Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

1. ALL DIMENSIONS TO BE CHECKED ON


SITE AND ANY DISCREPANCY
REFERRED TO THE ARCHITECT

2. NO DIMENSIONS SHALL BE SCALED


FROM THE DRAWING
.

3. ALL R.C WORKS TO STRUCTURAL


D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1
ENGINEERS DETAILS
4,128 1,274 3,830 1,437 4,553 5,184 6,765 17,096 8,594 6,636 4,990 11,847 16,885
WATER TANKS AS SPECIFIED
6,072 2,518 2,472
HVAC COOLING MACHINE AS
BY SERVICE ENGINEER SPECIFIED BY ARCHITECT

+15,050 ROOF TOP LEVEL


COPING STONE LEVEL HVAC COOLING MACHINE AS
230MM THICK BLOCK
+14,050 PARAPET WALL LEVEL SPECIFIED BY ARCHITECT BLUE GLASS WINDOW
WORK PLASTERED AND FITTED TO
ELAVATOR
PAINTED BY WEATHER ALUMINIUM
HEADROOM LEVEL
GUARD PAINT TO FRAMES,TO ARCH
ARCH APP APP
+11,050 +11,050
COPING STONE LEVEL COPING STONE LEVEL
+9,900 PARAPET WALL LEVEL
+9,900
THIRD FLOOR LEVEL

SECOND FLOOR
LEVEL
SECOND FLOOR
+6,750 LEVEL +6,750

CONCRETE CANOPY TO
DETAILS
FIRST FLOOR LEVEL
+3,600 FIRST FLOOR LEVEL +3,600

GROUND FLOOR ALUMINIUM DOOR TO BE GROUND FLOOR


LEVEL APPROVED BY ARCHITECT LEVEL
0.00 0.00

BASEMENT FLOOR BASEMENT FLOOR


LEVEL LEVEL
-3,000 -3,000

RIGHT SIDE ELEVATION


SCALE 1: 100

AMENDMENTS

NO . DATE. REV. COMMENTS

D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 D17

919 4,070 6,072 16,886 11,848 4,990 6,636 8,592 17,095 6,766 5,185 5,023 969 3,830 1,274 4,128
WATER TANKS AS SPECIFIED
BY SERVICE ENGINEER
230MM THICK BLOCK
ELAVATOR
HEADROOM LEVEL Architectural stamp
:
WORK PLASTERED AND
HVAC COOLING MACHINE AS +15,050
SPECIFIED BY ARCHITECT ROOF TOP LEVEL
PAINTED BY WEATHER BLUE GLASS WINDOW +14,050
GUARD PAINT TO FITTED TO PARAPET WALL LEVEL
ARCH APP ALUMINIUM
FRAMES,TO ARCH
COPING STONE LEVEL APP
+11,050 +11,050
COPING STONE LEVEL
PARAPET WALL LEVEL +9,900 +9,900
THIRD FLOOR LEVEL

SECOND FLOOR
LEVEL Consultant:
+6,750 +6,750
SECOND FLOOR
CONCRETE CANOPY TO LEVEL
DETAILS

FIRST FLOOR LEVEL


+3,600 +3,600
FIRST FLOOR LEVEL
ALUMINIUM DOOR TO BE ALUMINIUM DOOR TO BE
APPROVED BY ARCHITECT APPROVED BY ARCHITECT

GROUND FLOOR
LEVEL 0.00 0.00
GROUND FLOOR
LEVEL
1,274
919 4,070 6,072 16,886 11,848 4,990 6,636 8,592 17,095 6,766 5,185 5,023 969 3,830 4,128
BASEMENT FLOOR
LEVEL Project
-3,000 -3,000 BASEMENT FLOOR
LEVEL
PROPOSED MBEYA CONFERENCE
LEFT SIDE ELEVATION
CENTER TO BE BUILT ON PLOT
SCALE 1: 100 NO .......BLOCK.....TAZARA AREA IN
MBEYA

Client

MBEYA CITY COUNCIL


P.O BOx 149 - MBEYA

Drawing title
MBEYA CONFERENCE CENTER

Designed by VICTOR JOSEPH MELLA

Date 19/6/2024 Drawing Name RIGHT AND LEFT ELEVATIONS

REG :22100434040078 MOB;+255 768 807 760

PROJECT NO
E-MAIL. vjosemella09@gmail.com