Member, Research Fellow, Korea Institute of Construction Technology)
2 비회원, 한국건설기술연구원 전임연구원 (Research Specialist, Korea Institute of Construction Technology, Tel: +82-31-910-0622, Fax: +82-31-910-0561, hjgil@kict.re.kr,
교신저자)
3 정회원, 한국건설기술연구원 전임연구원 (Member, Research Specialist, Korea Institute of Construction Technology)
* 본 논문에 대한 토의를 원하는 회원은 2013년 12월 31일까지 그 내용을 학회로 보내주시기 바랍니다. 저자의 검토 내용과 함께 논문집에 게재하여 드립니다.
• Simple process
• Good appearance after completion
Pin type • Corrosion resistant
• Disadvantageous for the construction of the curve
• Difficulty of removal or demolition work after assembly
1열만 설치하게 되어 누수의 우려가 있다는 단점이 있 용하는 인장력에 대해 저항하는 역학적인 메커니즘을
다. 최근에 많이 사용되고 있는 곡볼트 방식은 볼트 체 가지고 있으며 시공시의 안전성, 구조물의 내구성, 고품
결에 필요한 이격을 줄이고 세그먼트에 볼트 정착부분 질, 공기 단축 등의 장점으로 현재 폭넓게 사용되고 있
을 만들어 체결하는 방식으로, 체결부가 볼트로 강결되 다(Ha et al., 2004; Chung et al., 2000). 프리스트레스트
어 구조적 안정성이 높고 쉴드 추진에 따른 잭 추진력에 구조물의 긴장재로 기존에는 이형 철근을 많이 사용해
대한 대응성이 좋다. 또한 세그먼트 체결 및 링체결을 왔으나 재료의 한계로 근래 들어서는 강연선을 주로 사
삽입너트와 볼트를 이용하여 조립하므로 공정이 비교 용하고 있다. 강연선을 사용하면 접합부의 배근을 간략
적 간단하다는 장점이 있으나, 경사볼트에 비해서 작업 화 할 수 있고, 연결재의 배근공정이 생략되며, 시공순
이 복잡하고 변형에 대한 허용 여유가 크며, 지수재를 서에 제약을 받지 않는 우수한 시공성을 얻을 수 있다.
외측 1열만 설치할 수밖에 없으므로 볼트 주변을 통한 또한 강연선을 체결부재로 사용할 경우 일반 철근에 비
누수 발생우려가 높은 단점이 있다. 해 연성이 크므로 구조물의 연성 거동을 기대할 수 있다
(KICT, 2012). 이에 토목 및 건축분야에서는 긴장력이
2.2 건설 재료로써의 강연선 도입된 강연선을 다양하게 사용하고 있으며 특히 교량
분야에서는 사장교, 현수교, 닐슨아치교 등 PCS 구조
건설 분야에서는 대구간을 필요로 하는 구조물이 많 물의 케이블 구조로 많이 사용되고 있다.
이 계획되고 있으며, 이에 따라 구조적 성능 향상을 위
해 건설재료에 프리스트레스를 적용해 왔다. 프리스트 2.3 세그먼트의 강선 체결 방식 개발
레스 공법은 인장저항에 취약한 구조물의 문제점을 극
복하기 위해 구조재에 긴장력을 도입하여 구조물에 작 현재 연구 중인 세그먼트의 강선 체결 방식은 강연선,
(a) Segment inserted shear key (b) Stress redistribution by sheer key
(a) Setting the mould (b) Inserting pipe that cable path (c) Concrete pouring
Segment 1 2 3 4 5 6 7 8
A 0.0 0.0 0.0 0.0 0.0 0.0 0.0 손상
Upper
B -4.8 -6.0 -5.6 -5.2 -4.8 -5.2 -5.6 -4.5
Segment1
A 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Bottom
B -7.2 -9.0 -8.3 -7.5 -8.0 -8.3 -8.5 -6.8
C -6.7 -8.4 -7.8 -7.3 -6.7 -7.3 -7.8 -6.3
Upper
D -4.8 - -6.8 -7.5 -4.5 -5.5 - -5.2
Segment2
C -6.1 -7.7 -7.0 -6.4 -6.8 -7.0 -7.2 -5.8
Bottom
D - - - - - - - -
E -6.7 - -9.5 -10.5 -6.3 -7.7 - -7.3
Upper
F -4.0 - -4.8 - - -7.3 - -6.4
Segment3
E - - - - - - - -
Bottom
F - - - - - - - -
G -5.6 - -6.7 -6.3 -9.1 -10.2 - -9.0
Upper
H 0.0 - 0.0 0.0 0.0 0.0 - 0.0
Segment4
G -4.1 - -5.5 -6.0 -8.1 -8.3 - -6.8
Bottom
H 0.0 - 0.0 0.0 0.0 0.0 - 0.0
Segment 1 2 3 4 5 6 7 8
A -8.1 -8.6 -8.6 -9.4 -9.4 -8.6 -9.5 -
Upper
B -8.0 -8.6 -8.9 -9.4 -8.7 -8.7 -8.7 -9.7
Segment1
A -8.1 -9.4 -8.7 -8.7 -9.4 -8.6 -8.6 -8.1
Bottom
B -8.3 -9.0 -8.8 -9.6 -9.6 -8.7 -8.8 -8.2
C -8.4 -8.9 -9.2 -8.7 -10.0 -9.4 -8.7 -10.6
Upper
D -8.0 - -8.6 -9.4 -8.7 -8.7 - -9.8
Segment2
C -9.4 -9.0 -9.4 -9.4 -9.8 -9.4 -9.0 -9.4
Bottom
D - - - - - - - -
E -8.3 - -9.5 -10.5 -10.1 -9.3 - -9.0
Upper
F -7.9 - -8.6 - - -8.7 - -9.4
Segment3
E - - - - - - - -
Bottom
F - - - - - - - -
G -7.9 - -8.6 -8.6 -9.1 -10.2 - -10.0
Upper
H -7.9 - -8.7 -8.7 -9.6 -8.8 - -10.1
Segment4
G -9.1 - -9.7 -10.6 -9.4 -9.5 - -9.1
Bottom
H -9.3 - -9.9 -10.8 -10.8 -10.1 - -9.2
(a) Bonding the hydrophilic waterstop and gasket (b) Specimen at the ready
(d) Simulating propulsion force (e) Damage by propulsion force (f) Data gathering
Fig. 20. Test view
볼트 체결 이후 강연선 긴장 시 증가한 수치를 살펴보 못하는 것으로 판단된다. 따라서 일련의 시공과정을 가
면, 세그먼트에 작용하는 체결력은 강연선 긴장력이 훨 정하고 모사한 다음 시험의 결과를 통해 볼트의 체결보
씬 큰 것을 확인할 수 있다. 또한, 쉴드 풀추력을 모사한 다 강연선의 체결력이 더 크며, 풀추력이 세그먼트에 재
이후 해제 하였을 때의 값은 강선을 긴장하였을 때의 하된 이후 볼트의 체결력은 거의 소산되는데 비해 강선
응력값에 비해 조금 줄어들었으나 유사한 값을 유지하 의 긴장을 이용한 체결력은 유지되는 것으로 보아, 체결
는 것을 확인할 수 있는데, 이는 반복되는 쉴드 머신의 성능면에 있어서도 강선 체결이 더 우수한 것으로 판단
추력이나 여타 진동에도 세그먼트를 체결하고 있는 강 된다.
연선의 긴장력은 유지되는 것으로 설명할 수 있다. 반 Fig. 23은 동일한 선상에 위치한 30cm 철근 응력계의
면, 강연선 긴장을 해제한 경우 세그먼트는 여전히 볼트 데이터를 나타내고 있다. Fig. 17의 계측기 설치 도면으
로 체결되어 있음에도 세그먼트 내부에 작용하는 응력 로 각 게이지의 위치를 확인할 수 있는데 Fig. 23(a)의
이 거의 ‘0’에 가까워지는 것을 볼 수 있는데, 이는 볼트 R1, R2, R3, R4는 세그먼트 가장자리에 설치한 계측기
의 경우 풀추력이 모사된 이후 체결 성능을 유지하지 의 계측값을 나타낸 것이고, Fig. 23(b)의 R5, R6, R7,
R8은 세그먼트 중심부에 설치한 계측기의 계측값이다. 강선의 긴장력을 해제한 최종 단계에서 다시 응력이 ‘0’
두 그래프 모두 90cm 철근응력계와 비슷한 변화 추이를 에 가까워 지는 것으로 보아 풀추력으로 인해 발생되는
나타내고 있는 것을 확인할 수 있다. 특히, 강선을 통한 응력이 계측기의 계측범위보다 더 크기 때문인 것으로
긴장이 이루어지는 시점인 강선긴장과 풀추력 모사의 생각해 볼 수도 있으며, 정확한 사실 여부는 이번 실험
경우 세그먼트 양 끝단에 있는 R1, R4, R5, R8의 응력이 을 통해서 확인이 불가능한 것으로 판단된다.
세그먼트 접촉면 가까이 설치된 계측기인 R2, R3, R6,
R7의 응력보다 적은 것을 확인할 수 있는데 이를 통해, 5. 결 론
강선 긴장 시 힘이 세그먼트 양끝단의 세그먼트 단부로
부터 시작하여 점점 중심부로 전달되는 역학적 메커니 본 논문에서는 강선의 인장력을 이용한 쉴드 터널의
즘을 확인할 수 있다. 새로운 체결 시스템에 대해 소개하고 두 번에 걸친 실대
Fig. 24는 Fig. 23과 동일한 방법으로 세그먼트의 가 형 세그먼트 체결시험을 통해 체결재로써의 강연선 적
장자리와 중심부에 같은 라인에 설치된 콘크리트응력 용성 검토와 함께 기존의 볼트 체결 방식과 강선 체결
계의 값을 나타내었다. 콘크리트응력계의 경우 계측기 방식 적용 시 세그먼트에 발생하는 체결력의 역학적 거
의 특성상 압축이 (+)값으로 나타내어 지며 철근응력계 동을 분석하였다. 본 연구를 통해 얻은 결과를 요약하면
와 콘크리트응력계의 계측 부호는 다르나 둘다 압축력 다음과 같다.
을 의미한다. 그래프를 살펴보면 90cm 철근응력계의 경
향과 동일하게 강선의 긴장이 이루어지는 시점에서는 (1) 기존 쉴드 터널의 세그먼트 조립에 사용되는 볼트
세그먼트 단부쪽에 위치한 C1, C4, C5, C8의 계측값이 를 이용한 연결방식은 조립부분이 차지하는 면적이
더 높게 나타난 것을 확인할 수 있다. 특히, 조립 가압 넓고, 연결부를 통한 누수 발생의 문제점을 가지고
이후 볼트 체결이 이루어 지는 시점에서는 콘크리트응 있다. 강선 체결 방식을 적용할 경우 연결부가 차지
력계에 미치는 응력이 거의 없거나 미미한 것을 확인할 하는 면적이 적어 연결부재를 통한 누수 발생 감소
수 있다. 콘크리트응력계의 계측데이터를 통해 콘크리 효과를 기대할 수 있고, 연결 부재가 경제적이므로
트 내부로 전달되는 체결력은 볼트 체결보다 강선 긴장 체결부 재료비 절감에도 크게 기여할 수 있을 것으
으로 인한 체결이 더 효과적이며, 세그먼트의 체결로 인 로 기대된다.
해 하나의 라이닝으로 형성되는 쉴드 세그먼트의 특성 (2) 강선 체결 시스템은 강연선, 유압잭, 정착장치를 이
상 볼트보다 강연선의 체결성능이 더 뛰어날 수 있을 용하여 유압잭의 압력으로 강연선에 긴장력을 주입
것으로 사료된다. 풀추력 모사 후 풀추력을 해제한 시점 함으로써 기존 세그먼트 체결장치와 비교하여 높은
에서도 콘크리트응력계의 값은 줄어들지 않는 경향을 체결력을 얻을 수 있으며, 터널 세그먼트 전체의 일
나타내고 있는데 이는 철근에 비해 콘크리트의 탄성계 체화 거동 및 일체화를 통한 구조적인 안정성 증가
수가 낮아 압축력을 여전히 유지하는 것으로 사료되나, 를 기대할 수 있다.