Repcoat S100

Solvent based high performance alipha c acrylate protec ve coa ng

Description
Technical Properties:
Repcoat S100 is ready for use, single component, alipha c
White, grey, buff, brown &
acrylate coa ng for external and internal use over variety Colour:
many other colours
of concrete and masonry substrates. The system also
includes an under coat of a silane-siloxane base which Volume solids: 35 ± 3%
when used with Repcoat S100 will provide maximum
protec on against chloride ingress and carbon dioxide Specific gravity: 1.24 ± 0.05
diffusion. Over coa ng me for
5 hr @ 25°C
Repcoat S100 Primer:
Repcoat S100 Primer is a penetra ng hydrophobic silane-
siloxane base which when applied will react with concrete Carbon dioxide diffu- > 250 m equivalent thick-
and masonry producing a clear hydrophobic barrier that sion resistance: ness of air
prevent the passage of water and hence protect exposed Carbon dioxide diffu- > 500 mm equivalent thick-
reinforced concrete structures from a ack by chloride sion resistance: ness of concrete
ions.
Touch dry me: 30 - 40 min @ 25oC
Applications Applica on tempera-
5 - 50°C
ture:
Repcoat S100 is an excellent protec ve and decora ve
fair face coa ng which can be used for many applica ons Freeze/thaw salt scal- Unaffected
including: ing (50 cycles)
Good quality concrete Severe scaling
 Retaining walls. (control)
 Bridge abutments. ASTM C672
 External concrete of storage tanks.
Fire tes ng - Spread
 Mul story buildings and villas.
of flame: Class 1
 Pre-cast elements and concrete cladding.
BS 476, Part 7
 Commercial and Industrial complexes.
The results achieved are for the Repcoat S system ap-
Advantages plied at the minimum recommended applicaƟon rate.

 Dual protec ve system, will form an Excellent


Protec ve barrier against chloride ions, carbon dioxide Surfaces containing slight surface imperfec on or blow-
and water borne. holes should be filled with a skim coat of cemen ous
 Durable - highly resistant to UV and weathering. repair mortar such as Cemfair PF. Deep holes and
 Moisture vapour permeable, allows concrete to defected areas should be repaired with cemen ous
breath. products from DCP-Repair range.
 Available in a wide range of decora ve colours.
 Single component. Application
 Colour stable, with excellent hiding power.
The prime coat should be sprayed or brush applied at the
Method of Use rate of 0.2 litre/m2. It is recommended to apply two coats
of Repcoat S100 at the stated rate of applica on. The first
Surface Preparation coat should be applied evenly by roller, brush or airless
spray machine at a rate of 0.15 litre/m2 and allowed to
Surface prepara on is very important to get a good quality dry.
finish and best performance. Any surface to be coated
must be clean, sound and free from oil, grease, curing
compound, or any contamina on. Any contaminants
should be removed by light grit blas ng.
Repcoat S100

The second coat should be applied perpendicular to the For further informa on refer to the Material Safety Data
first coat at the rate of 0.15 litre/m2. Repcoat S100 may Sheet.
need to be thinned up to 5% by weight when using airless
spray machine. Fire

Cleaning Repcoat S100 and Repcoat S100 Primer, and DCP primer
are flammable. Ensure adequate ven la on. Do not use
Tools and equipment can be cleaned with DPC-Solvent near a naked flame and do not smoke during use.
when wet. Dried Repcoat S100 should be removed using
DCP-Solvent or mechanically. More from Don Construction Products

Packaging A wide range of construc on chemical products are


manufactured by DCP which include:
Repcoat S100 is available in 20 litre drums (24.8 kg).
Repcoat S100 Primer is available in 20 and 200 litre  Concrete admixtures.
drums.  Surface treatments
 Grouts and anchors.
Coverage  Concrete repair.
 Flooring systems.
Repcoat S100 Primer: 0.2 litre/m² per coat.  Protec ve coa ngs.
Repcoat S100: 0.15 litre/m² per coat.  Sealants.
 Waterproofing.
Storage  Adhesives.
 Tile adhesives and grouts.
Repcoat S100 and Repcoat S100 Primer should be stored  Building products.
under cover at an ambient temperature range of 10°C  Structural strengthening.
and 25°C.

Shelf Life

Repcoat S100 has a shelf life of 9 months from date of


manufacture if stored in proper condi ons and sealed
drums.

If these condi ons are exceeded, DCP Technical


Department should be contacted for advise.

Cautions

Health and safety

As with all paints, care should be taken during use and


storage to avoid contact with skin, eyes and mouth.
Wear suitable protec ve clothing, gloves and eye/face
protec on.

Should accidental skin contact occur, remove immediately


with plenty of clean water. If swallowed, seek medical
a en on immediately - do not induce vomi ng.