D6N XL Differential Steering, Electrohydraulic Implement TRACK-TYPE TRACTO...

Page 1 of 4

Cerrar SIS

Pantalla anterior

Producto: TRACK-TYPE TRACTOR


Modelo: D6N TRACK-TYPE TRACTOR LJR00369
Configuración: D6N XL Differential Steering, Electrohydraulic Implement TRACK-TYPE TRACTOR LJR00001-UP (MACHINE) POWERED BY C6.6 Engine

Localización y Solución de Problemas


D6N Track-Type Tractor
Número de medio -KENR8905-02 Fecha de publicación -01/05/2012 Fecha de actualización -09/05/2012

i03358460

MID 039 - CID 0490 - FMI 03


SMCS - 7332-038-HYL

Conditions Which Generate This Code:

Illustration 1 g01732074

Connections of the implement lockout switch

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 13/01/2020
D6N XL Differential Steering, Electrohydraulic Implement TRACK-TYPE TRACTO... Page 2 of 4

Illustration 2 g01896893

Location of the implement lockout switch

The implement lockout switch has two inputs to the ECM. The two inputs are normally open and normally closed.
During normal operation, one of the inputs is open. The other input is grounded. When a circuit is measured with a
voltmeter, an open circuit will measure approximately 8 DCV to ground and a closed circuit will measure
approximately 0 DCV to ground.

The diagnostic code is recorded when the status of both the inputs are open.

The possible causes of this diagnostic code are listed below:

• The return circuit (wire 202-BK) is open.

• The signal (wire E913-YL) is permanently open.

• The signal (wire E912-PU) is permanently open.

• The switch has failed.

• The ECM has failed. This is unlikely.

Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor
connections can often be the cause of a problem in an electrical circuit. Verify that all of the connections in the
circuit are clean and secure. If a problem with a connection is found, correct the problem and verify that this
diagnostic code is active before performing this procedure.The following test procedure may create other
diagnostic codes. Ignore these created diagnostic codes and clear the diagnostic codes when the original diagnostic
code has been corrected. Ensure that the diagnostic code of CID 0490 FMI 03 is active before performing this
procedure.

Table 1
Status of the Switch
MODE Switch Position J1-26 J1-27
wire E913-YL wire E912-PU
Locked Up Open Closed
Unlocked Down Closed Open

Test Step 1. CHECK THE GROUND CIRCUIT FOR AN OPEN.

A. Turn the disconnect switch and the keyswitch to the OFF position.

B. Disconnect the switch from the machine harness.

C. Measure the resistance between frame ground and contact 2 (wire 202-BK) at the connector for the switch.

Expected Result:

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 13/01/2020
D6N XL Differential Steering, Electrohydraulic Implement TRACK-TYPE TRACTO... Page 3 of 4

The resistance should be less than 5 ohms.

Results:

• OK - The resistance is less than 5 ohms. Proceed to Test Step 2.

• NOT OK - The resistance is greater than 5 ohms.

Repair: The return circuit (wire 202-BK) is open in the machine harness. Repair the machine harness or
replace the machine harness.

STOP

Test Step 2. CHECK THE SWITCH.

A. Check for continuity between contact 1 and contact 2 of the switch.

B. Press the switch and then release the switch. Check the continuity of the switch.

C. Check for continuity between contact 2 and contact 3 of the switch.

D. Press the switch and then release the switch. Check the switch for continuity.

Expected Result:

The continuity check agrees with Table 1.

Results:

• OK - The continuity check agrees. Proceed to Test Step 3.

• NOT OK - The continuity check does not agree. The switch has failed.

Repair: Replace the switch. Verify that the new switch corrects the diagnostic code.

STOP

Test Step 3. CHECK THE SIGNAL CIRCUITS IN THE HARNESS FOR AN OPEN.

A. Reconnect the switch to the machine harness.

B. Disconnect the J1 and J2 machine harness connectors from the ECM.

C. At the machine harness connector for the ECM, check for continuity between contact J1-26 (wire E913-YL)
and all sources of negative battery.

D. Press the switch and then release the switch. Check the switch for continuity.

E. At the machine harness connector for the ECM, check for continuity between contact J1-27 (wire E912-PU)
and all sources of negative battery.

F. Press the switch and then release the switch. Check the switch for continuity.

Expected Result:

The continuity check agrees with Table 1.

Results:

• OK - The continuity check agrees.

Repair: Check the status of the diagnostic code. If the cause of the problem is not found, contact your
dealership for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the
ECM requires replacement, see Troubleshooting, "Electronic Control Module (ECM) - Replace".

STOP

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 13/01/2020
D6N XL Differential Steering, Electrohydraulic Implement TRACK-TYPE TRACTO... Page 4 of 4

• NOT OK - The continuity check does not agree.

Repair: There is an open in the signal circuits of the machine harness. Repair the machine harness or replace
the machine harness.

STOP