01. JB TAB - OLT 400 M 1550

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OTDR report

Job info
Job ID : A212601000049(Feeder1) Reason :
Contractor : PT TRIMITRA KOLABORASI MANDIRI Operator A : PEKI
Customer : PT INDONESIA COMNETS PLUS Operator B : NICO
Test date : 06/01/2024 File : 400 1550.sor

Cable info
Fiber ID : Cable ID : ADSS
Location A : JB TAB Location B : OLT
Cable mfr. : FIBERHOME Type :
Subset ID : BLUE Color ID : BLUE

Link measurements
Span loss : 2.462 dB Avg. splice loss : ---
Span length : 0.4001 km Max. splice loss : ---
Average loss : --- Span ORL : ---

OTDR trace

dB

25.00

20.00
1

15.00

10.00

5.00

0.00
200 400 600 800 1000 1200 1400 1600 1800 m

Signature : _________________________ Date : 18/06/2023


EXFO E. O. Engineering Inc. Page 1 / 2
OTDR report
Events table
No. Loc. Event type Loss Refl. Att. Cumul.
(km) (dB) (dB) (dB/km) (dB)

1 0.0000 Launch Level 0.000 --- 0.000


Fiber Section (0.1228 km) 0.000 0.000 0.000
0.1228 Reflective Fault 0.000 0.0 0.000
Fiber Section (0.2647 km) 2.092 7.902 2.092
0.4002 Reflective Fault 0.000 -55.2 2.092

Marker info
A : 0.0000 km, 21.577 dB B : 0.0000 km, 21.577 dB
a : 0.0000 km, 21.577 dB b : 0.0000 km, 21.577 dB
A to B distance : 0.0000 km, 0.000 dB A to B ORL : *****
3-pt. reflectance : ***** A to B LSA att. : -0.000 dB/km
4-pt. Ev. loss : 0.000 dB

Test and cable setup


Wavelength : 1550 nm (SM-9µm) Acq. time : 2s
Filename : 400 1550.sor Pulse width : 50 ns
Hardware : Helix factor : 0.00 %
Serial number : Splice loss threshold : 0.000 dB
Software : N/A Reflectance threshold : -0.0 dB
Range : 0.0000 km End-of-fiber threshold : 0.000 dB
IOR : 1.465000
RBS : 79.50

Signature : _________________________ Date : 18/06/2023


EXFO E. O. Engineering Inc. Page 2 / 2