171 DARTMOUTH
NOTES:
1. THE SHEAR WALL SYSTEM CONSISTS OF A SANDWICH OF TWO CONTINUOUS STEEL FACE
STREET
PLATES FILLED WITH HIGH-STRENGTH CONCRETE. THE STEEL PLATES CARRY BOTH
TENSILE AND COMPRESSIVE LOADS WHILE THE CONCRETE CARRIES COMPRESSIVE LOAD GARAGE WEST
AND PROVIDES STABILITY FOR THE CONCRETE FILLED COMPOSITE PLATE SHEAR WALL
PLAN VIEW (CF-CPSW) SANDWICH PANEL SYSTEM. TOGETHER THE COMPOSITE CONCRETE AND
COMMERCIAL OFFICE
PLAN VIEW STEEL PLATES RESIST WALL SHEAR DEMANDS. VERTICAL REINFORCING BARS IN THE TOWER
CONCRETE INFILL IS NOT REQUIRED.
6. CONCRETE PLACEMENT MAY BE PUMPED INTO THE SHEAR WALLS BY UTILIZING ACCESS Pelli Clarke & Partners
ONE STORY PORTS IN THE STEEL PANELS AT THE BOTTOM OF EACH CONCRETE LIFT. 322 Eighth Avenue, 11th Floor
COUPLING ALTERNATIVELY, CONCRETE MAY BE PLACED THROUGH ACCESS HOLES ABOVE THE New York, NY 10001
BM INFILL WALL CONCRETE FILL ELEVATIONS. A TREMIE METHOD OR FULL SCALE MOCK UP MUST BE Tel: (212) 417-9496
PANEL, TYP LEVEL www.pcparch.com
UTILIZED TO ENSURE OR DEMONSTRATE PROPER CONSOLIDATION. CONCRETE MAY NOT
TWO-STORY BE PLACED VIA FREE FALL FROM THE TOP OF THE ERECTED STEEL WITHOUT PRIOR Architect of Record
BOUNDARY SEE "TYP CPSW WRITTEN APPROVAL. THE CONTRACTOR MAY PERFORM A CONCRETE FILLING
ELEMENT, TYP THICKNESS" DET PROCEDURE MOCK UP TO VALIDATE ALTERNATIVE CONCRETE INSTALLATION
TECHNIQUES TO ENSURE PROPER CONSOLIDATION.
SPLICE, SEE "TYP CPSW PANEL-
TWO-STORY 7. CPSW CONCRETE PLACEMENT ACCESS HOLES HAVE BEEN ILLUSTRATED IN THE WELDED
TO-PANEL CONNECTION", TYP
BOUNDARY STEEL BOX COUPLING BEAMS. CONTRACTOR SHALL ENSURE THAT CONCRETE Stantec Architecture and Engineering P.C.
ELEMENT, TYP COMPLETELY FILLS ALL COUPLING BEAMS. 311 Summer Street
Boston, MA 02210
Tel: (617) 234-3100
8. CONCRETE FLOW VENTS HAVE BEEN ILLUSTRATED IN THE WALL CORNER BOUNDARY www.stantec.com
D ELEMENTS WHERE ADJACENT TO INCOMING COMPOSITE PANELS. CONTRACTOR SHALL
ENSURE THAT CONCRETE COMPLETELY FILLS ALL CORNER BOUNDARY ELEMENTS AND Consultant
LEVEL
LEVEL WALL PANELS.
11. THE CROSS TIE EXTENSIONS THAT PROTRUDE FROM THE CPSW WALL PLATE MAY NOT
LEVEL BE MODIFIED AS PART OF INSTALLATION OF OTHER SYSTEMS (ELEVATOR RAILS, STAIR
CLIPS, ETC.). SEE "TYPICAL CPSW CROSS TIE" DETAIL FOR DETAILS OF THE CROSS TIE
PROTRUSIONS.
LEVEL
Notes
TYPICAL CPSW WALL PANEL WITH LINK BEAM ELEVATION TYPICAL CPSW WALL PANEL ELEVATION TYP COMPOSITE PLATE SHEAR WALL NOTES
6 8 10
C
WALL "B"
3"
PRE-ATTACHED TO PANEL,
TYP, BY CONTR WALL "B" HORIZ
DET SPLICE BOLTS,
TIE RODS SPCG PER SHEAR WALL EL,
STEEL PL SEE SPLICE EL (2) COLUMNS
SEE "TYPICAL CPSW CROSS TIE" DET
SHEAR WALL EL OF BOLTS MIN
1 2"
WALL "B" HORIZ
SPLICE BOLTS,
(4) COLUMNS
WALL "A" HORIZ SPLICE BOLTS 12" OF BOLTS MIN
COUPLING BM SEE 2" TYP
WALL "A" HORIZ
"COMPOSITE COUPLING SPLICE BOLTS,
B BEAM SCHEDULE" WALL "A" VERT SPLICE BOLTS
(4) COLUMNS
LEVEL OF BOLTS MIN
DETAIL
AT LOCATIONS WHERE
COUPLING BEAMS OVERLAP
AND ARE THE SAME DEPTH, GMP SET 2022.01.28
PROVIDE CONT COUPLING PERMIT SET 2021.11.24
CONSTRUCTION DOCUMENTS SET 2020.10.08
BEAM ACROSS THE WALL
PANEL. SPLICE FLANGE PL Issued/Revision YYYY.MM.DD
6"
WITH CJP AS REQUIRED CROSS TIE PLTHK, PER CPSW CROSS TIE PL THK, PER CPSW
ROD, TYP ELEVATIONS, TYP ROD, TYP ELEVATIONS, TYP Permit/Seal
AT LOCATIONS WHERE
COUPLING BMS OVERLAP,
TO REQUIRED LENGTH
AT SPLICE
6" MAX
18"
24"
OR 6" FROM BOUNDARY 12" MAX
TYP AT BOUNDARY TYP AT SPLICE
TYPICAL COMPOSITE
14" THICK CPSW 20" THICK CPSW
PLATE SHEAR WALL
DETAILS
ORIGINAL SHEET - ARCH E1
2/11/2022 1:55:12 PM
16
TYPICAL COUPLING BEAM INFILL WALL PANEL
19
TYPICAL COMPOSITE PLATE SHEAR WALL THICKNESS S-341
© 2018 Stantec
554