Offer No # AQP-U-21002 (A)Date :2021-04-13

Project : 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant
Customer : PRAJ INDUSTRIES LTD
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 100-250 Reference Curve 100-250_50_2_A_R02
Speed Frequency Duty Point : Suction : Discharge :
2975 RPM 50 Hz Q = 230.0 m3/hr H= 100.0 m 125 mm 100 mm
Customer Details
Address - Tag Number P-1607 A-CO2 Scrubb. Colm.Pump
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 230.0 m3/hr Fluid Water containing carbon dioxide
Head 100.0 m Specific Gravity 1
NPSHA 9m Temperature -
Suction Pressure 1 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 1 Frequency 50 Hz

Performance Data @DP


Efficiency 80.01 % NPSHR 5.88 m
Input 78.29 kW Shut Off Head 110 m
Max. Power 98.65 kW Stage 1
Speed 2975 RPM Impeller Dia (Approx) 276 mm
Max allowable soft solid size 7 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF8 (ASTM A743 Gr CF8)

Impeller Type Closed IMPELLER CF8 (ASTM A743 Gr CF8)

Bearing (DE/NDE) - NECK RING CF8M(ASTM A743 Gr CF8M)

Bearing Lubrication Oil SHAFT SS ASTM A 276 CL 316

Rotation (from coupling End) CW SHAFT SLEEVE SS ASTM A 276 CL 316

Recommended Power (Pole) 90.0 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Water containing
Consultant - Specific Gravity 1
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 100-250 Solid Size 7 mm

2975 RPM 50 Hz Flow 230.0 m3/hr Head 100.0 m Stage 1

null

Input 78.29 kW NPSHA 9m Size Pump Nozzle Recommended

PrimeMover Power 90.0 kW NPSHR 5.88 m Suction (mm) 125 250

Eff 80.01 % Shut Off Head 110 m Discharge (mm) 100 150

P-1607 A-CO2 Scrubb. Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Colm.Pump Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 100-250_50_2_A_R02
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 100-250 Reference Curve 100-250_50_4_B_R02
Speed Frequency Duty Point : Suction : Discharge :
1465 RPM 50 Hz Q = 150.0 m3/hr H= 20.0 m 125 mm 100 mm
Customer Details
Address - Tag Number P-1601 A/B - H2S Scrubber
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 150.0 m3/hr Fluid Sodium Bicarbonate
Head 20.0 m Specific Gravity 1.08
NPSHA 18 m Temperature -
Suction Pressure 1.9 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 80.14 % NPSHR 1.76 m
Input 11.01 kW Shut Off Head 26 m
Max. Power 11.83 kW Stage 1
Speed 1465 RPM Impeller Dia (Approx) 271 mm
Max allowable soft solid size 7 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF3M

Impeller Type Closed IMPELLER CF3M

Bearing (DE/NDE) - NECK RING CF3M

Bearing Lubrication Oil SHAFT SS316L

Rotation (from coupling End) CW SHAFT SLEEVE SS ASTM A 276 CL 316 L

Recommended Power (Pole) 15.0 kW (4)

Shaft Sealing Gland

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Sodium
Consultant - Specific Gravity 1.08
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 100-250 Solid Size 7 mm

1465 RPM 50 Hz Flow 150.0 m3/hr Head 20.0 m Stage 1

null

Input 11.01 kW NPSHA 18 m Size Pump Nozzle Recommended

PrimeMover Power 15.0 kW NPSHR 1.76 m Suction (mm) 125 200

Eff 80.14 % Shut Off Head 26 m Discharge (mm) 100 125

P-1601 A/B - H2S Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Scrubber Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 100-250_50_4_B_R02
Offer No # AQP-U-21002 (A)Date :2021-04-13
Project : 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant
Customer : PRAJ INDUSTRIES LTD
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 25-125 Reference Curve 25-125_50_2_E_R01
Speed Frequency Duty Point : Suction : Discharge :
2830 RPM 50 Hz Q = 5.0 m3/hr H= 12.0 m 40 mm 25 mm
Customer Details
Address - Tag Number P-1603 A/B - Gas Wash Colm. Rec.
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 5.0 m3/hr Fluid Water
Head 12.0 m Specific Gravity 1
NPSHA 18 m Temperature -
Suction Pressure 1.8 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 38.88 % NPSHR 4.12 m
Input 0.42 kW Shut Off Head 13 m
Max. Power 0.52 kW Stage 1
Speed 2830 RPM Impeller Dia (Approx) 101 mm
Max allowable soft solid size 1 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF3M

Impeller Type Closed IMPELLER CF3M

Bearing (DE/NDE) - NECK RING CF3M

Bearing Lubrication Oil SHAFT SS316L

Rotation (from coupling End) CW SHAFT SLEEVE ASTM A 276 32760

Recommended Power (Pole) 0.75 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Water
Consultant - Specific Gravity 1
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 25-125 Solid Size 1 mm

2830 RPM 50 Hz Flow 5.0 m3/hr Head 12.0 m Stage 1

null

Input 0.42 kW NPSHA 18 m Size Pump Nozzle Recommended

PrimeMover Power 0.75 kW NPSHR 4.12 m Suction (mm) 40 40

Eff 38.88 % Shut Off Head 13 m Discharge (mm) 25 32

P-1603 A/B - Gas Wash Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Colm. Rec. Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 25-125_50_2_E_R01
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 40-200 Reference Curve 40-200_50_4_A_R02
Speed Frequency Duty Point : Suction : Discharge :
1435 RPM 50 Hz Q = 20.0 m3/hr H= 15.0 m 65 mm 40 mm
Customer Details
Address - Tag Number P-1604 A/B - Side Stream Pump
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 20.0 m3/hr Fluid Sodium Bicarbonate
Head 15.0 m Specific Gravity 1.08
NPSHA 18 m Temperature -
Suction Pressure 1.3 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 66.64 % NPSHR 1.1 m
Input 1.32 kW Shut Off Head 16 m
Max. Power 1.62 kW Stage 1
Speed 1435 RPM Impeller Dia (Approx) 218 mm
Max allowable soft solid size 3 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF3M

Impeller Type Closed IMPELLER CF3M

Bearing (DE/NDE) - NECK RING CF3M

Bearing Lubrication Oil SHAFT SS316L

Rotation (from coupling End) CW SHAFT SLEEVE ASTM A 276 32760

Recommended Power (Pole) 2.2 kW (4)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Sodium
Consultant - Specific Gravity 1.08
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 40-200 Solid Size 3 mm

1435 RPM 50 Hz Flow 20.0 m3/hr Head 15.0 m Stage 1

null

Input 1.32 kW NPSHA 18 m Size Pump Nozzle Recommended

PrimeMover Power 2.2 kW NPSHR 1.1 m Suction (mm) 65 65

Eff 66.64 % Shut Off Head 16 m Discharge (mm) 40 40

P-1604 A/B - Side Stream Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Pump Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 40-200_50_4_A_R02
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 25-160 Reference Curve 25-160_50_2_E_R01
Speed Frequency Duty Point : Suction : Discharge :
2850 RPM 50 Hz Q = 5.0 m3/hr H= 35.0 m 40 mm 25 mm
Customer Details
Address - Tag Number P-1606 A/B - Sump Pump
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 5.0 m3/hr Fluid Sodium Bicarbonate
Head 35.0 m Specific Gravity 1.08
NPSHA 6m Temperature -
Suction Pressure 0.7 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 37.56 % NPSHR 3.29 m
Input 1.37 kW Shut Off Head 36 m
Max. Power 2.19 kW Stage 1
Speed 2850 RPM Impeller Dia (Approx) 162 mm
Max allowable soft solid size 1 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF3M

Impeller Type Closed IMPELLER CF3M

Bearing (DE/NDE) - NECK RING CF3M

Bearing Lubrication Oil SHAFT SS316L

Rotation (from coupling End) CW SHAFT SLEEVE ASTM A 276 32760

Recommended Power (Pole) 2.2 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Sodium
Consultant - Specific Gravity 1.08
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 25-160 Solid Size 1 mm

2850 RPM 50 Hz Flow 5.0 m3/hr Head 35.0 m Stage 1

null

Input 1.37 kW NPSHA 6m Size Pump Nozzle Recommended

PrimeMover Power 2.2 kW NPSHR 3.29 m Suction (mm) 40 40

Eff 37.56 % Shut Off Head 36 m Discharge (mm) 25 32

Prepared By/Checked By Aqualine Pumps


Tag Number P-1606 A/B - Sump Pump Offer No AQP-U-21002
Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 25-160_50_2_E_R01
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 100-200 Reference Curve 100-200_50_2_A_R02
Speed Frequency Duty Point : Suction : Discharge :
2945 RPM 50 Hz Q = 200.0 m3/hr H= 40.0 m 125 mm 100 mm
Customer Details
Address - Tag Number P-5201 A/B- CW Recir. Pump
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 200.0 m3/hr Fluid Water
Head 40.0 m Specific Gravity 1
NPSHA 9m Temperature -
Suction Pressure 1 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 80.06 % NPSHR 5.37 m
Input 27.21 kW Shut Off Head 49 m
Max. Power 29.21 kW Stage 1
Speed 2945 RPM Impeller Dia (Approx) 193 mm
Max allowable soft solid size 10 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF8 (ASTM A743 Gr CF8)

Impeller Type Closed IMPELLER CF8 (ASTM A743 Gr CF8)

Bearing (DE/NDE) - NECK RING CF8M(ASTM A743 Gr CF8M)

Bearing Lubrication Oil SHAFT SS ASTM A 276 CL 316

Rotation (from coupling End) CW SHAFT SLEEVE SS ASTM A 276 CL 316

Recommended Power (Pole) 37.0 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Water
Consultant - Specific Gravity 1
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 100-200 Solid Size 10 mm

2945 RPM 50 Hz Flow 200.0 m3/hr Head 40.0 m Stage 1

null

Input 27.21 kW NPSHA 9m Size Pump Nozzle Recommended

PrimeMover Power 37.0 kW NPSHR 5.37 m Suction (mm) 125 200

Eff 80.06 % Shut Off Head 49 m Discharge (mm) 100 125

P-5201 A/B- CW Recir. Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Pump Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 100-200_50_2_A_R02
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 65-160 Reference Curve 65-160_50_2_A_R02
Speed Frequency Duty Point : Suction : Discharge :
2885 RPM 50 Hz Q = 50.0 m3/hr H= 35.0 m 80 mm 65 mm
Customer Details
Address - Tag Number P-5601 A/B - Chilling Water
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 50.0 m3/hr Fluid Water
Head 35.0 m Specific Gravity 1
NPSHA 9m Temperature -
Suction Pressure 1 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 75.43 % NPSHR 3.32 m
Input 6.32 kW Shut Off Head 38 m
Max. Power 8.61 kW Stage 1
Speed 2885 RPM Impeller Dia (Approx) 168 mm
Max allowable soft solid size 5 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF8 (ASTM A743 Gr CF8)

Impeller Type Closed IMPELLER CF8 (ASTM A743 Gr CF8)

Bearing (DE/NDE) - NECK RING CF8M(ASTM A743 Gr CF8M)

Bearing Lubrication Oil SHAFT SS ASTM A 276 CL 316

Rotation (from coupling End) CW SHAFT SLEEVE SS ASTM A 276 CL 316

Recommended Power (Pole) 7.5 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Water
Consultant - Specific Gravity 1
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 65-160 Solid Size 5 mm

2885 RPM 50 Hz Flow 50.0 m3/hr Head 35.0 m Stage 1

null

Input 6.32 kW NPSHA 9m Size Pump Nozzle Recommended

PrimeMover Power 7.5 kW NPSHR 3.32 m Suction (mm) 80 100

Eff 75.43 % Shut Off Head 38 m Discharge (mm) 65 65

P-5601 A/B - Chilling Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Water Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: 65-160_50_2_A_R02
WILO Mather and Platt Pumps Pvt. Ltd
Technical DataSheet
Customer PRAJ INDUSTRIES LTD Consultant -
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Application -
Pump Model PISO 32-160 Reference Curve ET ISO-2-50-2-D-R01
Speed Frequency Duty Point : Suction : Discharge :
2875 RPM 50 Hz Q = 15.0 m3/hr H= 30.0 m 50 mm 32 mm
Customer Details
Address - Tag Number P-1608 A/B Degassed Water
Enquiry Date 13/04/2021 Reference: -
Offer Date 13/04/2021 Offer No AQP-U-21002

Operating Conditions
Capacity 15.0 m3/hr Fluid Water
Head 30.0 m Specific Gravity 1
NPSHA 9m Temperature -
Suction Pressure 1 bar Viscosity
System / Pump in System Standalone / 1 Solid Size -
Total QTY 2 Frequency 50 Hz

Performance Data @DP


Efficiency 54.7 % NPSHR 3.61 m
Input 2.24 kW Shut Off Head 33 m
Max. Power 2.56 kW Stage 1
Speed 2875 RPM Impeller Dia (Approx) 156 mm
Max allowable soft solid size 2 mm Pump Performance Std ISO-9906-Gr2B

Constructional Features MOC


Type of Pump End Suction Item Description Specification

Mounting Horizontal CASING CF8 (ASTM A743 Gr CF8)

Impeller Type Closed IMPELLER CF8 (ASTM A743 Gr CF8)

Bearing (DE/NDE) - NECK RING CF8M(ASTM A743 Gr CF8M)

Bearing Lubrication Oil SHAFT SS ASTM A 276 CL 316

Rotation (from coupling End) CW SHAFT SLEEVE SS ASTM A 276 CL 316

Recommended Power (Pole) 3.7 kW (2)

Shaft Sealing Mechanical

Flange Type ANSI B16.1 CLASS 125 FF

Notes :
1.Suction Pressure more than Vapour Pressure of fluid.
2.NPSHA>NPSHR by atleast 0.5m
3.NPSHR at impleller CenterLine / Inlet.
4.Fluid is not aggressive towards pump components chemically / physically.

Technical matter is subjected to change without prior notice due to intensive Research & Development activities

WILO Mather and Platt Pumps Pvt. Ltd., Pune-19


WILO Mather and Platt Pumps Pvt. Ltd
Performance Chart
Customer PRAJ INDUSTRIES LTD Liquid Water
Consultant - Specific Gravity 1
Project 100 MTPD Biomass (Rice Straw) Processing Compressed Bio-Gas (CBG) Plant

Application -

Speed Frequency Pump Model PISO 32-160 Solid Size 2 mm

2875 RPM 50 Hz Flow 15.0 m3/hr Head 30.0 m Stage 1

null

Input 2.24 kW NPSHA 9m Size Pump Nozzle Recommended

PrimeMover Power 3.7 kW NPSHR 3.61 m Suction (mm) 50 65

Eff 54.7 % Shut Off Head 33 m Discharge (mm) 32 40

P-1608 A/B Degassed Prepared By/Checked By Aqualine Pumps


Tag Number Offer No AQP-U-21002
Water Date 13/04/2021

Note : 1.Pump Performance with ISO-9906-Gr2B 2. NPSHa should be at least 0.5 m higher than NPSHr
Technical matter is subjected to change without prior notice due to intensive Research & Development activities Reference: ET ISO-2-50-2-D-R01

You might also like