ISOLATED FOOTINGS

PLINTH LEVEL DETAILS OF FOOTINGS


FOOTING
INDEX
Fx Fy D E REINF ALONG Fx REINF ALONG Fy
GR. LVL
C1 to C15
2000 2000 500 200 10 DIA @ 125 C/C 10 DIA @ 125 C/C
150

COLUMNS
GROUND LEVEL (TO BE VERYFIED AT SITE.)

COLUMN DETAILS OF COLUMNS


TIE-BEAM 75 TH BRICK SOLING
FOUNDATION DEPTH =. 1650 FROM

INDEX Cx Cy Main Reinf. Stirrup


AS / DET.
80 8 DIA @
C1 to C15 300 400 8-16 DIA
13
5° 100 c/c
8 Dia Ring @ 100 c/c
DET.OF 8 DIA RING 2-16DIA 2-16 +
2-16DIA 2-16 + 2-16 + 2-16 +
4-16 DIA 2-20 DIA 2-16DIA 2-16DIA
2-20 DIA 2-20 DIA 2-20 DIA
COLUMN MAIN REINF.
3-16 DIA 3-16 DIA
L/3 L/3 L/3 L/3 L/3 L/3 L/3 L/3
REINF ALONG `Fy' A A B A A B A A B A A B A
75 75 FB :: C1- C15 (250x450)
REINF ALONG `Fx'
STIRRUP INDEX
INDEX DETAILS.
A 8 DIA 2 LEGGED STIRRUP @ 100c/c
FOUNDN LVL 400
D Floor Beam Details B 8 DIA 2 LEGGED STIRRUP @ 150c/c
E
4-16 DIA 2-16 DIA 4-16 DIA 2-16 DIA
4-16 DIA
PCC 1:4:8
75 THK FLAT BRICK SOLING
SECTION ON A-A 3-16 DIA 3-16 DIA
L/3 L/3 L/3 L/3
A A B A A A B A
75
TIE BEAM :: C1-C15 (250x350)
STIRRUP INDEX
Tie Beam Details
INDEX DETAILS.
75 Cx 75 A 8 DIA 2 LEGGED STIRRUP @ 100c/c
B 8 DIA 2 LEGGED STIRRUP @ 150c/c

REINF ALONG `Fy'


75
NOTES:
A Cy A 1. ALL DIMENSIONS ARE IN MM UNLESS
6. Fx ,Fy AND Cx , Cy ARE THE FOOTING
AND COLUMN DIMENSIONS ALONG 'X'

Fy
STATED OTHERWISE. AND 'Y' AXES RESPECTIVELY AS SHOWN
75 2. CONCRETE GRADE : M-20 (1-CEMENT IN LAYOUT OF COLUMN AND FOOTING.
:1.5 SAND : 3 COURSE AGGREGATE 7. DEVELOPMENT (LAP) LENGTH SHALL
BY VOLUME FOR NOMINAL MIX) BE 57 TIMES THE MAXIMUM BAR DIA .
REINF ALONG `Fx' 3. CLEAR COVER :: FOUNDATION : 50 MM.
COLUMN- 45MM. 8. NOT MORE THAN HALF OF THE TOTAL
NOS. OF BARS SHALL BE LAPPED
4. AGGREGATE SIZE :: FOUNDATION AND
75 AT ANY SECTION.
COLUMNS : 20 MM DOWN GRADED. 9. DEWATERING SHOULD BE DONE
5. REINFORCEMENTS GRADE : Fe-500(TMT) WHERE NECESSARY AND ADD 10%
75 Fx 75 EXTRA CEMENT IN SUCH CASE .
TYPICAL PLAN OF AN
ISOLATED FOOTING