Professional Documents
Culture Documents
Drw
Drw
To* Attention
Notes
Acknowledgement Receipt
Name :
Signature :
Date :
1 - For Information
* - Please return a signed copy of this transmittal ** - Issues Codes
2 - For Construction
ALUMINIUM STRIP MEMBRANE ALUMINIUM STRIP MEMBRANE NOTES
(18 GAUGE) DETAIL-Z1 200 TK. PRE-CAST COVER SLAB DETAIL-Z1 200 TK. PRE-CAST COVER SLAB
+ 0.250 EL. (18 GAUGE)
COMPRESSIBLE FILLER WITH 50 ALUMINIUM STRIP MEMBRANE + 0.250 EL. ALUMINIUM STRIP MEMBRANE
COMPRESSIBLE FILLER WITH 50 1. FOR GENERAL NOTES REFER DRAWING 18005-S02
APPROVED SEALANT (18 GAUGE) APPROVED SEALANT (18 GAUGE)
COMPRESSIBLE FILLER WITH COMPRESSIBLE FILLER WITH 2. FOR TYPICAL DETAILS REFER DRAWINGS 18005-S02.1, 18005-S02.2 AND 18005-S02.3.
195
200
± 0.000 EL.
200
200
APPROVED SEALANT
± 0.000 EL. APPROVED SEALANT
F.G.L. 50 F.G.L. 50
600 600 3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL AND
ENGINEERING DRAWINGS AND SPECIFICATIONS.
TIE BEAM TIE BEAM TIE BEAM TIE BEAM
200 x 200 200 x 200 200 x 200 200 x 200 4. ALL DIMENSIONS ARE GIVEN IN MILLIMETERS.
5. CONCRETE MIX TO BE WITH A MAXIMUM AGGREGATE SIZE NOT GREATER THAN 20mm
WATERPROOFING A.P.S. WATERPROOFING A.P.S. 6. CONCRETE GRADE :
(ALL ROUND) (ALL ROUND) SLABS - C25
BEAMS - C25
WALLS - C25
COLUMNS - AS PER R/F DRAWING
2500
2500
7. NO CONCRETE IS TO BE POURED UNTIL THE REINFORCEMENT HAS BEEN INSPECTED AND
DETAIL-Y1 DETAIL-Y1 DETAIL-Y1 DETAIL-Y1 APPROVED BY THE CONSULTANT.
2500 250 3400 250
250 8. APPROVED WATERPROOFING TO BE APPLIED ON ALL SURFACES THAT CONTAIN OR EXCLUDE
250
WATER.
COMPACTED COMPACTED
3mm TK. 200 WIDE 3mm TK. 200 WIDE COMPACTED COMPACTED 9. SLAB OPENINGS' SIZE AND POSITION TO BE CHECKED WITH ARCHITECTURAL AND M&E
EARTH FILLING EARTH FILLING 3mm TK. 200 WIDE
MS WATER BAR MS WATER BAR EARTH FILLING 3mm TK. 200 WIDE EARTH FILLING DRAWINGS.
MS WATER BAR
DETAIL-W2 MS WATER BAR
DETAIL-W1 DETAIL-W2 10. UNLESS OTHERWISE INDICATED MINIMUM LAP IN REINFORCEMENT TO BE 52 x SMALLER BAR
TIE BEAM - 1.950 EL. 100 TIE BEAM TIE BEAM 100 DETAIL-W1 TIE BEAM
- 1.950 EL. DIAMETER AND ANCHORAGE LENGTH TO BE 52 x SMALLER BAR DIAMETER.
200 x 200 200 x 200 200 x 200 200 x 200
DETAIL-Y DETAIL-Y DETAIL-Y DETAIL-Y 11. UNLESS OTHERWISE INDICATED CLEAR COVER TO MAIN REINFORCEMENT TO BE AS
FOLLOWS
TIE BEAM TIE BEAM TIE BEAM TIE BEAM
200 x 200 200 x 200 200 x 200 200 x 200 COLUMNS = AS PER R/F DRAWING
WALLS = 40mm
EARTH EARTH EARTH EARTH BEAMS = 30mm
RETAINING SYSTEM 500 200 DETAIL-X1 200 500 RETAINING SYSTEM 500 200 DETAIL-X1 200 500
RETAINING SYSTEM RETAINING SYSTEM SLABS = 30mm
1 SECTION 2 SECTION
SK03 SK03 UNLESS OTHERWISE SPECIFIED
SCALE: 1:30 SCALE: 1:30
· COLUMNS AND BEAMS ARE SYMMETRICAL ABOUT GRID LINES OR CENTRE
LINES.
300
300
CL Wall CL Wall CL Wall CL Wall
B B 300
· WALLS AROUND DUCTS TO BE AS PER ARCHITECTURAL DRAWINGS.
STIFFENER COL. 1121 1630 STIFFENER COL. 1121 1630
300
200x200 200x200 EXISTING · DUCT SIZES TO BE AS PER ARCHITECT'S DRAWINGS.
EARTH RETAINING SYSTEM EXISTING EARTH RETAINING SYSTEM GROUND FLOOR
GROUND FLOOR · ALL TOILETS/BALCONIES/TERRACE FLOORS SHALL BE SLOPED TO THE
GULLIES AND SMOOTHLY FINISHED TO RECEIVE THE WATERPROOFING.
300x300x300 DEEP
LEGEND
CL Wall
CL Wall
CATCH PIT
(SCALE- 1:30)
LOAD BEARING REINFORCED CONCRETE
250 Tk. R.C. Wall
STRUCTURAL SUPPORT BELOW
1360
1360
7 EARTH RETAINING
EARTH RETAINING SYSTEM
1 1 SYSTEM
SK03 300 300 SK03
(TEMPORARY)
15mm THICK
3400
100
2290
2290
2325
600x600 MANHOLE
WITH HEAVY DUTY
2500
COVER
DETAIL - Y DETAIL - Y1 WATER PROOFING
AS SPECIFIED
+ 0.250 EL 200 Tk.
(SCALE- 1:20)
200
(SCALE- 1:20)
250 Tk. R.C. Wall
CL Wall
CL Wall
15mm THICK
X PROTECTIVE SCREED
35 10 35 600 x 600 MAN HOLE WITH 25
300
- -
SCALE: 1:50 SCALE: 1:50
DETAIL-W1
(SCALE- 1:8)
CLIENT CONSULTANT KEY PLAN REVISION DESCRIPTION DATE BY PROJECT DRAWING TITLE
PROPOSED APARTMENT HOTEL GENERAL ARRANGEMENT
GENERAL ARRANGEMENT OF
SERENIA LIMITED CIVIL AND STRUCTURAL ENGINEERING AT THALPE OF FUEL TANK
GROUND FLOOR
No. 724, CONSULTANTS(PVT)LTD.
772/A, WIJESINGHE MAWATHA, MADINNAGODA, DATE SCALE SHEET SIZE
MIHIRIPENNA, DESIGNED : Eng. RASADI DISANAYAKA DESIGN CHECKED : SH SHEET No
RAJAGIRIYA, SRI LANKA. 17-10-2023 AS GIVEN A2
THALPE. T +94 112 683 979 F +94 718 802 859 DRAWN : MH DRAFTING CHECKED : DH
STRENGTH SERVICEABILITY SAFETY SUSTAINABILITY E mail - contact@csec.lk Web - www.csec.lk PROJECT No 18005-SK03 REVISION ISSUE
FILE NAME, PATH AND OTHER INFO.
APPROVED : Eng. SHIROMAL FERNANDO 18005 R00 CON
NOTES
+ 0.250 EL. T12-125 T12-125 T12-125 T12-125 2. FOR TYPICAL DETAILS REFER DRAWINGS 21008-S02.1, 21008-S02.2 AND 21008-S02.3.
+ 0.250 EL.
T12-125 T12-125 T12-125 T12-125
3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ARCHITECTURAL AND
± 0.000 EL. ± 0.000 EL. ENGINEERING DRAWINGS AND SPECIFICATIONS.
F.G.L. F.G.L.
T12-125 T12-125 4. ALL DIMENSIONS ARE GIVEN IN MILLIMETERS.
T12-125 T12-125
T12-125 T12-125 T12-125 T12-125
5. CONCRETE MIX TO BE WITH A MAXIMUM AGGREGATE SIZE NOT GREATER THAN 20mm
6. CONCRETE GRADE :
SLABS - C25
BEAMS - C25
WALLS - C25
COLUMNS - AS PER R/F DRAWING
T12-125 T12-125
7. NO CONCRETE IS TO BE POURED UNTIL THE REINFORCEMENT HAS BEEN INSPECTED AND
T12-125 T12-125 APPROVED BY THE CONSULTANT.
T10-125 T10-125
8. APPROVED WATERPROOFING TO BE APPLIED ON ALL SURFACES THAT CONTAIN OR EXCLUDE
T10-125 T10-125
WATER.
CLIENT CONSULTANT KEY PLAN REVISION DESCRIPTION DATE BY PROJECT DRAWING TITLE
PROPOSED APARTMENT HOTEL RFRFDETAILS
DETAILS OF
OFGROUND FLOOR
FUEL TANK
SERENIA LIMITED CIVIL AND STRUCTURAL ENGINEERING AT THALPE
No. 724, CONSULTANTS(PVT)LTD.
772/A, WIJESINGHE MAWATHA, MADINNAGODA, DATE SCALE SHEET SIZE
MIHIRIPENNA, DESIGNED : Eng. RASADI DISANAYAKA DESIGN CHECKED : SH SHEET No
RAJAGIRIYA, SRI LANKA. 17-10-2023 AS GIVEN A2
THALPE. T +94 112 683 979 F +94 718 802 859 DRAWN : MH DRAFTING CHECKED : DH
STRENGTH SERVICEABILITY SAFETY SUSTAINABILITY E mail - contact@csec.lk Web - www.csec.lk PROJECT No 18005-SK03
18005-SK04 REVISION ISSUE
FILE NAME, PATH AND OTHER INFO.
APPROVED : Eng. SHIROMAL FERNANDO 18005 R00 CON