GENERAL NOTES:

1.0 Tube & Coupler System Scaffold Is Conformed to These European Standards:
1. UNE-EN 12810-1 Façade Scaffolds Made of Prefabricated Components - Part 1: Products
4 3 2 1 Specifications
2. UNE- EN 12810-2 Façade Scaffolds Made of Prefabricated Components - Part 2: Particular Methods

B
of Structural Design.
6000 6000 6000 3. UNE-EN 12811-1 Temporary Works Equipment. Scaffolds. Performance Requirements and General
Design.
LVL Planks 4. UNE-EN 12811-2 Temporary Works Equipment. Information on Materials
5. UNE-EN 12811-3 Temporary Works Equipment. Load Testing
wire rope anchored to steel 12mm DIA Min. 3 Clips
column, loop around
6. UNE-EN 74-1 Couplers, Spigot Pins and Base Plates for Use in Falsework and Scaffolds. Couplers for
Steel Ladder Beam
3 Girder
Wire Rope
Tubes. Requirements and Test Procedures.
Couplers
1.1 Reference Code & Standard.
1.1 Saudi Aramco Scaffold Safety Handbook (SSH).
1.2 Saudi Aramco Safety Requirements for Scaffolding (G.I. 8001).
Tensioning
Device 1.3 BS 5973 - Code of Practice for Access and Working Scaffold and Scaffold Structures in Steel.

2.0 All Dimensions Are in Millimeters, Unless Otherwise Noted on Plans.

A 3.0 Tubes, Bearers (Transoms), Ledgers (Runners) & Bracing are Made of Steel.
4.0 Fittings (Couplers) Made of Steel, EN 74 Specification (SSH).

5.0 Fittings (Couplers, Clamps, Etc.) of A Metal Type Approved to ANSI or Equivalent Requirement. They
12mm DIA Shall be Examined Regularly & Must be Taken to Ensure That Moving Parts are Sound & Well
Steel Lubricated and That Threads are Not Stripped.

A Wire Rope
A 6.0 Working Platforms Shall Be Fully Decked on Top with Toe Boards All Around & Shall Conform to The
Requirements of Saudi Aramco Construction Safety Manual.
7.0 Working Platforms Shall be Provided with Top and Mid Guardrails All Around, Top rail Height Shall be
1000 mm Above the Landing &/or Platform.
8.0 Scaffolding Approved Metal Planks: Proof tested, Certified and Approved.
Tensioning
Device 9.0 Platforms Shall be Closed Planked According to Aramco Scaffold Safety Handbook (SSH). Chapter -
3 Clips 9.8.4 To 9.8.5
10.0 Erection:
10.1 Scaffolding Shall Be Erected and Dismantled by Experienced Men, Working Under the Direction of
a Competent Engineer.
10.2 Standards Shall be Set Accurately in Place and Checked Vertically by Using a Spirit Level or by
B Using Vertical Lines on The Structure.
10.3 Scaffolding Couplers Should be Tightened with Proper Scaffolding Spanners.
10.4 Scaffolding Materials Shall Not be Thrown or Dropped from Heights.
10.5 Standards Pitched Steel Plate.
Tensioning 11.0 Sources of Ignition (Generators) & Safe Air Supplies to be Kept Away from Flammable Materials &
3 Girder Device
m0.2 regdeL
Their Vapors.
12.0 Planks Shall be Secured at Both Ends.

1000
Platform Tubes Couplers 13.0 Ensure the Full Body Harness with Shock-Absorbing Lanyards Only a Approved by Saudi Aramco With
Rated Capacity of 2,260 Kg.
Typical Plan for Lifeline & Suspended Scaffolding

2000
B

Ledger 2.0m

Ledger 2.0m
m0.2 regdeL

14.0 Scaffolds & Scaffold Components Shall Not be Loaded in Excess of Their Load Rating.

Scale: 1:75

1000
Access 15.0 Access Opening Through Working Platforms Shall be Kept Closed at All Times Except When Working

Ledger 1.0m
Install Scaffold Access Tower 30m apart along Pipe rack Men are Passing.
m0.2 regdeL 16.0 The Guardrail System Shall be Able to Withstand A Force of at Least 90 Kg Applied in Any Downward
or Horizontal Direction at Any Point on The Top rail or Equivalent.
2000
17.0 Personnel Shall Not be on Any Scaffold During Storm or High Winds Having Sustained Winds More
Than 65 Km/H (40 Mph)
18.0 Any Scaffold Component That is Obviously Damaged, Excessively Corroded, Detective or Does Not
Meet the Applicable Codes & Standards Shall be Marked with Bright Fluorescent Orange Paint &
Immediately Removed from Saudi Aramco Property.
19.0 Ensure That No Gaps at The Edge/Corner/Bend of The Work Platform by Fully Covering it With
4 3 2 1 20mm (1-Inch) Thick, Exterior Grade Plywood and Such Plywood Covering Shall be Overlapped at least
The Width of The Gap, 300 Mm (12 Inch) Minimum, on Both Sides of The Opening and Held in Place
with Cleats.
4000 6000 6000 6000
Min. 3 Clips Min. 3 Clips 20.0 Working Platform Shall be Kept Free of Obstructions, Unnecessary Materials, Projecting Nails and
12mm DIA
3 Clips
Other Tripping Hazards (Including Uneven Decking).
Steel wire rope anchored to steel
Wire Rope column, loop around
21.0 Ensure Scaffoldings are Installed on Compact Ground or Appropriate Measures Shall be Taken to
Prevent Scaffolds from Tilting Sideways.
Tensioning Tensioning
3 Girder Device 3 Girder 3 Girder Device
Couplers Couplers Couplers 22.0 Contractor Shall Provide Hard Barricade, Warning Signs and Warning Lights to Protect from Vehicle
Impact.
Top Rail
Mid Rail 23.0 Ensure that Screw Jacks Shall not be Adjusted to more than 23 of the Total Length of
Ledger 1.0m Ledger 1.0m
the Threaded Section.
695 695
Standard 1.5m

Standard 1.5m

Standard 1.5m

Ledger 1.0m Ledger 1.0m


100

100
Ledger 1.0m
g
2.0
x2
.0
m
Ledger 1.0m
LIGHT DUTY
cin
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

Bra

LIGHT DUTY SCAFFOLD


1000

200 1200 1400 400 1400 1200 200


MAX. LIVE LOAD ON PLATFORM
Ledger 1.0m Ledger 1.0m
20 Kg
( 120 kg/m² )
.0
m
ONE MAN AND 20 kg MAX. PER SQ. METER
MAX. TOTAL LOAD 120 KG
ONE WORKING LEVELS
2000

x2
2.0 PER SQ. METER (25 PSF)

ONE PLANKED LEVELS


Ledger 1.0m Ledger 1.0m
g
cin
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

Bra

Ladder
Ledger 1.0m Ledger 1.0m

WARNING
Ledger 1.0m Ledger 1.0m

CLIENT:

m
.0
2000

x2
2.0
Ledger 1.0m Ledger 1.0m
g
cin
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

Post 2.0m Bra

Ledger 1.0m Ledger 1.0m

Ledger 1.0m Ledger 1.0m

Diagonal Bracing

m
.0
2000

x2
2.0
Ledger 1.0m Ledger 1.0m
g
cin
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

Bra

Ledger 1.0m Ledger 1.0m


13400

Ledger 1.0m Ledger 1.0m

4-FEB-24
m
.0
2000

x2
2.0
Ledger 1.0m Ledger 1.0m
g
cin
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

Bra

Ledger 1.0m Ledger 1.0m

Tie Back for Stair


Tower
Ledger 1.0m Ledger 1.0m

Mohamed Salah Ibrahim M.E As Shown

m
2000

.0
x2
2.0
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

g
cin
Bra

Ledger 1.0m Ledger 1.0m

Ash T. Arshad 4-FEB-24


m
2000

.0
x2
2.0
m0.2 dradnatS

m0.2 dradnatS

m0.2 dradnatS

g
cin
Bra

Post Head Jack / Resa Gulf Scaffolding Co. Ltd.


Screw Jack Ledger 1.0m Ledger 1.0m
350

1000 1000
2000

6000 6000 6000

TYPICAL HORIZONTAL LIFELINE FOR SCAFFOLD WORKS

Transversal Section B-B Longitudinal Section A-A Pipe Racks Area, HMYM GCP 5, Jafurah, KSA

Scale: 1:75 Scale: 1:75


RGS-DWG-MI-1101 01 0