GENERAL NOTES

1 . All dimensions are in mm unless otherwise


stated .
2. All dimensions shall be confirmed on site and any
discrepancies thereof shall be reffered to the Arch .
before commencement of any works .
3. All dimensions shall be read off and not scaled
from the drawing .
4. p. v to denote permanent ventilation and to be
provided at all openings .
5. All structural works shall be subject to structural
engineering details and instructions .
6. All pipes passing under driveway and under
buildings to be encased with 150 mm thick concrete
surround .
7. D. P. M to denote damp proof membrane and to
be applied under the ground floor slab to
manufacturers specifications .
8. D. P. C to denote damp proof course and to be
applied under all ground floor and parapet walls .
9. Excavate all vegetable soil to a minimum depth
of 200 mm .
10 . Reinforced concrete class 20 to all strip
footings and column bases subject to S. Es detail
and depths to be determined on site .
11 . All sanitary works to comply with M. O. H rules
and regulations . The plumbing and foul drainage
fittings to be subject to manufacturers
specifications and architects approval .
12 . Liquid waste pipes and soil pipes to be in ducts
and p. v. c to have bends with cleaning eyes
accesible from external .
13 . Windows to be provided with precast cill , built
in p. v pelmetbox , timber board and burglar
proofing all subject to architects approval .
14 . Door frames to be rebated and to be provided
with architraves , matching cornice and skirting , all
subject to architects schedule .
ROOF CONSTRUCTION
15 . All surface finishes to be subject to architect 's
22.50 Degrees roof pitch ,gauge 28 g.c
roof cover. ROOF CONSTRUCTION
schedule in conjunction with the manufacturer 's
-Rafters 100* 50 mm .
-Struts 75*50mm.
22.50 Degrees roof pitch ,gauge 28 g.c
roof cover.
specification .
-King posts 100mm*50mm.
- Tie beam 150mm* 50mm.
-Rafters 100* 50 mm .
-Struts 75*50mm.
16 . All fixtures and fittings shall be subject to
-Wall plate 100mm*50mm.
-Fascia board 225MM*25MM.
-King posts 100mm*50mm.
- Tie beam 150mm* 50mm.
architect 's details and approval before fixing .
-Wall plate 100mm*50mm.
-Fascia board 225MM*25MM. 17 . Provide 300 mm plinth level from general
ground level .
18 . All walls shall be reinforced with hoop iron at
alternate courses .
19 . All electrical works and telecom cabling and
conduits shall be done by registered persons and

2115
1,813
shall comply with by -laws in force .
20 . Provide 1 /2-hr fire resistance self closing doors
to all external entrances .
LADIES' BLOCK 200 X 450 mm deep 200 X 450 mm deep RC
GENTS' BLOCK 21 . Provide 2x 9-kg dry powder all purpose fire
450

450
steel casement RC ring beam to struct

350

350
ring beam to struct Eng's

extinguishers to all entrances .


window to schedule.
Eng's details. details.

22 . All works shall conform to the regulations of


the National Environmental Management Authority

1,575
(N. E. M. A) in force .

2,750
200mm thick
2,400

2,400
2,400
masonry walling
plastered and
painted to
CUBICLE
approval
CUBICLE Revision History

825
RevID ChID Change Name Date
150

COURTARD
FOUNDATION SPECIFICATIONS
-Tiles floor finish.
- Foundation depth to be determined on site.
FOUNDATION SPECIFICATIONS -150mm thick in 1: 2:4 mass concrete floor slab.
-Tiles floor finish. -A142 BRC Meshed wire .
- Foundation depth to be determined on site. -DPM 500 gauge.
-150mm thick in 1: 2:4 mass concrete floor slab. - 50mm thick blinding layer.
-A142 BRC Meshed wire . BUILDING SECTION S-01 -300mm well compated and consolidated hardcore
-DPM 500 gauge. fillings .
- 50mm thick blinding layer. PLAN -600*200 thick mass concrete strip foundation to S.E
-300mm well compated and consolidated hardcore details. CONSULTANT
fillings .
-600*200 thick mass concrete strip foundation to S.E
details.

COUNTY GOVERNMENT OF NAKURU


DEPARTMENT OF PUBLIC WORKS .
P.O BOX 2870 -20100 , NAKURU

CLIENT
Department of Youth, Sports and Social Services

PROJECT

DRAWING TITLE
FLOOR PLAN, ELEVATIONS, SECTIONS

DRAWING STATUS .

WORKING DRAWINGS

DRAWN BY DATE .
RONO DANIEL DEC,2023

CHECKED BY DATE
DEC,2023
DRAWING SCALE (@ A1 )
1 :50 ,1 :100
DRAWING NO . REVISION
______
GSPublisherVersion 0.0.100.11
GSPublisherVersion 0.15.100.100

GSPublisherVersion 0.0.100.11
GSPublisherVersion 0.0.100.11

GSPublisherVersion 0.98.100.100