TEQP2024-510=VISHWARAJ Agra UPJN Submersible Pumps (Dragged)
CP3351 / 906.000
2024-03-13 . 164 CURVE NAME
300 2
1
200
3
100
0 400 800 1200 1600 2000 2400 2800 3200 3600
Flow [m3/h]
Duty points Flow [m3/h] Head [m] Power [kW] Efficiency [%] NPSHr [m] Standard Guarantee (-> no guarantee
1 1565 48.0 (274) (264) 75.3 (78.1) 5.02 m ISO9906:2012 2B QH and Eff.
2960 29.5 (342) (330) (69.6) (72.1) 13.0 m On Curve None (Point Out of allowable range)
30.0 65.3 (173) (165) (3.1) (3.2) 7.07 m On Curve None
72
Efficiency [%]
Head [m]
NPSH [m]
(Allowable Operating Range
64 90
3 1120 m3/hr to 2565 m3/hr)
56 75 18
48 60 15
1
81.4 %
40 45 12
NPSHr 11.0 m
32 30 9
2
24 15 6
NPSHr
16 0 3
0 400 800 1200 1600 2000 2400 2800 3200 3600
Flow [m3/h]
NOTE: AUTHOR:
CURVES SHOW PERFORMANCE WITH CLEAR COLD WATER
* : PUMP EFFICIENCY / SHAFT POWER CYRIL GUERET
O : OVERALL EFFICIENCY / INPUT POWER
NPSHR = NPSH3 + MARGIN
NO OPERATION ALONG DASHED CURVE.
C 3351 ** 3~ 6p at 50HZ
System Curve: Pump at Various water levels in Lifting Station
80.00
75.00
70.00
65.00
60.00
55.00 4 6
Head (m)
5
1 3
2
50.00
45.00
40.00
35.00
30.00
6"
1" 2" 3" 4" 5"
25.00
0 2000 4000 6000 8000 10000 12000 14000 16000 18000