Professional Documents
Culture Documents
EXB16007_Automatisme_EN_2021
EXB16007_Automatisme_EN_2021
CONTROL UNITS
for supply inversion
QUICK TO INSTALL,
PROVIDE OPTIMUM
CONTINUITY OF SERVICE
ou G ou G
ou G ou G
ou G ou G
INPUTS 6 programmable digital inputs 8 programmable digital inputs 12 programmable digital inputs
CONTROL FUNCTIONS
Min. and max. voltage - Phase cutting - Voltage imbalance - Min. and max. frequency
ON THE LINES
PROGRAMMING Direct on front panel or with USB or Wi-Fi communication modules and software or Legrand ACU Configurator app
ACCESSORIES
MODULE FOR DUAL POWER SUPPLY (CAT.No 4 226 86)
CLEAR MARKING
Clear marking on the
front panel for easy
identification of the
various functions
2
INTUITIVE USER INTERFACE
Simplified access to the various Counters for maintenance operations: Functions associated with the various inputs
parameters: and outputs are preconfigured.
- Operating hours Other settings are possible, to meet the user's
- Status - Number of operations by circuit breakers needs as closely as possible.
- Voltage and frequency measurement associated with the unit. An alarm trips, as
- Reports soon as preset thresholds for maintenance
- Trip thresholds operations are reached.
- Alarms
The settings are grouped into The event log is used to view the data in order Real-time clock with working reserve
4 categories: to understand and master how the system
- Trip thresholds works.
- Remotely-controllable parameters
- User alarms
- Counters
The automation control units for The shallow depth of the The fixing system using metal
advanced management of 5 circuit configurable controllers makes screws ensures they will stay
breakers and 3 power sources them exceptionally easy to install, in place for a long time.
Cat.No 4 226 84 has a certain number even in slim electrical panels.
of parameters that must be factory
configured in order to perfectly fit the
requirements of your project.
Please ask for the specific order form
including technical support.
4
USB MODULE
Cat.No 4 226 87 is supplied with a USB cable which can be used to connect the
control unit to a computer without having to cut off the power to the electrical
cabinet, to program the unit, launch diagnostics, download all the back-up
parameters, and update the firmware.
WI-FI MODULE
Cat.No 4 226 88 can be used to program the unit, launch diagnostics, download
all the back-up parameters, or replicate all the data (parameters, counters, log)
via a PC, tablet or smartphone, without using a cable. The replication function is
useful for transferring all the data from one unit to another or for reverting to a
previous configuration (on the same control unit)
- Display the values measured by the control unit and check parameter setting
- Control certain control unit functions such as counter reset, activation/deactivation of programmable outputs
- Configure the unit and make a copy in the form of a back-up file
- View current alarms
- Consult the event log and save a copy
- Manage different access password levels
- Manage embedded PLC features (through SW, for the control units Cat.Nos 4 226 83/84)
6
Choice of operating mode
(manual/automatic/OFF)
and reset
Pack Cat.Nos Automatic transfer switch control units Pack Cat.Nos Dual power supply selector
For standard management of 2 circuit breakers 1 4 226 86 Dual power supply selector measures and controls
1 4 226 811 6 programmable digital inputs and 7 programmable two supply voltages at its inputs (single phase,
relay outputs 230 VA) and selects the most adapted voltage for
LCD display auxiliary circuits supply
IR communication port on the front panel for Equipped with 1 alarm contact, if no supply voltage
connection of USB or WiFi modules can be selected within the limits
Cat.Nos 4 226 87/88
Can be configured with the help of front panel touch Plug-in modules
keys or of the Legrand dedicated software 1 4 226 89 Opto-isolated RS485 interface
Power supply: 110-240 VA 1 4 226 90 4 opto-isolated static outputs
IP40 1 4 226 91 2 relay outputs, rated 5 A 250 VA
For advanced management of 2 circuit breakers 1 4 226 92 2 opto-isolated digital inputs and 2 relay outputs
1 4 226 821 6 programmable digital inputs and 7 programmable rated 5 A 250 VA
relay outputs
Can be equipped with maximum 2 plug-in modules Communication accessories
between: These communication devices can be used to
- extension modules Cat.Nos 4 226 90/91/92 connect Alptec 8 and Alptec 3.2/5.2/8.2 power
- opto-isolated RS485 communication interface factor controllers (p. 123) and automatic transfer
Cat.No 4 226 89 switch controllers to a computer; smartphone or
LCD display tablet
IR communication port on the front panel for For progamming, downloading data, diagnostics
connection of USB or WiFi modules and upgrading the firmware
Cat.Nos 4 226 87/88
Can be configured with the help of front panel touch USB front connector
keys or of the Legrand dedicated software 1 4 226 871 Computer connection cable with USB connector
Power supply: 12-24 V= ; 110-240 VA The computer identifies the connection as a
IP40 standard USB connection. There is no need to
switch off the controller power supply
For advanced management of 3 circuit breakers
and 2 power sources Wi-Fi front connector
1 4 226 83 8 programmable digital inputs and 7 programmable
1 1 4 226 881 Wi-Fi connection device compatible with computers,
relay outputs smartphones and tablets
Can be equipped with maximum 3 plug-in extension There is no need to switch off the controller power
modules between Cat.Nos 4 226 90/91/92 supply
Integrated opto-isolatied RS485 communication
interface 1: Configuration software available for download via e-catalogue
ACU Configurator app for smartphone and tablet available on Apple
LCD display Store and Google Play
IR communication port on the front panel for
connection of USB or WiFi modules
Cat.Nos 4 226 87/88
Can be configured with the help of front panel touch
keys or of the Legrand dedicated software
Power supply: 12-24-48 V= ; 110-240 VA
IP65
For advanced management of 5 circuit breakers
and 3 power sources
1 4 226 841 12 programmable digital inputs and 11 programmable
relay outputs
Can be equipped with maximum 3 plug-in extension
modules between Cat.Nos 4 226 90/91/92
Integrated opto-isolatied RS485 communication
interface
LCD display
IR communication port on the front panel for
connection of USB or WiFi modules
Cat.Nos 4 226 87/88
Can be configured with the help of front panel touch
keys or of the Legrand dedicated software
Power supply: 12-24-48 V= ; 110-240 VA
IP65
Must be factory configured to fit installation needs
Please ask for ATS order form.
8
Automation control units for transfer switches
technical characteristics and dimensions
144
Measurement True RMS value True RMS value True RMS value True RMS value
type
Single phase, Single phase, Single phase, Single phase,
two-phase or two-phase or two-phase or two-phase or
Connection three-phase three-phase three-phase three-phase
modes system with or system with or system with or system with or
without neutral without neutral without neutral without neutral
Measuring ± 0.25% f.s. ± 0.25% f.s. ± 0.25% f.s. ± 0.25% f.s. 35
error ± 1 digit ± 1 digit ± 1 digit ± 1 digit
Operating -30... +70 °C -30... +70 °C -30... +70 °C -30... +70 °C
temperature
Door cut
Storage -30...+80 °C -30...+80 °C -30...+80 °C -30...+80 °C 138
temperature
Relativity 80 % (IEC/EN 80 % (IEC/EN 80 % (IEC/EN 80 % (IEC/EN
humidity 60068-2-78) 60068-2-78) 60068-2-78) 60068-2-78)
Ambient conditions
Maximum
pollution 2 2 2 2
degree
Overvoltage 3 3 3 3
category
138
Measurement III III III III
category
Rated impulse
withstand Uimp 7.3 kV Uimp 7.3 kV Uimp 7.3 kV Uimp 7.3 kV
voltage
Protection IP 40 IP 40 IP 65 IP 65
index
6 6 8 12
Inputs programmables programmables programmables programmables
Expandibility No Yes (2 modules) Yes (3 modules) Yes (3 modules) 240 32.6 11.3
n Dimensions
Cat.No 4 226 86
58
53.5 5 43.7
Door cut
220
104.7
98.3
45
90
Ø 4.2 59.9
160
In accordance with its policy of continual improvement, the company reserves the right
to modify the characteristics and design of its products without warning. All illustrations,
descriptions, dimensions, and weights indicated in this catalogue are given as a guide only
and the company cannot be held liable for their accuracy.
FOLLOW
US ON
legrand.com
youtube.com/user/legrand
facebook.com/Legrand
twitter.com/Legrand
pinterest.com/legrandgroup
instagram.com/legrandnews
EXB16007 – February 2021
Head Office
and International Department
87045 Limoges Cedex - France
Tel: + 33(0)5 55 06 87 87
Fax: +33(0)5 55 06 74 55