112501-การแปรสภาพพลังงานกลไฟฟ้า-14
ครั้งที่ #14
ดร.บัลลังก เนียมมณี (BLN)
ภาควิชาวิศวกรรมไฟฟา
มหาวิทยาลัยโนโลยีพระจอมเกลาพระนครเหนือ
1
CHAPTER # 4
DC Machines
160
4.5 Speed Control
4.5.1 Ward-Leonard Control
– Vt control : armature voltage control mode
Ifm= constant at rated
Ifg = change with Vt
– If Control : filed current control mode is used
speed above base speed.
Vt= constant at rated
Ifm = decrease (field weakening)
161
4.5.2 Solid-State Control
Control Rectifiers
162
Single-Phase input, assume ia is continuous
2 2Vp
Vt = cos α (4.58)
π
For semiconverter
2Vp
Vt = (1 + cos α) (4.59)
π
Three-Phase input, for a full converter
3 6Vp
Vt = cos α (4.60)
π
For semiconverter
3 6Vp
Vt = (1 + cos α) (4.61)
2π
7
Vt = Ea + I a Ra (4.61a)
Ea = Ka Φωm (4.61b)
T = Ka ΦI a (4.61c)
163
EXAMPLE 4.11
The speed of a 10 hp, 220V, 1200 rpm separately excited
dc motor is controlled by a single-phase full converter
as shown in Fig.4.60. The rated armature current is 40A.
The armature resistance is Ra=0.25Ω and armature
inductance is La=10mH. The supply voltage is 265V.
The motor voltage constant is KaФ=0.18 V/rpm.
Assume that motor current is continuous and ripple-free.
For firing angle α =30˚ and rated motor current, determine
the
a) Speed of the motor
b) Motor torque
c) Power to the motor
164
(c) Power to the motor is
P = (ia )rms
2
+ I a Ea
Since ia is ripple free
P = I a2Ra + Ea I a
= Vt I a
= 206.6 × 40
= 8264W
11
Choppers
ton
Vt = V
T
= αV
where ton = on time
T = chopping period
α = duty ratio
12
165
Example 4.13
The speed of the separately excited dc motor is control by a
chopper as shown in Fig.4.62a. The dc supply voltage is 120V,
the armature circuit resistance is Ra= 0.5Ω, the armature circuit
inductance is La= 20mH, and the motor constant is KaФ=0.05
V/rpm . The motor drives a constant-torque load requiring an
average armature current of 20A. Assume that motor current is
continuous.
Determine the
(a) Range of speed control
(b) Range of the duty cycle α
13
166
Closed-Loop Operation
15
16
167
Permanent Magnet DC (PMSM) Motors
17
Advantage of PMDC
• Copper losses in field winding is absent this increase
efficiency
• No space require for field winding
• PMDC is smaller than corresponding wound-pole
motor
Disadvantage of PMDC
• Risk to demagnetization
• The magnetic fields is always present even when
motor is not used.
• The enclosure of the motor should be carefully
designed so that no foreign matter is attracted.
18
168
Print Circuit Board (PCB) Motors
19
20
169
Advantages
– Motor can acceleration and deceleration from 0 to
4000 rpm in 10 millisecond because its low rotor
inertia.
– The armature inductance is low because no iron in
rotor: there little arc, longer brush life and high-
speed capacity.
– Low armature time constant
– Motor has no cogging torque because the rotor is
nonmagnetic.
– Used for: applications requiring high performance
characteristics.
21
170