• The highest accuracy results from 12-bit A/D conversion with floating-point math following
per-channel analog filtering and built-in calibration.
• By virtue of these and the differential input feature, Model 100 is capable of monitoring
even noisy signals, yielding a typical measurement accuracy of 0.1% of full scale, after
calibration.
Flexibility...
• Menu driven software permits easy setup of standard functions to obtain finished
engineering unit answers and precisely timed responses for process control.
• Every system is directly compatible with the Dasibi Environmental Corp. Model 8001
Datalogger. All boards are interchangeable and the operating software’s menu system
retains the same structure.
Reliability...
• Model 100 dynamic database makes 100% of acquired data available on a real-time
basis.
Data Collection
Up to 32 analog input channels.
Selectable averaging times of 1,2,3,4,5,6, 10, 12,15, 20 or 30 minutes in addition to hourly
averages.
Engineering unit conversions.
Input voltage range selectable on a per channel basis.
Single-ended or differential selectable on a per channel basis.
Automatic data validation and flagging.
Calculations
Selectable calculation function for each data channel: Accumulation, subtraction and peak.
Standard averaging.
Vector or scalar wind direction.
Vector or scalar wind speed.
Standard deviation of wind direction (Sigma theta)
Polynomial linearization
Reporting
Hourly report of intermediate averages.
Daily report of hourly averages.
Zero/span and multipoint calibration reports.
Real-time data reports on display or printer.
Data can be reported from main memory or data pack.
Events
Up to 30 user definable events may be specified to control external devices.
Each event can contain up to 9 steps of independently programmable durations.
Starting time, date and frequency specified for each event.
Event frequencies from minutes to days may be specified.
Calibrations
Calibration results are automatically captured for internally or externally controlled calibrations.
Zero/span, precision or multipoint calibrations are supported
Alarms
Multiple user defined alarm conditions.
Alarms may be based on instantaneous, intermediate or hourly averages.
Specified outputs maybe activated by alarms.
Alarm messages sent via modem.
ANALOG INPUTS
Input Type Single-ended or differential voltage inputs, software
selectable by channel
Digital I/O
Status input voltage range up to 35V, TTL, or contact closure
(internal 33K pull-up resistor to 5V)
Printer port:
Compatibility with IBM PC
Connector 25 pin female D-subminiature
Calendar Clock
Features hour, minute, second, month, day, and year with
automatic leap year compensation.
Accuracy +/-1 minute per month at 25°C
Battery backup greater than 7 years without power applied
RAM
Size 32K bytes (128K bytes fro 8001)
EPROM up to 1 MB
External Memory
Features write protect switch, rechargeable battery
Size 512K bytes (200,000 data points)