Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Sta. 85+280 Right-Side Slope Stability Analysis (1.

65H:1V) using Fellenius Method or Swedish Method

calculation shown in
measured as per

measured as per

measured as per
identified as per

sec a= 1/cosa

u = gw * Zw
cross-section

cross-section

cross-section

W = b*h*g
each slice
report i = b*seca
Slice
No.
b h g a Zw W seca u u* i W*cosa- u* i sina W*sina
1 3.20 1.04 20.60 -0.60 0.00 68.3 1.0001 3.2002 0.00 0.00 68.29 -0.0105 -0.7152
2 3.20 2.87 20.60 5.00 0.17 189.1 1.0038 3.2122 1.68 5.39 183.02 0.0872 16.4833
3 3.20 4.38 20.60 10.70 0.69 288.7 1.0177 3.2566 6.75 21.98 261.73 0.1857 53.6074
4 3.30 5.55 20.60 16.50 0.99 377.1 1.0429 3.4417 9.68 33.32 328.23 0.2840 107.0979
5 3.20 6.37 20.60 22.50 1.07 419.9 1.0824 3.4637 10.53 36.46 351.49 0.3827 160.6928
6 1.00 6.39 20.60 26.50 0.98 131.5 1.1174 1.1174 9.63 10.76 106.95 0.4462 58.6888
7 3.20 6.07 20.60 30.70 0.76 400.4 1.1630 3.7216 7.46 27.75 316.54 0.5105 204.4204
8 3.20 5.98 20.60 37.50 0.12 393.9 1.2605 4.0335 1.14 4.59 307.94 0.6088 239.8142
9 3.20 5.07 20.60 45.10 0.00 334.2 1.4167 4.5334 0.00 0.00 235.91 0.7083 236.7374
10 1.90 3.75 20.60 51.90 0.00 146.6 1.6207 3.0792 0.00 0.00 90.44 0.7869 115.3484
11 1.90 1.61 20.60 57.70 0.00 62.9 1.8714 3.5557 0.00 0.00 33.59 0.8453 53.1322
36.615 2284.127 1245.308

(a) Using Peak Strength Parameters


Drained: cd or c' c' = 0 F.S. = 1.15
Drained: fd or f' f' = 32
R= 32.81 where c' La= c'R q ( q in radians )
q= 64.4

(b) Using Critical-State Parameter F.S. = 1.29


f'cv = 35
The acceptable F.S. must be from 1.00 to 1.30
More than 1.30 is too conservative
c' La = 0